Displaying publications 301 - 320 of 712 in total

Abstract:
Sort:
  1. Gazzali AM, Lobry M, Colombeau L, Acherar S, Azaïs H, Mordon S, et al.
    Eur J Pharm Sci, 2016 Oct 10;93:419-30.
    PMID: 27575880 DOI: 10.1016/j.ejps.2016.08.045
    Folic acid is a small molecule, also known as vitamin B9. It is an essential compound involved in important biochemical processes. It is widely used as a vector for targeted treatment and diagnosis especially in cancer therapeutics. Nevertheless, not many authors address the problem of folic acid degradation. Several researchers reported their observations concerning its denaturation, but they generally only took into account one parameter (pH, temperature, light or O2etc.). In this review, we will focus on five main parameters (assessed individually or in conjunction with one or several others) that have to be taken into account to avoid the degradation of folic acid: light, temperature, concentration, oxygen and pH, which are the most cited in the literature. Scrupulous bibliographic research enabled us to determine two additional degradation factors that are the influence of singlet oxygen and electron beam on folic acid stability, which are not considered as among the prime factors. Although these two factors are not commonly present as compared to the others, singlet oxygen and electron beams intervene in new therapeutic technologies and must be taken in consideration for further applications such photodynamic or X-rays therapies.
    Matched MeSH terms: Folic Acid/radiation effects
  2. Khudzari J, Fukuda SY, Shiraiwa Y, Iwamoto K
    Environ Sci Pollut Res Int, 2023 Mar;30(12):34460-34467.
    PMID: 36509956 DOI: 10.1007/s11356-022-24573-6
    Cesium-137 (137Cs) is one of the radioactive substances that was released into the environment as a result of the Fukushima nuclear disaster. Radiocesium exposure is of great concern due to its potential environmental implications. However, research on 137Cs removal using algae is still limited. This is the first report to describe the kinetic properties of 137Cs uptake by Vacuoliviride crystalliferum in the presence and absence of potassium. In this work, we studied the kinetic properties of 137Cs uptake using a freshwater microalga, V. crystalliferum (NIES 2860). We also analyzed the effects of temperature, light, and potassium (K) on the 137Cs uptake. Results showed that V. crystalliferum can remove up to 90% of 157 nM 137Cs within an hour. At 20 °C, the removal increased by up to 96%, compared to less than 10% at 5 °C. However, the removal was inhibited by nearly 90% in the dark compared to the removal in the light, implying that V. crystalliferum cells require energy to accumulate 137Cs. In the inhibition assay, K concentrations ranged from 0 to 500 µM and the inhibitory constant (Ki) for K was determined to be 16.7 µM. While in the uptake assay without potassium (- K), the Michaelis constant (Km) for Cs was 45 nM and increased to 283 nM by the addition of 20 µM potassium (+ K), indicating that V. crystalliferum had a high affinity for 137Cs. In addition, the maximum uptake velocity (Vmax) also increased from 6.75 to 21.10 nmol (mg Chl h)-1, implying the existence of Cs active transport system. In conclusion, V. crystalliferum is capable of removing radioactive 137Cs from the environment and the removal was favorable at both normal temperature and in the light.
    Matched MeSH terms: Radiation Monitoring*
  3. Siraz MMM, Kamal MH, Khan ZH, Alam MS, Al Mahmud J, Rashid MB, et al.
    Environ Monit Assess, 2023 Aug 10;195(9):1028.
    PMID: 37558890 DOI: 10.1007/s10661-023-11636-5
    This study marks the first-ever assessment of radiological hazards linked to the sands and rocks of Patuartek Sea Beach, situated along one of the world's longest sea beaches in Cox' Bazar of Bangladesh. Through the utilization of an HPGe detector, a comprehensive analysis of the activity concentrations of 226Ra, 232Th, and 40 K was conducted, and their activity ranged from 7 to 23 Bq/kg, 9-58 Bq/kg, and 172-340 Bq/kg, respectively, in soils, and 19-24 Bq/kg, 27-39 Bq/kg, and 340-410 Bq/kg, respectively, in rocks. Some sand samples exhibited elevated levels of 232Th, while the rock samples displayed higher levels of 40 K compared to the global average. The radiological hazard parameters were assessed, and no values surpassed the recommended limits set by several international organizations. Hence, the sands and rocks of Patuartek sea beach pose no significant radiological risk to the residents or tourists. The findings of this study provide crucial insights for the development of a radiological baseline map in the country, which is important due to the commissioning of the country's first nuclear power plant Rooppur Nuclear Power Plant. The data may also stimulate interest in the rare-earth minerals present in the area, which is important for the electronics industry, thorium-based nuclear fuel cycles.
    Matched MeSH terms: Radiation Monitoring*
  4. Adhimoolam SK, Kumar S, Manojkumar T, Devanand BL, Elango N, Govindarajan N, et al.
    Radiat Prot Dosimetry, 2024 Nov 18;200(19):1926-1932.
    PMID: 39375206 DOI: 10.1093/rpd/ncae199
    The purpose of this study was to assess local diagnostic reference levels (LDRLs) for full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) mammography in India. Data from 1500 women were collected from five different mammography facilities in major cities in Tamil Nadu, India. The mean of mean glandular dose were used to arrive at an LDRL. The noted mean compressed breast thickness was 55.26 ± 3.4. The recorded mean MGDs for the five centres were 3.1 ± 0.1 and 3.8 ± 0.2 mGy for FFDM and DBT, respectively. The 75th percentile value for all five centers is 3.3 and 4.0 mGy for FFDM and DBT, respectively. The LDRLs found in the current study were also compared with those from earlier studies conducted in other nations, such as the United Kingdom, Malaysia, Morocco, and Ghana. The present study is the first of its kind to determine the LDRL for the FFDM and DBT scanners operating in the Tamil Nadu region, India, and is proposed as a starting point that will allow professionals to evaluate and optimize their practice. Furthermore, similar studies in other regions of India are necessary in order to establish National DRLs.
    Matched MeSH terms: Radiation Dosage*
  5. Romdhoni AC, Rajanagara AS, Albab CF, Waskito LA, Wibowo IN, Yunus MRM
    Asian Pac J Cancer Prev, 2024 Jul 01;25(7):2211-2218.
    PMID: 39068551 DOI: 10.31557/APJCP.2024.25.7.2211
    OBJECTIVE: One of the biggest therapy challenges for nasopharyngeal cancer (NPC) is still radioresistance.  The radioresistance in NPC is thought to be caused by cyclin D1 overexpression.  The purpose of this study was to determine how cyclin D1 contributes to radiation resistance in NPC.

