Displaying publications 21 - 40 of 132 in total

Abstract:
Sort:
  1. Nema SK, Behera G, Poduval M
    Malays Orthop J, 2018 Jul;12(2):65-67.
    PMID: 30112134 DOI: 10.5704/MOJ.1807.016
    We present an unusual case of five months old neglected anterior dislocation of the right elbow joint in a 19-year old man. The patient had been initially treated by a traditional bone setter, but the elbow remained unreduced. He presented to us with pain, deformity and limited range of motion of his right elbow joint. Radiographs revealed an unreduced anterior dislocation of the right elbow joint. We describe the problems encountered during open reduction and rehabilitation and result one year after the operation with the patient having a stable elbow and a functional range of motion.
    Matched MeSH terms: Range of Motion, Articular
  2. Abd Rahman NA, Li S, Schmid S, Shaharudin S
    Phys Ther Sport, 2023 Jan;59:60-72.
    PMID: 36516512 DOI: 10.1016/j.ptsp.2022.11.011
    Low back pain (LBP) can result in increased direct medical and non-medical costs to patients, employers, and health care providers. This systematic review aimed to provide a better understanding of the biomechanical factors associated with chronic non-specific LBP in adults. SCOPUS, ScienceDirect, MEDLINE, and Web of Science databases were searched. In total, 26 studies were included and significant differences were noted between healthy controls and LBP patients in various motion. Biomechanical factors among adults with non-specific LBP were altered and differed as compared to healthy controls in various motion might be to compensate the pain during those motions. This review highlighted the biomechanical differences across those with non-specific LBP and healthy adults. Both groups showed a similar level of pain during functional tasks but LBP patients suffered from a moderate level of disability. Future studies should not rely on questionnaire-based pain scale only. The biomechanical factors summarized in this review can be used to diagnose non-specific LBP accurately, and as modifiable targets for exercise-based intervention.
    Matched MeSH terms: Range of Motion, Articular
  3. Leong LX, Chai SC, Howell JW, Mohd Rasdi HF, Abdul Rahman NR
    PLoS One, 2024;19(8):e0307033.
    PMID: 39137205 DOI: 10.1371/journal.pone.0307033
    BACKGROUND: Evidence supports the use of hand-based metacarpophalangeal joint (MCPJ) blocking splints as an intervention for trigger finger (TF). In practice, finger-based relative motion (RM) splints are also implemented without evidence.

    PURPOSE: This randomized comparative trial (RCT) aims to evaluate implementation of MCPJ blocking and RM splints for effectiveness, function, occupational performance and wearability after 6 weeks of TF management.

    METHODS AND ANALYSIS: Priori analysis determined 36 individuals were needed for random assignment to the RM or MCPJ blocking splint groups. Individuals must be aged ≥21 years, and diagnosed with TF involving ≥1 finger. For blinding purposes, the primary author screens for eligibility, fabricates the splints and educates. Therapist A administers the primary outcome measures Week-1 and Week-6-stage of stenosing tenosynovitis and secondary outcome measures- number of triggering events in 10 active fists, visual analog scales (VAS) for pain, splint comfort and satisfaction, Disabilities of the Arm, Shoulder and Hand, and Canadian Occupational Performance Measure. Therapist B in Week-3 instructs participants in deep tissue massage and administers splint wearability VASs. The RM pencil test is used to determine the affected finger(s) MCPJ splint position i.e., more extension or flexion based on participant response. The MCPJ blocking splint holds the MCPJ in a neutral position. Analysis involves a mixed-effects ANOVA to compare Week-1 and Week-6 primary and secondary outcomes.

    RESULTS: Recruitment and data collection are ongoing.

    DISCUSSION: Biomechanically RM splints control tendon excursion and reduce passive tendon tension while allowing unencumbered finger motion and hand function. Hence clinicians use RM splints as an intervention for TF, despite the lack of implementation evidence. This RCT implements a function-focused as well as patient-centered approach with partial blinding of assessors and participants.

