Displaying publications 21 - 40 of 285 in total

Abstract:
Sort:
  1. Balasubramanian N, Kojima T, Basha CA, Srinivasakannan C
    J Hazard Mater, 2009 Aug 15;167(1-3):966-9.
    PMID: 19231076 DOI: 10.1016/j.jhazmat.2009.01.081
    Removal of arsenic from aqueous solution was carried out using electrocoagulation. Experiments were conducted using mild steel sacrificial anode covering wide range in operating conditions to assess the removal efficiency. The maximum arsenic removal efficiency was recorded as 94% under optimum condition. The electrocoagulation mechanism of arsenic removal has been developed to understand the effect of applied charge and electrolyte pH on arsenic removal efficiency. Further the experimental data were tested with different adsorption isotherm model to describe the electrocoagulation process.
    Matched MeSH terms: Water Purification/methods
  2. Hameed BH, Lee TW
    J Hazard Mater, 2009 May 30;164(2-3):468-72.
    PMID: 18804913 DOI: 10.1016/j.jhazmat.2008.08.018
    In this study, advanced oxidation process utilizing Fenton's reagent was investigated for degradation of malachite green (MG). The effects of different reaction parameters such as the initial MG concentration, initial pH, the initial hydrogen peroxide concentration, the initial ferrous concentration and the reaction temperature on the oxidative degradation of MG have been investigated. The optimal reacting conditions were experimentally found to be pH 3.40, initial hydrogen peroxide concentration=0.50mM and initial ferrous concentration=0.10mM for initial MG concentration of 20mg/L at 30 degrees C. Under optimal conditions, 99.25% degradation efficiency of dye in aqueous solution was achieved after 60 min of reaction.
    Matched MeSH terms: Water Purification/methods*
  3. Ujang Z, Ng KS, Tg Hamzah TH, Roger P, Ismail MR, Shahabudin SM, et al.
    Water Sci Technol, 2007;56(9):103-8.
    PMID: 18025737
    A pilot scale membrane plant was constructed and monitored in Shah Alam, Malaysia for municipal wastewater reclamation for industrial application purposes. The aim of this study was to verify its suitability under the local conditions and environmental constraints for secondary wastewater reclamation. Immersed-type crossflow microfiltration (IMF) was selected as the pretreatment step before reverse osmosis filtration. Secondary wastewater after chlorine contact tank was selected as feed water. The results indicated that the membrane system is capable of producing a filtrate meeting the requirements of both WHO drinking water standards and Malaysian Effluent Standard A. With the application of an automatic backwash process, IMF performed well in hydraulic performance with low fouling rate being achieved. The investigations showed also that chemical cleaning is still needed because of some irreversible fouling by microorganisms always remains. RO treatment with IMF pretreatment process was significantly applicable for wastewater reuse purposes and promised good hydraulic performance.
    Matched MeSH terms: Water Purification/methods*
  4. Yin CY, Aroua MK, Daud WM
    Water Sci Technol, 2007;56(9):95-101.
    PMID: 18025736
    Palm shell activated carbon was modified via surface impregnation with polyethyleneimine (PEI) to enhance removal of Cu(2+) from aqueous solution in this study. The effect of PEI modification on batch adsorption of Cu(2+) as well as the equilibrium behavior of adsorption of metal ions on activated carbon were investigated. PEI modification clearly increased the Cu(2+) adsorption capacities by 68% and 75.86% for initial solution pH of 3 and 5 respectively. The adsorption data of Cu(2+) on both virgin and PEI-modified AC for both initial solution pH of 3 and 5 fitted the Langmuir and Redlich-Peterson isotherms considerably better than the Freundlich isotherm.
    Matched MeSH terms: Water Purification/methods*
  5. Vijayaraghavan K, Ahmad D, Yazid AY
    J Hazard Mater, 2008 Jan 31;150(2):351-6.