    METHODS: Adhering to the PRISMA guidelines, we systematically reviewed studies on cyclin D1-associated radioresistance in NPC from 2012 until 2023.  From our search, 15 studies were included.

    RESULTS: Cyclin D1's role in radiotherapy resistance is elucidated through several mechanisms, notably SHP-1 and B-catenin. Overexpression of SHP-1 led to an increase in cyclin D1, a higher proportion of cells in the S-phase, and radioresistance.  Conversely, inhibiting β-catenin and cyclin D1 expression enhances radiation sensitivity.

    CONCLUSION: In conclusion, Cyclin D1 has a strong correlation with radiation resistance; downregulation of the protein increases radiosensitivity, while overexpression of the protein promotes radioresistance.

    Matched MeSH terms: Radiation Tolerance*
  6. Hashim N, Jamalludin Z, Ung NM, Ho GF, Malik RA, Phua VC
    Asian Pac J Cancer Prev, 2014;15(13):5259-64.
    PMID: 25040985
    BACKGROUND: CT based brachytherapy allows 3-dimensional (3D) assessment of organs at risk (OAR) doses with dose volume histograms (DVHs). The purpose of this study was to compare computed tomography (CT) based volumetric calculations and International Commission on Radiation Units and Measurements (ICRU) reference-point estimates of radiation doses to the bladder and rectum in patients with carcinoma of the cervix treated with high-dose-rate (HDR) intracavitary brachytherapy (ICBT).

    MATERIALS AND METHODS: Between March 2011 and May 2012, 20 patients were treated with 55 fractions of brachytherapy using tandem and ovoids and underwent post-implant CT scans. The external beam radiotherapy (EBRT) dose was 48.6 Gy in 27 fractions. HDR brachytherapy was delivered to a dose of 21 Gy in three fractions. The ICRU bladder and rectum point doses along with 4 additional rectal points were recorded. The maximum dose (DMax) to rectum was the highest recorded dose at one of these five points. Using the HDR plus 2.6 brachytherapy treatment planning system, the bladder and rectum were retrospectively contoured on the 55 CT datasets. The DVHs for rectum and bladder were calculated and the minimum doses to the highest irradiated 2cc area of rectum and bladder were recorded (D2cc) for all individual fractions. The mean D2cc of rectum was compared to the means of ICRU rectal point and rectal DMax using the Student's t-test. The mean D2cc of bladder was compared with the mean ICRU bladder point using the same statistical test .The total dose, combining EBRT and HDR brachytherapy, were biologically normalized to the conventional 2 Gy/fraction using the linear-quadratic model. (α/β value of 10 Gy for target, 3 Gy for organs at risk).

