Displaying publications 21 - 40 of 40 in total

Abstract:
Sort:
  1. Goh, K.L., Zamzuri, Z., Mohd Ariff, S., Mohamed Azril, M.A.
    MyJurnal
    Introduction: Application of dynamic hip screw (DHS) implant for the treatment of unstable intertrochanteric fractures continues to raise concern related to risk of lag screw cut-out with or without subsequent damage to the acetabulum. Measurement of tip-apex distances (TAD) has been recommended to guide the optimal placement of lag screw and to predict subsequent risk of screw cut-out. In this study, the value of TAD was evaluated to verify its usefulness.
    Methods: This is a retrospective study of 33 consecutive patients with intertrochanteric fracture treated with DHS. Demographic data of the patients were traced from their case notes. Post-operative radiographs were reviewed by focusing on measurement of TAD on anteroposterior and lateral radiographs. Radiographs at one year follow-up were reviewed to depict any fixation-related failure or complication.
    Results: Fifty two percent of patients did not achieved the recommended TAD of ≤ 25mm. The mean post-operative TAD was 25.9mm and elderly patients were likely to achieve TAD of ≤ 25mm. The overall complication rate of 6% was attributed to screw cut-out in two cases. The unstable left-sided fracture was identified to be a potential risk for screw cut-out or migration.
    Conclusion: TAD is a valuable measurement to guide optimal placement of lag screw during DHS fixation of intertrochanteric fracture.
    KEYWORDS: Intertrochanteric fracture, dynamic hip screw, tip-apex distance, screw cut-out
    Matched MeSH terms: Hip Prosthesis
  2. Oshkour AA, Talebi H, Shirazi SF, Bayat M, Yau YH, Tarlochan F, et al.
    ScientificWorldJournal, 2014;2014:807621.
    PMID: 25302331 DOI: 10.1155/2014/807621
    This study is focused on finite element analysis of a model comprising femur into which a femoral component of a total hip replacement was implanted. The considered prosthesis is fabricated from a functionally graded material (FGM) comprising a layer of a titanium alloy bonded to a layer of hydroxyapatite. The elastic modulus of the FGM was adjusted in the radial, longitudinal, and longitudinal-radial directions by altering the volume fraction gradient exponent. Four cases were studied, involving two different methods of anchoring the prosthesis to the spongy bone and two cases of applied loading. The results revealed that the FG prostheses provoked more SED to the bone. The FG prostheses carried less stress, while more stress was induced to the bone and cement. Meanwhile, less shear interface stress was stimulated to the prosthesis-bone interface in the noncemented FG prostheses. The cement-bone interface carried more stress compared to the prosthesis-cement interface. Stair climbing induced more harmful effects to the implanted femur components compared to the normal walking by causing more stress. Therefore, stress shielding, developed stresses, and interface stresses in the THR components could be adjusted through the controlling stiffness of the FG prosthesis by managing volume fraction gradient exponent.
    Matched MeSH terms: Hip Prosthesis*
  3. Oshkour AA, Abu Osman NA, Yau YH, Tarlochan F, Abas WA
    Proc Inst Mech Eng H, 2013 Jan;227(1):3-17.
    PMID: 23516951
    This study aimed to develop a three-dimensional finite element model of a functionally graded femoral prosthesis. The model consisted of a femoral prosthesis created from functionally graded materials (FGMs), cement, and femur. The hip prosthesis was composed of FGMs made of titanium alloy, chrome-cobalt, and hydroxyapatite at volume fraction gradient exponents of 0, 1, and 5, respectively. The stress was measured on the femoral prosthesis, cement, and femur. Stress on the neck of the femoral prosthesis was not sensitive to the properties of the constituent material. However, stress on the stem and cement decreased proportionally as the volume fraction gradient exponent of the FGM increased. Meanwhile, stress became uniform on the cement mantle layer. In addition, stress on the femur in the proximal part increased and a high surface area of the femoral part was involved in absorbing the stress. As such, the stress-shielding area decreased. The results obtained in this study are significant in the design and longevity of new prosthetic devices because FGMs offer the potential to achieve stress distribution that more closely resembles that of the natural bone in the femur.
    Matched MeSH terms: Hip Prosthesis*
  4. Tai CC, Nam HY, Abbas AA, Merican AM, Choon SK
    J Arthroplasty, 2009 Dec;24(8):1200-4.
    PMID: 19682839 DOI: 10.1016/j.arth.2009.07.001
    We carried out a prospective study of 47 Exeter (Stryker Inc, Warsaw, Ind) small stem total hip arthroplasty in 42 patients with an average age of 58 years and a mean follow-up of 8.5 years. The Oxford hip score improved from a preoperative mean of 47 to 17 at last follow-up. More than 87% patients had excellent or good Harris hip scores, and 90% were able to walk with little or no pain. Stem subsidence within the cement mantle was observed in 26% of cases, and none showed evidence of aseptic loosening or implant failure. Two stems were removed due to infection. The survival rate of this implant was 95.7% at 10 years. This first series of Exeter small stem showed excellent medium-term results, comparable to its larger counterparts.
    Matched MeSH terms: Hip Prosthesis*
  5. Merican AM, Randle R
    J Arthroplasty, 2006 Sep;21(6):846-51.
    PMID: 16950037
    The Fitmore titanium mesh cementless acetabular component in 115 hip arthroplasties was reviewed at an average of 33 months of follow-up. None were revised nor had infection. One hip dislocated 4 years postoperatively. Two femoral components were revised. The average Harris Hip Score at the last follow-up was 90 points. In the 96 sets of radiographs available, there was no loosening or new radiolucency. One hip had nonprogressive osteolysis adjacent to a screw. This press-fit cup has its polar region flattened and is rim loading. Noncontact (gaps) at the acetabular floor is expected and is not critical for fixation. In all but 6 hips, these gaps filled. In 5 hips, a minimal gap (
    Matched MeSH terms: Hip Prosthesis*
  6. Park KS, Seon JK, Lee KB, Kim SK, Chan CK, Yoon TR
    J Arthroplasty, 2017 02;32(2):503-509.
    PMID: 27546473 DOI: 10.1016/j.arth.2016.07.010
    BACKGROUND: This study aims at determining the average long-term result of revision total hip arthroplasty (THA) using the acetabular reinforcement ring with a hook (ARRH) and bone grafting in severe acetabular bony defect. Expected 15-year survival of ARRH in revision THA is included in the study.

