Displaying publications 301 - 320 of 364 in total

Abstract:
Sort:
  1. C Thambiah S, Meor Anuar Shuhaili MFR, Chew BH, Samsudin IN, Abdul Rahman H, Stanslas J, et al.
    Biomarkers, 2019 Nov;24(7):659-665.
    PMID: 31342800 DOI: 10.1080/1354750X.2019.1648554
    Introduction: Statin, the first-line treatment for dyslipidaemia, may have suboptimal adherence due to its associated muscle adverse events. These data, however, remain limited. Aim: To determine the association of serum creatine kinase (CK) and SLCO1B1 rs4363657 polymorphism with statin-associated muscle adverse events (SAMAE) among dyslipidaemia participants.
    Methods: This was a prospective cohort study at government health clinics involving newly diagnosed adults with dyslipidaemia. SAMAE were recorded based on the patient's complaint after a month on statin. CK was taken at baseline and follow-up. Genetic profiling was performed for SLCO1B1 rs4363657 polymorphism.
    Results: Among 118 participants, majority were Malay (72%) males (61%) with a mean age of 49 ± 12.2 years old and prescribed lovastatin (61.9). There was a significant association between statin types (lovastatin and simvastatin) and SAMAE (p = 0.0327); no significant association noted between CK and SAMAE (p = 0.5637). The SLCO1B1 rs4363657 polymorphism was significantly associated SAMAE (p 
  2. Teoh BY, Lim YM, Chong WY, Subramaniam M, Tan ZZ, Misran M, et al.
    Biomed Microdevices, 2022 Jan 26;24(1):12.
    PMID: 35080702 DOI: 10.1007/s10544-022-00609-z
    Isolation of exosome from culture medium in an effective way is desired for a less time consuming, cost saving technology in running the diagnostic test on cancer. In this study, we aim to develop an inertial microfluidic channel to separate the nano-size exosome from C666-1 cell culture medium as a selective sample. Simulation was carried out to obtain the optimum flow rate for determining the dimension of the channels for the exosome separation from the medium. The optimal dimension was then brought forward for the actual microfluidic channel fabrication, which consisted of the stages of mask printing, SU8 mould fabrication and ended with PDMS microchannel curing process. The prototype was then used to verify the optimum flow rate with polystyrene particles for its capabilities in actual task on particle separation as a control outcome. Next, the microchip was employed to separate the selected samples, exosome from the culture medium and compared the outcome from the conventional exosome extraction kit to study the level of effectiveness of the prototype. The exosome outcome from both the prototype and extraction kits were characterized through zetasizer, western blot and Transmission electron microscopy (TEM). The microfluidic chip designed in this study obtained a successful separation of exosome from the culture medium. Besides, the extra benefit from this microfluidic channels in particle separation brought an evenly distributed exosome upon collection while the exosomes separated through extraction kit was found clustered together. Therefore, this work has shown the microfluidic channel is suitable for continuous separation of exosome from the culture medium for a clinical study in the future.
  3. Yusoff J, Ismail A, Abd Manaf MR, Ismail F, Abdullah N, Muhammad R, et al.
    Health Qual Life Outcomes, 2022 Jan 29;20(1):15.
    PMID: 35093066 DOI: 10.1186/s12955-022-01921-1
    BACKGROUND: Quality of life (QoL) is one of the treatment outcome measures in patients with breast cancer. In this study, we measured the QoL of women with breast cancer at Universiti Kebangsaan Malaysia Medical Centre (UKMMC) and identified the associated factors.

    METHODOLOGY: This cross-sectional study was conducted from October 2017 to December 2017 and involved female patients with breast cancer. The QoL scores and domains were determined using the EuroQol EQ-5D-5L, and were presented as the utility value and visual analog scores, respectively.

    RESULTS: We recruited a total of 173 women, aged 33-87 years. The median VA score was 80.00 (interquartile range [IQR] 70.00-90.00); the median utility value was 0.78 (interquartile range [IQR] 0.65-1.00. Women who did not take traditional medicine had a higher utility index score of 0.092 (95% CI 0.014-0.171), and women with household income of RM3000-5000 had a higher utility index score of 0.096 (95% CI 0.011-0.180).