    RESULTS: The total prescribed dose was 77.5 Gy α/β10. The mean dose to the rectum was 4.58 ± 1.22 Gy for D 2cc, 3.76 ± 0.65 Gy at D ICRU and 4.75 ± 1.01 Gy at DMax. The mean rectal D 2cc dose differed significantly from the mean dose calculated at the ICRU reference point (p<0.005); the mean difference was 0.82 Gy (0.48 -1.19 Gy). The mean EQD2 was 68.52 ± 7.24 Gy α/β3 for D 2cc, 61.71 ± 2.77 Gy α/β3 at D ICRU and 69.24 ± 6.02 Gy α/β3 at DMax. The mean ratio of D 2cc rectum to D ICRU rectum was 1.25 and the mean ratio of D 2cc rectum to DMax rectum was 0.98 for all individual fractions. The mean dose to the bladder was 6.00 ± 1.90 Gy for D 2cc and 5.10 ± 2.03 Gy at D ICRU. However, the mean D 2cc dose did not differ significantly from the mean dose calculated at the ICRU reference point (p=0.307); the mean difference was 0.90 Gy (0.49-1.25 Gy). The mean EQD2 was 81.85 ± 13.03 Gy α/β3 for D 2cc and 74.11 ± 19.39 Gy α/β3 at D ICRU. The mean ratio of D 2cc bladder to D ICRU bladder was 1.24. In the majority of applications, the maximum dose point was not the ICRU point. On average, the rectum received 77% and bladder received 92% of the prescribed dose.

    CONCLUSIONS: OARs doses assessed by DVH criteria were higher than ICRU point doses. Our data suggest that the estimated dose to the ICRU bladder point may be a reasonable surrogate for the D 2cc and rectal DMax for D 2cc. However, the dose to the ICRU rectal point does not appear to be a reasonable surrogate for the D 2cc.