    METHODS: Retrospective review of 48 patients (48 hips) with follow-up duration of average 11.4 years (range, 6.1-21.4 years) was conducted. At each follow-up, Harris hip score was used to assess functional outcome, and radiographic acetabular component osteolysis was measured by DeLee and Charnley classification. Bone defects were assessed preoperatively and intraoperatively using American academy of orthopedic surgeons and Paprosky classification. The common modes of ARRH failures were evaluated. Bone consolidation, presence of heterotopic ossification, and complications such as infection and dislocation were recorded.

    RESULTS: The bone defects were varied and included cavitary, segmental, and combined defects without any pelvic discontinuity. Mean Harris hip score improved from 52.6 points preoperatively to 82.0 points postoperatively. Nine acetabular revisions and 3 stem revisions (2 concurrent with acetabular revisions and 1 isolated stem revision) were performed. There were 5 infected cases and 1 patient with recurrent dislocation. The 11.4-year survival of revision THA with ARRH was 71% as the end point for acetabular revision surgery for any reason. The expected 15-year survival of revision THA with ARRH was 60%. The most common failure mode of ARRH was superomedial migration followed by lateral migration.

    CONCLUSION: ARRH combined with bone grafting produces relatively good average long-term clinical results.

    Matched MeSH terms: Hip Prosthesis/statistics & numerical data*
  7. Park KS, Chan CK, Lee DH, Yoon TR
    Indian J Orthop, 2018 8 7;52(4):369-373.
    PMID: 30078894 DOI: 10.4103/ortho.IJOrtho_494_16
    Background: Conversion from failed bipolar hemiarthroplasty (HA) to total hip arthroplasty (THA) presents a great challenge to orthopedic surgeons for bipolar head removal and cup placement with or without change of femoral stem. Conversion THA after failed bipolar arthroplasty is known to offer both symptomatic and functional improvement. This study evaluates the midterm functional outcome and complications, especially dislocation associated with femoral head diameter, after conversion THA.

    Materials and Methods: Forty eight hips with the conversion of bipolar HA to THA were followed up for an average 6.2 years (range 2.0-11.5 years). Twenty one hips had conversion surgery to THA using metal-on-metal articulation (28 or 32 mm head). Nine hips used ceramic-on-ceramic (28-40 mm) and eighteen hips used large head metal-on-metal bearing (>40 mm). Outcome was evaluated using Harris Hip Score (HHS) and Western Ontario McMaster Universities Osteoarthritis Index (WOMAC) score. The radiographs were analyzed for evidence of osteolysis and/or loosening. The complications were evaluated, especially dislocation with different femoral head diameter.