    CONCLUSION: We anticipate that this study will provide evidence for the implementation of RM splints to manage adults with TF.

    TRIAL REGISTRATION: Clinical trial registration This trial is registered with ClinicalTrials.gov (NCT05763017).

    Matched MeSH terms: Range of Motion, Articular
  4. Islam A, Sundaraj K, Ahmad RB, Sundaraj S, Ahamed NU, Ali MA
    Muscle Nerve, 2015 Jun;51(6):899-906.
    PMID: 25204740 DOI: 10.1002/mus.24454
    In this study, we analyzed the crosstalk in mechanomyographic (MMG) signals generated by the extensor digitorum (ED), extensor carpi ulnaris (ECU), and flexor carpi ulnaris (FCU) muscles of the forearm during wrist flexion (WF) and extension (WE) and radial (RD) and ulnar (UD) deviations.
    Matched MeSH terms: Range of Motion, Articular/physiology*
  5. Islam MA, Sundaraj K, Ahmad RB, Sundaraj S, Ahamed NU, Ali MA
    PLoS One, 2014;9(8):e104280.
    PMID: 25090008 DOI: 10.1371/journal.pone.0104280
    In mechanomyography (MMG), crosstalk refers to the contamination of the signal from the muscle of interest by the signal from another muscle or muscle group that is in close proximity.
    Matched MeSH terms: Range of Motion, Articular/physiology
  6. Abd Razak NA, Abu Osman NA, Wan Abas WA
    Disabil Rehabil Assist Technol, 2013 May;8(3):255-60.
    PMID: 22830946 DOI: 10.3109/17483107.2012.704654
    This study examined the kinematic differences between a body-powered prosthesis and a biomechatronics prosthesis as a transradial amputee performed activities that involve flexion/extension and supination/pronation of the wrist.
    Matched MeSH terms: Range of Motion, Articular/physiology*
  7. Amiri-Khorasani M, Abu Osman NA, Yusof A
    J Strength Cond Res, 2011 Jun;25(6):1647-52.
    PMID: 21358428 DOI: 10.1519/JSC.0b013e3181db9f41
    The purpose of this study was to examine the effects of static and dynamic stretching within a pre-exercise warm-up on hip dynamic range of motion (DROM) during instep kicking in professional soccer players. The kicking motions of dominant legs were captured from 18 professional adult male soccer players (height: 180.38 ± 7.34 cm; mass: 69.77 ± 9.73 kg; age: 19.22 ± 1.83 years) using 4 3-dimensional digital video cameras at 50 Hz. Hip DROM at backward, forward, and follow-through phases (instep kick phases) after different warm-up protocols consisting of static, dynamic, and no-stretching on 3 nonconsecutive test days were captured for analysis. During the backswing phase, there was no difference in DROM after the dynamic stretching compared with the static stretching relative to the no-stretching method. There was a significant difference in DROM after the dynamic stretching compared with the static stretching relative to the no-stretching method during (a) the forward phase with p < 0.03, (b) the follow-through phase with p < 0.01, and (c) all phases with p < 0.01. We concluded that professional soccer players can perform a higher DROM of the hip joint during the instep kick after dynamic stretching incorporated in warm-ups, hence increasing the chances of scoring and injury prevention during soccer games.
    Matched MeSH terms: Range of Motion, Articular/physiology*
  8. Chan CY, Kwan MK, Saravanan S, Saw LB, Deepak AS
    Med J Malaysia, 2007 Mar;62(1):33-5.
    PMID: 17682567 MyJurnal
    Assessment of the curve flexibility is a crucial step in a surgeon's pre-operative planning for scoliosis surgery. Many techniques have been described. These include traction films, supine side bending films, push prone techniques, traction under general anaesthesia as well as fulcrum bending film. In this study, we studied the pre- and immediate post-operative radiographs of twenty eight adolescent idiopathic scoliosis (AIS) patients who were corrected using pedicle screw systems between January 2004 and August 2006. There were twenty two females and six male patients. The mean age of the patients were 17.5 years with a range of 12 to 38 