    Matched MeSH terms: Urinary Bladder/radiation effects*; Radiation Dosage; Rectum/radiation effects*
  7. Jacob S, Boveda S, Bar O, Brézin A, Maccia C, Laurier D, et al.
    Int J Cardiol, 2013 Sep 1;167(5):1843-7.
    PMID: 22608271 DOI: 10.1016/j.ijcard.2012.04.124
    Interventional cardiologists (ICs) are exposed to X-rays and may be at risk to develop cataract earlier than common senile cataract. Excess risk of posterior subcapsular cataract, known as radiation-induced, was previously observed in samples of ICs from Malaysia, and Latin America. The O'CLOC study (Occupational Cataracts and Lens Opacities in interventional Cardiology) was performed to quantify the risk at the scale of France.
    Matched MeSH terms: Radiation Injuries/diagnosis; Radiation Injuries/etiology; Radiation Injuries/epidemiology*
  8. Alzoubi AS, Kandaiya S, Shukri A, Elsherbieny E
    Australas Phys Eng Sci Med, 2010 Jun;33(2):137-44.
    PMID: 20309667 DOI: 10.1007/s13246-010-0011-y
    Second cancer induction in the contralateral breast (CB) is an issue of some concern in breast radiotherapy especially for women under the age of 45 years at the time of treatment. The CB dose from 2-field and 3-field techniques in post-mastectomy chest wall irradiations in an anthropomorphic phantom as well as in patients were measured using thermoluminescent dosimeters (TLDs) at the local radiotherapy center. Breast and chest wall radiotherapy treatments were planned conformally (3D-CRT) and delivered using 6-MV photons. The measured CB dose at the surface fell sharply with distance from the field edge. However, the average ratio of the measured to the calculated CB dose using the pencil beam algorithm at the surface was approximately 53%. The mean and median measured internal dose at the posterior border of CB in a phantom was 5.47+/-0.22 cGy and 5.44 cGy, respectively. The internal CB dose was relatively independent of depth. In the present study the internal CB dose is 2.1-4.1% of the prescribed dose which is comparable to the values reported by other authors.
    Matched MeSH terms: Neoplasms, Radiation-Induced/etiology; Thoracic Wall/radiation effects
  9. Baharudin A, Khairuddin A, Nizam A, Samsuddin AR
    J Laryngol Otol, 2009 Jan;123(1):108-13.
    PMID: 18452635 DOI: 10.1017/S0022215108002466
    Radiotherapy is an important treatment modality for head and neck tumours. One of its major drawbacks is post-treatment salivary gland hypofunction. This study was performed to objectively evaluate the salivary gland function in post-irradiated head and neck tumour patients.
    Matched MeSH terms: Dose-Response Relationship, Radiation; Salivary Glands/radiation effects*; Salivation/radiation effects*
  10. Wahib N, Zulkepely NN, Mat Nawi SN, Amin YM, Ling YS, Abdul Sani SF, et al.
    Appl Radiat Isot, 2015 Nov;105:158-162.
    PMID: 26313622 DOI: 10.1016/j.apradiso.2015.08.025
    Over the past decade and more, considerable interest has been shown in the thermoluminescence (TL) properties of silica-based single-mode optical fibres, in particular investigating potential ionising radiation dosimetry applications. Herein, study has been made of TL glow curve, dose response, reproducibility and fading of 6mol% Ge-doped silica, fabricated in-house and produced in the form of cylindrical fibres. Three different pairings of doped-core and silica cladding diameters were produced: (40, 241)µm, (80, 483)µm and (100, 604)µm. The TL results were compared against that of TLD-100, one of the most sensitive commercially available LiF-based TL media. For all three pairings of diameters, closely similar TL glow curve were obtained, formed of a single peaked structure with a maximum TL yield located between the temperatures 250 and 310°C. The TL yield of the fibres were linear over the range of doses investigated, from 1Gy up to 10Gy, their dose response exceeding that of TLD-100, the samples also being found to be reusable, without evidence of degradation.
    Matched MeSH terms: Radiation, Ionizing
  11. Bradley DA, Jafari SM, Siti Shafiqah AS, Tamcheck N, Shutt A, Siti Rozaila Z, et al.
    Appl Radiat Isot, 2016 Nov;117:128-134.
    PMID: 26778762 DOI: 10.1016/j.apradiso.2015.12.034
    Using irradiated doped-silica preforms from which fibres for thermoluminescence dosimetry applications can be fabricated we have carried out a range of luminescence studies, the TL yield of the fibre systems offering many advantages over conventional passive dosimetry types. In this paper we investigate such media, showing emission spectra for irradiated preforms and the TL response of glass beads following irradiation to an 241Am-Be neutron source located in a tank of water, the glass fibres and beads offering the advantage of being able to be placed directly into liquid. The outcomes from these and other lines of research are intended to inform development of doped silica radiation dosimeters of versatile utility, extending from environmental evaluations through to clinical and industrial applications.
    Matched MeSH terms: Radiation Dosimeters
  12. Biswal BM, Zakaria A, Ahmad NM
    Support Care Cancer, 2003 Apr;11(4):242-8.
    PMID: 12673463
    BACKGROUND: The aim of this study was to evaluate the effect of pure natural honey on radiation-induced mucositis.

    PATIENTS AND METHODS: Forty patients diagnosed with head and neck cancer requiring radiation to the oropharyngeal mucosal area were divided in to two groups to receive either radiation alone or radiation plus topical application of pure natural honey. Patients were treated using a 6-MV linear accelerator at a dose rate of 2 Gy per day five times a week up to a dose of 60-70 Gy. In the study arm, patients were advised to take 20 ml of pure honey 15 min before, 15 min after and 6 h post-radiation therapy. Patients were evaluated every week for the development of radiation mucositis using the Radiation Therapy Oncology Group (RTOG) grading system.

    MAIN RESULTS: There was significant reduction in the symptomatic grade 3/4 mucositis among honey-treated patients compared to controls; i.e. 20% versus 75% ( p 0.00058). The compliance of honey-treated group of patients was better than controls. Fifty-five percent of patients treated with topical honey showed no change or a positive gain in body weight compared to 25% in the control arm ( p 0.053), the majority of whom lost weight.

    CONCLUSIONS: Topical application of natural honey is a simple and cost-effective treatment in radiation mucositis, which warrants further multi-centre randomised trials to validate our finding.