    CONCLUSION: Traditional medicine consumption and household income were significantly associated with lower QoL. The pain/discomfort domain was the worst affected QoL domain and was related to traditional medicine use and household income. Addressing pain management in patients with breast cancer and the other factors contributing to lower QoL may improve the QoL of breast cancer survivors in the future.

  4. Tan SK, Yeong CH, Raja Aman RRA, Ng KH, Abdul Aziz YF, Chee KH, et al.
    Br J Radiol, 2018 Jul;91(1088):20170874.
    PMID: 29493261 DOI: 10.1259/bjr.20170874
    OBJECTIVE: This study aimed (1) to perform a systematic review on scanning parameters and contrast medium (CM) reduction methods used in prospectively electrocardiography (ECG-triggered low tube voltage coronary CT angiography (CCTA), (2) to compare the achievable dose reduction and image quality and (3) to propose appropriate scanning techniques and CM administration methods.

    METHODS: A systematic search was performed in PubMed, the Cochrane library, CINAHL, Web of Science, ScienceDirect and Scopus, where 20 studies were selected for analysis of scanning parameters and CM reduction methods.

    RESULTS: The mean effective dose (HE) ranged from 0.31 to 2.75 mSv at 80 kVp, 0.69 to 6.29 mSv at 100 kVp and 1.53 to 10.7 mSv at 120 kVp. Radiation dose reductions of 38 to 83% at 80 kVp and 3 to 80% at 100 kVp could be achieved with preserved image quality. Similar vessel contrast enhancement to 120 kVp could be obtained by applying iodine delivery rate (IDR) of 1.35 to 1.45 g s-1 with total iodine dose (TID) of between 10.9 and 16.2 g at 80 kVp and IDR of 1.08 to 1.70 g s-1 with TID of between 18.9 and 20.9 g at 100 kVp.

    CONCLUSION: This systematic review found that radiation doses could be reduced to a rate of 38 to 83% at 80 kVp, and 3 to 80% at 100 kVp without compromising the image quality. Advances in knowledge: The suggested appropriate scanning parameters and CM reduction methods can be used to help users in achieving diagnostic image quality with reduced radiation dose.

  5. Abdul Hadi MFR, Abdullah AN, Hashikin NAA, Ying CK, Yeong CH, Yoon TL, et al.
    Med Phys, 2022 Dec;49(12):7742-7753.
    PMID: 36098271 DOI: 10.1002/mp.15980
    PURPOSE: Monte Carlo (MC) simulation is an important technique that can help design advanced and challenging experimental setups. GATE (Geant4 application for tomographic emission) is a useful simulation toolkit for applications in nuclear medicine. Transarterial radioembolization is a treatment for liver cancer, where microspheres embedded with yttrium-90 (90 Y) are administered intra-arterially to the tumor. Personalized dosimetry for this treatment may provide higher dosimetry accuracy compared to the conventional partition model (PM) calculation. However, incorporation of three-dimensional tomographic input data into MC simulation is an intricate process. In this article, 3D Slicer, free and open-source software, was utilized for the incorporation of patient tomographic images into GATE to demonstrate the feasibility of personalized dosimetry in hepatic radioembolization with 90 Y.

    METHODS: In this article, the steps involved in importing, segmenting, and registering tomographic images using 3D Slicer were thoroughly described, before importing them into GATE for MC simulation. The absorbed doses estimated using GATE were then compared with that of PM. SlicerRT, a 3D Slicer extension, was then used to visualize the isodose from the MC simulation.

    RESULTS: A workflow diagram consisting of all the steps taken in the utilization of 3D Slicer for personalized dosimetry in 90 Y radioembolization has been presented in this article. In comparison to the MC simulation, the absorbed doses to the tumor and normal liver were overestimated by PM by 105.55% and 20.23%, respectively, whereas for lungs, the absorbed dose estimated by PM was underestimated by 25.32%. These values were supported by the isodose distribution obtained via SlicerRT, suggesting the presence of beta particles outside the volumes of interest. These findings demonstrate the importance of personalized dosimetry for a more accurate absorbed dose estimation compared to PM.

