Displaying publications 21 - 34 of 34 in total

Abstract:
Sort:
  1. Muhammad R, Johann KF, Saladina JJ, Mohd Latar NH, Niza ASS
    Med J Malaysia, 2013 Jun;68(3):204-7.
    PMID: 23749007 MyJurnal
    Treatment for breast cancer has improved dramatically over the decades. Nevertheless, modified radical mastectomy with axillary dissection remains the standard treatment for most patients, especially those with big tumours. The conventional technology is to use diathermy to cut and coagulate blood vessels. The Ultracision dissector has been widely used in laparoscopic surgery and is documented to be safe and fast for cutting and coagulating tissue. The aim of this study is to compare ultracision to electrocautery, looking in terms of amount of post operative drainage, duration of drain days, seroma formation and other complications.
    Matched MeSH terms: Electrocoagulation
  2. Naje AS, Chelliapan S, Zakaria Z, Abbas SA
    J Environ Manage, 2016 Jul 1;176:34-44.
    PMID: 27039362 DOI: 10.1016/j.jenvman.2016.03.034
    This paper investigates the optimum operational conditions of a novel rotated bed electrocoagulation (EC) reactor for the treatment of textile wastewater. The effect of various operational parameters such as rotational speed, current density (CD), operational time (RT), pH, temperature, and inter-electrode distance (IED) on the pollutant removal efficiency were examined. In addition, the consumption of aluminum (Al) and electrical energy, as well as operating costs at optimum conditions were also calculated. The results indicated that the optimum conditions for the treatment of textile wastewater were achieved at CD = 4 mA/cm(2), RT = 10 min, rotational speed = 150 rpm, pH = 4.57, temperature = 25 °C, and IED = 1 cm. The electrode consumption, energy consumption, and operating costs were 0.038 kg/m(3), 4.66 kWh/m(3) and 0.44 US$/m(3), respectively. The removal efficiencies of chemical oxygen demand (COD), biological oxygen demand (BOD), total suspended solid (TSS), turbidity and color were 97.10%, 95.55%, 98%, 96% and 98.50%, respectively, at the first 10 min of reaction time, while the phenol compound of the wastewater was almost entirely removed (99.99%). The experimental results confirm that the new reactor design with rotated anode impellers and cathode rings provided high treatment efficiency at a reduced reaction time and with lower energy consumption.
    Matched MeSH terms: Electrocoagulation
  3. Naje AS, Ajeel MA, Ali IM, Al-Zubaidi HAM, Alaba PA
    Water Sci Technol, 2019 Aug;80(3):458-465.
    PMID: 31596257 DOI: 10.2166/wst.2019.289
    In this work, landfill leachate treatment by electrocoagulation process with a novel rotating anode reactor was studied. The influence of rotating anode speed on the removal efficiency of chemical oxygen demand (COD), total dissolved solids (TDS), and total suspended solids (TSS) of raw landfill leachate was investigated. The influence of operating parameters like leachate pH, leachate temperature, current, and inter-distance between the cathode rings and anode impellers on the electrocoagulation performance were also investigated. The results revealed the optimum rotating speed is 150 rpm and increasing the rotating speed above this value led to reducing process performance. The leachate electrocoagulation treatment process favors the neutral medium and the treatment performance increases with increasing current intensity. Furthermore, the electrocoagulation treatment performance improves with increasing leachate temperature. However, the performance reduces with increasing inter-electrode distance.