years. Skeletal maturity of the patients was assessed by Risser's score. The majority was Risser 4 (15 cases, 53.6%). Based on King and Moe's classification, the most common curve was type 3 curve (15 cases, 53.6%). Among the twenty eight patients, twenty three patients underwent only posterior correction, while 5 patients underwent additional anterior release surgery. The mean pre-operative Cobb's angle for the posterior surgery group was 65.5 +/- 13.9 degrees and the mean post-operative Cobb's angle was 32.9 +/- 12.6 degrees. There was no difference between the mean correction estimated by fulcrum bending films (Fulcrum Flexibility) and the post- operative Correction Rate figures (44.2% vs. 49.9%). The mean Fulcrum Bending Correction Index (FBCI) in this group of patients is 112.8%. In the group of patients who underwent additional anterior release, their curves were noted to be larger and less flexible with the mean pre-operative Cobb's angle and Fulcrum Flexibility of 90.4 degrees +/- 9.3 degrees and 23.4% respectively. The Fulcrum Bending Correction Index (FBCI) for this group of patients was significantly higher than the posterior surgery group: i.e. 164.0% vs 112.8%. Thus, anterior release does help to improve the correction significantly. The fulcrum bending films give good pre-operative estimation of the amount of correction to be expected post-operatively. The fulcrum bending films can help to identify the curve types which might require anterior release in order to improve the scoliosis correction. Using the Fulcrum Bending Correction Index (FBCI) will also enable surgeons to quantify more accurately the amount of correction achieved by taking into account the inherent flexibility of the spine.
    Matched MeSH terms: Range of Motion, Articular/physiology*
  9. Jawis MN, Singh R, Singh HJ, Yassin MN
    Br J Sports Med, 2005 Nov;39(11):825-9; discussion 825-9.
    PMID: 16244191
    OBJECTIVES: Anthropometric and physiological profiles of national sepak takraw players were determined.
    METHODS: Thirty nine players, specialising in the three playing positions (tekong/server, feeder, and killer/spiker) were divided into three age categories of under 15 (U15), under 18 (U18), and under 23 (U23) years of age. Height, weight, percent body fat (%bf), maximum oxygen consumption (Vo(2max)), range of motion (ROM), back and leg strength, and heart rate, for the estimation of oxygen consumption during matches, were recorded. Statistical analysis was performed using one way ANOVA for independent measurements and data are presented as mean+/-standard deviation.
    RESULTS: The U23 players were significantly taller and heavier with significantly better ROM of the neck, trunk, and ankle joints and back and leg strength than the U15 players. No significant difference was found in %bf between the three age categories. Mean maximum heart rate during exercise was significantly higher in the U15 group when compared to the U18 and U23 groups (p<0.05). Mean Vo2max was similar between the three groups. Estimated oxygen consumption during matches was 69.1%, 68.5%, and 56.4% of Vo2max in the killer, tekong, and the feeder groups, respectively.
    CONCLUSIONS: The mean height, body weight, and cardiopulmonary capacities of the players were within the Malaysian population norms, but were somewhat lower than those of players of other court games from other countries. %bf was also lower in these players. This study provides the much needed anthropometric and physiological data of sepak takraw players for further development of this sport.
    Matched MeSH terms: Range of Motion, Articular/physiology
  10. Chan CYW, Chiu CK, Kwan MK
    Spine (Phila Pa 1976), 2016 Aug 15;41(16):E973-E980.
    PMID: 26909833 DOI: 10.1097/BRS.0000000000001516
    STUDY DESIGN: A prospective study.

    OBJECTIVE: The aim of this study was to analyze the proximal thoracic (PT) flexibility and its compensatory ability above the "potential UIV."

