Displaying publications 21 - 40 of 166 in total

Abstract:
Sort:
  1. Megahed AA, Hiew MWH, Constable PD
    J. Vet. Intern. Med., 2018 Mar;32(2):846-852.
    PMID: 29424465 DOI: 10.1111/jvim.15049
    BACKGROUND: Plasma fructosamine concentration ([FRA]) is a widely used long term hyperglycemic biomarker in humans and dogs, but its clinical usefulness as a hypoglycemic biomarker in dairy cattle is uncertain.

    OBJECTIVES: To evaluate the relationship between plasma [FRA] and glucose concentration ([gluc]) as well as indices of energy balance during early lactation in dairy cattle, and to characterize the influence of plasma total protein concentration ([TP]) and albumin concentration ([albumin]) on [FRA].

    ANIMALS: Convenience sample comprising 103 periparturient Holstein-Friesian cattle.

    METHODS: Plasma [gluc], [TP], [albumin], and other clinicopathologic indices of energy status were determined periodically from Day 4 postpartum. Body condition score (BCS) was assessed, and backfat thickness (BFT) and longissimus dorsi muscle thickness (LDT) were measured ultrasonographically. Plasma [FRA] was measured at approximately 28 days postpartum. Associations between plasma [FRA] and study variables were evaluated using Spearman's rho and stepwise forward linear regression. Statistical significance was declared at P 

    Matched MeSH terms: Blood Glucose/analysis
  2. Iwani NA, Jalaludin MY, Zin RM, Fuziah MZ, Hong JY, Abqariyah Y, et al.
    Sci Rep, 2017 Jan 06;7:40055.
    PMID: 28059134 DOI: 10.1038/srep40055
    The purpose of this study was to investigate the usefulness of triglyceride to hdl-c ratio (TG:HDL-C) as an insulin resistance (IR) marker for overweight and obese children. A total of 271 blood samples of obese and overweight children aged 9-16 years were analysed for fasting glucose, lipids and insulin. Children were divided into IR and non-insulin resistance, using homeostasis model assessment (HOMA). The children were then stratified by tertiles of TG: HDL-C ratio. The strength between TG:HDL-C ratio and other parameters of IR were quantified using Pearson correlation coefficient (r). Odds ratio was estimated using multiple logistic regression adjusted for age, gender, pubertal stages and IR potential risk factors. Children with IR had significantly higher TG:HDL-C ratio (2.48) (p = 0.01). TG:HDL-C ratio was significantly correlated with HOMA-IR (r = 0.104, p 
    Matched MeSH terms: Blood Glucose/analysis
  3. Jabbar A, Mohamed WMIBW, Ozaki R, Mirasol R, Treuer T, Lew T, et al.
    Curr Med Res Opin, 2018 09;34(9):1653-1662.
    PMID: 29863422 DOI: 10.1080/03007995.2018.1484712
    OBJECTIVE: Current and future estimates of the burden of diabetes for the Western Pacific (WP) region are among the highest in the world. Verifying Insulin Strategy and Initial Health Outcome Analysis (VISION) was an 18 month observational study that explored treatment approaches in patients with type 2 diabetes mellitus (T2DM) initiating insulin in the WP region.

    METHODS: A total of 1065 patients aged ≥18 years with T2DM initiating insulin therapy in normal clinical course were enrolled from Hong Kong, Malaysia, Philippines, Taiwan and Thailand. Participants' data was recorded by the treating physicians. Patient-reported outcomes (PROs) were assessed using questionnaires completed by participants.

    RESULTS: The mean age of patients was 57.2 years with mean glycosylated hemoglobin (HbA1c) of 10.0%. About 66% of patients had an HbA1c ≥9.0% at insulin initiation despite 74% of them being on two or more oral antidiabetic agents at the time of insulin initiation. Basal insulin was initiated in 72% and premixed insulin in 27% of patients. Changes in insulin therapy was observed in 63% of patients and, by the end of study, 28% achieved HbA1c levels of <7.5%. The proportion of patients completely satisfied with their insulin treatment increased over the study course and the quality of life (QoL) score increased from baseline to the study end.