    Results: Average HHS significantly improved from 42 preoperatively to 86 postoperatively and the average WOMAC score also significantly improved from 47 to 22 postoperatively. Radiological evaluation showed all the femoral components were stable. There was one acetabular component loosening, which required revision 9 years after conversion to THA. One dislocation and one recurrent dislocation were recorded in isolated acetabular revision hip; whereas one dislocation, one recurrent dislocation, and one trochanteric nonunion occurred in the hips with revision of both components. All dislocations occurred in hips with a femoral head size of 28 mm (P = 0.052). The cup and femoral head interval length was the most significant factor contributing to dislocation (P = 0.013).

    Conclusions: Conversion THA after failed bipolar HA offers a reliable pain relief and functional improvement. To prevent dislocation, it is highly recommended to use a larger diameter femoral head, especially where the cup size is big.

    Matched MeSH terms: Hip Prosthesis
  8. Harjeet, S., Suhail, A., Shahril, Y., Masbah, O., Subanesh, S.
    Malays Orthop J, 2009;3(1):24-27.
    MyJurnal
    Fracture of the femoral neck is one of the most common types of osteoporotic fractures. Hemiarthroplasty continues to be a good option despite current calls for total hip arthroplasty in this subset of patients. The hemiarthroplasty is less expensive and easier to perform, and can be adequately carried out in smaller hospitals with basic orthopaedic facilities staffed by general orthopaedists. Functional demands of the elderly among Asians are often less compared to similar subsets of Western population on which most comparative hip studies are based. This study was undertaken to investigate the outcome for femoral neck fractures treated with conventional hemiarthroplasty. The authors hope to provide information based on local data as a reference for our doctors and patients.
    Matched MeSH terms: Hip Prosthesis
  9. Abbas AA, Kim YJ, Song EK, Yoon TR
    J Arthroplasty, 2009 Oct;24(7):1144.e5-8.
    PMID: 18848418 DOI: 10.1016/j.arth.2008.09.008
    The causes of groin pain after total hip arthroplasty are numerous, and the condition itself is disabling. Therefore, it is imperative that the cause of the pain is identified and managed appropriately. We report a case where the patient had groin pain after total hip arthroplasty as a result of an oversized cementless acetabular component, which caused a breach in the anterior wall of the acetabulum. The anterior wall of the acetabulum was reconstructed with femoral head allograft, and the patient has been symptom free since.
    Matched MeSH terms: Hip Prosthesis*
  10. Mohamad JA, Kwan MK, Merican AM, Abbas AA, Kamari ZH, Hisa MK, et al.
    Med J Malaysia, 2004 Dec;59 Suppl F:3-7.
    PMID: 15941153
    We report our early experience of 20 cases of metal on metal articulation total hip arthroplasty in 19 young patients. Avascular necrosis of the femoral head (63%) was the commonest diagnosis for patients undergoing this procedure, followed by osteoarthritis (21%). In general, most of the patients were young and physically active with an average age of 43.1 years (range, 25 to 58 years). The average follow-up period was 18 months (range, 7 to 46 months). The mean total Harris Hip Score preoperatively and at final follow-up was 31 points and 89 points respectively. The mean total Pain Score improved from an average of 11.5 to 41.1 points at final follow-up. Sixteen (84%) of the patients had a good to excellent hip score. There was one dislocation, which stabilized after reduction and conservative management. One case of early infection underwent a two-staged revision.
    Matched MeSH terms: Hip Prosthesis*
  11. Dhillon KS, Askander A, Doraismay S
    J Bone Joint Surg Br, 1996 May;78(3):427-30.
    PMID: 8636180
    Postoperative deep-vein thrombosis (DVT) is believed to be rare in Asians. We studied 88 consecutive patients in Malaysia who had operations for fracture of the proximal femur or for total hip or knee replacement. No patient had prophylaxis against DVT; bilateral ascending venography was performed between six and ten days after operation. A total of 55 patients (62.5%) showed venographic evidence of DVT. The prevalence was greatest after total knee replacement (76.5%), less after total hip replacement (64.3%) and smallest in the fracture group (50%). One patient developed symptomatic pulmonary embolism. In contrast to other reports from Asia, we found an incidence of postoperative DVT which is similar to that reported in Western populations. This suggests that the present practice of withholding routine prophylaxis against thromboembolism in Asian patients undergoing high-risk orthopaedic procedures should be reconsidered.
    Matched MeSH terms: Hip Prosthesis/adverse effects*
  12. Park KS, Chan CK, Kim SK, Li QS, Im CJ, Yoon TR
    J Orthop Sci, 2019 May;24(3):452-457.
    PMID: 30415823 DOI: 10.1016/j.jos.2018.10.016
    BACKGROUND: Due to concern of potential metallosis caused by residual microscopic ceramic particles, metal-on-metal (MoM) bearing is deemed undesirable in revision total hip arthroplasty (THA) for ceramic bearing fracture. We determined whether MoM bearing is suitable to be used in revision THA for ceramic fractures and also evaluated whether this treatment increases serum iron levels compared with MoM bearing revision THA for polyethylene failure.

