Displaying publications 21 - 40 of 54 in total

Abstract:
Sort:
  1. Tan JH, Acharya UR, Chua KC, Cheng C, Laude A
    Med Phys, 2016 May;43(5):2311.
    PMID: 27147343 DOI: 10.1118/1.4945413
    The authors propose an algorithm that automatically extracts retinal vasculature and provides a simple measure to correct the extraction. The output of the method is a network of salient points, and blood vessels are drawn by connecting the salient points using a centripetal parameterized Catmull-Rom spline.
    Matched MeSH terms: Angiography/methods*
  2. Safari MJ, Wong JH, Kadir KA, Thorpe NK, Cutajar DL, Petasecca M, et al.
    Eur Radiol, 2016 Jan;26(1):79-86.
    PMID: 26002131 DOI: 10.1007/s00330-015-3818-9
    OBJECTIVES: To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures.

    METHODS: Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures.

    RESULTS: The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R(2)) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AKL: 0.93, AKF: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions.

    CONCLUSIONS: The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose.

    KEY POINTS: Real-time patient dose monitoring helps interventionalists to monitor doses. Strong correlation was observed between kerma-area-product and measured eye doses. Radiation dose at left outer canthus was higher than at left eyelid.

    Matched MeSH terms: Cerebral Angiography/methods*
  3. Moosavi Tayebi R, Wirza R, Sulaiman PS, Dimon MZ, Khalid F, Al-Surmi A, et al.
    J Cardiothorac Surg, 2015;10:58.
    PMID: 25896185 DOI: 10.1186/s13019-015-0249-2
    Computerized tomographic angiography (3D data representing the coronary arteries) and X-ray angiography (2D X-ray image sequences providing information about coronary arteries and their stenosis) are standard and popular assessment tools utilized for medical diagnosis of coronary artery diseases. At present, the results of both modalities are individually analyzed by specialists and it is difficult for them to mentally connect the details of these two techniques. The aim of this work is to assist medical diagnosis by providing specialists with the relationship between computerized tomographic angiography and X-ray angiography.
    Matched MeSH terms: Coronary Angiography/methods*
  4. Tajfard M, Tavakoly Sany SB, Avan A, Latiff LA, Rahimi HR, Moohebati M, et al.
    J Cell Physiol, 2019 07;234(7):10289-10299.
    PMID: 30548615 DOI: 10.1002/jcp.27945
    Serum high-sensitivity C-reactive protein (hs-CRP) is predictive of coronary artery disease (CAD). The aim of this study was to examine the possible association of hs-CRP with presence and severity of CAD and traditional CAD risk factors. This case-control study was carried out on 2,346 individuals from September 2011 to May 2013. Of these 1,187 had evidence of coronary disease, and were subject to coronary angiography, and the remainder were healthy controls (n = 1,159). Characteristics were determined using standard laboratory techniques and serum Hs-CRP levels were estimated using enzyme-linked immunosorbent assay (ELISA) kits, and severity of CAD was assessed according to the score of obstruction in coronary artery. Serum hs-CRP levels were higher in those with severe coronary disease, who had stenosis ≥ 50% stenosis of at least one coronary artery (all p 
    Matched MeSH terms: Coronary Angiography/methods
  5. Lim CW, Cheng J, Tay ELT, Teo HY, Wong EPY, Yong VKY, et al.
    BMC Ophthalmol, 2018 Dec 10;18(1):315.
    PMID: 30526537 DOI: 10.1186/s12886-018-0976-y
    BACKGROUND: Despite the potential usefulness of optical coherence tomography angiography in retinal and optic disc conditions, the reliability of the imaging modality remains unclear. This study set out to measure the microvascular density of macula and optic disc by mean of optical coherence tomography angiography and report the repeatability of the vessel density measurements.