    SUMMARY OF BACKGROUND DATA: Shoulder and neck imbalance can be caused by overcorrection of the main thoracic (MT) curve due to inability of PT segment to compensate.

    METHODS: Cervical supine side bending (CSB) radiographs of 100 Lenke 1 and 2 patients were studied. We further stratified Lenke 1 curves into Lenke 1-ve: PT side bending (PTSB) 80.0% of cases of the PT segment were unable to compensate at T3-T6. In Lenke 1+ve curves, 78.4% were unable to compensate at T6, followed by T5 (75.7%), T4 (73.0%), T3 (59.5%), T2 (27.0%), and T1 (21.6%). In Lenke 1-ve curves, 36.4% of cases were unable to compensate at T6, followed by T5 (45.5%), T4 (45.5%), T3 (30.3%), T2 (21.2%), and T1 (15.2%). A significant difference between Lenke 1-ve and Lenke 1+ve was observed from T3 to T6. The difference between Lenke 1+ve and Lenke 2 curves was significant only at T2.

    CONCLUSION: The compensation ability and the flexibility of the PT segments of Lenke 1-ve and Lenke 1+ve curves were different. Lenke 1+ve curves demonstrated similar characteristics to Lenke 2 curves.

    LEVEL OF EVIDENCE: 3.

    Matched MeSH terms: Range of Motion, Articular/physiology*
  11. Loh PY, Hayashi K, Nasir N, Muraki S
    J Mot Behav, 2020;52(5):634-642.
    PMID: 31571525 DOI: 10.1080/00222895.2019.1670128
    This study investigated the muscle activity and force variability in response to perturbation of assistive force during isometric elbow flexion. Sixteen healthy right-handed young men (age: 22.0 ± 1.1 years; height: 171.9 ± 4.8 cm; weight 68.4 ± 11.2 kg) were recruited and the muscle activity of biceps brachii and triceps brachii were assessed using surface electromyography. Workload force and assistive force applied on isometric elbow flexion significantly affected the changes in both biceps and triceps muscle activities. A higher assistive force was shown to result in reduced biceps muscle activity compared to the unassisted period. In contrast, the efficiency of the assistive force acting on the biceps decreased as the assistive force increased. In general, the force variability of the biceps muscle remained approximately the same at lower workload force conditions than that at higher workload force conditions. In conclusion, higher assistive force may not yield a higher performance efficiency in human-assistive force interaction.
    Matched MeSH terms: Range of Motion, Articular/physiology
  12. Bashaireh KM, Yabroudi MA, Nawasreh ZH, Al-Zyoud SM, Bashir NB, Aleshawi AJ, et al.
    Knee, 2020 Aug;27(4):1205-1211.
    PMID: 32711883 DOI: 10.1016/j.knee.2020.05.003
    BACKGROUND: A high incidence of joint laxity has been reported among Asians compared with Western populations, but clear differences between more specific ethnic populations have not been established. This study aimed to determine the average knee laxity in the Malaysian and Jordanian populations.

    METHODS: Jordanian and Malaysian medical students from our institution were invited to participate in the study. General demographic data and factors affecting joint laxity were obtained from each participant using a printed questionnaire. Both knees were examined using the anterior drawer test while in 90° of flexion. Knee laxity was measured by three separate independent investigators through a knee laxity tester.

    RESULTS: One hundred and eighty-six participants (95 females) were enrolled in the study. Among them, 108 Malaysians participated. The Jordanians had significantly higher knee laxity in both knees compared with the Malaysians. The mean average right knee laxity for Jordanians was 2.98 mm vs. 2.72 mm for Malaysians (P = 0.005). Similarly, the mean average left knee laxity for Jordanians was 2.95 mm, while for Malaysians, it was 2.62 mm (P = 0.0001). Furthermore, smokers had significantly more laxity in both knees. After performing a multivariate linear regression analysis for all factors, race was the only independent factor that affected knee laxity in both knees.

