Displaying publications 1 - 20 of 72 in total

Abstract:
Sort:
  1. Meyers SM, Winter JD, Obeidi Y, Chung P, Menard C, Warde P, et al.
    Med Dosim, 2023 11 18;49(2):150-158.
    PMID: 37985297 DOI: 10.1016/j.meddos.2023.10.008
    Postoperative prostate radiotherapy requires large planning target volume (PTV) margins to account for motion and deformation of the prostate bed. Adaptive radiation therapy (ART) can incorporate image-guidance data to personalize PTVs that maintain coverage while reducing toxicity. We present feasibility and dosimetry results of a prospective study of postprostatectomy ART. Twenty-one patients were treated with single-adaptation ART. Conventional treatments were delivered for fractions 1 to 6 and adapted plans for the remaining 27 fractions. Clinical target volumes (CTVs) and small bowel delineated on fraction 1 to 4 CBCT were used to generate adapted PTVs and planning organ-at-risk (OAR) volumes for adapted plans. PTV volume and OAR dose were compared between ART and conventional using Wilcoxon signed-rank tests. Weekly CBCT were used to assess the fraction of CTV covered by PTV, CTV D99, and small bowel D1cc. Clinical metrics were compared using a Student's t-test (p < 0.05 significant). Offline adaptive planning required 1.9 ± 0.4 days (mean ± SD). ART decreased mean adapted PTV volume 61 ± 37 cc and bladder wall D50 compared with conventional treatment (p < 0.01). The CTV was fully covered for 96% (97%) of fractions with ART (conventional). Reconstructing dose on weekly CBCT, a nonsignificant reduction in CTV D99 was observed with ART (94%) compared to conventional (96%). Reduced CTV D99 with ART was significantly correlated with large anterior-posterior rectal diameter on simulation CT. ART reduced the number of fractions exceeding our institution's small bowel D1c limit from 14% to 7%. This study has demonstrated the feasibility of offline ART for post-prostatectomy cancer. ART facilitates PTV volume reduction while maintaining reasonable CTV coverage and can reduce the dose to adjacent normal tissues.
    Matched MeSH terms: Radiotherapy Dosage
  2. Chua GWY, Ho BS, Ng YY, Master ZR, Sultana R, Cheah P, et al.
    Int J Radiat Oncol Biol Phys, 2023 Oct 01;117(2S):e169-e170.
    PMID: 37784773 DOI: 10.1016/j.ijrobp.2023.06.1010
    PURPOSE/OBJECTIVE(S): Radiotherapy of synchronous bilateral breast cancer poses some technical challenges with regards to dose coverage and sparing of organs at risk (OAR). In this study, we aimed to evaluate dosimetric characteristics of 3 different techniques, IMPT vs photon (VMAT and HT). We hypothesized that IMPT would result in lower doses to organs at risk, as compared to the other 2 techniques.

    MATERIALS/METHODS: A total of 10 patients with synchronous bilateral breast cancer who were treated with VMAT at our institution were retrospectively analyzed. Clinical target volume (CTV) included chest wall and regional nodes (supraclavicular fossa and internal mammary chain) and prescription dose was 40.05 Gy in 15 daily fractions. HT and IMPT plans were generated for each patient. Dose-volume statistics, including planning target volume (PTV) coverage and dose to OAR: lungs, heart, thyroid, spinal cord, brachial plexus and esophagus, were compared between modalities using a paired T-test.

    RESULTS: Mean age of patients was 61 years (43-84). Majority of the patients (80%) were ER+ PR+ and HER2-. 40% of patients underwent breast reconstruction following surgery. All 3 techniques provided adequate target volume distribution and OAR sparing. Compared to VMAT and HT plans, IMPT had better heart and lung sparing effects, resulting in lower mean and V25 Gy heart dose; mean, V20 Gy and V5 Gy lung dose (p<0.0001). There was no significant difference in VMAT and HT plans for mean heart and lung dose. VMAT plans showed significantly lower V25 Gy heart dose on average (p = 0.04). V5 Gy lung dose was slightly lower in HT compared to VMAT plans, approaching statistical significance (p = 0.08). PTV coverage was adequate for all 3 techniques. All techniques fulfilled cord, esophagus, thyroid and brachial plexus constraints.