    METHODS: Cross sectional observational cohort study. Subjects with normal eyes were recruited. Two sets of optical coherence tomography angiography images of macula and optic nerve head were acquired during one visit. Novel in-house developed software was used to count the pixels in each images and to compute the microvessel density of the macula and optic disc. Data were analysed to determine the measurement repeatability.

    RESULTS: A total of 176 eyes from 88 consecutive normal subjects were recruited. For macular images, the mean vessel density at superficial retina, deep retina, outer retina and choriocapillaries segment was OD 0.113 and OS 0.111, OD 0.239 and OS 0.230, OD 0.179 and OS 0.164, OD 0.237 and OS 0.215 respectively. For optic disc images, mean vessel density at vitreoretinal interface, radial peripapillary capillary, superficial nerve head and disc segment at the level of choroid were OD 0.084 and OS 0.085, OD 0.140 and OS 0.138, OD 0.216 and OS 0.209, OD 0.227 and OS 0.236 respectively. The measurement repeatability tests showed that the coefficient of variation of macular scans, for right and left eyes, ranged from 6.4 to 31.1% and 5.3 to 59.4%. Likewise, the coefficient of variation of optic disc scans, for right and left eyes, ranged from 14.3 to 77.4% and 13.5 to 75.3%.

    CONCLUSIONS: Optical coherence tomography angiography is a useful modality to visualise the microvasculature plexus of macula and optic nerve head. The vessel density measurement of macular scan by mean of optical coherence tomography angiography demonstrated good repeatability. The optic disc scan, on the other hand, showed a higher coefficient of variation indicating a lower measurement repeatability than macular scan. Interpretation of optical coherence tomography angiography should take into account test-retest repeatability of the imaging system.

    TRIAL REGISTRATION: National Healthcare Group Domain Specific Review Board ( NHG DSRB ) Singapore. DSRB Reference: 2015/00301.

    Matched MeSH terms: Fluorescein Angiography/methods
  6. Rosenberg M, Waliszewski M, Krackhardt F, Chin K, Wan Ahmad WA, Caramanno G, et al.
    J Interv Cardiol, 2019;2019:6548696.
    PMID: 31772539 DOI: 10.1155/2019/6548696
    Objectives: We analyzed the efficacy of drug coated balloons (DCB) as a stand-alone-therapy in de novo lesions of large coronary arteries. DCBs seem to be an attractive alternative for the stent-free interventional treatment of de novo coronary artery disease (CAD). However, data regarding a DCB-only approach in de novo CAD are currently limited to vessels of small caliber.

    Methods: By means of propensity score (PS) matching 234 individuals with de novo CAD were identified with similar demographic characteristics. This patient population was stratified in a 1:1 fashion according to a reference vessel diameter cut-off of 2.75 mm in small and large vessel disease. The primary endpoint was the rate of clinically driven target lesion revascularization (TLR) at 9 months.

    Results: Patients with small vessel disease had an average reference diameter of 2.45 ± 0.23 mm, while the large vessel group averaged 3.16 ± 0.27 mm. Regarding 9-month major adverse cardiac event (MACE), 5.7% of the patients with small and 6.1% of the patients with large vessels had MACE (p=0.903). Analysis of the individual MACE components revealed a TLR rate of 3.8% in small and 1.0% in large vessels (p=0.200). Of note, no thrombotic events in the DCB treated coronary segments occurred in either group during the 9-month follow-up.

    Conclusions: Our data demonstrate for the first time that DCB-only PCI of de novo lesions in large coronary arteries (>2.75 mm) is safe and as effective. Interventional treatment for CAD without permanent or temporary scaffolding, demonstrated a similar efficacy for large and small vessels.