    CONCLUSIONS: Race is directly associated with knee laxity. Jordanians tend to have more laxity in knee joints compared with Malaysians. Larger multi-center and genetic studies are recommended to establish the racial differences between different ethnic groups.

    Matched MeSH terms: Range of Motion, Articular/physiology*
  13. Hasan H, Davids K, Chow JY, Kerr G
    Eur J Sport Sci, 2017 Apr;17(3):294-302.
    PMID: 27739339 DOI: 10.1080/17461391.2016.1241829
    This study investigated effects of wearing compression garments and textured insoles on modes of movement organisation emerging during performance of lower limb interceptive actions in association football. Participants were six skilled (age = 15.67 ± 0.74 years) and six less-skilled (age = 15.17 ± 1.1 years) football players. All participants performed 20 instep kicks with maximum velocity in four randomly organised insoles and socks conditions, (a) Smooth Socks with Smooth Insoles (SSSI); (b) Smooth Socks with Textured Insoles (SSTI); (c) Compression Socks with Smooth Insoles (CSSI); and (d), Compression Socks with Textured Insoles (CSTI). Results showed that, when wearing textured and compression materials (CSSI condition), less-skilled participants displayed significantly greater hip extension and flexion towards the ball contact phase, indicating larger ranges of motion in the kicking limb than in other conditions. Less-skilled participants also demonstrated greater variability in knee-ankle intralimb (angle-angle plots) coordination modes in the CSTI condition. Findings suggested that use of textured and compression materials increased attunement to somatosensory information from lower limb movement, to regulate performance of dynamic interceptive actions like kicking, especially in less-skilled individuals.
    Matched MeSH terms: Range of Motion, Articular/physiology
  14. Masni-Azian, Tanaka M
    Comput Biol Med, 2018 07 01;98:26-38.
    PMID: 29758454 DOI: 10.1016/j.compbiomed.2018.05.010
    Intervertebral disc degeneration involves changes in its material properties that affect the mechanical functions of the spinal system. However, the alteration of the biomechanics of a spinal segment through specific material degradation in a specific region is poorly understood. In this study, the influence of the constitutive material degeneration of disc tissues on the mechanics of a lower lumbar spinal unit was examined using a three-dimensional nonlinear finite element model of the L4-L5 functional spinal unit. Different grades of disc degeneration were simulated by introducing a degeneration factor to the corresponding material properties to represent fibrous nucleus, increased fibre and ground substance laxity, increased fibre stiffness and total annular fracture along posterior and posterolateral regions. The model was loaded with an axial compression of 500 N and pure moments of up to 10 Nm to simulate extension, flexion, lateral bending and axial rotation. To validate the model, the spinal motion and intradiscal pressure of healthy and degenerated discs with existing in vitro data were compared. The disc with a fibrous nucleus and the presence of intradiscal pressure increase the spinal instability during flexion and axial rotation, and the absence of intradiscal pressure increases the spinal instability in all directions. Bulging displacement and shear strains in the disc with total fracture and ground substance laxity are high in all of the loading cases. Our study could provide useful information to enhance our understanding of the influence of each constitutive component of the intervertebral disc on the mechanics of the spinal segment.
    Matched MeSH terms: Range of Motion, Articular/physiology
  15. Masni-Azian, Tanaka M
    Comput Methods Biomech Biomed Engin, 2017 Aug;20(10):1066-1076.
    PMID: 28532164 DOI: 10.1080/10255842.2017.1331345
    In the biomechanics field, material parameters calibration is significant for finite element (FE) model to ensure a legit estimation of biomechanical response. Determining an appropriate combination of calibration factors is challenging as each constitutive component responds differently. This study proposes a statistical factorial analysis approach using L16(4(5)) orthogonal array to evaluate material nonlinearity and applicable calibration factor of the intervertebral disc FE model in pure moment. The calibrated model exhibits improved agreement to the experimental findings for all directions. Appropriate combination of calibration parameter reduces the estimation gap to the experimental findings, ensuring agreeable biomechanical responses.
    Matched MeSH terms: Range of Motion, Articular/physiology
  16. Teo YX, Chan YS, Gouwanda D, Gopalai AA, Nurzaman SG, Thannirmalai S
    Sci Rep, 2021 07 22;11(1):15020.
    PMID: 34294775 DOI: 10.1038/s41598-021-94268-4
    Although global demand for palm oil has been increasing, most activities in the oil palm plantations still rely heavily on manual labour, which includes fresh fruit bunch (FFB) harvesting and loose fruit (LF) collection. As a result, harvesters and/or collectors face ergonomic risks resulting in musculoskeletal disorder (MSD) due to awkward, extreme and repetitive posture during their daily work routines. Traditionally, indirect approaches were adopted to assess these risks using a survey or manual visual observations. In this study, a direct measurement approach was performed using Inertial Measurement Units, and surface Electromyography sensors. The instruments were attached to different body parts of the plantation workers to quantify their muscle activities and assess the ergonomics risks during FFB harvesting and LF collection. The results revealed that the workers generally displayed poor and discomfort posture in both activities. Biceps, multifidus and longissimus muscles were found to be heavily used during FFB harvesting. Longissimus, iliocostalis, and multifidus muscles were the most used muscles during LF collection. These findings can be beneficial in the design of various assistive tools which could improve workers' posture, reduce the risk of injury and MSD, and potentially improve their overall productivity and quality of life.
    Matched MeSH terms: Range of Motion, Articular*
  17. AlDahas A, Devecchi V, Deane JA, Falla D
    PLoS One, 2024;19(5):e0303066.
    PMID: 38728251 DOI: 10.1371/journal.pone.0303066
    INTRODUCTION: People with chronic neck pain (CNP) commonly exhibit a range of physical impairments including cervical proprioceptive deficits. Assessing proprioception using a head mounted laser to assess joint position error (JPE) is a reliable and valid measure. However, the responsiveness of this measure has not been assessed.

