METHODS: Thirty-nine eyes from 39 patients with a FTMH <600 μm were included from a single institution. All patients underwent vitrectomy using a semicircular single-layered ILM inverted flap assisted by a sub-perfluorocarbon liquid injection of ophthalmic viscoelastic device (OVD) technique. Best-corrected visual acuity (BCVA) and spectral domain optical coherence tomography were used to compare outcomes between nasal (n = 19) and temporal (n = 20) groups.
RESULTS: At 6 months postoperatively, all FTMHs closed and BCVA were significantly improved. Overall, 36 eyes (92%) achieved U-shaped closure, and ellipsoid zone restoration was noted in 24 eyes (62%). An ILM flap was present in 29 eyes (74%) and 86% remained single-layered. There were significantly more deep inner retinal dimples in the temporal group (35%) compared with 5% in the nasal group (P = .04), but these were unrelated to BCVA. Significant retinal thinning in the temporal outer sub-field was noted in the temporal group and was negatively correlated with BCVA (rho [ρ]: - .53; P = .03). No significant postoperative retinal displacement was noted in either group.
CONCLUSIONS: The technique of using sub-perfluorocarbon liquid injection of OVD secured single-layered flaps intraoperatively and postoperatively. Both the nasal and temporal inverted ILM flaps repaired FTMH and improved visual acuity. However, both temporal macular thinning and deep inner retinal dimples were significantly greater in the temporal group.
METHODS: We present 2 cases in which we encountered premature intravascular detachment of the microcatheter tip and coil migration while treating a dural arteriovenous fistula and aneurysm, respectively. We used a stentriever to remove the detached microcatheter tip and suction using the reperfusion catheter to remove the migrated coil, both techniques that have not been reported in the literature thus far.
RESULTS: Detached microcatheter tip and migrated coil were successfully retrieved using a stentriever and aspiration catheter.
CONCLUSIONS: These novel techniques could potentially reduce mortality and morbidity associated with neurointervention.
METHODS: This is a prospective observational study of 201 patients who underwent endoscopic nasojejunal wire-guided feeding tube insertions for obstruction of either the esophagus or the stomach including both benign and malignant pathologies between January 2015 to June 2018 in Hospital Sungai Buloh and Hospital Sultanah Aminah, Malaysia. The indications for tube insertion, insertion technique, and tube-related problems were described.
RESULTS: The nasojejunal tube was used to establish enteral feeding in patients with obstructing tumors of the distal esophagus in 65 patients (32.3%) and gastric outlet obstruction in 72 patients (35.8%). There were 54 patients (26.9%) who required reinsertion. The most common reason for reinsertion was unintentional dislodgement, where 32 patients (15.9%) followed by tube blockage 20 patients (10.0%). Using our method of advancement under direct vision, we had only 2 cases of malposition due to severely deformed anatomy. We had no incidence of aspiration in this group of patients and overall, the patients tolerated the tube well.
CONCLUSIONS: The novel nasojejunal feeding tube with gastric decompression function is a safe and effective method of delivery of enteral nutrition in patients with upper gastrointestinal obstruction. These tubes if inserted properly are well tolerated with almost no risk of malposition and are tolerated well even for prolonged periods of time until definitive surgery could be performed.