    Matched MeSH terms: Coronary Angiography/methods
  7. Chainchel Singh MK, Abdul Rashid SN, Abdul Hamid S, Mahmood MS, Feng SS, Mohd Nawawi H, et al.
    Forensic Sci Int, 2020 Mar;308:110171.
    PMID: 32032870 DOI: 10.1016/j.forsciint.2020.110171
    BACKGROUND: Post-mortem Computed Tomography (PMCT) allows non-invasive or minimally invasive detection of findings that may or may not be visible during conventional autopsy, however, it does not allow the investigator to draw any conclusions regarding patency of the vessel's lumen. To address this deficiency, Post-mortem Computed Tomography Angiography (PMCTA) utilizing different contrast media and techniques have been introduced with various studies looking at the correlation between PMCTA, autopsy (gross) findings and coronary artery histology in diagnosing coronary artery disease.

    OBJECTIVES: The aim of this study is to investigate the sensitivity and specificity of PMCTA in diagnosing coronary artery stenosis using water-based contrast media introduced though the vessels of the neck, compared to the gold standard of diagnosis i.e. gross and histological evaluation of the coronary artery.

    METHOD: This was a cross sectional study of 158 arterial sections involving 37 subjects recruited from the National Institute of Forensic Medicine (IPFN), Hospital Kuala Lumpur (HKL). An unenhanced PMCT was performed followed by PMCTA using water-based contrast media introduced though the vessels of the neck. Coronary artery stenosis was determined using multiplanar reconstructionD while the degree of stenosis was determined by calculating the percentage of luminal diameter divided by the diameter of the vessel internal elastic.

    RESULTS: The analysis of PMCTA and histopathology examinations revealed a sensitivity of 61.5%, specificity of 91.7%; positive predictive value (PPV) of 40.0% and negative predictive value (NPV) of 96.4%.

    CONCLUSION: PMCTA utilizing water-based contrast introduced though the vessels of the neck yielded similar results as other methods and techniques of PMCTA. We would therefore conclude that PMCTA utilizing this technique could be used to assess the degree of calcification and the presence of significant stenosis.

    Matched MeSH terms: Computed Tomography Angiography/methods*
  8. Harun HH, Karim MKA, Abbas Z, Sabarudin A, Muniandy SC, Ibahim MJ
    J Xray Sci Technol, 2020;28(5):893-903.
    PMID: 32741801 DOI: 10.3233/XST-200699
    PURPOSE: To evaluate the influence of iterative reconstruction (IR) levels on Computed Tomography (CT) image quality and to establish Figure of Merit (FOM) value for CT Pulmonary Angiography (CTPA) examinations.

    METHODS: Images of 31 adult patients who underwent CTPA examinations in our institution from March to April 2019 were retrospectively collected. Other data, such as scanning parameters, radiation dose and body habitus information from the subjects were also recorded. Six different levels of IR were applied to the volume data of the subjects. Five circles of the region of interest (ROI) were drawn in five different arteries namely, pulmonary trunk, right pulmonary artery, left pulmonary artery, ascending aorta and descending aorta. The mean Signal-to-noise ratio (SNR) was obtained, and the FOM was calculated in a fraction of the SNR2 divided by volume-weighted CT dose index (CTDIvol) and SNR2 divided by the size-specific dose estimates (SSDE).

    RESULTS: Overall, we observed that the mean value of CTDIvol and SSDE were 13.79±7.72 mGy and 17.25±8.92 mGy, respectively. Notably, SNR values significantly increase with increase of the IR level (p 