    CONCLUSION: As high HbA1C levels indicate a delayed start of insulin therapy, timely initiation and early intensification of insulin therapy is necessary in the region to achieve adequate glycemic control in time and prevent diabetes complications. Data from PROs suggests that the insulin treatment improves QoL in most patients.

    Matched MeSH terms: Blood Glucose/analysis
  4. Omar A, Husain MN, Jamil AT, Nor NSM, Ambak R, Fazliana M, et al.
    BMC Womens Health, 2018 07 19;18(Suppl 1):103.
    PMID: 30066645 DOI: 10.1186/s12905-018-0598-9
    BACKGROUND: Regular physical activity has always been strongly recommended for good cardiovascular health. This study aimed to determine the effect of physical activity on fasting blood glucose and lipid profile among low income housewives in Klang Valley.

    METHODS: Data of 328 eligible housewives who participated in the MyBFF@Home study was used. Intervention group of 169 subjects were provided with an intervention package which includes physical activity (brisk walking, dumbbell exercise, physical activity diary, group exercise) and 159 subjects in control group received various health seminars. Physical activity level was assessed using short-International Physical Activity Questionnaire. The physical activity level was then re-categorized into 4 categories (active intervention, inactive intervention, active control and inactive control). Physical activity, blood glucose and lipid profile were measured at baseline, 3rd month and 6th month of the study. General Linear Model was used to determine the effect of physical activity on glucose and lipid profile.

    RESULTS: At the 6th month, there were 99 subjects in the intervention and 79 control group who had complete data for physical activity. There was no difference on the effect of physical activity on the glucose level and lipid profile except for the Triglycerides level. Both intervention and control groups showed reduction of physical activity level over time.

    CONCLUSION: The effect of physical activity on blood glucose and lipid profile could not be demonstrated possibly due to physical activity in both intervention and control groups showed decreasing trend over time.

    Matched MeSH terms: Blood Glucose/analysis*
  5. Yee YC, Hashim R, Mohd Yahya AR, Bustami Y
    Sensors (Basel), 2019 May 31;19(11).
    PMID: 31159318 DOI: 10.3390/s19112511
    Glucose oxidase (EC 1.1.3.4) sensors that have been developed and widely used for glucose monitoring have generally relied on electrochemical principle. In this study, the potential use of colorimetric method for glucose detection utilizing glucose oxidase-magnetic cellulose nanocrystals (CNCs) is explored. Magnetic cellulose nanocrystals (magnetic CNCs) were fabricated using iron oxide nanoparticles (IONPs) and cellulose nanocrystals (CNCs) via electrostatic self-assembly technique. Glucose oxidase was successfully immobilized on magnetic CNCs using carbodiimide-coupling reaction. About 33% of GOx was successfully attached on magnetic CNCs, and the affinity of GOx-magnetic CNCs to glucose molecules was slightly higher than free enzymes. Furthermore, immobilization does not affect the specificity of GOx-magnetic CNCs towards glucose and can detect glucose from 0.25 mM to 2.5 mM. Apart from that, GOx-magnetic CNCs stored at 4 °C for 4 weeks retained 70% of its initial activity and can be recycled for at least ten consecutive cycles.
    Matched MeSH terms: Blood Glucose/analysis
  6. Abdul Hakim BN, Yahya HM, Shahar S, Abdul Manaf Z, Damanhuri H
    PMID: 31766283 DOI: 10.3390/ijerph16224464
    Little is known about the effects of manipulating sequence of fruit consumption during a meal in suppressing an individual's appetite. Therefore, we investigate the effects of the sequence of fruit intake on satiety and blood glucose in a group of 17 healthy, young male adults. This intervention study repeatedly measured the effects of fruit intake (120 g red apple) before and after a meal and control (no fruit). Ad libitum test meal was weighed before and after a meal. Subjective appetite rating and appetite-related hormones were assessed at regular time intervals. The satiety score was significantly higher for fruit intake before a meal followed by after a meal and control (p < 0.05). Eating fruit before a meal reduced 18.5% (166 kcal) subsequent energy intake compared to control (p < 0.05). Fruit intake before a meal had a significantly higher incremental area under the curve (iAUC) of Glucagon-like peptide 1 (GLP-1), compared to after a meal (p < 0.05). There were no differences in plasma changes of ghrelin, Cholecystokinin 8 (CCK8), or blood glucose in all sessions. Consuming fruit before a meal potentially enhanced satiety. Further research is required to confirm both short- and long-term effects of the sequence of fruit intake on appetite regulation in a wider population.
    Matched MeSH terms: Blood Glucose/analysis
  7. Sukarna N, Tan PC, Hong JGS, Sulaiman S, Omar SZ
    Arch Gynecol Obstet, 2021 08;304(2):345-353.
    PMID: 33452923 DOI: 10.1007/s00404-020-05950-3
    PURPOSE: To compare 3 consecutive days of hyperglycemic response following antenatal dexamethasone regimens of 12-mg or 6-mg doses 12 hourly in diet-controlled gestational diabetes.

