Displaying publications 21 - 40 of 72 in total

Abstract:
Sort:
  1. Chum JD, Lim DJZ, Sheriff SO, Pulikkotil SJ, Suresh A, Davamani F
    Restor Dent Endod, 2019 Feb;44(1):e8.
    PMID: 30834230 DOI: 10.5395/rde.2019.44.e8
    Objectives: Irrigants are imperative in endodontic therapy for the elimination of pathogens from the infected root canal. The present study compared the antimicrobial efficacy of octenidine dihydrochloride (OCT) with chlorhexidine (CHX) and sodium hypochlorite (NaOCl) against Staphylococcus epidermidis (S. epidermidis) for root canal disinfection.

    Materials and Methods: The minimum inhibitory concentration (MIC) was obtained using serial dilution method. The agar diffusion method was then used to determine the zones of inhibition for each irrigant. Lastly, forty 6-mm dentin blocks were prepared from human mandibular premolars and inoculated with S. epidermidis. Samples were randomly divided into 4 groups of 10 blocks and irrigated for 3 minutes with saline (control), 2% CHX, 3% NaOCl, or 0.1% OCT. Dentin samples were then collected immediately for microbial analysis, including an analysis of colony-forming units (CFUs).

    Results: The MICs of each tested irrigant were 0.05% for CHX, 0.25% for NaOCl, and 0.0125% for OCT. All tested irrigants showed concentration-dependent increase in zones of inhibition, and 3% NaOCl showed the largest zone of inhibition amongst all tested irrigants (p < 0.05). There were no significant differences among the CFU measurements of 2% CHX, 3% NaOCl, and 0.1% OCT showing complete elimination of S. epidermidis in all samples.

    Conclusions: This study showed that OCT was comparable to or even more effective than CHX and NaOCl, demonstrating antimicrobial activity at low concentrations against S. epidermidis.

