METHODS: Hypercholesterolemic individuals (n = 103) were selected from the Malaysian Cohort project (UKM Medical Molecular Biology Institute) while the control samples were selected from the Biobank (UKM Medical Molecular Biology Institute). The DNA samples were isolated from whole blood. Polymerase chain reaction (PCR) amplification process was performed using bifunctional labelled primers specifically designed to correspond to the variant that differentiates wild-type and mutant DNA for visual detection on LFA. The variant was confirmed using Sanger sequencing, and the sensitivity and specificity of the LFA detection method were validated using the Agena MassARRAY® technique.
RESULTS: Out of 103 hypercholesterolemic individuals, 5 individuals (4.8%) tested positive for E101K, LDLR mutation and the rest, including healthy control individuals, tested negative. This result was concordant with Sanger sequencing and Agena MassARRAY®. These five individuals could be classified as Definite FH, as the DNA diagnosis was confirmed. The sensitivity and specificity of the variant detection by LFA is 100% compared to results using the genotyping method using Agena MassARRAY®.
CONCLUSION: The developed LFA can potentially be used in the POC setting for detecting the E101K variant in the LDLR gene. This LFA can also be used to screen family members with E101K variant in the LDLR gene and is applicable for other SNP's detection.
METHODOLOGY: A total of 571 healthcare workers at COVID-19 and non-COVID-19 wards as well as the emergency department and laboratory staff at COVID-19 testing labs were recruited. The presence of novel human coronavirus (SARS-CoV-2) and IgM/IgG antibodies were confirmed in all healthcare workers. The healthcare workers responded to an online Google Forms questionnaire that evaluates demographic information and comorbidities, exposure and adherence to infection prevention and control measures against COVID-19. Descriptive analysis was performed using Statistical Package for the Social Sciences 24.0.
RESULTS: Three healthcare workers (0.5%) tested positive for SARS-CoV-2, while the remaining 568 (99.5%) were negative. All were negative for IgM and IgG antibodies during recruitment (day 1) and follow-up (day 15). More than 90% of the healthcare workers followed infection prevention and control practices recommendations regardless of whether they have been exposed to occupational risk for COVID-19.
CONCLUSIONS: The healthcare workers' high level of adherence to infection prevention practices at this hospital helped reduce and minimize their occupational exposure to COVID-19.