    METHODS: A randomized controlled trial was carried out in a university hospital in Malaysia. Women with lifestyle-controlled gestational diabetes scheduled to receive clinically indicated antenatal corticosteroids (dexamethasone) were randomized to 12-mg 12 hourly for one day (2 × 12-mg) or 6-mg 12-hourly for two days (4 × 6-mg). 6-point (pre and 2-h postprandial) daily self-monitoring of capillary blood sugar profile for up to 3 consecutive days was started after the first dexamethasone injection. Hyperglycemia is defined as blood glucose pre-meal ≥ 5.3 or 2 h postprandial ≥ 6.7 mmol/L. The primary outcome was a number of hyperglycemic episodes in Day-1 (first 6 BSP points). A sample size of 30 per group (N = 60) was planned.

    RESULTS: Median [interquartile range] hyperglycemic episodes 4 [2.5-5] vs. 4 [3-5] p = 0.3 in the first day, 3 [2-4] vs. 1 [0-3] p = 0.01 on the second day, 0 [0-1] vs. 0 [0-1] p = 0.6 on the third day and over the entire 3 trial days 7 [6-9] vs. 6 [4-8] p = 0.17 for 6-mg vs. 12-mg arms, respectively. 2/30 (7%) in each arm received an anti-glycemic agent during the 3-day trial period (capillary glucose exceeded 11 mmol/L). Mean birth weight (2.89 vs. 2.49 kg p 