    Matched MeSH terms: Disinfection
  2. Veerachamy S, Yarlagadda T, Manivasagam G, Yarlagadda PK
    Proc Inst Mech Eng H, 2014 Oct;228(10):1083-99.
    PMID: 25406229 DOI: 10.1177/0954411914556137
    Biofilms are a complex group of microbial cells that adhere to the exopolysaccharide matrix present on the surface of medical devices. Biofilm-associated infections in the medical devices pose a serious problem to the public health and adversely affect the function of the device. Medical implants used in oral and orthopedic surgery are fabricated using alloys such as stainless steel and titanium. The biological behavior, such as osseointegration and its antibacterial activity, essentially depends on both the chemical composition and the morphology of the surface of the device. Surface treatment of medical implants by various physical and chemical techniques are attempted in order to improve their surface properties so as to facilitate bio-integration and prevent bacterial adhesion. The potential source of infection of the surrounding tissue and antimicrobial strategies are from bacteria adherent to or in a biofilm on the implant which should prevent both biofilm formation and tissue colonization. This article provides an overview of bacterial biofilm formation and methods adopted for the inhibition of bacterial adhesion on medical implants.
    Matched MeSH terms: Disinfection/methods*
  3. Junaid Tahir M, Rizwan Siddiqi A, Ullah I, Ahmed A, Dujaili J, Saqlain M
    PMID: 33816368 DOI: 10.47176/mjiri.34.169
    Pakistan has recently been overwhelmed by extreme torrential rains, with its most populous city of Karachi experiencing its worst floods in almost a century. Poor flood control and water disposal facilities have led to an immense risk of another dengue outbreak, with multiple cases being reported recently. The enormous accumulation of stagnant water in urban areas is a major source of mosquito breeding and transmission. Historical data has shown the correlation between the number of dengue cases and average rainfall in the region. The monsoon rains have pounded at a time where health authorities are battling to contain the Coronavirus (COVID-19) pandemic. There is a need to implement centralized dengue control strategies to undertake large scale water drainage, sanitation, and disinfection drives in disaster-stricken areas alongside public health awareness programs to combat the after-effects of this natural calamity.
    Matched MeSH terms: Disinfection
  4. Sheikh J, Swee TT, Saidin S, Yahya AB, Malik SA, Yin JSS, et al.
    Med Biol Eng Comput, 2021 May;59(5):1055-1063.
    PMID: 33866479 DOI: 10.1007/s11517-021-02360-8
    Ultraviolet-C sourced LED (UVC-LED) has been widely used for disinfection purposes due to its germicidal spectrum. In this study, the efficiencies of UVC-LED for Pseudomonas aeruginosa (P. aeruginosa) and Staphylococcus aureus (S. aureus) disinfections were investigated at three exposure distances (1, 1.5, and 2 cm) and two exposure times (30 and 60 s). The respective bacterial inhibition zones were measured, followed by a morphological analysis under SEM. The viabilities of human skin fibroblast cells were further evaluated under the treatment of UVC-LED with the adoption of aforesaid exposure parameters. The inhibition zones were increased with the increment of exposure distances and times. The highest records of 5.40 ± 0.10 cm P. aeruginosa inhibition and 5.43 ± 0.11 cm S. aureus inhibition were observed at the UVC-LED distance of 2 cm and 60-s exposure. Bacterial physical damage with debris formation and reduction in size were visualized following the UVC-LED exposures. The cell viability percentages were in a range of 75.20-99.00% and 82-100.00% for the 30- and 60-s exposures, respectively. Thus, UVC-LED with 275-nm wavelength is capable in providing bacterial disinfection while maintaining accountable cell viability which is suitable to be adopted in wound treatment. Bacterial disinfection and human skin fibroblast cell assessment using UVC-LED.