    METHODS: Between 2006 and 2012, 22 patients underwent revision surgery using MoM bearing (28 mm femoral head in 18 hips and 32 mm in 4 hips) for ceramic bearing fracture and followed average 52.1 months. We assessed radiological parameter and functional outcome using Harris hip score (HHS) and WOMAC score. Also, serum cobalt (Co) and chromium (Cr) blood tests were performed and compared with the result obtained from age, sex- and follow-up duration-matched patients with MoM revision THA for failed polyethylene bearing.

    RESULTS: The mean HHS improved from 60.6 preoperatively to 90.3 at final follow-up. There were no changes in cup position, progression of osteolytic lesions, and measurable wear of MoM bearing articulation at final follow-up radiographs. There was one case of recurrent dislocation after surgery, which was treated with greater trochanter distal advancement and one case of deep infection, which underwent two-stage revision. Mean serum Co level (1.7 vs. 1.4 μg/dl; p = 0.211) and Cr level (0.70 vs. 1.01 μg/dl; p = 0.327) showed no significant difference.

    CONCLUSIONS: MoM articulation with liner cementation into the acetabular cup along with total synovectomy can be chosen in revision surgery for ceramic fracture with good midterm follow-up. However, the use of MoM bearing is indicated when the stem and metal shell can be retained and ceramic on ceramic or ceramic on polyethylene bearing cannot be selected. Also long-term outcome needs to be further evaluated.

    Matched MeSH terms: Hip Prosthesis*
  13. Baharuddin MY, Salleh ShH, Hamedi M, Zulkifly AH, Lee MH, Mohd Noor A, et al.
    Biomed Res Int, 2014;2014:478248.
    PMID: 24800230 DOI: 10.1155/2014/478248
    Stress shielding and micromotion are two major issues which determine the success of newly designed cementless femoral stems. The correlation of experimental validation with finite element analysis (FEA) is commonly used to evaluate the stress distribution and fixation stability of the stem within the femoral canal. This paper focused on the applications of feature extraction and pattern recognition using support vector machine (SVM) to determine the primary stability of the implant. We measured strain with triaxial rosette at the metaphyseal region and micromotion with linear variable direct transducer proximally and distally using composite femora. The root mean squares technique is used to feed the classifier which provides maximum likelihood estimation of amplitude, and radial basis function is used as the kernel parameter which mapped the datasets into separable hyperplanes. The results showed 100% pattern recognition accuracy using SVM for both strain and micromotion. This indicates that DSP could be applied in determining the femoral stem primary stability with high pattern recognition accuracy in biomechanical testing.
    Matched MeSH terms: Hip Prosthesis*
  14. Baharuddin MY, Salleh ShH, Zulkifly AH, Lee MH, Noor AM, A Harris AR, et al.
    PMID: 24484753 DOI: 10.1186/1471-2474-15-30
    Minimal available information concerning hip morphology is the motivation for several researchers to study the difference between Asian and Western populations. Current use of a universal hip stem of variable size is not the best option for all femur types. This present study proposed a new design process of the cementless femoral stem using a three dimensional model which provided more information and accurate analysis compared to conventional methods.
    Matched MeSH terms: Hip Prosthesis*
  15. Arif M, Sivananthan S, Choon DS
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):25-30.
    PMID: 15237118
    To report the outcome of revised total hip arthroplasty procedures involving an anterior cortical window, extensive strut allografts, and an Exeter impaction graft.
    Matched MeSH terms: Hip Prosthesis*
  16. Sivananthan S, Arif M, Choon DS
    J Orthop Surg (Hong Kong), 2003 Dec;11(2):148-53.
    PMID: 14676339
    To evaluate the clinical and radiological outcome in patients undergoing small stem Exeter total hip replacement.
    Matched MeSH terms: Hip Prosthesis
  17. Gema A, Irianto KA, Setiawati R
    Malays Orthop J, 2021 Mar;15(1):63-71.
    PMID: 33880150 DOI: 10.5704/MOJ.2103.010
    Introduction: Early femoral stem subsidence has been a concern as a predictor of the beginning of implant loosening, especially on cementless hip arthroplasty implants. This study aimed to determine the factors that affect femoral stem subsidence and outcome following hemiarthroplasty in the geriatric population.