    OBJECTIVE: To assess the responsiveness of the measure of cervical JPE after a 4-week home-based neck proprioceptive training intervention in people with CNP.

    DESIGN: An observational study to assess the responsiveness of the measure of cervical JPE.

    METHODS: The JPE test was assessed in people with CNP before and after 4 weeks of neck proprioception training. JPE was assessed as participants performed neck joint position sense tests for flexion, extension, right rotation, and left rotation in sitting and standing which were performed in a random order. Both the absolute and constant JPE were assessed. The intervention consisted of neck repositioning exercises as well as movement sense exercises. Cohen's d effect size was used to assess the internal responsiveness of the JPE test. The Pearson's correlation was used to assess the change of scores of the laser pointer and measures from inertial measurement units (IMUs) (external responsiveness).

    RESULTS: After 4 weeks of proprioception training, JPE assessed in sitting reduced from 2.69◦-3.57◦ to 1.88◦-1.98◦ for flexion, extension, and right rotation with large effect sizes (Cohen's d range: 1.25-2.00). For left rotation, JPE reduced from 3.23◦ to 1.9◦, and the effect size was close to being large (Cohen's d: 0.79). When assessed in standing, JPE reduced from 3.49◦-4.52◦ to 1.5◦-2.33◦ with large effect sizes (Cohen's d range: 0.89-1.25) for flexion, extension, right rotation, and left rotation. Large effect sizes were not observed for the constant JPE when assessed in either sitting or standing. The assessment of the external responsiveness revealed weak correlations between the change of scores obtained from the laser pointer and the IMUs for all movements, apart from the constant JPE in sitting for left rotation, which showed a strong correlation (r = 0.7).

    CONCLUSION: The results of this study showed that the measure of the JPE has sufficient internal responsiveness, however, the external responsiveness was inadequate. Further research is advised.