    CONCLUSION: IMPT plans showed significantly better OAR sparing compared to photon techniques. All 3 techniques met OAR constraints, and resulted in adequate target volume coverage. As IMPT is significantly more costly than VMAT or HT techniques, appropriate patient selection is important to deliver treatment in the most resource-effective manner for patients who would derive the most benefit, for example those with young age or existing heart or lung comorbidities.

    Matched MeSH terms: Radiotherapy Dosage
  3. Yap LM, Jamalludin Z, Ng AH, Ung NM
    Phys Eng Sci Med, 2023 Sep;46(3):1331-1340.
    PMID: 37470929 DOI: 10.1007/s13246-023-01303-x
    The survey is to assess the current state of adaptive radiation therapy (ART) for head and neck (H&N) cases among radiotherapy centers in Malaysia and to identify any implementation limitations. An online questionnaire was sent to all radiotherapy centers in Malaysia. The 24-question questionnaire consists of general information about the center, ART practices, and limitations faced in implementing ART. 28 out of 36 radiotherapy centers responded, resulting in an overall response rate of 78%. About 52% of the responding centers rescanned and replanned less than 5% of their H&N patients. The majority (88.9%) of the respondents reported the use Cone Beam Computed Tomography alone or in combination with other modalities to trigger the ART process. The main reasons cited for adopting ART were weight loss, changes in the immobilization fitting, and anatomical variation. The adaptation process typically occurred during week 3 or week 4 of treatment. More than half of the respondents require three days or more from re-simulation to starting a new treatment plan. Both target and organ at risk delineation on new planning CT relied heavily on manual delineation by physicians and physicists, respectively. All centers perform patient-specific quality assurance for their new adaptive plans. Two main limitations in implementing ART are "limited financial resources or equipment" and "limitation on technical knowledge". There is a need for a common consensus to standardize the practice of ART and address these limitations to improve the implementation of ART in Malaysia.
    Matched MeSH terms: Radiotherapy Dosage
  4. Bradley DA, Essa RZ, Peh SC, Teow SY, Chew MT, Zubair HT, et al.
    Appl Radiat Isot, 2023 Aug;198:110875.
    PMID: 37257265 DOI: 10.1016/j.apradiso.2023.110875
    Review is provided of a number of low-dose, low dose rate situations that in study require advances in the development of dosimetric facilities. Using a clinical linac set up to provide doses down to the few mGy level, the performance of a real-time radioluminescence system has then been illustrated, accommodating pulsed as well as continuous dose delivery. The system gate times provide for tracking of the pattern of dose delivery, allowing detailed account of dose and dose-rate variations. The system has been tested in both x-ray and electron mode dose delivery.
    Matched MeSH terms: Radiotherapy Dosage
  5. Ab Shukor NS, Abdullah R, Abdul Aziz MZ, Samson DO, Musarudin M
    Appl Radiat Isot, 2023 Jun;196:110751.
    PMID: 36871495 DOI: 10.1016/j.apradiso.2023.110751
    The present study was conducted to elucidate the effects of hip prostheses in 192Ir HDR brachytherapy and determine dose uncertainties introduced by the treatment planning. A gynaecological phantom irradiated using Nucletron 192Ir microSelectron HDR source was modeled using MCNP5 code. Three hip materials considered in this study were water, bone, and metal prosthesis. According to the obtained results, a dose perturbation was observed within the medium with a higher atomic number, which reduced the dose to the nearby region.
    Matched MeSH terms: Radiotherapy Dosage
  6. Aminordin Sabri AH, Mohamad Tajudin S, Abdul Aziz MZ, Furuta T
    Radiol Phys Technol, 2023 Mar;16(1):109-117.
    PMID: 36729272 DOI: 10.1007/s12194-023-00703-8
    In a brachytherapy room irradiated with an Iridium-192 (192Ir) source, the spatial distributions of photon dose rates were measured and calculated for the dose distribution both inside and outside the room. The spatial distributions were measured using a thermoluminescent dosimeter (LiF-100) on the surfaces of the concrete walls and barriers of the irradiation room. The calculations were performed using the particle and heavy ion transport code system (PHITS) by considering the detailed model of the brachytherapy room and the radiation source used in the measurements. The measured and calculated doses exhibited a similar distribution pattern within and outside the brachytherapy room. To reduce the edge effect at the entrance door, the addition of a 3-mm thick lead layer on the surface of the concrete wall on the left doorstop is recommended. For the 60Co source, with the existing walls and lead door thickness, the dose at the control console and in front of the entrance maze increased by a factor of approximately 60.
    Matched MeSH terms: Radiotherapy Dosage
  7. Loh ZH, Mohamad S, Gan BC, Zakaria Z, Mohamad I
    Med J Malaysia, 2023 Mar;78(2):197-201.
    PMID: 36988530
    INTRODUCTION: Nasopharyngeal carcinoma (NPC) is among the most common malignancy in Malaysia. Radiationinduced hypothyroidism has been reported in other countries. However, in Malaysia, no studies were ever done to determine the effect of radiation on hypothyroidism. The objective of this study is to evaluate the practice of taking thyroid function test (TFT) and determine hypothyroidism post-radiation in patients with NPC.