    Materials and Methods: This is a retrospective study of 179 patients who underwent cementless bipolar hemiarthroplasty during the 2011-2019 period at an orthopaedic and traumatology hospital. Data on the patient's demography, pre-operative American Society Anaesthesiologist (ASA) score, body mass index (BMI), canal flare index (CFI), Dorr classification, and stem alignment were obtained. The primary outcomes were post-operative femoral stem subsidence, post-operative pain, and functional outcome using Harris Hip Score (HHS). Statistical analysis was conducted to identify risk factors associated with the primary outcome.

    Results: The mean femoral stem subsidence was 2.16 ±3.4 mm. The mean post-operative Visual Analog Score (VAS) on follow-up was 1.38 ± 1. Mean HHS on follow-up was 85.28±10.3. American Society Anaesthesiologist score 3 (p = 0.011, OR = 2.77) and varus alignment (p=0.039, OR = 6.963) were related to worse stem subsidence. Otherwise, neutral alignment (p = 0.045 and OR = 0.405) gave protection against femoral stem subsidence. The female gender (p = 0.014, OR 2.53) was associated with postoperative pain onset. Neutral alignment had significant relationship with functional outcomes (p = 0.01; OR 0.33).

    Conclusion: A higher ASA score and varus stem alignment were related to a higher risk of femoral stem subsidence. Meanwhile, neutral stem alignment had a protective effect on the femoral stem subsidence and outcome.

    Matched MeSH terms: Hip Prosthesis
  18. Lim CY, Mat-Hassan S, Awang M, Md-Ariff MF, Hau-Abdullah MA
    Malays Orthop J, 2019 Nov;13(3):21-27.
    PMID: 31890106 DOI: 10.5704/MOJ.1911.004
    Introduction: Proximal femur resection and endoprosthetic reconstruction is the preferred treatment for extensive bony destruction and pathological fractures. Due to the relatively high cost of endoprosthesis, we adopted the modified unipolar hemiarthroplasty (MUH) for reconstruction when the mode of treatment was for palliation. Materials and Methods: This is a retrospective case study of six patients, who had bone and multi-organs metastases with extensive proximal femur involvement with pathologic fractures who underwent resection and MUH reconstruction during the period 2013 to 2017. All patients were classified as Group B / C based on Scandinavian Sarcoma Group survival scoring, with estimated survival of maximum six months. The basic MUH construct consisted of Austin-Moore prosthesis which was secured to a Küntscher nail using cerclage wire and cemented into the femoral canal. Subsequently, the whole length of the prosthesis which remained outside the canal was coated with cement. Results: The mean age was 61.8 years. The mean survival was 3.9 months, post-operation. There was no implant failure during patients' life span; however, a third of the patients developed infection. Wheel chair ambulation was started immediately post-operation for all patients, and two patients progressed to walking frame ambulation. The total cost of each construct was below US$490 in comparison to long-stem hemiarthroplasty (roughly US$ 1700). Conclusion: Our aim was to alleviate pain, facilitate rehabilitation, ease nursing care and improve quality of life for metastatic bone disease patients until end of life. MUH for the treatment of pathological fracture in proximal femoral metastases is a feasible palliative surgical modality in resource-limited settings.
    Matched MeSH terms: Hip Prosthesis
  19. Baharuddin MY, Salleh ShH, Zulkifly AH, Lee MH, Mohd Noor A
    Biomed Res Int, 2014;2014:692328.
    PMID: 25025068 DOI: 10.1155/2014/692328
    A morphology study was essential to the development of the cementless femoral stem because accurate dimensions for both the periosteal and endosteal canal ensure primary fixation stability for the stem, bone interface, and prevent stress shielding at the calcar region. This paper focused on a three-dimensional femoral model for Asian patients that applied preoperative planning and femoral stem design. We measured various femoral parameters such as the femoral head offset, collodiaphyseal angle, bowing angle, anteversion, and medullary canal diameters from the osteotomy level to 150 mm below the osteotomy level to determine the position of the isthmus. Other indices and ratios for the endosteal canal, metaphyseal, and flares were computed and examined. The results showed that Asian femurs are smaller than Western femurs, except in the metaphyseal region. The canal flare index (CFI) was poorly correlated (r < 0.50) to the metaphyseal canal flare index (MCFI), but correlated well (r = 0.66) with the corticomedullary index (CMI). The diversity of the femoral size, particularly in the metaphyseal region, allows for proper femoral stem design for Asian patients, improves osseointegration, and prolongs the life of the implant.
    Matched MeSH terms: Hip Prosthesis