    Matched MeSH terms: Computed Tomography Angiography/methods*
  9. Xie CB, Chan MY, Teo SG, Low AF, Tan HC, Lee CH
    Singapore Med J, 2011 Nov;52(11):835-9.
    PMID: 22173254
    There is a paucity of data on acute myocardial infarction (AMI) in young Asian women and of comparative data among various ethnic groups with respect to risk factor profile and clinical outcomes. We present a comprehensive overview of the clinical characteristics of young Asian women with AMI and a comparative analysis among Chinese, Malay and Indian women in a multi-ethnic Asian country.
    Matched MeSH terms: Coronary Angiography/methods
  10. Ramli N, Rahmat K, Tan GP
    Singapore Med J, 2008 Jul;49(7):e175-7.
    PMID: 18695851
    Malignant osteopetrosis is associated with petrous carotid canal and internal carotid artery stenosis in the skull base. We present a four-year-old boy with malignant osteopetrosis who developed right frontal lobe infarction as a result of bilateral internal carotid artery hypotrophy.
    Matched MeSH terms: Cerebral Angiography/methods
  11. Ong TK, Chin SP, Liew CK, Chan WL, Seyfarth MT, Liew HB, et al.
    Am Heart J, 2006 Jun;151(6):1323.e1-6.
    PMID: 16781246
    The new 64-row multidetector computed tomography (CT)-assisted angiography can now detect coronary artery disease with shorter breath-hold time and at faster heart rates for symptomatic patients. We aim to determine if the 64-row scanner can also overcome limitations due to mild to moderate calcification.
    Matched MeSH terms: Coronary Angiography/methods*
  12. Dk Yeak R, Liew SK
    Acta Orthop Traumatol Turc, 2020 Jul;54(4):465-468.
    PMID: 32812879 DOI: 10.5152/j.aott.2020.20035
    We present a rare case of a patient with concurrent fat embolism and pulmonary embolism, in a closed femur fracture with patent foramen ovale (PFO). A 24-year-old man was involved in a motor vehicle accident with a closed left midshaft femur fracture. He developed fat embolism syndrome (FES) on day 3 of admission, and plating was performed. The D-dimer concentration was also high, which raised the suspicion of pulmonary artery embolism. Computed tomography pulmonary angiography (CTPA) revealed right inferior lobar pulmonary artery embolism and FES. A transthoracic echocardiogram (TEE) was performed, which showed a PFO. The presence of a PFO in patients with pulmonary embolism increases the risk of systemic embolism. Therefore, we recommend the routine echocardiogram for patients with pulmonary embolism to exclude any cardiac defect in causing right-to-left shunts, which predisposes the patient to paradoxical embolism.
    Matched MeSH terms: Computed Tomography Angiography/methods
  13. Manuel AM, Kalimuthu S, Pathmanathan SS, Narayanan P, Zainal Abidin Z, Azmi K, et al.
    Asian J Surg, 2017 Apr;40(2):158-162.
    PMID: 24210537 DOI: 10.1016/j.asjsur.2013.09.011
    Arteriovenous malformations are congenital lesions that may evolve with time and manifest in a plethora of presentations. They can occur as torrential epistaxis when it extensively involves the facial region. Multi-imaging modalities are available to assist in characterizing the structure of the lesion as well as its location and extent. This complex disease requires a multidisciplinary team approach with preoperative embolization and surgery. We present a rare cause of life-threatening epistaxis in a gentleman with a longstanding orbital and hemifacial arteriovenous malformation and discuss the complexities involved in its management.
    Matched MeSH terms: Cerebral Angiography/methods*; Magnetic Resonance Angiography/methods
  14. Wong SC, Nawawi O, Ramli N, Abd Kadir KA
    Acad Radiol, 2012 Jun;19(6):701-7.
    PMID: 22578227 DOI: 10.1016/j.acra.2012.02.012
    The aim of this study was to compare conventional two-dimensional (2D) digital subtraction angiography (DSA) with three-dimensional (3D) rotational DSA in the investigation of intracranial aneurysm in terms of detection, size measurement, neck diameter, neck delineation, and relationship with surrounding vessels. A further aim was to compare radiation dose, contrast volume, and procedural time between the two protocols.
    Matched MeSH terms: Cerebral Angiography/methods*
  15. Govindaraju K, Badruddin IA, Viswanathan GN, Ramesh SV, Badarudin A
    Phys Med, 2013 May;29(3):225-32.
    PMID: 22704601 DOI: 10.1016/j.ejmp.2012.03.008