    Matched MeSH terms: Blood Glucose/analysis*
  8. Nawawi H, Sazali BS, Kamaruzaman BH, Yazid TN, Jemain AA, Ismail F, et al.
    Ann. Clin. Biochem., 2001 Nov;38(Pt 6):676-83.
    PMID: 11732650
    The effect of ambient temperature on the analytical and clinical performance of a glucose meter was examined. A total of 114 venous whole blood samples were analysed for glucose by a reference method, and by a glucose meter at 21-22 degrees C, room temperatures, 26-27 degrees C and 33-34 degrees C. Glucose meter readings at each temperature were compared with the reference values and evaluated by analysis of variance, Spearman's correlation, the percentage of glucose meter readings within +/- 10% of the reference value and error grid analysis. Analysis of covariance was used to determine the effect of temperature on glucose meter readings. There were no significant differences in the glucose meter readings and in accuracy of the meter readings between different temperatures. Temperature was not a significant independent determinant of the glucose meter readings. For each glucose concentration, the precision of the meter and clinical performance were comparable between the different temperatures. In conclusion, ambient temperature does not affect the accuracy, precision and clinical performance of the Omnitest Sensor.
    Matched MeSH terms: Blood Glucose/analysis
  9. Lim TO, Ding LM, Zaki M, Suleiman AB, Kew ST, Maimunah AH, et al.
    Med J Malaysia, 2000 Mar;55(1):65-77.
    PMID: 11072493 MyJurnal
    We describe the distribution of capillary blood glucose (BG) by age, sex and ethnicity in Malaysian adults. A national sample of 20,041 individuals aged 30 or older had usable data. They were selected by stratified 2-stage cluster sampling. BG was measured using reflectance photometer. Percentile tables and curves by age, sex and ethnicity are presented. The BG distribution was right skewed and showed the expected increase with age. Except in Indian, women had higher BG than men. There were also marked ethnic differences. Indian had the highest BG concentration, followed by Chinese, Malay and other indigenous ethnic group.
    Study name: National Health and Morbidity Survey (NHMS-1996)
    Matched MeSH terms: Blood Glucose/analysis*
  10. Khoo KL, Tan H, Liew YM, Sambhi JS, Aljafri AM, Hatijah A
    Med J Malaysia, 2000 Dec;55(4):439-50.
    PMID: 11221155
    The paper presents the results of a health screening programme conducted in 10 major centers in Malaysia--Kuala Lumpur, Penang, Ipoh, Johor Bahru, Alor Star, Kuala Terengganu, Malacca, Kota Bahru, Kuching and Kota Kinabalu during the National Heart Weeks, 1995-1997. There were 6,858 participants of both sexes aged between 6 years to 81 years old. The parameters involved in the screening programme were body mass index, blood pressure, heart rate, cholesterol and glucose. The following are the results of the study:- 1. The mean and standard deviation for the body mass index (BMI), systolic blood pressure (SBP), diastolic blood pressure (DBP), heart rate (HR), total cholesterol (TC) and non fasting (random) blood glucose (GL) of the volunteers studied were 24.3 +/- 4.0 kg/m2, 128.3 +/- 21.1 mmHg, 79.6 +/- 11.9 mmHg, 77.2 +/- 12.1 bpm, 5.33 +/- 1.37 mmol/l and 5.11 +/- 1.97 mmol/l respectively. 2. There was a rising trend for BMI, SBP, DBP, TC and GL with age. The HR was higher in the younger age group of those below 20 years. Males tended to have higher mean values than females except for HR which was similar in both sexes. 3. The Malays, Chinese and Indians seemed to have closely similar mean values for SBP, DBP and HR but the Indians possessed the highest BMI (25.62 +/- 3.90 kg/m2), TC (5.61 +/- 1.48 mmol/l) and GL (5.41 +/- 2.43 mmol/l) among the three major ethnic groups. While the Ibans had highest TC (6.07 + 1.09 mmol/l), their GL level was the lowest (4.76 +/- 1.15 mmol/l). The Kadazans had the lowest TC level (4.94 +/- 1.39 mmol/l) among all the ethnic groups. 