Displaying publications 21 - 34 of 34 in total

Abstract:
Sort:
  1. Farook TH, Rashid F, Jamayet NB, Abdullah JY, Dudley J, Khursheed Alam M
    J Prosthet Dent, 2022 Oct;128(4):830-836.
    PMID: 33642077 DOI: 10.1016/j.prosdent.2020.12.041
    STATEMENT OF PROBLEM: The anatomic complexity of the ear challenges conventional maxillofacial prosthetic rehabilitation. The introduction of specialized scanning hardware integrated into computer-aided design and computer-aided manufacturing (CAD-CAM) workflows has mitigated these challenges. Currently, the scanning hardware required for digital data acquisition is expensive and not readily available for prosthodontists in developing regions.

    PURPOSE: The purpose of this virtual analysis study was to compare the accuracy and precision of 3-dimensional (3D) ear models generated by scanning gypsum casts with a smartphone camera and a desktop laser scanner.

    MATERIAL AND METHODS: Six ear casts were fabricated from green dental gypsum and scanned with a laser scanner. The resultant 3D models were exported as standard tessellation language (STL) files. A stereophotogrammetry system was fabricated by using a motorized turntable and an automated microcontroller photograph capturing interface. A total of 48 images were captured from 2 angles on the arc (20 degrees and 40 degrees from the base of the turntable) with an image overlap of 15 degrees, controlled by a stepper motor. Ear 1 was placed on the turntable and captured 5 times with smartphone 1 and tested for precision. Then, ears 1 to 6 were scanned once with a laser scanner and with smartphones 1 and 2. The images were converted into 3D casts and compared for accuracy against their laser scanned counterparts for surface area, volume, interpoint mismatches, and spatial overlap. Acceptability thresholds were set at <0.5 mm for interpoint mismatches and >0.70 for spatial overlap.

    RESULTS: The test for smartphone precision in comparison with that of the laser scanner showed a difference in surface area of 774.22 ±295.27 mm2 (6.9% less area) and in volume of 4228.60 ±2276.89 mm3 (13.4% more volume). Both acceptability thresholds were also met. The test for accuracy among smartphones 1, 2, and the laser scanner showed no statistically significant differences (P>.05) in all 4 parameters among the groups while also meeting both acceptability thresholds.

    CONCLUSIONS: Smartphone cameras used to capture 48 overlapping gypsum cast ear images in a controlled environment generated 3D models parametrically similar to those produced by standard laser scanners.

  2. Mahat NS, Shetty NY, Kohli S, Jamayet NB, Patil P
    Evid Based Dent, 2023 Sep;24(3):142.
    PMID: 37369705 DOI: 10.1038/s41432-023-00904-5
    OBJECTIVE: To analyze the clinical outcomes of implant-supported prostheses and tooth-supported fixed prostheses, fabricated from digital and conventional impression.

    MATERIALS AND METHODS: The literature search was carried out on two electronic databases (PubMed and Cochrane Library). Randomized controlled trials (RCT) published from January 2011 to September 2022 were included. The bias risk was evaluated using Cochrane Risk of Bias Tool 2.0. Further screening was done for meta-analysis according to modified Newcastle-Ottawa scoring criteria. Forest plot was generated using a statistical method of inverse variance of random effect with 95% confidence interval.

    RESULTS: A total of 8 randomized controlled trials were included for systematic review out of which four studies were based on tooth-supported fixed prosthesis and remaining four were based on implant-supported prosthesis. Further screening was conducted and three studies were eligible for meta-analysis. Tooth-supported fixed prosthesis fabricated from digital impression showed no significant difference in the marginal fit in any region measured, except for occlusal region where conventional impression showed more favorable marginal fit. Implant-supported prosthesis fabricated from digital impression showed survival rates ranging from 97.3 to 100% and there was no statistically significant difference in marginal bone loss (p = 0.14).

    CONCLUSION: Implant-supported prostheses fabricated from digital and conventional impressions show no significant differences in their clinical outcomes. Tooth-supported fixed prostheses fabricated from digital impression have shown favorable findings in terms of marginal fit. Despite that, there is still lack of clinical trials with larger sample size and longer follow-up periods. Future studies that fulfill these two criteria are deemed necessary.

