MATERIALS AND METHODS: This is a single-center, single-dose, open-label, randomized, 2-treatment, 2-sequence and 2- period crossover study with a washout period of 7 days. All 28 adult male subjects were required to fast for at least 10 hours prior to drug administration and they were given access to water ad libitum during this period. Thirty minutes prior to dosing, all subjects were served with a standardized high-fat and high-calorie breakfast with a total calorie of 1000 kcal which was in accordance to the EMA Guideline on the Investigation of Bioequivalence. Subsequently, subjects were administered either the test or reference preparation with 240mL of plain water in the first trial period. During the second trial period, they received the alternate preparation. Plasma levels of glibenclamide and metformin were analysed separately using two different high performance liquid chromatography methods.
RESULTS: The 90% confidence interval (CI) for the ratio of the AUC0-t, AUC0-∞, and Cmax of the test preparation over those of the reference preparation were 0.9693-1.0739, 0.9598- 1.0561 and 0.9220 - 1.0642 respectively. Throughout the study period, no serious drug reaction was observed. However, a total of 26 adverse events (AE)/side effects were reported, including 24 that were definitely related to the study drugs, namely giddiness (n=17), while diarrheoa (n=3), headache (n=2) and excessive hunger (n=2) were less commonly reported by the subjects.
CONCLUSION: It can be concluded that the test preparation is bioequivalent to the reference preparation.
METHODS: Xenical 120 mg capsules (Roche, Basel, Switzerland) were used as reference material. Generic products were from India, Malaysia, Argentina, Philippines, Uruguay, and Taiwan. Colour, melting temperature, crystalline form, particle size, capsule fill mass, active pharmaceutical ingredient content, amount of impurities, and dissolution were compared. Standard physical and chemical laboratory tests were those developed by Roche for Xenical.
RESULTS: All nine generic products failed the Xenical specifications in four or more tests, and two generic products failed in seven tests. A failure common to all generic products was the amount of impurities present, mostly due to different by-products, including side-chain homologues not present in Xenical. Some impurities were unidentified. Two generic products tested failed the dissolution test, one product formed a capsule-shaped agglomerate on storage and resulted in poor (=15%) dissolution. Six generic products were powder formulations.
CONCLUSIONS: All tested generic orlistat products were pharmaceutically inferior to Xenical. The high levels of impurities in generic orlistat products are a major safety and tolerability concern.
METHODS: This study was a cross-sectional nationwide survey targeting physicians from private medical centres in Malaysia. The survey was conducted using questionnaire having (i) background and demographic data of the physicians, volume of prescription in a day, stock of generic medicines in their hospital pharmacy etc. (ii) their knowledge about bioequivalence (iii) prescribing behavior (iv) physicians' knowledge of quality, safety and efficacy of generic medicines, and their cost (v) perceptions of physicians towards issues pertaining to generic medicines utilization.
RESULTS: A total of 263 questionnaires out of 735 were received, giving a response rate of 35.8%. Of the respondents, 214 (81.4%) were male and 49 (18.6%) were females. The majority of the participants were in the age range of 41-50 years and comprised 49.0% of the respondents. Only 2.3% of physicians were aware of the regulatory limits of bioequivalence standards in Malaysia. Of the respondents, 23.2% agreed that they 'always' write their prescriptions using originator product name whereas 50.2% do it 'usually'. A number of significant associations were found between their knowledge, perceptions about generic medicines and their demographic characteristics.
CONCLUSIONS: The majority of the physicians from private medical centres in Malaysia had negative perceptions about safety, quality and the efficacy of generic medicines. These negative perceptions could be the cause of the limited use of generic medicines in the private medical centres. Therefore, in order to facilitate their use, it is recommended that the physicians need to be reassured and educated about the drug regulatory authority approval system of generic medicines with regard to their bioequivalence, quality, efficacy and safety. Apart from the policy on generic substitution, it would also be recommended to have a national medicine pricing policy, which controls drug prices, in both the public and private sector. These efforts are worthwhile to reduce the drug expenditure and improve the medicine affordability in Malaysia.
SETTING: A sample of 1419 Malaysian community pharmacies with resident pharmacists.
METHOD: A cross-sectional nationwide survey using a self-completed mailing questionnaire.
MAIN OUTCOME MEASURE: Pharmacists' views on generic medicines including issues surrounding efficacy, safety, quality and bioequivalence.
RESULTS: Responses were received from 219 pharmacies (response rate 15.4%). Only 50.2% of the surveyed pharmacists agreed that all products that are approved as generic equivalents can be considered therapeutically equivalent with the innovator medicines. Around 76% of respondents indicated that generic substitution of narrow therapeutic index medicines is inappropriate. The majority of the pharmacists understood that a generic medicine must contain the same amount of active ingredient (84.5%) and must be in the same dosage form as the innovator brand (71.7%). About 21% of respondents though that generic medicines are of inferior quality compared to innovator medicines. Most of the pharmacists (61.6%) disagreed that generic medicines produce more side-effects than innovator brand. Pharmacists graduated from Malaysian universities, twinning program and overseas universities were not differed significantly in their views on generic medicines. Additionally, the respondents appeared to have difficulty in ascertaining the bioequivalent status of the marketed generic products in Malaysia.
CONCLUSION: The Malaysian pharmacists' have lack of information and/or trust in the generic manufacturing and/or approval system in Malaysia. This issue should be addressed by pharmacy educators and relevant government agencies.
MATERIALS AND METHODS: A randomized, 2-treatment, 2-period, 2-sequence, single dose, crossover with a washout period of 2 weeks, was conducted in 24 healthy Thai male volunteers. Blood samples were collected at 0, 0.25, 0.5, 0.75, 1, 1.25, 1.5, 1.75, 2, 2.5, 3, 3.5, 4, 5, 6, 8, 10, 12, 24, 36, 48, 72 and 96 h following drug administration. Plasma concentrations of risperidone and 9-hydroxyrisperidone were determined using a validated LC-MS-MS method. The pharmacokinetic parameters of risperidone and 9-hydroxyrisperidone were determined using a non-compartmental model.
RESULTS: The geometric means ratios (%) and 90% confidence interval (CI) of the test and reference products for the log-transformed pharmacokinetic parameters, Cmax, AUC0-t and AUC0-inf of risperidone were 104.49 % (92.79% - 117.66%), 100.96 % (92.15% - 110.61 %) and 97.99 % (90.72% - 105.85%). The 90% CI of geometric means ratios of the test and reference products for the log-transformed pharmacokinetic parameters, Cmax, AUC0-t and AUC0-inf of 9-hydroxyrisperidone were 97.00%, 96.97% and 97.49%.
CONCLUSIONS: The 90% CI for the geometric means ratios (test/reference) of the log-trasformed Cmax, AUC0-t and AUC0-inf of risperidone and its major active metabolite were within the bioequivalence acceptance criteria of 80% - 125% of the US-FDA.