    CONCLUSION: The methodology provided in this study can assist users (especially students or researchers who are new to MC simulation) in navigating intricate steps required in the importation of tomographic data for MC simulation. These steps can also be utilized for other radiation therapy related applications, not necessarily limited to internal dosimetry.

  6. Yi Liang T, Zakaria NF, Kasjoo SR, Shaari S, Mohamad Isa M, Md Arshad MK, et al.
    Sensors (Basel), 2022 Dec 11;22(24).
    PMID: 36560080 DOI: 10.3390/s22249712
    The rapid growth of wireless technology has improved the network's technology from 4G to 5G, with sub-6 GHz being the centre of attention as the primary communication spectrum band. To effectively benefit this exclusive network, the improvement in the mm-wave detection of this range is crucial. In this work, a silicon self-switching device (SSD) based full-wave bridge rectifier was proposed as a candidate for a usable RF-DC converter in this frequency range. SSD has a similar operation to a conventional pn junction diode, but with advantages in fabrication simplicity where it does not require doping and junctions. The optimized structure of the SSD was cascaded and arranged to create a functional full-wave bridge rectifier with a quadratic relationship between the input voltage and outputs current. AC transient analysis and theoretical calculation performed on the full-wave rectifier shows an estimated cut-off frequency at ~12 GHz, with calculated responsivity and noise equivalent power of 1956.72 V/W and 2.3753 pW/Hz1/2, respectively. These results show the capability of silicon SSD to function as a full-wave bridge rectifier and is a potential candidate for RF-DC conversion in the targeted 5G frequency band and can be exploited for future energy harvesting application.
  7. Ibrahim AA, Ahmad Zamzuri M'I, Ismail R, Ariffin AH, Ismail A, Muhamad Hasani MH, et al.
    Medicine (Baltimore), 2022 Jul 29;101(30):e29627.
    PMID: 35905245 DOI: 10.1097/MD.0000000000029627
    The Teleprimary Care-Oral Health Clinical Information System (TPC-OHCIS) is an updated electronic medical record (EMR) that has been applied in Malaysian primary healthcare. Recognizing the level of patient satisfaction following EMR implementation is crucial for assessing the performance of health care services. Hence, the main objective of this study was to compare the level of patient satisfaction between EMR-based clinics and paper-based clinics. The study was a quasi-experimental design that used a control group and was conducted among patients in 14 public primary healthcare facilities in the Seremban district of Malaysia from May 10, to June 30, 2021. Patient satisfaction was assessed using the validated Short-Form Patient Satisfaction Questionnaire, which consisted of 7 subscales. All data were analyzed using the IBM Statistical Package for Social Sciences version 21. A total of 321 patients consented to participate in this study, and 48.9% of them were from EMR clinics. The mean score for the communication subscale was the highest at 4.08 and 3.96 at EMR-adopted clinics and paper-based record clinics. There were significant differences in general satisfaction and communication subscales, with higher patient satisfaction found in clinics using EMR. With the utilization of EMR, patient satisfaction and communication in delivering healthcare services have improved.
  8. Salvaraji L, Shamsudin SB, Avoi R, Saupin S, Kim Sai L, Asan SB, et al.
    Int J Environ Res Public Health, 2022 Dec 19;19(24).
    PMID: 36554980 DOI: 10.3390/ijerph192417099
    INTRODUCTION: Persistent exposure to indoor hazards in a healthcare setting poses a risk of SBS. This study determines the prevalence of and risk factors for SBS among healthcare workers in health clinics.

    METHODS: A cross-sectional study was conducted across four health clinics from February 2022 to May 2022. As part of the study, self-administered questionnaires were completed to determine symptoms related to SBS. An indoor air quality (IAQ) assessment was conducted four times daily for fifteen minutes at five areas in each clinic (laboratory, lobby, emergency room, pharmacy, and examination room).