    Matched MeSH terms: Disinfection*
  5. Fernando WJ, Othman R
    Math Biosci, 2006 Feb;199(2):175-87.
    PMID: 16387333
    Disinfectants are generally used to inactivate microorganisms in solutions. The process of inactivation involves the disinfectant in the liquid diffusing towards the bacteria sites and thereafter reacting with bacteria at rates determined by the respective reaction rates. Such processes have demonstrated an initial lag phase followed by an active depletion phase of bacteria. This paper attempts to study the importance of the combined effects of diffusion of the disinfectant through the outer membrane of the bacteria and transport through the associated concentration boundary layers (CBLs) during the initial lag phase. Mathematical equations are developed correlating the initial concentration of the disinfectant with time required for reaching a critical concentration (C*) at the inner side of the membrane of the cell based on diffusion of disinfectant through the outer membranes of the bacteria and the formation of concentration boundary layers on both sides of the membranes. Experimental data of the lag phases of inactivation already available in the literature for inactivation of Bacillus subtilis spores with ozone and monochloramine are tested with the equations. The results seem to be in good agreement with the theoretical equations indicating the importance of diffusion process across the outer cell membranes and the resulting CBL's during the lag phase of disinfection.
    Matched MeSH terms: Disinfection/methods
  6. Aizah N, Su Y, Shaifulnizam C, MRos M
    Malays Orthop J, 2014 Jul;8(2):66-8.
    PMID: 25279099 MyJurnal DOI: 10.5704/MOJ.1407.015
    Extruded bone is a rare complication of high energy open fractures, and there is only a handful of literature on reimplantation of the extruded segment. No clear guidelines exist regarding timing of reimplantation, stabilization of extruded bone segments, and also bone disinfection and sterilization techniques. Previous reports describe sterilization using thermal or chemical methods. We present a case of successful reimplantation of an extruded metaphyseal segment of femur after gamma sterilization in a fourteen- year old boy.
    Matched MeSH terms: Disinfection
  7. Aws Hashim Ali Al-Kadhim, Azlan Jaafar, Mohd Nazrin Isa
    MyJurnal
    Nonsurgical retreatment involves removing mechanical barriers such as gutta-percha to achieve proper cleaning and disinfection. The complexity of the anatomy of molar tooth gives challenge in retreatment procedure. Thus, this study evaluates the amount of residual gutta-percha after retreatment with rotary files (Reciproc Blue®) from each maxillary first molar canal using cone-beam computed tomography (CBCT) and the time required to accomplish it. Nine freshly extracted maxillary molars were instrumented and obturated. Preoperative CBCT was taken, and retreatment was done using Reciproc Blue®. CBCT was taken post retreatment, and the residual volume percentage of gutta-percha from each canal was calculated. The total retreatment time was recorded, and the data were statistically analyzed. The result shows no statistically significant difference in the amount of residual filling material in mesiobuccal, distobuccal, and palatal canal for maxillary first molar and total time used for retreatment with Reciproc Blue® system.