    PMID: 17543454
    A new method of Standard Malaysian Rubber (SMR) process wastewater treatment was developed based on in situ hypochlorous acid generation. The hypochlorous acid was generated in an undivided electrolytic cell consisting of two sets of graphite as anode and stainless sheets as cathode. The generated hypochlorous acid served as an oxidizing agent to destroy the organic matter present in the SMR wastewater. For an influent COD concentration of 2960 mg/L at an initial pH 4.5+/-0.1, current density 74.5 mA/cm(2), sodium chloride content 3% and electrolysis period of 75 min, resulted in the following residual values pH 7.5, COD 87 mg/L, BOD(5) 60 mg/L, TOC 65 mg/L, total chlorine 146 mg/L, turbidity 7 NTU and temperature 48 degrees C, respectively. In the case of 2% sodium chloride as an electrolyte for the above said operating condition resulted in the following values namely: pH 7.2, COD 165 mg/L, BOD(5) 105 mg/L, TOC 120 mg/L, total chlorine 120 mg/L, turbidity 27 NTU and temperature 53 degrees C, respectively. The energy requirement were found to be 30 and 46 Wh/L, while treating 24 L of SMR wastewater at 2 and 3% sodium chloride concentration at a current density 74.5 mA/cm(2). The observed energy difference was due to the improved conductivity at high sodium chloride content.
    Matched MeSH terms: Water Purification/methods*
  6. Ahmad AL, Wong SS, Teng TT, Zuhairi A
    J Hazard Mater, 2007 Jun 25;145(1-2):162-8.
    PMID: 17161910
    Coagulation-flocculation is a proven technique for the treatment of high suspended solids wastewater. In this study, the central composite face-centered design (CCFD) and response surface methodology (RSM) have been applied to optimize two most important operating variables: coagulant dosage and pH, in the coagulation-flocculation process of pulp and paper mill wastewater treatment. The treated wastewater with high total suspended solids (TSS) removal, low SVI (sludge volume index) and high water recovery are the main objectives to be achieved through the coagulation-flocculation process. The effect of interactions between coagulant dosage and pH on the TSS removal and SVI are significant, whereas there is no interaction between coagulant dosage and water recovery. Quadratic models have been developed for the response variables, i.e. TSS removal, SVI and water recovery based on the high coefficient of determination (R(2)) value of >0.99 obtained from the analysis of variances (ANOVA). The optimum conditions for coagulant dosage and pH are 1045mgL(-1) and 6.75, respectively, where 99% of TSS removal, SVI of 37mLg(-1) and 82% of water recovery can be obtained.
    Matched MeSH terms: Water Purification/methods*
  7. Aziz HA, Alias S, Adlan MN, Faridah, Asaari AH, Zahari MS
    Bioresour Technol, 2007 Jan;98(1):218-20.
    PMID: 16386895
    A study was conducted to investigate the efficiency of coagulation and flocculation processes for removing colour from a semi-aerobic landfill leachate from one of the landfill sites in Malaysia. Four types of coagulant namely aluminium (III) sulphate (alum), ferric (III) chloride, ferrous (II) sulphate and ferric (III) sulphate were studied using standard jar test apparatus. Results indicated that ferric chloride was superior to the other coagulants and removed 94% of colour at an optimum dose of 800 mg/l at pH 4. The effect of coagulant dosages on colour removal showed similar trend as for COD, turbidity and suspended solids. This suggested that colour in landfill leachate was mainly contributed by organic matters with some insoluble forms that exhibited turbidity and suspended solids readings. The results from this study suggested that ferric chloride could be a viable coagulant in managing colour problems associated with landfill leachate.
    Matched MeSH terms: Water Purification/methods*
  8. Lee CS, Chong MF, Robinson J, Binner E
    J Environ Manage, 2015 Jul 1;157:320-5.