    RESULT: Most of the areas illustrated poor air movement (<0.15 m/s), except for the laboratory. The total bacterial count (TBC) was above the standard limit in both the lobby and emergency room (>500 CFU/m3). The prevalence of SBS was 24.84% (77) among the healthcare workers at the health clinics. A significant association with SBS was noted for those working in the examination room (COR = 2.86; 95% CI = 1.31; 6.27) and those experiencing high temperature sometimes (COR = 0.25; 95% CI = 0.11; 0.55), varying temperature sometimes (COR = 0.31; 95% CI = 0.003), stuffy air sometimes (COR = 0.17; 95% CI = 0.005; 0.64), dry air sometimes (COR = 0.20; 95% CI = 0.007; 0.64), and dust sometimes (COR = 0.25; 95% CI = 0.11; 0.60) and everyday (COR = 0.34; 95% CI = 0.14; 0.81). Only healthcare workers in the examination room (AOR = 3.17; 95% CI = 1.35; 7.41) were found to have a significant risk of SBS when controlling for other variables.

    CONCLUSION: SBS is prevalent among healthcare workers at health clinics.

  9. Tok PSK, Kamarudin N', Jamaludin M, Ab Razak MF, Ahmad MAS, Abu Bakar FA, et al.
    Infect Dis (Lond), 2022 Mar;54(3):235-237.
    PMID: 34772327 DOI: 10.1080/23744235.2021.2000636
  10. Li Tee CC, Chong MC, Sundar V, Chok CL, Md Razali MR, Yeo WK, et al.
    Eur J Sport Sci, 2023 Aug;23(8):1581-1590.
    PMID: 35912915 DOI: 10.1080/17461391.2022.2109066
    Acute physiological, perceptual and biomechanical consequences of manipulating both exercise intensity and hypoxic exposure during treadmill running were determined. On separate days, eleven trained individuals ran for 45 s (separated by 135 s of rest) on an instrumented treadmill at seven running speeds (8, 10, 12, 14, 16, 18 and 20 km.h-1) in normoxia (NM, FiO2 = 20.9%), moderate hypoxia (MH, FiO2 = 16.1%), high hypoxia (HH, FiO2 = 14.1%) and severe hypoxia (SH, FiO2 = 13.0%). Running mechanics were collected over 20 consecutive steps (i.e. after running ∼25 s), with concurrent assessment of physiological (heart rate and arterial oxygen saturation) and perceptual (overall perceived discomfort, difficulty breathing and leg discomfort) responses. Two-way repeated-measures ANOVA (seven speeds × four conditions) were used. There was a speed × condition interaction for heart rate (p = 0.045, ηp2 = 0.22), with lower values in NM, MH and HH compared to SH at 8 km.h-1 (125 ± 12, 125 ± 11, 128 ± 12 vs 132 ± 10 b.min-1). Overall perceived discomfort (8 and 16 km.h-1; p = 0.019 and p = 0.007, ηp2  = 0.21, respectively) and perceived difficulty breathing (all speeds; p = 0.023, ηp2  = 0.37) were greater in SH compared to MH, whereas leg discomfort was not influenced by hypoxic exposure. Minimal difference was observed in the twelve kinetics/kinematics variables with hypoxia (p > 0.122; ηp2 = 0.19). Running at slower speeds in combination with severe hypoxia elevates physiological and perceptual responses without a corresponding increase in ground reaction forces.Highlights The extent to which manipulating hypoxia severity (between normoxia and severe hypoxia) and running speed (from 8 to 20 km.h-1) influence acute physiological and perceptual responses, as well as kinetic and kinematic adjustments during treadmill running was determined.Running at slower speeds in combination with severe hypoxia elevates heart rate, while this effect was not apparent at faster speeds.Arterial oxygen saturation was increasingly lower as running speed and hypoxic severity increased.Overall perceived discomfort (8 and 16 km.h-1) and perceived difficulty breathing (all speeds) were lower in moderate hypoxia than in severe hypoxia, whereas leg discomfort remained unchanged with hypoxic exposure.
  11. Abu Bakar MS, Syamsir A, Alhayek A, Asyraf MRM, Itam Z, Shaik SMM, et al.
    Materials (Basel), 2023 Jul 29;16(15).
    PMID: 37570032 DOI: 10.3390/ma16155328
    This paper presents an experimental and numerical investigation of pultruded composite glass fibre-reinforced polymer (pGFRP) cross-arms subjected to flexural creep behaviour to assess their performance and sustainability in composite cross-arm structure applications. The primary objective of this study was to investigate the failure creep behaviour of pGFRP cross-arms with different stacking sequences. Specifically, the study aimed to understand the variations in strain rate exhibited during different stages of the creep process. Therefore, this study emphasizes a simplified approach within the experiment, numerical analysis, and mathematical modelling of three different pGFRP composites to estimate the stiffness reduction factors that determine the prediction of failure. The findings show that Findley's power law and the Burger model projected very different strains and diverged noticeably outside the testing period. Findley's model estimated a minimal increase in total strain over 50 years, while the Burger model anticipated PS-1 and PS-2 composites would fail within about 11 and 33 years, respectively. The Burger model's forecasts might be more reasonable due to the harsh environment the cross-arms are expected to withstand. The endurance and long-term performance of composite materials used in overhead power transmission lines may be predicted mathematically, and this insight into material property factors can help with design and maintenance.
  12. Ibrahim A, Ali RAR, Manaf MRA, Ahmad N, Tajurruddin FW, Qin WZ, et al.
    PLoS One, 2020;15(12):e0244680.
    PMID: 33382780 DOI: 10.1371/journal.pone.0244680
    OBJECTIVE: We determined the effectiveness of a multi-strain probiotic (Hexbio®) containing microbial cell preparation MCP®BCMC® on constipation symptoms and gut motility in PD patients with constipation.