  3. Barman A, Rashid F, Farook TH, Jamayet NB, Dudley J, Yhaya MFB, et al.
    Polymers (Basel), 2020 Jul 12;12(7).
    PMID: 32664615 DOI: 10.3390/polym12071536
    Although numerous studies have demonstrated the benefits of incorporating filler particles into maxillofacial silicone elastomer (MFPSE), a review of the types, concentrations and effectiveness of the particles themselves was lacking. The purpose of this systematic review and meta-analysis was to review the effect of different types of filler particles on the mechanical properties of MFPSE. The properties in question were (1) tensile strength, (2) tear strength, (3) hardness, and (4) elongation at break. The findings of this study can assist operators, technicians and clinicians in making relevant decisions regarding which type of fillers to incorporate based on their needs. The systematic review was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A total of 26 original articles from 1970 to 2019 were selected from the databases, based on predefined eligibility criteria by two reviewers. The meta-analyses of nine papers were carried out by extracting data from the systematic review based on scoring criteria and processed using Cochrane Review Manager 5.3. Overall, there were significant differences favoring filler particles when incorporated into MFPSE. Nano fillers (69.23% of all studies) demonstrated superior comparative outcomes for tensile strength (P < 0.0001), tear strength (P < 0.00001), hardness (P < 0.00001) and elongation at break (P < 0.00001) when compared to micro fillers (30.76% of all studies). Micro fillers demonstrated inconsistent outcomes in mechanical properties, and meta-analysis of elongation at break argued against (P < 0.01) their use. Current findings suggest that 1.5% ZrSiO4, 3% SiO2, 1.5% Y2O3, 2-6% TiO2, 2-2.5% ZnO, 2-2.5% CeO2, 0.5% TiSiO4 and 1% Ag-Zn Zeolite can be used to reinforce MFPSE, and help the materials better withstand mechanical degradation.
  4. Jamayet NB, Kirangi JK, Husein A, Alam MK
    Eur J Dent, 2017 4 25;11(1):130-134.
    PMID: 28435380 DOI: 10.4103/1305-7456.202636
    Enucleation and evisceration are the most common surgical procedures that are performed to manage tumor, trauma, and infection. Given the consequences of surgical intervention, the conditions of the remaining eye socket may affect future prosthetic rehabilitation. A custom-made ocular prosthesis can be used to help restore the esthetics and functional defects and to improve the quality of life of patients with such conditions. An assessment must be performed on the prosthetic outcome before rehabilitation. The etiology of defect, type of surgery, condition of the remaining socket, and patient's age should all be considered. This report discusses three different etiological eye defects that have undergone enucleation and evisceration and describes the factors that have a significant role in the esthetic and functional outcome of the prosthesis. This report should serve as a helpful aid for maxillofacial prosthodontists to understand the primary objective of rehabilitating each eye defect and to meet patient expectations.
  5. Farook TH, Abdullah JY, Jamayet NB, Alam MK
    J Prosthet Dent, 2021 Feb 15.
    PMID: 33602541 DOI: 10.1016/j.prosdent.2020.07.039
    STATEMENT OF PROBLEM: Computer-aided design (CAD) of maxillofacial prostheses is a hardware-intensive process. The greater the mesh detail is, the more processing power is required from the computer. A reduction in mesh quality has been shown to reduce workload on computers, yet no reference value of reduction is present for intraoral prostheses that can be applied during the design.

    PURPOSE: The purpose of this simulation study was to establish a reference percentage value that can be used to effectively reduce the size and polygons of the 3D mesh without drastically affecting the dimensions of the prosthesis itself.

