METHODS: RNA was extracted from nasopharyngeal swab samples by a simple RNA extraction method.
RESULTS: Testing of 77 samples demonstrated 91.2% sensitivity (95% confidence interval [CI]: 78-98.2%) and 100% specificity (95% confidence interval: 92-100%) using UDG RT-LAMP.
CONCLUSION: This colorimetric UDG RT-LAMP is a simple-to-use, fast, and easy-to-interpret method, which could serve as an alternative for diagnosis of SARS-CoV-2 infection, especially in remote hospitals and laboratories with under-equipped medical facilities.
OBJECTIVE: To evaluate the initial staging discrepancy between conventional contrasted computed tomography (CT) and 18F-fluorodeoxy-D-glucose positron emission tomography/computed tomography (18F-FDG PET/CT) and its impact on management plans for head and neck malignancies.
DESIGN AND SETTING: Prospective cross-sectional study in two tertiary-level hospitals.
METHODS: This study included 30 patients with primary head and neck malignant tumors who underwent contrasted computed tomography and whole-body 18F-FDG PET/CT assessments. The staging and treatment plans were compared with the incremental information obtained after 18F-FDG PET/CT.
RESULTS: 18F-FDG PET/CT was found to raise the stage in 33.3% of the cases and the treatment intent was altered in 43.3% of them, while there was no management change in the remaining 56.7%. 18F-FDG PET/CT had higher sensitivity (96% versus 89.2%) and accuracy (93% versus 86.7%) than conventional contrast-enhanced computed tomography.
CONCLUSION: Our study demonstrated that 18F-FDG PET/CT had higher sensitivity and accuracy for detecting head and neck malignancy, in comparison with conventional contrast-enhanced computed tomography. 18F-FDG PET/CT improved the initial staging and substantially impacted the management strategy for head and neck malignancies.
METHODS: In this systematic review and individual participant data meta-analysis, we updated a search of PubMed (MEDLINE), Embase, the Cochrane Library, and conference abstracts for publications from Jan 1, 2011, to March 12, 2018, done in a previous systematic review to include the period up to Aug 2, 2019. We screened the reference lists of identified pieces and contacted experts in the field. We included prospective cross-sectional, observational studies and randomised trials among adult and adolescent (age ≥10 years) ambulatory people living with HIV, irrespective of signs and symptoms of tuberculosis. We extracted study-level data using a standardised data extraction form, and we requested individual participant data from study authors. We aimed to compare the W4SS with alternative screening tests and strategies and the WHO-recommended algorithm (ie, W4SS followed by Xpert) with Xpert for all in terms of diagnostic accuracy (sensitivity and specificity), overall and in key subgroups (eg, by antiretroviral therapy [ART] status). The reference standard was culture. This study is registered with PROSPERO, CRD42020155895.