    Matched MeSH terms: Disinfection
  8. Zin, Thant, SabaiAung, Tin, Sahipudin Saupin, Myint, Than, KhinSN, Daw, Aung, Meiji Soe, et al.
    MyJurnal
    The lower percentage of water, sanitation and hygiene are the root causes of diarrhoea and cholera. Cholera is a sudden onset of acute watery diarrhoea which can progress to severe dehydration and death if untreated. The current pandemic, Vibrio Cholera O1 started in 1961. This study explores water, sanitation, hygiene and cholera and diarrhoea in three affected villages of Beluran District, Sabah Malaysia to support effective and timely public health intervention. This cross sectional study uses purposive sampling. All (114) households were interviewed and household water samples collected. The study reported lower coverage improved sanitation facilities (35.3% to 52.3%), no latrine at home (37% to 63%), improved water supply (52% to 60%), and prevalence of hand washing after toilet (57% - 74%). For water quality, Ecoli was present in household water (32% to 37%) but Vibrio cholerae was not isolated in any of the water samples tested. Statistically significant associations were found for; 1) occupation−nonagriculture and unimproved sanitation facility and 2) house ownership and correct knowledge of ORS preparation. Predictors for household water quality were: latrine at home, and improved household toilet. Aggressive strategies to improve water supply, sanitation and hygiene−hand washing after toilet−were recommended for future prevention of cholera and diarrhoea in the affected area.
    Matched MeSH terms: Hand Disinfection
  9. Rasid, M.A., Quah, B.S., Pennie, R.A.
    MyJurnal
    The aim of this paper was to study hand washing practices in the Neonatal Intensive Care Unit (NICU), Hospital Universiti Sains Malaysia. All medical personnel handling babies in the NICU were observed without their knowledge for a total of three times before and after an educational intervention between November 1, 1993 and December 31, 1993. Hand washing techniques with both Hibisol Spray and Chlorhexidine were scored from 1-4. The results of the study are shown as follows: the number of personnel observed were: before educational intervention -paediatric doctors (PD) 14, non-paediatric doctors (ND) 13 and nurses (N) 48; after educational intervention - PD 10 , ND 12 and N 42. PD and N washed hands significantly more often than ND (p < 0.001), before and after intervention. PD but not ND or N improved their rate of hand washing after educational intervention PD (p= 0.02). The Hibisol handwashing technique was poor in all groups (77.1% of all observations). The Chlorhexidine hand washing technique was better than Hibisol (p<0.0001). However only 15% of observed washes with Chlorhexidine were well done and almost one third were done poorly. Both Hibisol and Chlorhexidine techniques did not improve after educational intervention. Hand washing was performed more often in the Level III than Level II nursery [85% of all observations in Level III and 73% of all observations in Level II, p=0.002]. In conclusion, the present educational program is not sufficient and more direct means should be taken to improve the frequency of hand washing among all medical personnel. All medical personnel in the NICU should be educated in the use of the Hibisol, otherwise Hibisol should be removed from the nursery.
    Keywords: Handwashing, doctors, neonatal intensive care unit, nurses
    Study site: Hospital Universiti Sains Malaysia, Kelantan, Malaysia
    Matched MeSH terms: Hand Disinfection
  10. Faizah, J., Vanitha, S.
    MyJurnal
    Introduction : The focus of this paper is to evaluate effectiveness of health education material produced and identify effective educational methods in disseminating health-related information. The study explores the knowledge, attitude and practice level among flood victims in Sub-District Sri Medan, Batu Pahat.
    Methodology : Convenient sampling method was adopted as a technique to get 195 respondents aged 18 years and above who had stayed in flood relief centres in the district. A set of questionnaire designed to collect data on demography, effectiveness of health education material, accessibility to education materials, preferable educational methods during flood situation, and flood victims knowledge, attitude and practices.
    Result : The study found no association between knowledge level and practice of seven steps hand washing. Result showed poster was regarded as most preferable method in disseminating health related information during flood. No association was found in demographic determinants and knowledge. The length of stay in relief centre has significant association with the level of knowledge obtained.
    Conclusion : The use of qualitative and quantitative methods together able to determine accurately the effectiveness of the health education materials used during the disaster as well as the impact in behavioral change.
    Matched MeSH terms: Hand Disinfection
  11. Wong KS, Lim WTH, Ooi CW, Yeo LY, Tan MK
    Lab Chip, 2020 05 19;20(10):1856-1868.
    PMID: 32342089 DOI: 10.1039/d0lc00001a
    The presence of reactive species in plasma-activated water is known to induce oxidative stresses in bacterial species, which can result in their inactivation. By integrating a microfludic chipscale nebulizer driven by surface acoustic waves (SAWs) with a low-temperature atmospheric plasma source, we demonstrate an efficient technique for in situ production and application of plasma-activated aerosols for surface disinfection. Unlike bulk conventional systems wherein the water is separately batch-treated within a container, we show in this work the first demonstration of continuous plasma-treatment of water as it is transported through a paper strip from a reservoir onto the chipscale SAW device. The significantly larger surface area to volume ratio of the water within the paper strip leads to a significant reduction in the duration of the plasma-treatment, while maintaining the concentration of the reactive species. The subsequent nebulization of the plasma-activated water by the SAW then allows the generation of plasma-activated aerosols, which can be directly sprayed onto the contaminated surface, therefore eliminating the storage of the plasma-activated water and hence circumventing the typical limitation in conventional systems wherein the concentration of the reactive species diminishes over time during storage, resulting in a reduction in the efficacy of bacterial inactivation. In particular, we show up to 96% reduction in Escherichia coli colonies through direct spraying with the plasma-activated aerosols. This novel, low-cost, portable and energy-efficient hybrid system necessitates only minimal maintenance as it only requires the supply of tap water and battery power for operation, and is thus suitable for decontamination in home environments.
    Matched MeSH terms: Disinfection*
  12. Jameleddine Chtioui M, Harzallah N, Odabachian Jebali MC, Grati H, Njeh M, Dhidah L, et al.
    Tunis Med, 2021 1 23;98(8-9):651-655.
    PMID: 33480021
    OBJECTIVES: Industries have made claims on the effectiveness of a disinfection procedure in reducing COVID-19 transmission. This procedure is usually performed by automated dispersion of disinfectant on individuals when they go through a booth. This Health Technology Assessment (HTA) report is a systematic review that synthesizes the evidence on the efficacy and safety of using these booths and provides recommendations to the Ministry of Health to facilitate decision-making regarding the relevance of using this technology.