    PMID: 25929197 DOI: 10.1016/j.jenvman.2015.04.028
    The production of natural biopolymers as flocculants for water treatment is highly desirable due to their inherent low toxicity and low environmental footprint. In this study, bio-flocculants were extracted from Hibiscus/Abelmoschus esculentus (okra) by using a water extraction method, and the extract yield and its performance in sludge dewatering were evaluated. Single factor experimental design was employed to obtain the optimum conditions for extraction temperature (25-90 °C), time (0.25-5 h), solvent loading (0.5-5 w/w) and agitation speed (0-225 rpm). Results showed that extraction yield was affected non-linearly by all experimental variables, whilst the sludge dewatering ability was only influenced by the temperature of the extraction process. The optimum extraction conditions were obtained at 70 °C, 2 h, solvent loading of 2.5 w/w and agitation at 200 rpm. Under the optimal conditions, the extract yield was 2.38%, which is comparable to the extraction of other polysaccharides (0.69-3.66%). The bio-flocculants displayed >98% removal of suspended solids and 68% water recovery during sludge dewatering, and were shown to be comparable with commercial polyacrylamide flocculants. This work shows that bio-flocculants could offer a feasible alternative to synthetic flocculants for water treatment and sludge dewatering applications, and can be extracted using only water as a solvent, minimising the environmental footprint of the extraction process.
    Matched MeSH terms: Water Purification/methods*
  9. Oon YL, Ong SA, Ho LN, Wong YS, Oon YS, Lehl HK, et al.
    Bioresour Technol, 2015 Jun;186:270-5.
    PMID: 25836035 DOI: 10.1016/j.biortech.2015.03.014
    An innovative design of upflow constructed wetland-microbial fuel cell (UFCW-MFC) planted with cattail was used for simultaneous wastewater treatment and electricity generation. The electrodes material employed in the study was carbon felt. The main aim of this study is to assess the performance of the UFCW coupling with MFC in term of ability to treat wastewater and the capability to generate bioelectricity. The oxidation reduction potential (ORP) and dissolved oxygen (DO) profile showed that the anaerobic and aerobic regions were well developed in the lower and upper bed, respectively, of UFCW-MFC. Biodegradation of organic matter, nitrification and denitrification was investigated and the removal efficiencies of COD, NO3(-), NH4(+) were 100%, 40%, and 91%, respectively. The maximum power density of 6.12 mW m(-2) and coulombic efficiency of 8.6% were achieved at electrode spacing of anode 1 (A1) and cathode (15 cm).
    Matched MeSH terms: Water Purification/methods*
  10. Tay KS, Madehi N
    Sci Total Environ, 2015 Jul 1;520:23-31.
    PMID: 25791053 DOI: 10.1016/j.scitotenv.2015.03.033
    Application of ozonation in water treatment involves complex oxidation pathways that could lead to the formation of various by-products, some of which may be harmful to living organisms. In this work, ozonation by-products of ofloxacin (OFX), a frequently detected pharmaceutical pollutant in the environment, were identified and their ecotoxicity was estimated using the Ecological Structure Activity Relationships (ECOSAR) computer program. In order to examine the role of ozone (O3) and hydroxyl radicals (∙OH) in the degradation of ofloxacin, ozonation was performed at pH2, 7 and 12. In this study, 12 new structures have been proposed for the ozonation by-products detected during the ozonation of ofloxacin. According to the identified ozonation by-products, O3 and ∙OH were found to react with ofloxacin during ozonation. The reaction between ofloxacin and O3 proceeded via hydroxylation and breakdown of heterocyclic ring with unsaturated double-bond. The reaction between ofloxacin and ·OH generated various by-products derived from the breakdown of heterocyclic ring. Ecotoxicity assessment indicated that ozonation of OFX could yield by-products of greater toxicity compared with parent compounds.
    Matched MeSH terms: Water Purification/methods*
  11. Salim MR, Othman F, Imtiaj Ali M, Patterson J, Hardy T
    Water Sci Technol, 2002;46(9):339-46.
    PMID: 12448487
    Several types of water treatment technologies including adsorption are now being used to treat polluted water. In this paper the removal of phenol by adsorption will be discussed. Activated carbons are successfully applied for purification of potable water and the removal of organic pollutants in wastwater. This paper is concerned with a low cost approach to treating waste water that is significant especially for those countries where oil palm is an available agricultural product like Malaysia, Ivory Coast, Nigeria, Thailand, Papua New Guinea. In the coastal region coconut is an available agricultural product and activated carbon prepared using coconut shell is also an economical method of water treatment. The materials used in this study were Commercial Activated Carbon (CAC), prepared from coconut shell and Modified Oil Palm Shell (MOPAS) of 1 to 2 mm diameters. The surface area of CAC and MOPAS was 38.5 m2/g and 38.2 m2/g respectively and the iodine number was determined as 674 and 454 for CAC and MOPAS, respectively. From the study the result shows above 70% removal efficiency for 5 mg/L and 40% removal efficiency for 20 mg/L of phenol solution. The performance efficiency will be discussed based on batch test, following Freundlich adsorption isotherm. The results indicate that CAC exhibits a higher adsorptive capacity (Kf of 0.079) as compared to MOPAS (Kf of 0.048). Hence a better removal efficiency for CAC at lower concentration of phenol. Results from column tests show a better adsorptive capacity for CAC (2.73) as compared to MOPAS (2.48).