    Matched MeSH terms: Range of Motion, Articular/physiology
  18. Anuar MA, Todo M, Nagamine R, Hirokawa S
    ScientificWorldJournal, 2014;2014:586921.
    PMID: 25133247 DOI: 10.1155/2014/586921
    The primary objective of this study is to distinguish between mobile bearing and fixed bearing posterior stabilized knee prostheses in the mechanics performance using the finite element simulation. Quantifying the relative mechanics attributes and survivorship between the mobile bearing and the fixed bearing prosthesis remains in investigation among researchers. In the present study, 3-dimensional computational model of a clinically used mobile bearing PS type knee prosthesis was utilized to develop a finite element and dynamic simulation model. Combination of displacement and force driven knee motion was adapted to simulate a flexion motion from 0° to 135° with neutral, 10°, and 20° internal tibial rotation to represent deep knee bending. Introduction of the secondary moving articulation in the mobile bearing knee prosthesis has been found to maintain relatively low shear stress during deep knee motion with tibial rotation.
    Matched MeSH terms: Range of Motion, Articular
  19. Masjudin T, Kamari Zh
    Malays Orthop J, 2012 Nov;6(3):31-6.
    PMID: 25279053 DOI: 10.5704/MOJ.1207.0018
    This prospective randomised study was undertaken to compare surgical parameters as well as clinical and radiological outcomes of subvastus (SV) to midvastus (MV) approaches in staged bilateral total knee arthroplasty (TKA). Twenty-three patients, aged 55-76 years, who underwent staged bilateral TKAs, were followed up for 6 months. The SV approach was used on one knee and MV approach on the other. We found similar lateral retinacular release rates and patellar resurfacing rates between the two approaches .The SV approached knees had a more significant blood loss and increased operative time compared to the MV approached knees but they achieved significantly earlier active straightleg raises (SLR) postoperatively (p<0.05 for all). The average postoperative pain, flexion, and Knee Society scores were comparable for both approaches. TKA via SV vs. MV approaches provides comparable satisfactory short-term clinical and radiological outcomes, even though there was slightly more difficulty, more blood loss and longer operative times with the SV approach.
    Matched MeSH terms: Range of Motion, Articular
  20. Zainul-Abidin S, Lim B, Bin-Abd-Razak HR, Gatot C, Allen JC, Koh J, et al.
    Malays Orthop J, 2019 Jul;13(2):28-34.
    PMID: 31467648 DOI: 10.5704/MOJ.1907.005
    Introduction: Periprosthetic fractures are a devastating complication following total knee arthroplasty. Little is known about the effect of mechanical factors on the incidence of periprosthetic fractures. The aim of this study was to examine the correlation between pre-operative mechanical factors, like side of surgery, coronal alignment and pre-operative range of motion and intra-operative factors, and the incidence of a periprosthetic fracture, following primary total knee arthroplasty (TKA). Materials and Methods: Forty-two patients with periprosthetic fractures (PPF) after primary TKA were identified from our hospital arthroplasty registry. These patients were matched two-to-one for gender and age at primary knee arthroplasty to 84 patients without PPF. The incidence of periprosthetic fracture with regards to laterality, coronal alignment and pre-operative range of motion was analysed. Intra-operative factors like implant type, patellar resurfacing and notching were also analysed using logistic regression. Results: Coronal alignment, pre-operative range of motion and patella resurfacing were not significant predictors of periprosthetic fractures. Anterior femoral notching was found to be significantly higher in the fracture group with an odds ratio of 17. Left sided surgery was also significantly higher in the periprosthetic fracture group. Conclusion: Periprosthetic fractures are 17 times more likely to occur in a knee with anterior femoral notching. Preoperative factors like coronal alignment and poor preoperative range of motion do not seem to increase the risk of periprosthetic fractures after TKA.
    Matched MeSH terms: Range of Motion, Articular
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links