    Matched MeSH terms: Radiation Injuries/therapy*; Radiation-Protective Agents/administration & dosage*
  13. Ng KH, Abdullah BJ, Sivalingam S
    Health Phys, 1999 Jul;77(1):33-6.
    PMID: 10376539
    The medical radiation usage for diagnostic radiology in Malaysia (a Level II country) for 1990-1994 is reported, enabling a comparison to be made for the first time with the United Nations Scientific Committee on the Effects of Atomic Radiation Report. In 1994, the number of physicians, radiologists, x-ray units, and x-ray examinations per 1,000 population was 0.45, 0.005, 0.065, and 183, respectively. (Level I countries had averages of 2.6, 0.072, 0.35, and 860, respectively). In 1994, a total of 3.6 million x-ray examinations were performed; the annual effective dose per capita to the population was 0.05 mSv, and the collective effective dose was 1,000 person-Sv. Chest examinations contributed 63% of the total. Almost all examinations experienced increasing frequency from 1990 to 1994 except for barium studies, cholecystography, and intravenous urography (-23%, -36%, -51%). These decreases are related to the increasing use of ultrasound and greater availability of fiberoptic endoscopy. Notable increases during the same period were observed in computed tomography (161%), cardiac procedures (190%), and mammography (240%). In order to progress from Level II to Level I status Malaysia needs to expand and upgrade radiological service in tandem with the health care development of the country.
    Matched MeSH terms: Radiation Dosage
  14. Wagner HN
    JAMA, 1988 Aug 5;260(5):697-8.
    PMID: 3392799
    Matched MeSH terms: Radiation Dosage
  15. Jérôme FK, Evariste WT, Bernard EZ, Crespo ML, Cicuttin A, Reaz MBI, et al.
    Sensors (Basel), 2021 Mar 04;21(5).
    PMID: 33806350 DOI: 10.3390/s21051760
    The front-end electronics (FEE) of the Compact Muon Solenoid (CMS) is needed very low power consumption and higher readout bandwidth to match the low power requirement of its Short Strip application-specific integrated circuits (ASIC) (SSA) and to handle a large number of pileup events in the High-Luminosity Large Hadron Collider (LHC). A low-noise, wide bandwidth, and ultra-low power FEE for the pixel-strip sensor of the CMS has been designed and simulated in a 0.35 µm Complementary Metal Oxide Semiconductor (CMOS) process. The design comprises a Charge Sensitive Amplifier (CSA) and a fast Capacitor-Resistor-Resistor-Capacitor (CR-RC) pulse shaper (PS). A compact structure of the CSA circuit has been analyzed and designed for high throughput purposes. Analytical calculations were performed to achieve at least 998 MHz gain bandwidth, and then overcome pileup issue in the High-Luminosity LHC. The spice simulations prove that the circuit can achieve 88 dB dc-gain while exhibiting up to 1 GHz gain-bandwidth product (GBP). The stability of the design was guaranteed with an 82-degree phase margin while 214 ns optimal shaping time was extracted for low-power purposes. The robustness of the design against radiations was performed and the amplitude resolution of the proposed front-end was controlled at 1.87% FWHM (full width half maximum). The circuit has been designed to handle up to 280 fC input charge pulses with 2 pF maximum sensor capacitance. In good agreement with the analytical calculations, simulations outcomes were validated by post-layout simulations results, which provided a baseline gain of 546.56 mV/MeV and 920.66 mV/MeV, respectively, for the CSA and the shaping module while the ENC (Equivalent Noise Charge) of the device was controlled at 37.6 e- at 0 pF with a noise slope of 16.32 e-/pF. Moreover, the proposed circuit dissipates very low power which is only 8.72 µW from a 3.3 V supply and the compact layout occupied just 0.0205 mm2 die area.
    Matched MeSH terms: Radiation
  16. Jusoh H, Sabariah Binti Abd Manan T, Beddu S, Osman SBS, Jusoh MNH, Mohtar WHMW, et al.
    Data Brief, 2020 Aug;31:105868.
    PMID: 32637485 DOI: 10.1016/j.dib.2020.105868
    Soil requires load bearing impact assessment for stability. Therefore, this study aims to utilize the multi-channel analysis surface wave (MASW) for soil subsurface investigation and profiling around Peninsular Malaysia. The standard penetration test (SPT) was conducted for comparison between factual N-value and computed N-value from shear wave velocity (Vs ) obtained from MASW using the Imai and Tonouchi equation. The correlation coefficient (R) and coefficient of determination, (R2 ), showed strong relationship between factual N-value and computed N-value. The model of Vs and factual N-value data distribution is non-normal but the analyzed relationship shows a significant level of p-value < 0.05. The R2 for each location of Vs -N-value relationship are ranging from 0.5 to 0.9.
    Matched MeSH terms: Radiation
  17. Laila Kalidah Junet, Zafri Azran Abdul Majid, Muhammad Syahmi Che Othaman