    Matched MeSH terms: Water Purification/methods*
  12. Ujang Z, Salim MR, Khor SL
    Water Sci Technol, 2002;46(9):193-200.
    PMID: 12448469
    A laboratory-scale membrane bioreactor (MBR) was fed with synthetic wastewater to investigate the possibility of simultaneous removal of organic, nitrogen and phosphorus by intermittent aeration. The MBR consists of two compartments using a microfiltration membrane with 0.2 microm pore size and a surface area of 0.35 m2. Hydraulic retention time was set at 24 hours and solid retention time 25 days. MLSS concentration in the reactor was in the range of 2,500-3,800 mg/L. The MLSS internal recycling ratio was maintained at 100% influent flow rate. Intermittent aeration was applied in this study to provide an aerobic-anaerobic cycle. Three stages of operations were conducted to investigate the effect of aeration and non-aeration on simultaneous organic and nutrient removal. In Stage 1, time cycles of aeration and non-aeration were set at 90/150 min and 150/90 min in the first and second compartment, the removal efficiency was 97%, 94% and 70% for COD, nitrogen and phosphorus respectively. In Stage 2, time cycles of aeration and non-aeration were set at 60/120 min and 120/60 min in the first and second compartment, the removal efficiency was 97%, 96% and 71% for COD, nitrogen and phosphorus respectively. In Stage 3, time cycles of aeration and non-aeration were set at 120/120 min and 120/120 min in compartment 1 and 2, the removal efficiency was 98%, 96% and 78% for COD, nitrogen and phosphorus respectively. Results show that longer non-aeration time in the second compartment provided better performances of biological phosphorus removal.
    Matched MeSH terms: Water Purification/methods*
  13. Ismail R, Kassim MA, Inman M, Baharim NH, Azman S
    Water Sci Technol, 2002;46(9):179-83.
    PMID: 12448467
    Environmental monitoring was carried out at Upper Layang Reservoir situated in Masai, Johor, Malaysia. The study shows that thermal stratification and natural mixing of the water column do exist in the reservoir and the level of stratification varies at different times of the year. Artificial destratification via diffused air aeration techniques was employed at the reservoir for two months. The results show that thermal stratification was eliminated after a week of continuous aeration. The concentrations of iron and to a lesser extent manganese in the water column was also reduced during the aeration period.
    Matched MeSH terms: Water Purification/methods*
  14. Jusoh AB, Noor MJ, Plow SB
    Water Sci Technol, 2002;46(9):127-35.
    PMID: 12448461
    The removal of natural organic matter (NOM) using a continuous flow fixed bed granular activated carbon (GAC) column was studied and the results were then fitted with the Adams-Bohart, Bed-Depth-Service-Time and Clarks models. The GAC, KI-6070 and KI-8085 used in the study had external surface areas of 277 m2/g and 547 m2/g, respectively. Adsorption of NOM by the GAC was complex and involved more than one rate-limiting step. The critical bed depths for KI-6070 and KI-8085 were 0.24 m and 0.3 m, respectively. The Clark model was more effective in simulating the absorbent breakthrough process as compared to the Adams-Bohart model. The lower empty bed contact time (EBCT) i.e. 15 minutes gave a better fit to the Clark Model as compared to EBCT of 20 and 30 minutes.
    Matched MeSH terms: Water Purification/methods*
  15. Abdul-Talib S, Hvitved-Jacobsen T, Vollertsen J, Ujang Z
    Water Sci Technol, 2002;45(3):53-60.