4. Among the participants screened, 31.9% were overweight (BMI > or = 25), 7.6% were obese (BMI > or = 30); 26.8% had raised SBP (> or = 140 mmHg) and 19.3% had raised DBP (> or = 90 mmHg); 13.6% of the participants had increased HR (> or = 90 bpm), 22% had raised TC (> or = 6.20 mmol/l) and 2% had raised GL (> or = 11.00 mmol/l). There was a higher prevalence for abnormal values with increasing age until between the ages of 60 or 70 years, when the values began to fall. 5. Age was positively correlated with SBP (r = 0.41***, df = 4351), DBP (r = 0.27***, df = 4351), TC (r = 0.22***, df = 3303) and GL (r = 0.16***, df = 2442) but negatively correlated with HR (r = -0.13***, df = 4351). The BMI was positively correlated with SBP (r = 0.29***, df = 2769), DBP (r = 0.31***, df = 2769), TC (r = 0.16***, df = 2137) and GL (r = 0.11**, df = 1637) but there was no correlation with HR (r = 0.03NS, df = 2771). The SBP and DBP were highly correlated with each other (r = 0.75***, df = 4351) and they also showed highly significant positive correlation (r = 0.08***-0.13***, df = 2441-3301) with TC and GL. TC was positively correlated with GL (r = 0.05* df = 2319) but only at the 5% probability level.
    Matched MeSH terms: Blood Glucose/analysis*
  11. Singh R, Brouns F, Kovacs E
    PMID: 12236441
    The effects of 7.6% carbohydrate-electrolyte solution (CES) and placebos (P) on rehydration (R) after exercise-induced dehydration and on a subsequent time-trial (TT) of cycling performance were studied. Thirteen male subjects exercised in a thermally-controlled environment (28 degrees C, 63% RH) until 3% of their body weight was lost. After exercise, the subjects moved to a neutral environment (22 degrees C) and rested for 30 minutes prior to a 2-hour R period. During R, subjects were fed CES or P to a maximum volume of 120% of previous body mass loss at 0, 30, and 60 minutes, in bolus-doses of 50%, 40% and 30% respectively. After R, subjects performed a 1-hour TT with no further fluid intake. % R with CES was significantly higher than with P (70 +/- 3% vs 60 +/- 5%; p < 0.01). During the TT, blood glucose dropped in the CES group but not in the P group. It was found that, despite a more effective R with CES, the performance results did not differ between groups (65.1 +/- 2.2 minutes and 65.2 +/- 2.3 minutes for CES and P respectively). It is suggested that an insulin-mediated rebound effect on CHO metabolism during TT, in which no further CHO was supplied, nullified the benefits of rehydration.
    Matched MeSH terms: Blood Glucose/analysis
  12. Thambiah SC, Samsudin IN, George E, Zahari Sham SY, Lee HM, Muhamad MA, et al.
    Malays J Pathol, 2016 Aug;38(2):123-30.
    PMID: 27568669 MyJurnal
    The risk of coronary heart disease (CHD) is dramatically increased in diabetic patients due to their atherogenic lipid profile. The severity of CHD in diabetic patients has been found to be directly associated with glycated haemoglobin (HbA1c). According to the Malaysian Clinical Practice Guidelines on diabetes mellitus (DM), HbA1c level less than 6.5% reduces the risk of microvascular and macrovascular complications. Hence, this study aimed to determine the relationship between dyslipidaemia and glycaemic status in patients with type 2 DM (T2DM) patients in Hospital Putrajaya, a tertiary endocrine centre in Malaysia. This was a cross sectional, retrospective study of 214 T2DM patients with dyslipidaemia who had visited the endocrine clinic between January 2009 and December 2012. Significant correlations were found between fasting blood glucose (FBG) and HbA1c with total cholesterol (TC), triglyceride (TG), low density lipoprotein cholesterol (LDL), non-high density lipoprotein cholesterol (non-HDL), LDL/HDL ratio and TC/HDL ratio; greater correlation being with HbA1c than FBG. In patients with HbA1c ≥ 6.5%, TC, TG, non-HDL and TC/HDL ratio were significantly higher than in patients with HbA1c < 6.5%. Non-HDL, LDL/HDL ratio, TC/HDL ratio and HbA1c were significantly lower in patients on statin treatment than nontreated patients (p<0.05). This significant association between glycaemic status and dyslipidaemia emphasises the additional possible use of HbA1c as a biomarker for dyslipidaemia as well as a potential indirect predictor of cardiovascular disease (CVD) risk in T2DM patients.