    Matched MeSH terms: Electrocoagulation
  4. Nasution MA, Yaakob Z, Ali E, Tasirin SM, Abdullah SR
    J Environ Qual, 2011 Jul-Aug;40(4):1332-9.
    PMID: 21712603 DOI: 10.2134/jeq2011.0002
    Palm oil mill effluent (POME) is highly polluting wastewater generated from the palm oil milling process. Palm oil mill effluent was used as an electrolyte without any additive or pretreatment to perform electrocoagulation (EC) using electricity (direct current) ranging from 2 to 4 volts in the presence of aluminum electrodes with a reactor volume of 20 L. The production of hydrogen gas, removal of chemical oxygen demand (COD), and turbidity as a result of electrocoagulation of POME were determined. The results show that EC can reduce the COD and turbidity of POME by 57 and 62%, respectively, in addition to the 42% hydrogen production. Hydrogen production was also helpful to remove the lighter suspended solids toward the surface. The production of Al(OH)XHO at the aluminum electrode (anode) was responsible for the flocculation-coagulation process of suspended solids followed by sedimentation under gravity. The production of hydrogen gas from POME during EC was also compared with hydrogen gas production by electrolysis of tap water at pH 4 and tap water without pH adjustment under the same conditions. The main advantage of this study is to produce hydrogen gas while treating POME with EC to reduce COD and turbidity effectively.
    Matched MeSH terms: Electrocoagulation/instrumentation; Electrocoagulation/methods*
  5. Nur Syuhaidah Mohd Aris, Shariff Ibrahim, Borhannuddin Arifin, Yahaya Hawari
    MyJurnal
    Electrocoagulation has proven to be an effective method in the treatment of wastewater. This study evaluated the decolourisation of Palm Oil Mill Effluent (POME) using electrocoagulation (EC) batch reactor by utilising aluminium as sacrificial electrode. POME sample source from a final discharged pond at a palm oil mill was characterised for its colour, chemical oxygen demand (COD), pH, conductivity and turbidity; were found to be 2707 PtCo, 3909 mg/L, 7.63, 12.82 mS/cm and 755 NTU respectively. The respective effects of operating parameters such as pH (3 to 11), applied voltage (5 V to 20 V), plate gap (7.5 to 11.5 cm) and operating time (1 to 8 hours) were investigated. The decolourisation of POME was observed to increase with increasing voltage and operating time. Highest removal efficiency was observed at pH 5, 20 V applied voltage, 9.5 cm plate gap and at 8-hour operating time with colour removal efficiency of 89, 79, 78 and 64% respectively. From the findings, it can be concluded that electrocoagulation process using aluminium electrodes is a reliable technique for the removal of colour from POME.
    Matched MeSH terms: Electrocoagulation
  6. Pui WC, Chieng TH, Siow SL, Nik Abdullah NA, Sagap I
    Asian Pac J Cancer Prev, 2020 Oct 01;21(10):2927-2934.
    PMID: 33112550 DOI: 10.31557/APJCP.2020.21.10.2927
    BACKGROUND: Various methods have been used for treatment of hemorrhagic radiation proctitis (HRP) with variable results. Currently, the preferred treatment is formalin application or endoscopic therapy with argon plasma coagulation. Recently, a novel therapy with colonic water irrigation and oral antibiotics showed promising results and more effective compared to 4% formalin application for HRP. The study objective is to compare the effect of water irrigation and oral antibiotics versus 4% formalin application in improving per rectal bleeding due to HRP and related symptoms such as diarrhoea, tenesmus, stool frequency, stool urgency and endoscopic findings.

