Affiliations 

  • 1 Faculty of Medicine, Universiti Teknologi MARA, 47200, Sungai Buloh, Selangor, Malaysia
  • 2 Faculty of Science, Universiti Putra Malaysia, 43400, Serdang, Selangor, Malaysia
  • 3 Faculty of Medicine, Universiti Teknologi MARA, 47200, Sungai Buloh, Selangor, Malaysia. mji@uitm.edu.my
Sci Rep, 2021 Jul 15;11(1):14559.
PMID: 34267293 DOI: 10.1038/s41598-021-93964-5

Abstract

We presented a development of a custom lead shield and mouse strainer for targeted irradiation from the gamma-cell chamber. This study was divided into two parts i.e., to (i) fabricate the shield and strainer from a lead (Pb) and (ii) optimize the irradiation to the mice-bearing tumour model with 2 and 8 Gy absorbed doses. The lead shielding was fabricated into a cuboid shape with a canal on the top and a hole on the vertical side for the beam path. Respective deliveries doses of 28 and 75 Gy from gamma-cell were used to achieve 2 and 8 Gy absorbed doses at the tumour sites.