    PMID: 11902481
    The sewer is an integral part of the urban wastewater system: the sewer, the wastewater treatment plant and the local receiving waters. The sewer is a reactor for microbial changes of the wastewater during transport, affecting the quality of the wastewater and thereby the successive treatment processes or receiving water impacts during combined sewer overflows. This paper presents the results of studies on anoxic processes, namely denitrification, in the bulk water phase of wastewater as it occurs in sewers. Experiments conducted on 12 different wastewater samples have shown that the denitrification process in the bulk wastewater can be simplified by the reduction of nitrate to nitrogen with significant accumulation of nitrite in the water phase. Utilization of nitrate was observed not to be limited by nitrate for concentrations above 5 gNO3-N/m3. The denitrification rates, under conditions of excess substrate and electron acceptor, were found to be in the range of 0.8-2.0 g NO3-N/(m3h). A discussion on the interaction of the sewer processes and the effects on a downstream located wastewater treatment plant (WWTP) is provided.
    Matched MeSH terms: Water Purification/methods*
  16. Mashitah, Zulfadhly Z, Bhatia S
    Artif Cells Blood Substit Immobil Biotechnol, 1999 Sep-Nov;27(5-6):429-33.
    PMID: 10595444
    The equilibrium sorption capacity of a macro-fungi, Pycnoporus sanguineus biomass was studied using a single-metal system comprising copper ions. The rate and extent for the removal of copper were subjected to environmental parameters such as pH, biomass loading, temperature, and contact time. Results showed that the uptake of copper increased as the pH increased. However, as the biomass loading increased, the amount of metal uptake decreased. Instead, temperature does not have a significant effect on the metal uptake, especially between 30 to 40 degrees C. A maximum adsorption of copper ions was also observed within 15 minutes of reaction time for the entire sample tested. Furthermore, pre-treatment with sodium bicarbonate and boiling water significantly improved the sorption capacity of copper by Pycnoporus sanguineus.
    Matched MeSH terms: Water Purification/methods*
  17. Wan Ngah WS, Kamari A, Koay YJ
    Int J Biol Macromol, 2004 Jun;34(3):155-61.
    PMID: 15225987
    The adsorption of Cu(II) ions from aqueous solution by chitosan and chitosan/PVA beads was studied in a batch adsorption system. Chitosan solution was blended with poly(vinyl alcohol) (PVA) in order to obtain sorbents that are insoluble in aqueous acidic and basic solution. The adsorption capacities and rates of Cu(II) ions onto chitosan and chitosan/PVA beads were evaluated. The Langmuir, Freundlich and BET adsorption models were applied to describe the isotherms and isotherm constants. Adsorption isothermal data could be well interpreted by the Langmuir model. The kinetic experimental data properly correlated with the second-order kinetic model, which indicates that the chemical sorption is the rate-limiting step. The Cu(II) ions can be removed from the chitosan and chitosan/PVA beads rapidly by treatment with an aqueous EDTA solution. Results also showed that chitosan and chitosan/PVA beads are favourable adsorbers.
    Matched MeSH terms: Water Purification/methods
  18. Khan MA, Alqadami AA, Otero M, Siddiqui MR, Alothman ZA, Alsohaimi I, et al.
    Chemosphere, 2019 Mar;218:1089-1099.