    MATERIALS AND METHODS: A retrospective study on the symptoms and results of TFT according to the dosage of intensity-modulated radiotherapy (IMRT) given to patients with NPC. Data were traced and analysed.

    RESULTS: A total of 78 patients were identified. All patients received IMRT with 33-35 fractions of radiotherapy (RT) with total dosage of 66-70 Gray given. Not all patients had their thyroid function status measured routinely. Twelve patients did have symptoms of hypothyroidism. TFT were obtained in this group but the results were normal. No correlation was found between RT and hypothyroidism.

    CONCLUSION: There was no correlation between IMRT and the development of hypothyroidism. A prospective study with better control of inclusion and exclusion criteria, and longer follow-up period with TFT, is needed to demonstrate the consistency of these findings.

    Matched MeSH terms: Radiotherapy Dosage
  8. Entezam A, Fielding A, Bradley D, Fontanarosa D
    PLoS One, 2023;18(2):e0280765.
    PMID: 36730280 DOI: 10.1371/journal.pone.0280765
    Computed tomography (CT) derived Monte Carlo (MC) phantoms allow dose determination within small animal models that is not feasible with in-vivo dosimetry. The aim of this study was to develop a CT-derived MC phantom generated from a mouse with a xenograft tumour that could then be used to calculate both the dose heterogeneity in the tumour volume and out of field scattered dose for pre-clinical small animal irradiation experiments. A BEAMnrc Monte-Carlo model has been built of our irradiation system that comprises a lead collimator with a 1 cm diameter aperture fitted to a Cs-137 gamma irradiator. The MC model of the irradiation system was validated by comparing the calculated dose results with dosimetric film measurement in a polymethyl methacrylate (PMMA) phantom using a 1D gamma-index analysis. Dose distributions in the MC mouse phantom were calculated and visualized on the CT-image data. Dose volume histograms (DVHs) were generated for the tumour and organs at risk (OARs). The effect of the xenographic tumour volume on the scattered out of field dose was also investigated. The defined gamma index analysis criteria were met, indicating that our MC simulation is a valid model for MC mouse phantom dose calculations. MC dose calculations showed a maximum out of field dose to the mouse of 7% of Dmax. Absorbed dose to the tumour varies in the range 60%-100% of Dmax. DVH analysis demonstrated that tumour received an inhomogeneous dose of 12 Gy-20 Gy (for 20 Gy prescribed dose) while out of field doses to all OARs were minimized (1.29 Gy-1.38 Gy). Variation of the xenographic tumour volume exhibited no significant effect on the out of field scattered dose to OARs. The CT derived MC mouse model presented here is a useful tool for tumour dose verifications as well as investigating the doses to normal tissue (in out of field) for preclinical radiobiological research.
    Matched MeSH terms: Radiotherapy Dosage
  9. Tabbakh F, Hosmane NS, Tajudin SM, Ghorashi AH, Morshedian N
    Sci Rep, 2022 Oct 18;12(1):17404.
    PMID: 36258012 DOI: 10.1038/s41598-022-22429-0
    There are two major problems in proton therapy. (1) In comparison with the gamma-ray therapy, proton therapy has only ~ 10% greater biological effectiveness, and (2) the risk of the secondary neutrons in proton therapy is another unsolved problem. In this report, the increase of biological effectiveness in proton therapy has been evaluated with better performance than 11B in the presence of two proposed nanomaterials of 157GdF4 and 157Gd doped carbon with the thermal neutron reduction due to the presence of 157Gd isotope. The present study is based on the microanalysis calculations using GEANT4 Monte Carlo tool and GEANT4-DNA package for the strand breaks measurement. It was found that the proposed method will increase the effectiveness corresponding to the alpha particles by more than 100% and also, potentially will decrease the thermal neutrons fluence, significantly. Also, in this work, a discussion is presented on a significant contribution of the secondary alpha particles in total effectiveness in proton therapy.
    Matched MeSH terms: Radiotherapy Dosage
  10. Martin CJ, Kron T, Vassileva J, Wood TJ, Joyce C, Ung NM, et al.
    Phys Med, 2021 Oct;90:53-65.
    PMID: 34562809 DOI: 10.1016/j.ejmp.2021.09.004