    Matched MeSH terms: Blood Glucose/analysis*
  13. Lim TO, Selvan T, Suppiah A, Khan N, Ismail F
    Singapore Med J, 1992 Jun;33(3):287-9.
    PMID: 1631590
    The usefulness and validity of blood glucose measurement as an index of diabetic control were assessed with reference to serum fructosamine. Two hundred and twenty-eight non-insulin dependent diabetic out-patients were studied in the usual clinical setting. Fasting blood glucose (FBG) concentration was positively correlated with serum fructosamine (r = 0.42, t = 6.78 p less than 0.01). On the basis of their serum fructosamine concentrations, patients were divided into 3 groups. They were good control (fructosamine less than or equal to 288 umol/l), acceptable control (fructosamine less than or equal to 320 umol/l) and poor control groups (fructosamine greater than 320 umol/l). The mean fasting blood glucose concentration was significantly higher in the latter than the former 2 groups. However, at each level of control, there was a wide range of FBG concentrations. Thus, the value of FBG in predicting glycaemic control is limited. Its positive predictive value was only 32%, and its overall accuracy as an index of diabetic control was only 58% though its negative predictive value was high (93%). In 162 patients with poor diabetic control as indicated by their serum fructosamine concentrations, 81 (50%) of them had FBG less than 10 mmol/l on their clinic visit day. Fasting blood glucose is therefore not a reliable measure of good diabetic control, though it is useful in predicting poor control. FBG is simple to measure, cheap and rapidly available on clinic day, thus ensuring its continuing use. Doctors should be aware of its limitations and should not rely solely on FBG to assess diabetic control.
    Study site: Diabetic clinic, Hospital Mentakab, Pahang, Malaysia
    Matched MeSH terms: Blood Glucose/analysis*
  14. Wang KW, Balakrishnan V, Liauw PC, Chua EK, Vengadasalam D, Tan YT
    Singapore Med J, 1988 Feb;29(1):53-5.
    PMID: 3406769
    Diabetes mellitus is a common chronic disease in Singapore. Its occurrence in pregnant women was 1.3% in a previous report. In a survey of 145 consecutive pregnant women registered at Alexandra Hospital the incidence of gestational diabetes was 13.1% when a total screen with 75 gm oral glucose challenge was used. The mean age of this sample was 27 years and the mean gestation at screening 33 weeks. There was an excess of Malay and Indian patients. Fifty percent had traditional risk factors tor gestational diabetes. Whether this higher incidence is a result of more stringent screening and/or increased occurrence remains to be confirmed.
    Matched MeSH terms: Blood Glucose/analysis*
  15. Lim KL, Beng CG, Lau KS, Singh GN
    Med J Malaysia, 1974 Mar;28(3):154-9.
    PMID: 4278202
    Matched MeSH terms: Blood Glucose/analysis
  16. Rasaei B, Talib RA, Noor MI, Karandish M, Karim NA
    Asia Pac J Clin Nutr, 2016 Dec;25(4):729-739.
    PMID: 27702715 DOI: 10.6133/apjcn.092015.46
    Sleep deprivation and coffee caffeine consumption have been shown to affect glucose homeostasis separately, but the combined effects of these two variables are unknown.
    Matched MeSH terms: Blood Glucose/analysis*
  17. TermehYousefi A, Tateno K, Bagheri S, Tanaka H
    Sci Rep, 2017 05 09;7(1):1623.
    PMID: 28487527 DOI: 10.1038/s41598-017-01855-5