    METHODS: PD patients with constipation (ROME III criteria) were randomized to receive a multi-strain probiotic (Lactobacillus sp and Bifidobacterium sp at 30 X 109 CFU) with fructo-oligosaccaride or placebo (fermented milk) twice daily for 8 weeks. Primary outcomes were changes in the presence of constipation symptoms using 9 items of Garrigues Questionnaire (GQ), which included an item on bowel opening frequency. Secondary outcomes were gut transit time (GTT), quality of life (PDQ39-SI), motor (MDS-UPDRS) and non-motor symptoms (NMSS).

    RESULTS: Of 55 recruited, 48 patients completed the study: 22 received probiotic and 26 received placebo. At 8 weeks, there was a significantly higher mean weekly BOF in the probiotic group compared to placebo [SD 4.18 (1.44) vs SD 2.81(1.06); (mean difference 1.37, 95% CI 0.68, 2.07, uncorrected p<0.001)]. Patients in the probiotic group reported five times higher odds (odds ratio = 5.48, 95% CI 1.57, 19.12, uncorrected p = 0.008) for having higher BOF (< 3 to 3-5 to >5 times/week) compared to the placebo group. The GTT in the probiotic group [77.32 (SD55.35) hours] reduced significantly compared to placebo [113.54 (SD 61.54) hours]; mean difference -36.22, 95% CI -68.90, -3.54, uncorrected p = 0.030). The mean change in GTT was 58.04 (SD59.04) hour vs 20.73 (SD60.48) hours respectively (mean difference 37.32, 95% CI 4.00, 70.63, uncorrected p = 0.028). No between-groups differences were observed in the NMSS, PDQ39-SI, MDS-UPDRS II and MDS-UPDRS III scores. Four patients in the probiotics group experienced mild reversible side effects.

    CONCLUSION: This study showed that consumption of a multi-strain probiotic (Hexbio®) over 8 weeks improved bowel opening frequency and whole gut transit time in PD patients with constipation.