    Improvements in delivery of radiation dose to target tissues in radiotherapy have increased the need for better image quality and led to a higher frequency of imaging patients. Imaging for treatment planning extends to function and motion assessment and devices are incorporated into medical linear accelerators (linacs) so that regions of tissue can be imaged at time of treatment delivery to ensure dose distributions are delivered as accurately as possible. A survey of imaging in 97 radiotherapy centres in nine countries on six continents has been undertaken with an on-line questionnaire administered through the International Commission on Radiological Protection mentorship programme to provide a snapshot of imaging practices. Responses show that all centres use CT for planning treatments and many utilise additional information from magnetic resonance imaging and positron emission tomography scans. Most centres have kV cone beam CT attached to at least some linacs and use this for the majority of treatment fractions. The imaging options available declined with the human development index (HDI) of the country, and the frequency of imaging during treatment depended more on country than treatment site with countries having lower HDIs imaging less frequently. The country with the lowest HDI had few kV imaging facilities and relied on MV planar imaging intermittently during treatment. Imaging protocols supplied by vendors are used in most centres and under half adapt exposure conditions to individual patients. Recording of patient doses, a knowledge of which is important in optimisation of imaging protocols, was limited primarily to European countries.
    Matched MeSH terms: Radiotherapy Dosage
  11. Nazeri AAZA, Sani SFA, Ung NM, Almugren KS, Alkallas FH, Bradley DA
    Appl Radiat Isot, 2021 Oct;176:109814.
    PMID: 34175543 DOI: 10.1016/j.apradiso.2021.109814
    Brachytherapy is commonly used in treatment of cervical, prostate, breast and skin cancers, also for oral cancers, typically via the application of sealed radioactive sources that are inserted within or alongside the area to be treated. A particular aim of the various brachytherapy techniques is to accurately transfer to the targeted tumour the largest possible dose, at the same time minimizing dose to the surrounding normal tissue, including organs at risk. The dose fall-off with distance from the sources is steep, the dose gradient representing a prime factor in determining the dose distribution, also representing a challenge to the conduct of measurements around sources. Amorphous borosilicate glass (B2O3) in the form of microscope cover slips is recognized to offer a practicable system for such thermoluminescence dosimetry (TLD), providing for high-spatial resolution (down to 
    Matched MeSH terms: Radiotherapy Dosage*
  12. Jamalludin Z, Malik RA, Ung NM
    Phys Eng Sci Med, 2021 Sep;44(3):773-783.
    PMID: 34191272 DOI: 10.1007/s13246-021-01026-x
    Intracavitary cervical brachytherapy delivers high doses of radiation to the target tissue and a portion of these doses will also hit the rectal organs due to their close proximity. Rectal dose can be evaluated from dosimetric parameters in the treatment planning system (TPS) and in vivo (IV) dose measurement. This study analyzed the correlation between IV rectal dose with selected volume and point dose parameters from TPS. A total of 48 insertions were performed and IV dose was measured using the commercial PTW 9112 semiconductor diode probe. In 18 of 48 insertions, a single MOSkin detector was attached on the probe surface at 50 mm from the tip. Four rectal dosimetric parameters were retrospectively collected from TPS; (a) PTW 9112 diode maximum reported dose (RPmax) and MOSkin detector, (b) minimum dose to 2 cc (D2cc), (c) ICRU reference point (ICRUr), and (d) maximum dose from additional points (Rmax). The IV doses from both detectors were analyzed for correlation with these dosimetric parameters. This study found a significantly high correlation between IV measured dose from RPmax (r = 0.916) and MOSkin (r = 0.959) with TPS planned dose. The correlation between measured RPmax with both D2cc and Rmax revealed high correlation of r > 0.7, whereas moderate correlation (r = 0.525) was observed with ICRUr. There was no significant correlation between MOSkin IV measured dose with D2cc, ICRUr and Rmax. The non-significant correlation between parameters was ascribable to differences in both detector position within patients, and dosimetric volume and point location determined on TPS, rather than detector uncertainties.
    Matched MeSH terms: Radiotherapy Dosage
  13. Begum M, Rahman AKMM, Abdul-Rashid HA, Yusoff Z, Mat Nawi SN, Khandaker MU, et al.
    Appl Radiat Isot, 2021 Aug;174:109771.
    PMID: 34048992 DOI: 10.1016/j.apradiso.2021.109771