    Coronary Artery Disease (CAD) is responsible for most of the deaths in patients with cardiovascular diseases. Diagnostic coronary angiography analysis offers an anatomical knowledge of the severity of the stenosis. The functional or physiological significance is more valuable than the anatomical significance of CAD. Clinicians assess the functional severity of the stenosis by resorting to an invasive measurement of the pressure drop and flow. Hemodynamic parameters, such as pressure wire assessment fractional flow reserve (FFR) or Doppler wire assessment coronary flow reserve (CFR) are well-proven techniques to evaluate the physiological significance of the coronary artery stenosis in the cardiac catheterization laboratory. Between the two techniques mentioned above, the FFR is seen as a very useful index. The presence of guide wire reduces the coronary flow which causes the underestimation of pressure drop across the stenosis which leads to dilemma for the clinicians in the assessment of moderate stenosis. In such condition, the fundamental fluid mechanics is useful in the development of new functional severity parameters such as pressure drop coefficient and lesion flow coefficient. Since the flow takes place in a narrowed artery, the blood behaves as a non-Newtonian fluid. Computational fluid dynamics (CFD) allows a complete coronary flow simulation to study the relationship between the pressure and flow. This paper aims at explaining (i) diagnostic modalities for the evaluation of the CAD and valuable insights regarding FFR in the evaluation of the functional severity of the CAD (ii) the role of fluid dynamics in measuring the severity of CAD.
    Matched MeSH terms: Angiography/methods*
  16. Sabarudin A, Sun Z, Yusof AK
    Int J Cardiol, 2013 Sep 30;168(2):746-53.
    PMID: 23098849 DOI: 10.1016/j.ijcard.2012.09.217
    This study is conducted to investigate and compare image quality and radiation dose between prospective ECG-triggered and retrospective ECG-gated coronary CT angiography (CCTA) with the use of single-source CT (SSCT) and dual-source CT (DSCT).
    Matched MeSH terms: Coronary Angiography/methods
  17. Mohd Rizal MY, Kosai NR, Sutton PA, Rozman Z, Razman J, Harunarashid H, et al.
    Clin Ter, 2013;164(1):25-7.
    PMID: 23455738 DOI: 10.7417/T.2013.1506
    Dieulafoy's lesion is one of an unusual cause of upper gastrointestinal bleeding (U GIB). Endoscopic intervention has always been a preferred non-surgical method in treating UGIB including bleeding from Dieulafoy's lesion. Owing to recent advances in angiography, arterial embolization has become a popular alternative in non- variceal UGIB especially in cases with failed endoscopic treatment. However, managing bleeding Dieulafoy's with selective arterial embolization as the first line of treatment has not been exclusively practiced. We hereby, report a case of bleeding Dieulafoy lesion which had been primarily treated with arterial embolization.
    Matched MeSH terms: Angiography/methods
  18. Jung HJ, Kwon WK, Lee SJ, Mohamed N, Shin BM, Lee J, et al.
    BMC Anesthesiol, 2016 10 04;16(1):83.
    PMID: 27716083
    BACKGROUND: This study reports the efficacy of intraoperative transesophageal echocardiography (TEE) for evaluation of high take-off coronary ostia and proximal coronary arterial flows as an alternative to preoperative coronary angiography.

    CASE PRESENTATION: In a 65-year old male undergoing the bicuspid aortic valve (BAV) repair and the extensive remodeling of dilated sinus and tubular junction, and preoperative coronary angiography were unsuccessfully completed due to an allergic reaction to the contrast medium. Intraoperative TEE by employing various 3-dimensional volume images of coronary ostia and Doppler tracings of the coronary arterial flows enabled a thorough pre-procedural evaluation of the high take-off coronary arteries and post-procedural evaluation by confirming the absence of any compromise in coronary arterial flow.

    CONCLUSION: In the present case, intraoperative application of various TEE imaging modalities enabled comprehensive evaluation of high-taking off coronary artery, as an alternative to preoperative coronary angiography, in a patient undergoing an extensive aortic valve and aortic root repair procedure.

    Matched MeSH terms: Coronary Angiography/methods