FINDINGS: We identified 25 studies, and obtained data from 22 studies (including 15 666 participants; 4347 [27·7%] of 15 663 participants with data were on ART). W4SS sensitivity was 82% (95% CI 72-89) and specificity was 42% (29-57). C-reactive protein (≥10 mg/L) had similar sensitivity to (77% [61-88]), but higher specificity (74% [61-83]; n=3571) than, W4SS. Cough (lasting ≥2 weeks), haemoglobin (<10 g/dL), body-mass index (<18·5 kg/m2), and lymphadenopathy had high specificities (80-90%) but low sensitivities (29-43%). The WHO-recommended algorithm had a sensitivity of 58% (50-66) and a specificity of 99% (98-100); Xpert for all had a sensitivity of 68% (57-76) and a specificity of 99% (98-99). In the one study that assessed both, the sensitivity of sputum Xpert Ultra was higher than sputum Xpert (73% [62-81] vs 57% [47-67]) and specificities were similar (98% [96-98] vs 99% [98-100]). Among outpatients on ART (4309 [99·1%] of 4347 people on ART), W4SS sensitivity was 53% (35-71) and specificity was 71% (51-85). In this population, a parallel strategy (two tests done at the same time) of W4SS with any chest x-ray abnormality had higher sensitivity (89% [70-97]) and lower specificity (33% [17-54]; n=2670) than W4SS alone; at a tuberculosis prevalence of 5%, this strategy would require 379 more rapid diagnostic tests per 1000 people living with HIV than W4SS but detect 18 more tuberculosis cases. Among outpatients not on ART (11 160 [71·8%] of 15 541 outpatients), W4SS sensitivity was 85% (76-91) and specificity was 37% (25-51). C-reactive protein (≥10 mg/L) alone had a similar sensitivity to (83% [79-86]), but higher specificity (67% [60-73]; n=3187) than, W4SS and a sequential strategy (both test positive) of W4SS then C-reactive protein (≥5 mg/L) had a similar sensitivity to (84% [75-90]), but higher specificity than (64% [57-71]; n=3187), W4SS alone; at 10% tuberculosis prevalence, these strategies would require 272 and 244 fewer rapid diagnostic tests per 1000 people living with HIV than W4SS but miss two and one more tuberculosis cases, respectively.
INTERPRETATION: C-reactive protein reduces the need for further rapid diagnostic tests without compromising sensitivity and has been included in the updated WHO tuberculosis screening guidelines. However, C-reactive protein data were scarce for outpatients on ART, necessitating future research regarding the utility of C-reactive protein in this group. Chest x-ray can be useful in outpatients on ART when combined with W4SS. The WHO-recommended algorithm has suboptimal sensitivity; Xpert for all offers slight sensitivity gains and would have major resource implications.
FUNDING: World Health Organization.
METHODS: This was a meta-analysis of diagnostic test accuracy. Relevant studies that evaluated the diagnostic performance of RDTs and microscopy for detection of asymptomatic malaria were searched in health-related electronic databases. The methodological quality of the studies included was assessed using the QUADAS-2 tool.
RESULTS: Ten studies assessing RDT and/or microscopy were identified. The diagnostic accuracies in all these studies were verified by PCR. Overall, the pooled sensitivities of RDT, as well as microscopy for detection of any malaria parasites in asymptomatic participants, were low, while their pooled specificities were almost ideal. For the detection of Plasmodium falciparum, pooled sensitivity by RDT (59%, 95%CI:16-91%) or microscopy (55%, 95%CI: 25-82%) were almost comparable. For detection of Plasmodium vivax, pooled sensitivity of RDT (51%, 95% CI:7-94%) had also the comparable accuracy of microscopy (54%, 95%CI,11-92%). Of note are the wide range of sensitivity and specificity.
CONCLUSION: The findings of this meta-analysis suggest that RDTs and microscopy have limited sensitivity and are inappropriate for the detection of asymptomatic Plasmodium infections. Other methods including a combination of PCR-based strategies, Loop-Mediated Isothermal Amplification (LAMP) technique must be considered to target these infections, in order to achieve malaria elimination. However, more data is needed for the wide acceptance and feasibility of these approaches. Studies to explore the role of asymptomatic and sub-patent infections in the transmission of malaria are of critical importance and are recommended.
RESULTS: Several reaction conditions of the LAMP reaction were optimized to ensure efficient amplification of the target DNA. The sensitivity of the developed LAMP assay obtained using a pure Leptospira culture was 2 × 104 copies of genomic DNA per reaction (equivalent to 0.1 ng) for a 40-minute reaction time. No cross-reactions were observed in the LAMP reaction against a series of non-leptospiral bacteria, indicating a specific reaction. The applicability of the LAMP assay was demonstrated on human blood and urine specimens collected from suspected leptospirosis patients and rat kidney specimens collected from suspected leptospirosis outbreak areas and high-risk areas. The developed LAMP assay demonstrated a higher detection rate for leptospiral DNA compared with the polymerase chain reaction (PCR) assay, possibly due to the presence of inhibitory substances, especially in rat kidney specimens, to which the PCR method is more susceptible. The present findings also highlight the importance of urine sample collection from patients for routine monitoring of the disease.