    MyJurnal
    Aluminum (Al) is a standard material that has been used as a filter for ionising radiation however for polyvinyl chloride (PVC) there is no solid evidence to support but has been recommended. PVC has been selected as a potential filter material due to it is a long lasting constructing material and very durable, which can be used in a variety of application. The purpose of this study was to observe the effect of PVC on entrance surface dose (ESD) values as compare to the standard X-ray filter of Al. The effect of varying thickness of the materials and difference exposure settings were observed and compared to each other. From this study, the percentage difference for both PVC and Al thickness is less than ± 25.00 % shows that PVC has a potential to be used as one of the filter materials due to its ability to reduce the ESD value
    Matched MeSH terms: Radiation, Ionizing
  18. Supardi, N. F., Mohd Taib, N. H., Abu Amat, N. H., Yusoff, M. N. S.
    MyJurnal
    Wi-Fi is a wireless communication technology that uses specific electromagnetic frequencies. The increasing use of Wi-Fi has raised public concerns about the impact of electromagnetic radiation on the environment and human health. Since the exposure level of the electromagnetic field (EMF) radiation differs between different locations, it is important to measure the strength of the EMF at various locations under observation. This study aimed to obtain specific values related to the radiofrequency and microwave EMF which is described by four specific parameters, that are 1) the frequency of the wave, 2) the electric field strength E, 3) the magnetic field strength H, and 4) the power density S. This study was carried out at the first floor area of Hamdan Tahir Library, Universiti Sains Malaysia Health Campus. Mapping of Wi-Fi signal and measurement of Wi-Fi radiation level was performed at four specific locations, that are Laptop zone 1, Laptop zone 2, Computer lab, and Cozy corner. The average radiation level was compared with the ICNIRP standard limit for public user. It was observed that the Wi-Fi signal was highest in Laptop zone 2 followed by Laptop zone 1 which displayed a moderate signal strength. Whereas moderate but lower signal level was detected in Computer lab zone and Cozy corner. The electric and magnetic fields as well as power density were found highest in Laptop zone 1, followed by Laptop zone 2, Cozy corner, and Computer lab. Comparison with standard ICNIRP limit showed that the radiation level is still far below the ICNIRP limit, which is only 2% of exposure level. To conclude, Laptop zone 2 exhibited the strongest Wi-Fi signal whereas Laptop zone 1 displayed the highest radiation level. However, the strength of the electric and magnetic fields as well as power density is still far below the ICNIRP limit.
    Matched MeSH terms: Electromagnetic Radiation
  19. Gill MK, Vijayananthan A, Kumar G, Jayarani K, Ng KH, Sun Z
    Quant Imaging Med Surg, 2015 Aug;5(4):524-33.
    PMID: 26435916 DOI: 10.3978/j.issn.2223-4292.2015.04.04
    To determine the effective radiation dose and image quality resulting from 100 versus 120 kilovoltage (kV) protocols among patients referred for computed tomography pulmonary angiography (CTPA).
    Matched MeSH terms: Radiation Dosage
  20. Ibrahim I, Lim HN, Huang NM, Jiang ZT, Altarawneh M
    J Hazard Mater, 2020 06 05;391:122248.
    PMID: 32062348 DOI: 10.1016/j.jhazmat.2020.122248
    Nowadays, increasing the risk for copper leaching into the drinking water in homes, hotels and schools has become unresolved issues all around the countries such as Canada, the United States, and Malaysia. The leaching of copper in tap water is due to a combination of acidic water, damaged pipes, and corroded plumbing fixtures. To remedy this global problem, a triple interconnected structure of CdS/Au/GQDs was designed as a photo-to-electron conversion medium for a real time and selective visible-light-prompt photoelectrochemical (PEC) sensor for Cu2+ ions in real water samples. The synergistic interaction of the CdS/Au/GQDs enabled the smooth transportation of charge carriers to the charge collector and provided a channel to inhibit the charge recombination reaction. Thus, a detection limit of 2.27 nM was obtained, which is 10,000 fold lower than that of WHO's Guidelines for Drinking-water Quality (∼30 μM). The photocurrent reduction was negligible after 30 days of storage under ambient conditions, suggesting the high stability of photoelectrode. Moreover, the real-time monitoring of Cu2+ ions in real samples was performed with satisfactory results, confirming the capability of the investigated photoelectrode as the most practical detector for trace amounts of Cu2+ ions.
    Matched MeSH terms: Sulfides/radiation effects*; Cadmium Compounds/radiation effects*; Nanotubes/radiation effects*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links