  13. Irfandi R, Raya I, Ahmad A, Fudholi A, Santi S, Puspa Azalea W, et al.
    J Biomol Struct Dyn, 2023;41(22):12938-12950.
    PMID: 36690606 DOI: 10.1080/07391102.2023.2169764
    Breast cancer continues to be a major health issue for women all over the world. Cancer medications like cisplatin, which are widely used, still have negative side effects. The novel complex was created as a potential anticancer medication candidate that is both effective and safe, with few side effects. The Cu(II) complex using the prolinedithiocarbamate ligands was synthesized in situ. The Cu(II) complexes Characterization by UV-Vis, FT-IR spectroscopy and melting point determination, conductivity, and HOMO-LUMO were studied. Computational NMR spectrum analysis was performed. The interaction of Cu(II)prolineditiocarbamate complex with cancer cell target protein (MCF-7) was confirmed by molecular docking and molecular dynamic. The pharmacokinetic/ADMET properties were also performed on the complex. Results of the cytotoxic complex test against cancer cells (MCF-7) undergoing apoptosis with an IC50 value of 13.64 µg/mL showed high anticancer activity in MCF-7 cancer cells. The in-vivo data for Cu(II)prolineditiocarbamate complex was predicted using the Protox online tool with an LD50 value of 2500 mg/kg and belonging to the GHS toxicity class 5, which means the compound has a low acute toxicity effect. The Cu(II) prolineitiocarbamate complex may pave the way for the development of essential metal-based chemotherapy for the treatment of breast cancer.Communicated by Ramaswamy H. Sarma.
  14. Fum WKS, Md Shah MN, Raja Aman RRA, Abd Kadir KA, Wen DW, Leong S, et al.
    Phys Eng Sci Med, 2023 Dec;46(4):1535-1552.
    PMID: 37695509 DOI: 10.1007/s13246-023-01317-5
    In fluoroscopy-guided interventions (FGIs), obtaining large quantities of labelled data for deep learning (DL) can be difficult. Synthetic labelled data can serve as an alternative, generated via pseudo 2D projections of CT volumetric data. However, contrasted vessels have low visibility in simple 2D projections of contrasted CT data. To overcome this, we propose an alternative method to generate fluoroscopy-like radiographs from contrasted head CT Angiography (CTA) volumetric data. The technique involves segmentation of brain tissue, bone, and contrasted vessels from CTA volumetric data, followed by an algorithm to adjust HU values, and finally, a standard ray-based projection is applied to generate the 2D image. The resulting synthetic images were compared to clinical fluoroscopy images for perceptual similarity and subject contrast measurements. Good perceptual similarity was demonstrated on vessel-enhanced synthetic images as compared to the clinical fluoroscopic images. Statistical tests of equivalence show that enhanced synthetic and clinical images have statistically equivalent mean subject contrast within 25% bounds. Furthermore, validation experiments confirmed that the proposed method for generating synthetic images improved the performance of DL models in certain regression tasks, such as localizing anatomical landmarks in clinical fluoroscopy images. Through enhanced pseudo 2D projection of CTA volume data, synthetic images with similar features to real clinical fluoroscopic images can be generated. The use of synthetic images as an alternative source for DL datasets represents a potential solution to the application of DL in FGIs procedures.
  15. Ismail UN, Azlan CA, Khairullah S, Azman RR, Omar NF, Md Shah MN, et al.
    J Magn Reson Imaging, 2024 Mar 31.
    PMID: 38556790 DOI: 10.1002/jmri.29366
    BACKGROUND: Growing evidence suggests that marrow adipocytes play an active role in the regulation of bone metabolism and hematopoiesis. However, research on the relationship between bone and fat in the context of hematological diseases, particularly β-thalassemia, remains limited.

    PURPOSE: To investigate the relationship between marrow fat and cortical bone thickness in β-thalassemia and to identify key determinants influencing these variables.

    STUDY TYPE: Prospective.

    SUBJECTS: Thirty-five subjects in four subject groups of increasing disease severity: 6 healthy control (25.0 ± 5.3 years, 2 male), 4 β-thalassemia minor, 13 intermedia, and 12 major (29.1 ± 6.4 years, 15 male).

    FIELD STRENGTH/SEQUENCE: 3.0 T, 3D fast low angle shot sequence and T1-weighted turbo spin echo.

    ASSESSMENT: Analyses on proton density fat fraction (PDFF) and R2* values in femur subregions (femoral head, greater trochanter, intertrochanteric, diaphysis, distal) and cortical thickness (CBI) of the subjects' left femur. Clinical data such as age, sex, body mass index (BMI), and disease severity were also included.

    STATISTICAL TESTS: One-way analysis of variance (ANOVA), mixed ANOVA, Pearson correlation and multiple regression. P-values <0.05 were considered significant.

    RESULTS: Bone marrow PDFF significantly varied between the femur subregions, F(2.89,89.63) = 44.185 and disease severity, F(1,3) = 12.357. A significant interaction between subject groups and femur subregions on bone marrow PDFF was observed, F(8.67,89.63) = 3.723. Notably, a moderate positive correlation was observed between PDFF and CBI (r = 0.33-0.45). Multiple regression models for both PDFF (R2 = 0.476, F(13,151) = 10.547) and CBI (R2 = 0.477, F(13,151) = 10.580) were significant. Significant predictors for PDFF were disease severity (βTMi = 0.36, βTMa = 0.17), CBI (β = 0.24), R2* (β = -0.32), and height (β = -0.29) while for CBI, the significant determinants were sex (β = -0.27), BMI (β = 0.55), disease severity (βTMi = 2.15), and PDFF (β = 0.25).