    Present study concerns the key thermoluminescence (TL) properties of photonic crystal fibres (PCFs), seeking development of alternatively structured TL materials that are able to offer a advantages over existing passive dosimeters. In terms of their internal structure and light guiding properties the PCFs, collapsed and structured, differ significantly from that of conventional optical fibres. To investigate the dosimetric parameters of the PCFs use was made of a linear accelerator producing a 6 MV photon beam, delivering doses ranging from 0.5 Gy to 8 Gy. The parameters studied included TL response, linearity index, glow curves, relative sensitivity and TL signal fading, the results being compared against those obtained using TLD-100 chips. At 4 Gy photon dose the Ge-doped collapsed PCFs were found to provide a response 27 × that of structured PCF, also giving a TL yield similar to that of standard TLD-100 chips. Over post-irradiation periods of 15 and 30 days collapsed PCF TL signal fading were 8% and 17% respectively, with corresponding values of 37% and 64% for the structured PCF. Trapping parameters including the order of kinetics (b), activation energy (E) and frequency factor (s-1) were assessed with Chen's peak shape method. Lifetime of trapping centre was found to be (2.36 E+03) s and (9.03 E +01) s regarding the collapsed and structured PCF respectively with 6 Gy of photon beam. For the Ge-doped collapsed PCF, the high TL yield, sensitivity and low fading provide the basis of a highly promising system of TLD for radiotherapy applications.
    Matched MeSH terms: Radiotherapy Dosage*
  14. Chew MT, Daar E, Khandaker MU, Jones B, Nisbet A, Bradley DA
    Br J Radiol, 2021 Aug 01;94(1124):20201265.
    PMID: 34192471 DOI: 10.1259/bjr.20201265
    Infection, the invasion of pathogenic microorganisms and viruses, causes reactive inflammation mediated by endogenous signals, with influx of leucocytes with distinct properties and capable of mounting a cellular or antibody response. Different forms of inflammation may also occur in response to tumours, in allergy and autoimmune disorders. Pneumonia, respiratory tract infection and septic shock for instance can arise as serious complications of the Covid-19 virus. While radiotherapy has been most widely used to control malignant tumours, it has also been used for treatment of non-malignant diseases, including acute and chronic inflammation in situations where anti-inflammatory drugs may be ineffective or contraindicated. The present review examines the history and prospects for low-dose anti-inflammatory radiation treatments, the present interest largely being motivated by the increased incidence of pulmonary disease associated Covid-19 infections. Evidence in support of the suggested efficacy are covered, together with an appraisal of one of the number of potential convenient sources that could complement external beam arrangements.
    Matched MeSH terms: Radiotherapy Dosage
  15. Hasan N, Sham NFR, Karim MKA, Fuad SBSA, Hasani NAH, Omar E, et al.
    Sci Rep, 2021 Jul 15;11(1):14559.
    PMID: 34267293 DOI: 10.1038/s41598-021-93964-5
    We presented a development of a custom lead shield and mouse strainer for targeted irradiation from the gamma-cell chamber. This study was divided into two parts i.e., to (i) fabricate the shield and strainer from a lead (Pb) and (ii) optimize the irradiation to the mice-bearing tumour model with 2 and 8 Gy absorbed doses. The lead shielding was fabricated into a cuboid shape with a canal on the top and a hole on the vertical side for the beam path. Respective deliveries doses of 28 and 75 Gy from gamma-cell were used to achieve 2 and 8 Gy absorbed doses at the tumour sites.
    Matched MeSH terms: Radiotherapy Dosage
  16. Hizam DA, Jong WL, Zin HM, Ng KH, Ung NM
    Med Dosim, 2021 04 08;46(3):310-317.
    PMID: 33838998 DOI: 10.1016/j.meddos.2021.03.003
    Intensity-modulated radiotherapy (IMRT) treatment planning for head and neck cancer is challenging and complex due to many organs at risk (OAR) in this region. The experience and skills of planners may result in substantial variability of treatment plan quality. This study assessed the performance of IMRT planning in Malaysia and observed plan quality variation among participating centers. The computed tomography dataset containing contoured target volumes and OAR was provided to participating centers. This is to control variations in contouring the target volumes and OARs by oncologists. The planner at each center was instructed to complete the treatment plan based on clinical practice with a given prescription, and the plan was analyzed against the planning goals provided. The quality of completed treatment plans was analyzed using the plan quality index (PQI), in which a score of 0 indicated that all dose objectives and constraints were achieved. A total of 23 plans were received from all participating centers comprising 14 VMAT, 7 IMRT, and 2 tomotherapy plans. The PQI indexes of these plans ranged from 0 to 0.65, indicating a wide variation of plan quality nationwide. Results also reported 5 out of 21 plans achieved all dose objectives and constraints showing more professional training is needed for planners in Malaysia. Understanding of treatment planning system and computational physics could also help in improving the quality of treatment plans for IMRT delivery.
    Matched MeSH terms: Radiotherapy Dosage