CONCLUSIONS: In short, the developed LAMP assay can serve as a feasible alternative tool for the diagnosis of leptospirosis and be used for epidemiological and environmental surveillance of the disease, considering its robustness, rapidity, sensitivity, and specificity, as demonstrated in this study.
METHODS: Ten RDTs were evaluated: nine to detect clinical P. knowlesi infections from Malaysia, and nine assessing limit of detection (LoD) for P. knowlesi (PkA1-H.1) and P. falciparum (Pf3D7) cultures. Targets included Plasmodium-genus parasite lactate dehydrogenase (pan-pLDH) and P. vivax (Pv)-pLDH.
RESULTS: Samples were collected prior to antimalarial treatment from 127 patients with microscopy-positive PCR-confirmed P. knowlesi mono-infections. Median parasitaemia was 788/µL (IQR 247-5,565/µL). Pan-pLDH sensitivities ranged from 50.6% (95% CI 39.6-61.5) (SD BIOLINE) to 87.0% (95% CI 75.1-94.6) (First Response® and CareStart™ PAN) compared to reference PCR. Pv-pLDH RDTs detected P. knowlesi with up to 92.0% (95% CI 84.3-96.7%) sensitivity (Biocredit™). For parasite counts ≥200/µL, pan-pLDH (Standard Q) and Pv-pLDH RDTs exceeded 95% sensitivity. Specificity of RDTs against 26 PCR-confirmed negative controls was 100%. Sensitivity of six highest performing RDTs were not significantly different when comparing samples taken before and after (median 3 hours) antimalarial treatment. Parasite ring stages were present in 30% of pre-treatment samples, with ring stage proportions (mean 1.9%) demonstrating inverse correlation with test positivity of Biocredit™ and two CareStart™ RDTs.For cultured P. knowlesi, CareStart™ PAN demonstrated the lowest LoD at 25 parasites/µL; LoDs of other pan-pLDH ranged from 98 to >2000 parasites/µL. Pv-pLDH LoD for P. knowlesi was 49 parasites/µL. No false-positive results were observed in either P. falciparum-pLDH or histidine-rich-protein-2 channels.
CONCLUSION: Selected RDTs demonstrate sufficient performance for detection of major human malaria species including P. knowlesi in co-endemic areas where microscopy is not available, particularly for higher parasite counts, although cannot reliably differentiate among non-falciparum malaria.
METHODS: In the current project, we have described two extraction-free reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays for the detection of SARS-CoV-2 by using E gene and RdRp gene as the targets.
RESULTS: Here, results showed that reverse transcription loop-mediated isothermal amplification assays with 88.4% sensitive (95% CI: 74.9-96.1%) and 67.4% sensitive (95% CI: 51.5-80.9%) for E gene and RdRp gene, respectively.
CONCLUSION: Without the need of RNA purification, our developed RT-LAMP assays for direct detection of SARS-CoV-2 from nasopharyngeal swab samples could be turned into alternatives to qRT-PCR for rapid screening.
METHODS AND RESULTS: Comparisons were made for Anyplex28 genotyping from 115 cervical samples extracted on the Hamilton, STARlet and the MP96. Two DNA concentrations were used for the MP96, one matched for sample input to the STARlet and another 5× concentration (laboratory standard). Agreement of HPV detection was 89·8% (κ = 0·798; P = 0·007), with HPV detected in 10 more samples for the MP96. There was a high concordance of detection for any oncogenic HPV genotype (κ = 0·77; P = 0·007) and for any low-risk HPV genotype (κ = 0·85; P = 0·008). DNA extracted at laboratory standard had a lower overall agreement 85·2% (κ = 0·708; P