MATERIALS AND METHODS: Pure tone audiometry test was conducted on 263 residents of a rural village who were not exposed to noise. The pack-years of smoking were computed from the subjects' smoking history. The association between pack-years and hearing impairment was assessed. The combined effect of smoking and age on hearing impairment was determined based on prevalence rate ratio.
RESULTS: There was a statistically significant trend in the number of pack-years of smoking and age as risk factors for hearing impairment. The prevalence rates of hearing impairment for nonsmokers aged 40 years and younger, smokers aged 40 years and younger, nonsmokers older than 40 years of age, and smokers older than 40 years of age were 6.9%, 11.9%, 29.7%, and 51.3%, respectively. The prevalence rate ratio for nonsmokers aged 40 years and younger, smokers aged 40 years and younger, nonsmokers older than 40 years of age, and smokers older than 40 years of age (nonsmokers aged 40 years and younger as a reference group) was 1, 1.7, 4.3, and 7.5, respectively. The prevalence rate ratios showed a multiplicative effect of smoking and age on hearing impairment.
CONCLUSION: Age and smoking are risk factors for hearing impairment. It is clear that smoking and age have multiplicative adverse effects on hearing impairment.
OBJECTIVE: To examine the relative contributions of auditory functioning and cognition status to speech recognition in quiet and in noise.
METHODS: We measured speech recognition in quiet and in composite noise using the Malay Hearing in noise test on 72 native Malay speakers (60-82 years) older adults with normal to mild hearing loss. Auditory function included pure tone audiogram, gaps-in-noise, and dichotic digit tests. Cognitive function was assessed using the Malay Montreal cognitive assessment.
RESULTS: Linear regression analyses using backward elimination technique revealed that had the better ear four frequency average (0.5-4kHz) (4FA), high frequency average and Malay Montreal cognitive assessment attributed to speech perception in quiet (total r2=0.499). On the other hand, high frequency average, Malay Montreal cognitive assessment and dichotic digit tests contributed significantly to speech recognition in noise (total r2=0.307). Whereas the better ear high frequency average primarily measured the speech recognition in quiet, the speech recognition in noise was mainly measured by cognitive function.
CONCLUSIONS: These findings highlight the fact that besides hearing sensitivity, cognition plays an important role in speech recognition ability among older adults, especially in noisy environments. Therefore, in addition to hearing aids, rehabilitation, which trains cognition, may have a role in improving speech recognition in noise ability of older adults.
METHOD: A cross-sectional study was conducted among 205 normal hearing adult participants with an age range between 25 and 54 years old. Hearing analysis with extended high-frequency pure-tone audiometry (PTA) and high-frequency DPOAE was carried out for all eligible participants. High-frequency presbycusis was considered to be present when the impairment of more than 25 dB occurs at higher than 8 kHz frequencies on both ears.
RESULTS: Prevalence of high-frequency presbycusis using extended PTA was 31.7 (95% CI: 25.3, 38.1) and using high-frequency DPOAE was 57.4 (95% CI: 50.7, 64.4). The sensitivity and specificity of high-frequency DPOAE in detecting high-frequency presbycusis were 72.3 and 49.3% respectively with positive predictive value of 39.8% and negative predictive value of 79.3%. The association between age and high-frequency presbycusis was significant based on high-frequency DPOAE (p = 0.029).
CONCLUSIONS: The prevalence of high-frequency hearing loss is higher with increasing in age. High-frequency DPOAE may be used as a screening tool followed by confirmation using extended PTA. The early detection of presbycusis is important so that measures can be taken to prevent more severe problems developing.
METHODS: Secondary analysis was carried out on data collected by the Grand Challenge Project among older adults aged ≥65 years from Selangor. Data on sociodemographic information, medical history, cognitive function and functional performance were obtained through face-to-face interviews using standardized questionnaires. Visual acuity was measured using the Early Treatment Diabetic Retinopathy Study (ETDRS) chart while hearing was assessed using pure-tone audiometry. Descriptive analysis was used to measure the prevalence of the impairments, and logistic regression analysis was used to identify the risk factors.
RESULTS: The prevalence of dual sensory impairment and hearing impairment were at 10.5% and 76.2% respectively. Multivariate logistic regression analysis revealed that participants with lower cognitive scores were associated with dual sensory impairment (odds ratio, 0.90; 95% confidence interval, 0.83-0.98), while smoking was found associated with hearing impairment (odds ratio, 6.58; 95% confidence interval, 1.51-28.65).
CONCLUSION: Dual sensory impairment is common among older adults in Selangor. The association between dual sensory impairment and cognitive function suggests the need to have visual and hearing screening on older adults for early detection particularly those at risk of cognitive impairment. The prevalence of hearing impairment was reported high among older adults and smokers appeared to be at higher risk of the impairment. Geriatr Gerontol Int 2020; 20: 911-916.
Case Report: In this paper, an unusual case of bilateral SSNHL secondary to bilateral CVT with rapid and complete recovery is reported. The patient presented with sudden bilateral hearing loss associated with some neurological symptoms. Initial computed tomography (CT) venography revealed a CVT of bilateral transverse sinuses. The patient was started on an anticoagulant and imaging was repeated after five days, revealing the absence of the thrombosis. Serial pure tone audiometry (PTA) showed complete recovery of bilateral hearing within 10 days.