    DATA CONCLUSION: This study revealed a positive correlation between bone marrow fat fraction and cortical bone thickness in β-thalassemia with varying disease severity, potentially indicating a complex interplay between bone health and marrow composition.

    EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 3.

  16. Kow RY, Abdul Rani R, Mohamad Nazarallah MH, Leong JF, Hayyun MF, Low CL, et al.
    Cureus, 2024 Mar;16(3):e56617.
    PMID: 38646377 DOI: 10.7759/cureus.56617
    Robotic-assisted hip and knee arthroplasty represents cutting-edge advancements in orthopedic surgery, harnessing robotic technology to enhance precision, improve clinical outcomes, and facilitate intra-operative procedures. In these robotic-assisted surgeries, the robotic systems assist surgeons in planning and executing joint replacement surgeries, thereby facilitating personalized implant positioning and optimizing the fit and alignment of hip and knee implants. Despite the increasing attention garnered by robotic-assisted hip and knee arthroplasty in recent years, a comprehensive bibliometric analysis using the Scopus database has yet to be conducted. This bibliometric analysis reviews the Scopus database from 1961 until 2022 to investigate the literature on the field of robotic-assisted hip and knee arthroplasty. A total of 577 articles that satisfied the selection criteria were included in this review. The majority of the articles focus more on total knee replacement, compared to total hip replacement and unicompartmental knee arthroplasty. The overwhelming majority of the articles were authored by researchers and clinicians from the United States of America (USA) and the United Kingdom (UK). Similarly, most of the articles with the highest number of citations were authored by researchers and clinicians from these regions. This comprehensive bibliometric analysis using Scopus in the domain of robotic-assisted hip and knee replacement has the potential to act as a roadmap for researchers, clinicians, and policymakers, facilitating informed decision-making, promoting collaborative initiatives, and guiding the development of future studies to further advance the field of robotic-assisted hip and knee arthroplasty.
  17. Ooi ECW, Isa ZM, Manaf MRA, Fuad ASA, Ahmad A, Mustapa MN, et al.
    Sci Rep, 2024 Apr 30;14(1):9926.
    PMID: 38688966 DOI: 10.1038/s41598-024-60439-2
    The transition of ICD has never been a straightforward initiative. As nations transition to ICD-11, ensuring its acceptance among the users is essential. To our knowledge, there are limited studies about the instrument and ICD-11 adoption. Therefore, the purpose of this study was to design an instrument and investigate the factors influencing the intention to use the ICD-11 among medical record officers (MROs) and assistant medical record officers (AMROs) at Ministry of Health (MOH) Malaysia facilities. Based on the current literature, a model based on the decomposed theory of planned behaviour (DTPB) was proposed. The model consisted of 13 dimensions and 12 hypotheses identified from previous studies. Using PLS-SEM, 185 survey data points were analysed. The study findings showed that ten factors have a significant impact on the suggested model. Users' subjective norm was the most influential factor in their intention to use ICD-11. Unexpectedly, perceived usefulness and was found to have no significant influence. This study is important for policymakers in strategising ICD-11 implementation efforts. This study's novelty lies in applying a DTPB theory model in the context of the intention to use ICD-11.
  18. Surendra NK, Abdul Manaf MR, Hooi LS, Bavanandan S, Mohamad Nor FS, Shah Firdaus Khan S, et al.
    BMC Nephrol, 2019 04 30;20(1):151.
    PMID: 31039745 DOI: 10.1186/s12882-019-1326-x
    BACKGROUND: Health related quality of life (HRQOL) is an important predictor of clinical outcomes for End Stage Renal Disease (ESRD) patients and to establish quality adjusted life years (QALYs) for economic evaluation studies. This study aims to measure the health utilities and to identify socio-demographic and clinical factors associated with HRQOL for haemodialysis (HD) and continuous ambulatory peritoneal dialysis (CAPD) in Malaysia.