    METHODS: We conducted a study on 34 patients with HRP and randomly assigned the patients to two treatment arm groups (n=17). The formalin group underwent 4% formalin dab and another session 4 weeks later. The irrigation group self-administered daily rectal irrigation at home for 8 weeks and consumed oral metronidazole and ciprofloxacin during the first one week. We measured the patients' symptoms and endoscopic findings before and after total of 8 weeks of treatment in both groups.

    RESULTS: Our study showed that HRP patients had reduced per rectal bleeding (p = 0.003) in formalin group, whereas irrigation group showed reduced diarrhoea (p=0.018) and tenesmus (p=0.024) symptoms. The comparison between the two treatment arms showed that irrigation technique was better than formalin technique for tenesmus (p=0.043) symptom only.

    CONCLUSION: This novel treatment showed benefit in treating HRP. It could be a new treatment option which is safe and conveniently self-administered at home or used as a combination with other therapies to improve the treatment outcome for HRP.
    .

    Matched MeSH terms: Electrocoagulation/methods*
  7. Rajendren, S. K., Krishnan, K., Ganesh, T. N., Roslan, N. S., Hashim, N. A., Mohamad, M. A.
    Jurnal Veterinar Malaysia, 2019;31(2):19-22.
    MyJurnal
    A 5-year-old Mongrel was brought presented with the complaint of having serosanguineous discharge from penis for a month since adoption. Physical examination revealed cauliflower-like mass at the bulbus glandis. Presence of numerous anisokaryotic and anisocytotic round to oval histiocytes with multivacuolated cytoplasm from cytology, an evidence of canine transmissibale venereal tumour (CTVT). The mass was successfully surgically resected using electrocautery and was in remission for 12 months (since January 2019).
    Matched MeSH terms: Electrocoagulation
  8. Rakhmania, Kamyab H, Yuzir MA, Al-Qaim FF, Purba LDA, Riyadi FA
    Environ Sci Pollut Res Int, 2023 Jun;30(28):71741-71753.
    PMID: 34480301 DOI: 10.1007/s11356-021-16197-z
    In this study, palm oil mill effluent (POME) was treated using electrocoagulation, whereby the influencing factors including voltage, electrolysis time, and electrolyte amount were optimized to achieve the highest chemical oxygen demand (COD) and color removal efficiencies. Graphite was selected as electrode material due to its performance better compared to aluminum and copper. Response surface methodology (RSM) was carried out for optimization of the electrocoagulation operating parameters. The best model obtained using Box-Behnken design (BBD) were quadratic for COD removal (R2 = 0.9844), color reduction (R2 = 0.9412), and oil and grease removal (R2 = 0.9724). The result from the analysis of variance (ANOVA) was obtained to determine the relationship between factors and treatment efficiencies. The experimental results under optimized conditions such as voltage 14, electrolysis time of 3 h, and electrolyte amount of 13.41 g/L show that the electrocoagulation process effectively reduced the COD (56%), color (65%), and oil and grease (99%) of the POME treatment. Graphical abstract.
    Matched MeSH terms: Electrocoagulation/methods
  9. Singh AH
    Scott Med J, 2011 Feb;56(1):59.
    PMID: 21515535 DOI: 10.1258/smj.2010.010026
    A 3-year old girl presented to our A&E with a complaint of an acute event of per rectal bleed. The parent had given a history of a visit to a nearby waterfall one day ago. Upon admission she developed hypotension and had a fainting episode due to the excessive passing of blood per rectum. The case report shows how the appropriate investigations were carried out and the twist behind the cause.
    Matched MeSH terms: Electrocoagulation
  10. Suresh N, Chandrasekaran B, Muthusamy S, Kannan S, Muthu K
    Singapore Dent J, 2015 Dec;36:39-43.
    PMID: 26684495 DOI: 10.1016/j.sdj.2014.11.004
    BACKGROUND: Application of principles of electrocautery for hemostasis dates back to prehistoric times. Its modern implementation in various fields of general and head and neck surgeries have been well documented. However its usage in minor oral surgical procedures has gained popularity only recently. Complications associated with electro-surgery in the dental field are relatively rare and there is insufficient literature on its management.

    CASE REPORT: We present a case report on management of an electrosurgery induced osteonecrosis involving maxillary alveolus of left premolars.

    DISCUSSION: Inadvertent contact of the electrosurgery tip on bone can result in necrosis making it necessary to remove the sequestrum and graft the defect. Platelet rich fibrin in combination with bone grafts have been well documented to provide successful periodontal regeneration.

    CLINICAL IMPLICATIONS: Our aim of presenting this report is to create awareness among the health care providers regarding electrosurgical injuries. To our knowledge, this is the first time platelet rich fibrin has been used in the management of intraoral electrosurgical injury. Combining bone grafts with platelet rich fibrin is a good alternative as it can be done with relative ease and predictable outcome.