    METHODS: A systematic literature review was performed using Pubmed, Web of Science, INAHTA and GIN databases, from inception to June 4, 2020. Three independent reviewers selected eligible studies then extracted and synthesized the evidence. The synthesis was submitted to a multidisciplinary group of experts to provide recommendations.

    RESULTS: Two scientific papers and a Malaysian HTA report were included in data synthesis. In light of the resources consulted, spraying disinfectants on humans in booths is not effective and can be toxic. Disinfectants are intended for use on surfaces, not on living tissue and spraying disinfectants on the outside of the body does not kill the virus inside an infected person's body. Furthermore, this procedure may increase the risk of neglecting other effective measures.

    CONCLUSION: It is recommended to prohibit the use of disinfection booths in all structures.

    Matched MeSH terms: Disinfection/instrumentation*
  13. Goh, S.H., Khor, K.H., Lau, S.F., Ismail, R., Khairani-Bejo, S., Radzi, R.
    Jurnal Veterinar Malaysia, 2019;31(1):17-27.
    MyJurnal
    Dogs could be reservoirs and carriers of Leptospira spp., hence, may play a potential role in disease transmission, exposing dog handlers to leptospirosis. This study evaluated the dog handlers’ knowledge, attitude and practice (KAP) towards leptospirosis. Four working dog and four dog shelter organisations were approached. A total of 138 dog handlers were conveniently recruited and evaluated on their level of knowledge, attitude and practice towards leptospirosis using a validated structured questionnaire. Most of the dog handlers were male aged between 30 and 40 years with a wide range of working experience of 1 - 10 years and all of them have no formal training about leptospirosis. The majority of the dog handlers from the dog shelters had poor knowledge (90%, n=34/38) and attitude (100%, n=38/38) and moderate practice (53%, n=20/38) towards leptospirosis, whereas the working dog handlers had poor knowledge (58%, n=58/100) and attitude (75%, n=75/100) but a good level of practice (77%, n=77/100). The poor attitude towards leptospirosis in both groups is alarming as it may hinder implementation plans of control and preventive measures. Although there was good hand-washing practices among the dog handlers, there was a lack of personal protective equipment (PPE) practice that may therefore expose both the dogs and dog handlers to leptospirosis. Information gained from this study could be used to implement intervention programmes and to suggest prevention measures to limit the risk of leptospirosis among the dog handlers.
    Matched MeSH terms: Hand Disinfection
  14. Norhani Mohidin, Tee, Lee Fung
    MyJurnal
    This survey represents an initial examination of contact lens practice in Malaysia. It is based on a questionnaire that was sent to selected members of the Association of the Malaysian Optometrists to survey the prescribing habits of g contact lenses and care products. Questions included types of lenses prescribed, care systems frequently recommended and types of complications seen. Optometrists in Malaysia prescribed an average of 90 new pairs of contact lenses per year. Soft lenses made up 84% of the prescription followed by 14% of rigid gas permeable lenses and 1.5% of polymethymethacrylate lenses. Disposable/frequent replacement lenses accounted for 60% of the soft lenses prescribed. The most commonly prescribed disinfecting system was chemical disinfection. The most common complication seen during aftercare consultation was dry eye-related problems.
    Matched MeSH terms: Disinfection
  15. Hashim S, Ayub ZN, Mohamed Z, Hasan H, Harun A, Ismail N, et al.
    J Travel Med, 2016 Feb;23(2):tav019.
    PMID: 26858268 DOI: 10.1093/jtm/tav019
    BACKGROUND: Respiratory illness continues to exert a burden on hajj pilgrims in Makkah. The purpose of this study is to determine the prevalence of respiratory illness and its associated factors among Malaysian hajj pilgrims in 2013 and to describe its preventive measures.

    METHODS: A cross-sectional study was conducted in Makkah and Malaysia during the 2013 hajj season. A self-administered proforma on social demographics, previous experience of hajj or umrah, smoking habits, co-morbid illness and practices of preventive measures against respiratory illness were obtained.