    PMID: 30609488 DOI: 10.1016/j.chemosphere.2018.11.210
    Efforts to improve water quality have led to the development of green and sustainable water treatment approaches. Herein, nitrogen-doped magnetized hydrochar (mSBHC-N) was synthesized, characterized, and used for the removal of post-transition and transition heavy metals, viz. Pb2+ and Cd2+ from aqueous environment. mSBHC-N was found to be mesoporous (BET surface area - 62.5 m2/g) and paramagnetic (saturation magnetization - 44 emu/g). Both, FT-IR (with peaks at 577, 1065, 1609 and 3440 cm-1 corresponding to Fe - O stretching vibrations, C - N stretching, N - H in-plane deformation and stretching) and XPS analyses (with peaks at 284.4, 400, 530, 710 eV due to C 1s, N 1s, O 1s, and Fe 2p) confirmed the presence of oxygen and nitrogen containing functional groups on mSBHC-N. The adsorption of Pb2+ and Cd2+ was governed by oxygen and nitrogen functionalities through electrostatic and co-ordination forces. 75-80% of Pb2+ and Cd2+ adsorption at Co: 25 mg/L, either from deionized water or humic acid solution was accomplished within 15 min. The data was fitted to pseudo-second-order kinetic and Langmuir isotherm models, with maximum monolayer adsorption capacities being 323 and 357 mg/g for Cd2+and Pb2+ at 318 K, respectively. Maximum Cd2+ (82.6%) and Pb2+ (78.7%) were eluted with 0.01 M HCl, simultaneously allowing minimum iron leaching (2.73%) from mSBHC-N. In conclusion, the study may provide a novel, economical, and clean route to utilize agro-waste, such as sugarcane bagasse (SB), for aquatic environment remediation.
    Matched MeSH terms: Water Purification/methods*
  19. Fiyadh SS, AlOmar MK, Binti Jaafar WZ, AlSaadi MA, Fayaed SS, Binti Koting S, et al.
    Int J Mol Sci, 2019 Aug 28;20(17).
    PMID: 31466219 DOI: 10.3390/ijms20174206
    Multi-walled carbon nanotubes (CNTs) functionalized with a deep eutectic solvent (DES) were utilized to remove mercury ions from water. An artificial neural network (ANN) technique was used for modelling the functionalized CNTs adsorption capacity. The amount of adsorbent dosage, contact time, mercury ions concentration and pH were varied, and the effect of parameters on the functionalized CNT adsorption capacity is observed. The (NARX) network, (FFNN) network and layer recurrent (LR) neural network were used. The model performance was compared using different indicators, including the root mean square error (RMSE), relative root mean square error (RRMSE), mean absolute percentage error (MAPE), mean square error (MSE), correlation coefficient (R2) and relative error (RE). Three kinetic models were applied to the experimental and predicted data; the pseudo second-order model was the best at describing the data. The maximum RE, R2 and MSE were 9.79%, 0.9701 and 1.15 × 10-3, respectively, for the NARX model; 15.02%, 0.9304 and 2.2 × 10-3 for the LR model; and 16.4%, 0.9313 and 2.27 × 10-3 for the FFNN model. The NARX model accurately predicted the adsorption capacity with better performance than the FFNN and LR models.
    Matched MeSH terms: Water Purification/methods*
  20. Dzinun H, Othman MHD, Ismail AF
    Chemosphere, 2019 Aug;228:241-248.
    PMID: 31035161 DOI: 10.1016/j.chemosphere.2019.04.118
    Comparison studies in suspension and hybrid photocatalytic membrane reactor (HPMR) system was investigated by using Reactive Black 5 (RB5) as target pollutant under UVA light irradiation. To achieve this aim, hybrid TiO2/clinoptilolite (TCP) photocatalyst powder was prepared by solid-state dispersion (SSD) methods and embedded at the outer layer of dual layer hollow fiber (DLHF) membranes fabricated via single step co-spinning process. TiO2 and CP photocatalyst were also used as control samples. The samples were characterized by Scanning Electron Microscopy (SEM), Energy Dispersion of X-ray (EDX), X-ray diffraction (XRD) and Brunauer-Emmett-Teller (BET) analyses. The result shows that TCP was actively functioned as photocatalyst in suspension system and 86% of RB5 photocatalytic degradation achieved within 60 min; however the additional step is required to separate the catalyst with treated water. In the HPMR system, even though the RB5 photocatalytic degradation exhibits lower efficiency however the rejection of RB5 was achieved up to 95% under UV irradiation due to the properties of photocatalytic membranes. The well dispersed of TCP at the outer layer of DLHF membrane have improved the surface affinity of DL-TCP membrane towards water, exhibit the highest pure water flux of 41.72 L/m2.h compared to DL-TiO2 membrane. In general, CP can help on improving photocatalytic activity of TiO2 in suspension, increased the RB5 removal and the permeability of DLHF membrane in HPMR system as well.
    Matched MeSH terms: Water Purification/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links