  17. Sulieman A, Mayhoub FH, Salah H, Al-Mohammed HI, Alkhorayef M, Moftah B, et al.
    Appl Radiat Isot, 2020 Oct;164:109240.
    PMID: 32819499 DOI: 10.1016/j.apradiso.2020.109240
    Lutetium-177 (DOTATATE) (177Lu; T1/2 6.7 days), a labelled β- and Auger-electron emitter, is widely used in treatment of neuroendocrine tumours. During performance of the procedure, staff and other patients can potentially receive significant doses in interception of the gamma emissions [113 keV (6.4%) and 208 keV (11%)] that are associated with the particle decays. While radiation protection and safety assessment are required in seeking to ensure practices comply with international guidelines, only limited published studies are available. The objectives of present study are to evaluate patient and occupational exposures, measuring ambient doses and estimating the radiation risk. The results, obtained from studies carried out in Riyadh over an 11 month period, at King Faisal Specialist Hospital and Research Center, concerned a total of 33 177Lu therapy patients. Patient exposures were estimated using a calibrated Victoreen 451P survey meter (Fluke Biomedical), for separations of 30 cm, 100 cm and 300 cm, also behind a bed shield that was used during hospitalization of the therapy patients. Occupational and ambient doses were also measured through use of calibrated thermoluminescent dosimeters and an automatic TLD reader (Harshaw 6600). The mean and range of administered activity (in MBq)) was 7115.2 ± 917.2 (4329-7955). The ambient dose at corridors outside of therapy isolation rooms was 1.2 mSv over the 11 month period, that at the nursing station was below the limit of detection and annual occupational doses were below the annual dose limit of 20 mSv. Special concern needs to be paid to comforters (carers) and family members during the early stage of radioisotope administration.
    Matched MeSH terms: Radiotherapy Dosage
  18. Farayola MF, Shafie S, Mohd Siam F, Khan I
    Comput Methods Programs Biomed, 2020 Apr;187:105202.
    PMID: 31835107 DOI: 10.1016/j.cmpb.2019.105202
    Background This paper presents a numerical simulation of normal and cancer cells' population dynamics during radiotherapy. The model used for the simulation was the improved cancer treatment model with radiotherapy. The model simulated the population changes during a fractionated cancer treatment process. The results gave the final populations of the cells, which provided the final volumes of the tumor and normal cells. Method The improved model was obtained by integrating the previous cancer treatment model with the Caputo fractional derivative. In addition, the cells' population decay due to radiation was accounted for by coupling the linear-quadratic model into the improved model. The simulation of the treatment process was done with numerical variables, numerical parameters, and radiation parameters. The numerical variables include the populations of the cells and the time of treatment. The numerical parameters were the model factors which included the proliferation rates of cells, competition coefficients of cells, and perturbation constant for normal cells. The radiation parameters were clinical data based on the treatment procedure. The numerical parameters were obtained from the previous literature while the numerical variables and radiation parameters, which were clinical data, were obtained from reported data of four cancer patients treated with radiotherapy. The four cancer patients had tumor volumes of 28.4 cm3, 18.8 cm3, 30.6 cm3, and 12.6 cm3 and were treated with different treatment plans and a fractionated dose of 1.8 Gy each. The initial populations of cells were obtained by using the tumor volumes. The computer simulations were done with MATLAB. Results The final volumes of the tumors, from the results of the simulations, were 5.67 cm3, 4.36 cm3, 5.74 cm3, and 6.15 cm3 while the normal cells' volumes were 28.17 cm3, 18.68 cm3, 30.34 cm3, and 12.54 cm3. The powers of the derivatives were 0.16774, 0.16557, 0.16835, and 0.16. A variance-based sensitivity analysis was done to corroborate the model with the clinical data. The result showed that the most sensitive factors were the power of the derivative and the cancer cells' proliferation rate. Conclusion The model provided information concerning the status of treatments and can also predict outcomes of other treatment plans.
    Matched MeSH terms: Radiotherapy Dosage
  19. Jamalludin Z, Jong WL, Malik RA, Rosenfeld AB, Ung NM
    Phys Med, 2020 Jan;69:52-60.
    PMID: 31830631 DOI: 10.1016/j.ejmp.2019.11.025
    PURPOSE: Dose to the rectum during brachytherapy treatment may differ from an approved treatment plan which can be quantified with in vivo dosimetry (IVD). This study compares the planned with in vivo doses measured with MOSkin and PTW 9112 rectal probe in patients undergoing CT based HDR cervical brachytherapy with Co-60 source.