    A method to fabricate a bioinspired nanobiosensor using electronic-based artificial taste receptors for glucose diagnosis is presented. Fabricated bioinspired glucose nanobiosensor designated based on an artificial taste bud including an amperometric glucose biosensor and taste bud-inspired circuits. In fact, the design of the taste bud-inspired circuits was inspired by the signal-processing mechanism of taste nerves which involves two layers. The first, known as a type II cell, detects the glucose by glucose oxidase and transduces the current signal obtained for the pulse pattern is conducted to the second layer, called type III cell, to induce synchronisation of the neural spiking activity. The oscillation results of fabricated bioinspired glucose nanobiosensor confirmed an increase in the frequency of the output pulse as a function of the glucose concentration. At high glucose concentrations, the bioinspired glucose nanobiosensor showed a pulse train of alternating short and long interpulse intervals. A computational analysis performed to validate the hypothesis, which was successfully reproduced the alternating behaviour of bioinspired glucose our nanobiosensor by increasing the output frequency and alternation of pulse intervals according to the reduction in the resistivity of the biosensor.
    Matched MeSH terms: Glucose/analysis*
  18. Tehrani RM, Ab Ghani S
    Biosens Bioelectron, 2012 Oct-Dec;38(1):278-83.
    PMID: 22742810 DOI: 10.1016/j.bios.2012.05.044
    A non-enzymatic glucose sensor of multi-walled carbon nanotube-ruthenium oxide/composite paste electrode (MWCNT-RuO(2)/CPE) was developed. The electrode was characterized by using XRD, SEM, TEM and EIS. Meanwhile, cyclic voltammetry and amperometry were used to check on the performances of the MWCNT-RuO(2)/CPE towards glucose. The proposed electrode has displayed a synergistic effect of RuO(2) and MWCNT on the electrocatalytic oxidation of glucose in 3M NaOH. This was possible via the formation of transitions of two redox pairs, viz. Ru(VI)/Ru(IV) and Ru(VII)/Ru(VI). A linear range of 0.5-50mM glucose and a limit of detection of 33 μM glucose (S/N=3) were observed. There was no significant interference observable from the traditional interferences, viz. ascorbic acid and uric acid. Indeed, results so obtained have indicated that the developed MWCNT-RuO(2)/CPE would pave the way for a better future to glucose sensor development as its fabrication was without the use of any enzyme.
    Matched MeSH terms: Glucose/analysis*
  19. Brand-Miller J, Atkinson F, Rowan A
    Nutrients, 2013 Jan;5(1):23-31.
    PMID: 23306187 DOI: 10.3390/nu5010023
    Powdered milk products for children (Growing Up Milk Powders or GUMPs) containing added carbohydrates such as glucose and sucrose are now well established in parts of Asia. We surveyed GUMPs in Malaysia and Indonesia to determine the content of added carbohydrates. The ingredient lists and nutrition information panels were used to calculate the percentage of declared carbohydrates contributed by added carbohydrates and a subset of seven products was tested for their glycemic index (GI) and insulin responses in healthy adults. The glycemic load for each product was calculated. In total, 58 products (n = 24 in Malaysia and n = 34 in Indonesia) were surveyed. Added carbohydrate content (excluding fibre) ranged from 0 to 21.5 g per serve. Milk powders without added sources of carbohydrate had similar GI values to standard liquid whole milk. Products containing maltodextrins, corn or glucose syrups increased the GI by more than 2-fold, and glycemic load (GL) by 7-fold compared to milk powders with no added carbohydrates. Insulin responses were significantly but not strongly correlated with glucose responses (r = 0.32, p < 0.006). Children's milk powders containing higher levels of added carbohydrate ingredients elicit higher glucose and insulin responses than liquid or powdered whole milk.
    Matched MeSH terms: Blood Glucose/analysis*
  20. Zaki R, Bulgiba A, Ismail NA
    Prev Med, 2013;57 Suppl:S80-2.
    PMID: 23313586 DOI: 10.1016/j.ypmed.2013.01.003
    The Bland-Altman method is the most popular method used to assess the agreement of medical instruments. The main concern about this method is the presence of proportional bias. The slope of the regression line fitted to the Bland-Altman plot should be tested to exclude proportional bias. The aim of this study was to determine whether the overestimation of bias in the Bland-Altman analysis is still present even when the proportional bias has been excluded.
    Matched MeSH terms: Blood Glucose/analysis
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links