    METHODS: A total of 141 patients (77 HD and 64 CAPD) from 1 federal and four state hospitals participated in this cross-sectional study. Patients were randomly selected from the National Renal Registry (NRR) using a stratified random sampling. The EQ-5D-3 L questionnaire was used to measure HRQOL. Variables investigated include dialysis modalities, sociodemographic characteristics, co-morbidities and biochemical markers. Utilities are measured on an ordinal scale of 0-1, where 1 indicates full health and 0 indicates death.

    RESULTS: The mean utility scores were 0.854 ± 0.181 and 0.905 ± 0.124 (p > 0.05) and the mean Visual Analogue Scale (VAS) scores were 76.2 ± 12.90 and 77.1 ± 10.26 (p > 0.05) for HD and CAPD patients respectively. There was a significant difference in problems reported between HD (35.1%) and CAPD (15.6%) on usual activities dimension (p = 0.009). The proportion of patients having problems in the pain/discomfort domain in both modalities was high (34.0%). Haemoglobin (

  19. Haron NH, Mohamad Hanif EA, Abdul Manaf MR, Yaakub JA, Harun R, Mohamed R, et al.
    Asian Pac J Cancer Prev, 2019 Feb 26;20(2):509-517.
    PMID: 30803214
    Introduction: Microsatellite instability (MSI) is a hallmark of defective DNA mismatch repair (MMR) of genes especially MLH1 and MSH2. It is frequently involved in the carcinogenesis of various tumours including gastric cancer (GC). However, MSI in GCs have not been reported in Malaysia before. Objective: This study was conducted to determine the microsatellite instability (MSI) status in gastric cancer by microsatellite analysis, sequencing, its association with MLH1 and MSH2 protein expression and H.pylori infection by immunohistochemistry. Method: A total of 60 gastric cancer cases were retrieved. DNA was extracted from paired normal and tumour tissues while MLH1 and MSH2 protein expression as well as H. pylori status were determined by IHC staining. For microsatellite analysis, polymerase chain reaction (PCR) was performed for paired tissue samples using a panel of five microsatellite markers. MSI-positive results were subjected for DNA sequencing to assess mutations in the MLH1 and MSH2 genes. Results: Microsatellite analysis identified ten MSI positive cases (16.7%), out of which only six cases (10.3%) showed absence of MLH1 (n=3) or MSH2 (n=3) protein expression by IHC. The most frequent microsatellite marker in MSI positive cases was BAT26 (90%). Nine of ten MSI positive cases were intestinal type with one diffuse and all were located distally. H. pylori infection was detected in 13 of 60 cases (21.7%) including in three MSI positive cases. All these results however were not statistically significant. Our sequencing data displayed novel mutations. However these data were not statistically correlated with expression levels of MLH1 and MSH2 proteins by IHC. This may be due to small sample size to detect small or moderately sized effects. Conclusion: The frequency of MSI in this study was comparable with published results. Determination of affected MMR genes by more than two antibodies may increase the sensitivity of IHC to that of MSI analysis.
  20. Abdul Kadir NB, Ismail WNK, Abdullah NA, Helma R, Abdul Jalil SJ, Che Kasim A, et al.
    Int J Environ Res Public Health, 2021 Oct 03;18(19).
    PMID: 34639710 DOI: 10.3390/ijerph181910410
    The aim of this study was to validate the Short Multidimensional Inventory Lifestyle Evaluation-Confinement (SMILE-C) in a Malaysian context. The SMILE-C, which is a respondent-generated instrument, was used to ask participants questions on their lifestyle during the COVID-19 pandemic. The indices of seven sub-scores were then calculated. A total of 121 university staff members completed the Malay version of the SMILE-C as well as instruments for measuring well-being, family life satisfaction, mindfulness and awareness, work engagement, and quality of life. The Cronbach's alpha values and Pearson correlation coefficients were satisfactory in this initial validation of the instrument. The SMILE-C showed positive correlations with all the variables being studied. The results supported the criterion-related validity and psychometric properties of the Malay version of the SMILE-C as an instrument for assessing lifestyle changes during the COVID-19 pandemic.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links