    METHODS: Dose measurement of a standard pear-shaped plan carried out in phantom to verify the MOSkin dose measurement accuracy. With MOSkin attached to the third diode, RP3 of the PTW 9112, both detectors were inserted into patients' rectum. The RP3 and MOSkin measured doses in 18 sessions as well as the maximum measured doses from PTW 9112, RPmax in 48 sessions were compared to the planned doses.

    RESULTS: Percentage dose differences ΔD (%) in phantom study for two MOSkin found to be 2.22 ± 0.07% and 2.5 ± 0.07%. IVD of 18 sessions resulted in ΔD(%) of -16.3% to 14.9% with MOSkin and ΔD(%) of -35.7% to -2.1% with RP3. In 48 sessions, RPmax recorded ΔD(%) of -37.1% to 11.0%. MOSkin_measured doses were higher in 44.4% (8/18) sessions, while RP3_measured were lower than planned doses in all sessions. RPmax_measured were lower in 87.5% of applications (42/47).

    CONCLUSIONS: The delivered doses proven to deviate from planned doses due to unavoidable shift between imaging and treatment as measured with MOSkin and PTW 9112 detectors. The integration of MOSkin on commercial PTW 9112 surface found to be feasible for rectal dose IVD during cervical HDR ICBT.

    Matched MeSH terms: Radiotherapy Dosage
  20. Mat Nawi SN, Abdul Sani SF, Khandaker MU, Ung NM, Almugren KS, Alkallas FH, et al.
    PLoS One, 2020;15(7):e0235053.
    PMID: 32673337 DOI: 10.1371/journal.pone.0235053
    Study has been made of the thermoluminescence yield of various novel tailor-made silica fibres, 6 and 8 mol % Ge-doped, with four differing outer dimensions, comprised of flat and cylindrical shapes, subjected to electron irradiation. Main thermoluminescence dosimetric characteristics have been investigated, including the glow curve, dose response, energy dependence, minimum detectable dose, effective atomic number, linearity of index and sensitivity of the fibres. The studies have also established the uncertainties involved as well as the stability of response in terms of fading effect, reproducibility and annealing. In addition, dose-rate dependence was accounted for as this has the potential to be a significant factor in radiotherapy applications. The 6 and 8 mol % fibres have been found to provide highly linear dose response within the range 1 to 4 Gy, the smallest size flat fibre, 6 mol% Ge-doped, showing the greatest response by a factor of 1.1 with respect to the highly popular LiF phosphor-based medium TLD100. All of the fibres also showed excellent reproducibility with a standard deviation of < 2% and < 4% for 6 and 8 mol % Ge-doped fibres respectively. For fading evaluation, the smallest 6 mol% Ge-doped dimension flat fibre, i.e., 85 × 270 μm displayed the lowest signal loss within 120 days post-irradiation, at around 26.9% also showing a response superior to that of all of the other fibres. Moreover, all the fibres and TLD-100 chips showed independence with respect to electron irradiation energy and dose-rate. Compared with the 8 mol% Ge-doped optical fibres, the 6 mol% Ge-doped flat optical fibres have been demonstrated to possess more desirable performance features for passive dosimetry, serving as a suitable alternative to TLD-100 for medical irradiation treatment applications.
    Matched MeSH terms: Radiotherapy Dosage*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links