    MATERIAL AND METHODS: Fifteen different maxillary palatal defects were simulated on a dental cast and scanned to create 3D casts. Digital bulbs were fabricated from the casts. Conventional bulbs for the defects were fabricated, scanned, and compared with the digital bulb to serve as a control. The polygon parameters of digital bulbs were then reduced by different percentages (75%, 50%, 25%, 10%, 5%, and 1% of the original mesh) which created a total of 105 meshes across 7 mesh groups. The reduced mesh files were compared individually with the original design in an open-source point cloud comparison software program. The parameters of comparison used in this study were Hausdorff distance (HD), Dice similarity coefficient (DSC), and volume.

    RESULTS: The reduction in file size was directly proportional to the amount of mesh reduction. There were minute yet insignificant differences in volume (P>.05) across all mesh groups, with significant differences (P

  6. Xin KY, Eusufzai SZ, Jamayet NB, Alam MK
    Work, 2020;67(1):165-171.
    PMID: 32955481 DOI: 10.3233/WOR-203262
    BACKGROUND: Accidental occupational injuries increase the risk of communicable diseases like hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV) among dental personnel. Such occupational injuries affect healthcare quality by enhancing dissatisfaction and lack of motivation to work among dental personnel.

    OBJECTIVE: The present study aims to assess knowledge and awareness regarding needle stick and sharp injury among dental personnel and compared the knowledge and awareness level about needle stick injuries between dental professionals and dental supporting staff working at the School of Dental Sciences, Universiti Sains Malaysia.

    METHODS: This cross-sectional study was conducted from March 2016 to March 2017. The total sample included 112 registered dental personnel including dental professionals (lecturers, dental officers, and postgraduate students) and dental supportive staff (including staff nurses and dental surgery assistant) who were selected from the School of Dental Sciences, Universiti Sains Malaysia at Kelantan District of Malaysia. Data were collected by a structured questionnaire.

    RESULTS: In our study 60.7% respondents answered correctly for all the statements regarding knowledge and 51.8% of the respondents answered correctly for the statements regarding awareness on needle stick and sharp injury. No significant difference of knowledge level has been observed between the dental professionals and dental supportive staff (p 

  7. Farook TH, Barman A, Abdullah JY, Jamayet NB
    J Prosthodont, 2021 Jun;30(5):420-429.
    PMID: 33200429 DOI: 10.1111/jopr.13286
    PURPOSE: Mesh optimization reduces the texture quality of 3D models in order to reduce storage file size and computational load on a personal computer. This study aims to explore mesh optimization using open source (free) software in the context of prosthodontic application.

    MATERIALS AND METHODS: An auricular prosthesis, a complete denture, and anterior and posterior crowns were constructed using conventional methods and laser scanned to create computerized 3D meshes. The meshes were optimized independently by four computer-aided design software (Meshmixer, Meshlab, Blender, and SculptGL) to 100%, 90%, 75%, 50%, and 25% levels of original file size. Upon optimization, the following parameters were virtually evaluated and compared; mesh vertices, file size, mesh surface area (SA), mesh volume (V), interpoint discrepancies (geometric similarity based on virtual point overlapping), and spatial similarity (volumetric similarity based on shape overlapping). The influence of software and optimization on surface area and volume of each prosthesis was evaluated independently using multiple linear regression.

    RESULTS: There were clear observable differences in vertices, file size, surface area, and volume. The choice of software significantly influenced the overall virtual parameters of auricular prosthesis [SA: F(4,15) = 12.93, R2 = 0.67, p < 0.001. V: F(4,15) = 9.33, R2 = 0.64, p < 0.001] and complete denture [SA: F(4,15) = 10.81, R2 = 0.67, p < 0.001. V: F(4,15) = 3.50, R2 = 0.34, p = 0.030] across optimization levels. Interpoint discrepancies were however limited to <0.1mm and volumetric similarity was >97%.

    CONCLUSION: Open-source mesh optimization of smaller dental prostheses in this study produced minimal loss of geometric and volumetric details. SculptGL models were most influenced by the amount of optimization performed.