    Matched MeSH terms: Electrocoagulation
  11. Tan LS, Daud MH, Nasirudin N
    J Hand Surg Asian Pac Vol, 2018 Dec;23(4):577-580.
    PMID: 30428790 DOI: 10.1142/S2424835518720335
    Pyogenic granuloma, also known as lobular capillary hemangioma, is a benign vascular lesion of the skin or mucous membrane with rapid growth or repetitive trauma. Rarely seen in adult, its management varies and surgical intervention is usually common. We report a case of pyogenic granuloma of the right index finger in a 46-year-old gentleman who presented with painless swelling of the right index finger after a trivial injury. Wedge biopsy confirmed the diagnosis and excision of the granuloma measuring 3 cm × 3 cm × 2 cm was done with curettage and electrocautery over the base of granuloma. The wound subsequently healed well with good functional and aesthetic outcome.
    Matched MeSH terms: Electrocoagulation/methods*
  12. Wong JL, Tie ST, Lee J, Kannan SK, Rashid Ali MR, Ibrahim A, et al.
    Med J Malaysia, 2014 Aug;69(4):195-6.
    PMID: 25500852 MyJurnal
    Recurrent respiratory papillomatosis (RRP) is a benign disease caused by the human papilloma virus (HPV), characterized by the formation of recurrent, epithelial neoplastic lesions in the airways. While benign, they can cause significant airway obstruction in some cases. Difficulties in treatment arise from the recurrent nature of the lesions despite repeated procedures. Other known procedures that result in deep tissue damage also cause unacceptable collateral damage to the underlying airway mucosa. We describe a case of recurrent papillomatosis that was successfully treated with argon plasma coagulation ( APC) when laser and electrocautery ablation had failed in the past. After the papillomatasis was treated with APC, there is no recurrence on repeat scope at 4 months and 9 months after the initial procedure. The procedure was done as a day case and there is no complication from the procedure. The property of the APC that allows it to cause only superficial thermal damage to the tissue makes it a suitable adjunct therapy to the treatment of papillomas, which are usually superficial lesions.
    Matched MeSH terms: Electrocoagulation
  13. Yap FB
    Trans R Soc Trop Med Hyg, 2010 Feb;104(2):168-9.
    PMID: 19766279 DOI: 10.1016/j.trstmh.2009.05.016
    A retrospective study was conducted to determine the clinical characteristics and treatment outcomes of 11 new patients with a histological diagnosis of chromoblastomycosis at Sarawak General Hospital, Malaysia, between 1996 and 2008. The majority (81.8%) were males, and the median age at presentation was 40 years. Over half the patients were farmers. All the patients had irregular verrucous lesions, mostly on the lower limbs (90.9%), and had initially been misdiagnosed. The mean duration of the lesions was 13.8 years. Oral terbinafine and itraconazole were administered to all the patients; clinical cure was seen in 54.5%, and partial response in 18.2%. Concomitant electrocautery and cryotherapy were only effective for small lesions.
    Matched MeSH terms: Electrocoagulation
  14. Zaied BK, Rashid M, Nasrullah M, Zularisam AW, Pant D, Singh L
    Sci Total Environ, 2020 Jul 15;726:138095.
    PMID: 32481207 DOI: 10.1016/j.scitotenv.2020.138095
    The pharmaceuticals are emergent contaminants, which can create potential threats for human health and the environment. All the pharmaceutical contaminants are becoming enormous in the environment as conventional wastewater treatment cannot be effectively implemented due to toxic and intractable action of pharmaceuticals. For this reason, the existence of pharmaceutical contaminants has brought great awareness, causing significant concern on their transformation, occurrence, risk, and fate in the environments. Electrocoagulation (EC) treatment process is effectively applied for the removal of contaminants, radionuclides, pesticides, and also harmful microorganisms. During the EC process, an electric current is employed directly, and both electrodes are dissoluted partially in the reactor under the special conditions. This electrode dissolution produces the increased concentration of cation, which is finally precipitated as hydroxides and oxides. Different anode materials usage like aluminum, stainless steel, iron, etc. are found more effective in EC operation for efficient removal of pharmaceutical contaminants. Due to the simple procedure and less costly material, EC method is extensively recognized for pharmaceutical wastewater treatment over further conventional treatment methods. The EC process has more usefulness to destabilize the pharmaceutical contaminants with the neutralization of charge and after that coagulating those contaminants to produce flocs. Thus, the review places particular emphasis on the application of EC process to remove pharmaceutical contaminants. First, the operational parameters influencing EC efficiency with the electroanalysis techniques are described. Second, in this review emerging challenges, current developments and techno-economic concerns of EC are highlighted. Finally, future recommendations and prospective on EC are envisioned.
    Matched MeSH terms: Electrocoagulation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links