    RESULTS: A total of 468 proforma were analysed. The prevalence of the respiratory illness was 93.4% with a subset of 78.2% fulfilled the criteria for influenza-like illness (ILI). Most of them (77.8%) had a respiratory illness of <2 weeks duration. Approximately 61.8% were administered antibiotics but only 2.1% of them had been hospitalized. Most of them acquired the infection after a brief stay at Arafat (81.2%). Vaccination coverages for influenza virus and pneumococcal disease were quite high, 65.2% and 59.4%, respectively. For other preventive measures practices, only 31.8% of them practiced good hand hygiene, ∼82.9% of pilgrims used surgical face masks, N95 face masks, dry towels, wet towels or veils as their face masks. Nearly one-half of the respondents (44.4%) took vitamins as their food supplement. Malaysian hajj pilgrims with previous experience of hajj (OR 0.24; 95% CI 0.10-0.56) or umrah (OR 0.19; 95% CI 0.07-0.52) and those who have practiced good hand hygiene (OR 0.35; 95% CI 0.16-0.79) were found to be significantly associated with lower risk of having respiratory illness. Otherwise, pilgrims who had contact with those with respiratory illness (OR 2.61; 95% CI 1.12-6.09) was associated with higher risk.

    CONCLUSIONS: The prevalence of respiratory illness remains high among Malaysian hajj pilgrims despite having some practices of preventive measures. All preventive measures which include hand hygiene, wearing face masks and influenza vaccination must be practiced together as bundle of care to reduce respiratory illness effectively.