  8. Farook TH, Jamayet NB, Abdullah JY, Alam MK
    Pain Res Manag, 2021;2021:6659133.
    PMID: 33986900 DOI: 10.1155/2021/6659133
    Purpose: The study explored the clinical influence, effectiveness, limitations, and human comparison outcomes of machine learning in diagnosing (1) dental diseases, (2) periodontal diseases, (3) trauma and neuralgias, (4) cysts and tumors, (5) glandular disorders, and (6) bone and temporomandibular joint as possible causes of dental and orofacial pain.

    Method: Scopus, PubMed, and Web of Science (all databases) were searched by 2 reviewers until 29th October 2020. Articles were screened and narratively synthesized according to PRISMA-DTA guidelines based on predefined eligibility criteria. Articles that made direct reference test comparisons to human clinicians were evaluated using the MI-CLAIM checklist. The risk of bias was assessed by JBI-DTA critical appraisal, and certainty of the evidence was evaluated using the GRADE approach. Information regarding the quantification method of dental pain and disease, the conditional characteristics of both training and test data cohort in the machine learning, diagnostic outcomes, and diagnostic test comparisons with clinicians, where applicable, were extracted.

    Results: 34 eligible articles were found for data synthesis, of which 8 articles made direct reference comparisons to human clinicians. 7 papers scored over 13 (out of the evaluated 15 points) in the MI-CLAIM approach with all papers scoring 5+ (out of 7) in JBI-DTA appraisals. GRADE approach revealed serious risks of bias and inconsistencies with most studies containing more positive cases than their true prevalence in order to facilitate machine learning. Patient-perceived symptoms and clinical history were generally found to be less reliable than radiographs or histology for training accurate machine learning models. A low agreement level between clinicians training the models was suggested to have a negative impact on the prediction accuracy. Reference comparisons found nonspecialized clinicians with less than 3 years of experience to be disadvantaged against trained models.

    Conclusion: Machine learning in dental and orofacial healthcare has shown respectable results in diagnosing diseases with symptomatic pain and with improved future iterations and can be used as a diagnostic aid in the clinics. The current review did not internally analyze the machine learning models and their respective algorithms, nor consider the confounding variables and factors responsible for shaping the orofacial disorders responsible for eliciting pain.

  9. Farook TH, Radford J, Alam MK, Jamayet NB
    Br Dent J, 2020 Oct 20.
    PMID: 33082524 DOI: 10.1038/s41415-020-2026-4
    Objective Following a survey of the literature, a systematic review was carried out with the aim of answering the following questions: 1) What is 'acceptable plagiarism'?; 2) Who carries out plagiarism?; 3) What factors could encourage plagiarism?; 4) How can plagiarism be managed?Data source and selection Following PRISMA guidelines, data were gathered by searching Scopus, PubMed and Web of Science. After removal of duplicates, 345 titles were identified. Then, having satisfied a priori eligibility criteria, 29 papers were interrogated. The quality of relevant papers (n = 23) was assessed using the Joanna Briggs Critical Appraisal Tool.Data extraction There was no clear threshold as to what is 'acceptable plagiarism'. Despite this lack of clarity, it is argued consistently that males, and those who wrote in a language that is not their mother tongue, were more likely to plagiarise.Conclusion Plagiarism is all but inescapable due to various reasons: 1) there is no agreed threshold as to what is 'acceptable plagiarism'; 2) the internet; 3) institutional; and 4) societal expectations. Plagiarism could be mitigated in the student domain by grammar support and, for example, non-written submissions such as presenting work by video. Academic fraud is fundamentally undermined by valuing original and creative scholarship and sound ethical principles.
  10. Dudley J, Pellew J, Jamayet NB
    Clin Case Rep, 2023 Jun;11(6):e7287.
    PMID: 37273667 DOI: 10.1002/ccr3.7287
    The conservative prosthodontic construction of an ocular prosthesis utilizing our novel threaded iris fabrication technique required high time and prosthodontic resource inputs and produced a lifelike aesthetic result.

    ABSTRACT: Patients with ocular defects frequently present with significant local anatomical deficiencies and complex histories and require extensive time and resource inputs to treat. This case report describes the conservative management of an ocular defect completed in a postgraduate prosthodontics clinical residency program utilizing a novel threaded iris fabrication technique.

Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links