Conclusion: Early detection and intervention may fasten hearing recovery and improve the quality of life. The immediate restoration of venous blood flow and intracranial pressure may lead to the complete recovery of bilateral hearing loss.
DESIGN: In this repeated-measures study, 20 normally hearing adults aged between 18 and 30 years were recruited. Tone bursts (500, 1000, 2000, and 4000 Hz) were used to record PAMR thresholds at 3 different stimulus repetition rates (6.1/s, 11.1/s, and 17.1/s).
RESULTS: Statistically higher PAMR thresholds were found for the faster stimulus rate (17.1/s) compared with the slower stimulus rate (6.1/s) (p < 0.05). For all stimulus rates and frequencies, significant correlations were found between PAMR and pure-tone audiometry thresholds (r = 0.62 to 0.82).
CONCLUSIONS: Even though the stimulus rate effect was significant at most of the tested frequencies, the differences in PAMR thresholds between the rates were small (<5 dB). Nevertheless, based on the correlation results, we suggest the use of 11.1/s stimulus rate when recording PAMR thresholds.
MATERIALS AND METHODS: One hundred and sixty patients, aged 12-80 years with unilateral hearing loss were studied using a VAS (1-10) and pure tone audiometry (PTA) of responses to 500, 1,000 and 2,000 Hz to determine degree and type of hearing loss. The results of both were compared to determine if VAS can be used in measuring hearing loss.
RESULTS: Patients with mild, moderate hearing loss correlate well with corresponding VAS but other degrees of hearing loss (severe and profound) have poor correlation. The best correlation between PTA and VAS were found in conductive type of hearing loss.
CONCLUSION: This study suggest that there may be a role for VAS in mild and moderate hearing loss. This may be more applicable in rural setting as a screening procedure when audiometry is not available and can enhance clinical hearing assessment especially in mild-to-moderate conductive hearing loss.
DESIGN AND STUDY SAMPLE: Study 1 compared the FS measure obtained with MOL and 2IFC procedure at two centre frequencies (CFs) (1 and 4 kHz) in 21 normal-hearing listeners. Study 2 determined the FS measure using MOL at five CFs (0.5-8 kHz) in 32 normal-hearing and nine sensorineural hearing loss listeners and compared them with their thresholds in quiet.
RESULTS: FS measurements with MOL and 2IFC methods were highly correlated and had statistically comparable intra-subject test-retest reliability. FS measures determined with MOL were reduced in the hearing-impaired compared to normal-hearing listeners at the CF corresponding to their hearing loss. Linear regression analysis showed significant relationship between FS deterioration and quiet threshold loss (p
OBJECTIVE: This study aims to investigate the feasibility of EEG measurements as an objective indicator for the identification of tinnitus-associated neural activities.
METHODS: To reduce heterogeneity, participants served as their own control using residual inhibition (RI) to modulate the tinnitus perception in a within-subject EEG study design with a tinnitus group. In addition, comparison with a nontinnitus control group allowed for a between-subjects comparison. We will apply RI stimulation to generate tinnitus and nontinnitus conditions in the same subject. Furthermore, high-frequency audiometry (up to 13 kHz) and tinnitometry will be performed.
RESULTS: This work was funded by the Infrastructure Grant of the University of Bern, Bern, Switzerland and Bernafon AG, Bern, Switzerland. Enrollment for the study described in this protocol commenced in February 2018. Data analysis is currently under way and the first results are expected to be submitted for publication in 2019.
CONCLUSIONS: This study design helps in comparing the neural activity between conditions in the same individual, thereby addressing a notable limitation of previous EEG tinnitus studies. In addition, the high-frequency assessment will help to analyze and classify tinnitus symptoms beyond the conventional clinical standard.
INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR1-10.2196/12270.
METHODS: A total of 301 older adults (⩾60 years of age) participating in a study on aging had their hearing tested using pure-tone audiometry. Self-perceived hearing loss was assessed using a single question. Sociodemographic profile, otologic history, and general cognitive status were also obtained.
RESULTS: A single question had low sensitivity in detecting actual hearing loss: 31.3% for 4-frequency average > 25 dBHL and 48.8% for 4-frequency average > 40 dBHL. Besides hearing level, history of otorrhea and tinnitus were factors that were associated with self-perceived hearing loss among older adults with at least mild hearing loss. Hearing-help-seeking behavior was not associated with any of the tested variables. The hearing aid adoption rate was 2.7% and 7.3% among participants with 4-frequency averages > 25 dBHL and > 40 dBHL, respectively.
CONCLUSION: The underestimation of hearing loss in the majority of older adults in this study poses a potential barrier to hearing loss intervention.
METHODS: This study involved 307 adults aged 60 years and older. Participants had their hearing and cognition measured using pure tone audiometry and Mini Mental State Examination (MMSE), respectively.
RESULTS: Pure tone average (low) accounted for significant but minimal amount of variance in measure of MMSE. Multiple regression analyses were also performed on normal and impaired hearing cohorts and cohorts with younger (60-69 years) and older (≥70 years) groups. The results revealed a significant relationship between PTA (low) and MMSE only in the younger age group. In contrast, no significant relationship was found between PTA (high) and cognition in any of the cohorts.
CONCLUSION: Pure tone average (low) is significantly but minimally related to measure of general cognitive status. Similar relationship is not observed between high-frequency hearing and cognition. Further research using a more comprehensive cognitive test battery is needed to confirm the lack of association between high-frequency hearing and cognition.