    Matched MeSH terms: Hand Disinfection
  16. Haque M
    J Popul Ther Clin Pharmacol, 2020 07 12;27(S Pt 1):e37-e52.
    PMID: 32757544 DOI: 10.15586/jptcp.v27SP1.711
    After officially declared as a pandemic by the World Health Organization (WHO), drastic measures to restrict human movements to contain the COVID-19 infection are employed by most of the countries. Maintaining high personal hygiene by frequent handwashing and be vigilant of clinical signs are widely recommended to reduce the disease burden. The national and international health agencies, including the Centers for Disease Control and Prevention (CDC) and the WHO, have provided guidelines for prevention and treatment suggestions. Here, in this brief article, based on available clinical information, the author discusses why handwashing could be protective of COVID-19 infections. Although a detailed and in-depth discussion of various preventive and protective measures is beyond the scope of this article, this review will focus on the utility of frequent handwashing in minimizing the risk of spreading COVID-19 infection.
    Matched MeSH terms: Hand Disinfection/standards*
  17. Siah KTH, Rahman MM, Ong AML, Soh AYS, Lee YY, Xiao Y, et al.
    J Neurogastroenterol Motil, 2020 07 30;26(3):299-310.
    PMID: 32606253 DOI: 10.5056/jnm20107
    During the Coronavirus Disease 2019 (COVID-19) pandemic, practices of gastrointestinal procedures within the digestive tract require special precautions due to the risk of contraction of severe acute respiratoy syndrome coronavirus-2 (SARS-CoV-2) infection. Many procedures in the gastrointestinal motility laboratory may be considered moderate to high-risk for viral transmission. Healthcare staff working in gastrointestinal motility laboratories are frequently exposed to splashes, air droplets, mucus, or saliva during the procedures. Moreover, some are aerosol-generating and thus have a high risk of viral transmission. There are multiple guidelines on the practices of gastrointestinal endoscopy during this pandemic. However, such guidelines are still lacking and urgently needed for the practice of gastrointestinal motility laboratories. Hence, the Asian Neurogastroenterology and Motility Association had organized a group of gastrointestinal motility experts and infectious disease specialists to produce a position statement paper based-on current available evidence and consensus opinion with aims to provide a clear guidance on the practices of gastrointestinal motility laboratories during the COVID-19 pandemic. This guideline covers a wide range of topics on gastrointestinal motility activities from scheduling a motility test, the precautions at different steps of the procedure to disinfection for the safety and well-being of the patients and the healthcare workers. These practices may vary in different countries depending on the stages of the pandemic, local or institutional policy, and the availability of healthcare resources. This guideline is useful when the transmission rate of SARS-CoV-2 is high. It may change rapidly depending on the situation of the epidemic and when new evidence becomes available.
    Matched MeSH terms: Disinfection
  18. Tandon RK
    J Gastroenterol Hepatol, 1991 1 1;6(1):37-9.
    PMID: 1883975
    Matched MeSH terms: Disinfection/standards*
  19. Shah NNAK, Supian NAM, Hussein NA
    J Food Sci Technol, 2019 Jan;56(1):262-272.
    PMID: 30728568 DOI: 10.1007/s13197-018-3486-2
    This work studied the effectiveness of gaseous ozone disinfection on pummelo (Citrus Grandis L. Osbeck) fruit juice components. Unfiltered and filtered pummelo fruit juices were treated with gaseous ozone for up to 50 min with ozone concentration fixed at 600 mg/h. A microbiological and physicochemical properties analysis were conducted on the ozone-treated fruit juices samples. It was found that the survival rate of aerobic bacteria, yeast and mold in unfiltered pummelo fruit juice were higher compared to filtered juice, as the juice components acted as protective barriers to the microorganisms. The microorganisms' inactivation in pummelo fruit juices was also observed to have increased as the ozone treatment time increased. Significant effects on total colour difference, ascorbic acid content, and total phenolic content were also observed over increased ozone-treatment time. However, ozone was shown to be ineffective in activating PME activity in both types of juice. The experimental results of this study indicated that pummelo fruit juice components had significant effects on the effectiveness of gaseous ozone, however, the degree of the effects depends on the different fruit components (total soluble solids, total phenolic content). As a conclusion, filtered juice showed better quality characteristics in comparison to unfiltered juice post-ozone treatment.
    Matched MeSH terms: Disinfection
  20. Bidawid S, Malik N, Adegbunrin O, Sattar SA, Farber JM
    J Food Prot, 2004 Jan;67(1):103-9.
    PMID: 14717359
    While there is good epidemiological evidence for foods as vehicles for norovirus transmission, the precise means of spread and its control remain unknown. The feline calicivirus was used as a surrogate for noroviruses to study infectious virus transfer between hands and selected types of foods and environmental surfaces. Assessment of the potential of selected topicals in interrupting such virus transfer was also made. Ten microliters of inoculum of feline calicivirus deposited onto each fingerpad of adult subjects was allowed to air dry and the contaminated area on individual fingerpads was pressed (10 s at a pressure of 0.2 to 0.4 kg/cm2) onto 1-cm-diameter disks of ham, lettuce, or brushed stainless steel. The virus remaining on the donor and that transferred to the recipient surfaces was eluted and plaque assayed. Virus transfer to clean hands from experimentally contaminated disks of ham, lettuce, and stainless steel was also tested. Nearly 46 +/- 20.3, 18 +/- 5.7, and 13 +/- 3.6% of infectious virus was transferred from contaminated fingerpads to ham, lettuce, and metal disks, respectively. In contrast, approximately 6 +/- 1.8, 14 +/- 3.5, and 7 +/- 1.9% virus transfer occurred, respectively, from ham, lettuce, and metal disks to hands. One-way analysis of variance test showed that pretreatment (washing) of the fingerpads either with water or with both topical agent and water significantly (P < 0.05) reduced virus transfer to < or = 0.9%, as compared with < or = 2.3 and < or = 3.4% transfer following treatments with either 75% (vol/vol) ethanol or a commercial hand gel containing 62% ethanol, respectively. Despite wide variations in virus transfer among the targeted items used, intervention agents tested reduced virus transfer significantly (P < 0.05) when compared with that without such treatments (71 +/- 8.9%). These findings should help in a better assessment of the potential for cross-contamination of foods during handling and also assist in developing more effective approaches to foodborne spread of norovirus infections.
    Matched MeSH terms: Disinfection/methods; Hand Disinfection
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links