Displaying publications 41 - 60 of 77 in total

Abstract:
Sort:
  1. Al-Sohaim SI, Awang R, Zyoud SH, Rashid SM, Hashim S
    Hum Exp Toxicol, 2012 Mar;31(3):274-81.
    PMID: 21478291 DOI: 10.1177/0960327111405861
    The availability of antidotes may be considered essential and lifesaving in the management of certain poisonings. Surveys carried out in a number of countries have demonstrated inadequate availability of a variety of poisoning antidotes.
  2. Alajerami YS, Hashim S, Ramli AT, Saleh MA, Kadni T
    Radiat Prot Dosimetry, 2013 Jun;155(1):1-10.
    PMID: 23193136 DOI: 10.1093/rpd/ncs310
    The thermoluminescent properties of boric glass modified with lithium and potassium carbonates (LKB) and co-doped with CuO and MgO are reported for the first time. Two techniques are applied to investigate the effect of dopants and co-dopants on the thermal stimulation properties of LKB. The induced TL glow curves of a CuO-doped sample are found to be at 220°C with a single peak. An enhancement of about three times is shown with the increment of 0.1 mol % MgO as a co-dopant impurity. This enhancement may contribute to the ability of magnesium to create extra electron traps and consequently the energy transfer to monovalent Cu(+) ions. LKB:Cu,Mg is low Z material (Zeff=8.55), and observed 15 times less sensitive than LiF: Mg, Ti (TLD-100). The proposed dosemeter showed good linearity in TL dose-response, low fading and excellent reproducibility with a simple glow curve, and thus, can be used in the radiation dosimetry.
  3. Hashim S, Chin LY, Krishnasamy S, Sthaneswar P, Raja Mokhtar RA
    J Cardiothorac Surg, 2015;10:32.
    PMID: 25890367 DOI: 10.1186/s13019-015-0230-0
    Recently a biocompatible bone adhesive was introduced in addition to the sternal wires to expedite sternal union and improve patient recovery. In this study we aim to objectively assess the biomarker of pain in patient who received the biocompatible bone adhesive.
  4. Siti Nor Aishah AR, Mutalib A, Asma H, Baig AA, Naing NN, Hashim SE, et al.
    Med J Malaysia, 2020 11;75(6):685-690.
    PMID: 33219178
    OBJECTIVES: To design and develop a simple vision test algorithm for mobile application and perform a pilot study to determine its validity and reliability as a tool for vision test in the community.

    METHODS: A simple visual acuity test algorithm in the form of a single letter E display was designed as the optotype for development of a mobile application. The standardised optotype is presented at random to test visual acuity for corresponding level of 3/60, 6/60, 6/18, and 6/12. The final result is auto-generated based on the classification of the WHO for visual impairment and blindness. The Snellen chart was used as the gold standard to determine its validity while five different users were involved to determine its inter-rater reliability. A pilot study was performed between April till November 2019, in the Universiti Sultan Zainal Abidin Medical Centre (UMC) at Kuala Nerus and Mooris Optometrist Centre at Marang, Terengganu. A total of 279 participants aged four years old and above were involved in this study.

    RESULTS: The highest sensitivity was found at the vision level cut-off point of 6/12 with the percentage of 92.7% and 86.8% for the right and left eye, respectively. The specificity was more than 89% for all vision levels in both eyes. The Krippendorff's alpha value for the inter-rater reliability was 0.87 and 0.83.

    CONCLUSION: The relatively high level of validity and reliability obtained indicate the feasibility of using the designed optotype to develop a valid and reliable mobile app for vision test. The app can be used to screen vision by nonmedical persons, at anytime and anywhere to help improve public awareness and capability to correctly determine their visual status.

  5. Karim MKA, Rahim NA, Matsubara K, Hashim S, Mhareb MHA, Musa Y
    J Xray Sci Technol, 2019;27(1):139-147.
    PMID: 30584178 DOI: 10.3233/XST-180397
    BACKGROUND: Numerous techniques had been proposed to reduce radiation exposure in computed tomography (CT) including the use of radiation shielding.

    OBJECTIVE: This study aims to evaluate efficacy of using a bismuth breast shield and optimized scanning parameter to reduce breast absorbed doses from CT thorax examination.

    METHODS: Five protocols comprising the standard CT thorax clinical protocol (CP1) and four modified protocols (CP2 to CP5) were applied in anthropomorphic phantom scans. The phantom was configured as a female by placing a breast component on the chest. The breast component was divided into four quadrants, where 2 thermoluminescence dosimeters (TLD-100) were inserted into each quadrant to measure the absorbed dose. The bismuth shield was placed over the breast component during CP4 and CP5 scans.

    RESULTS: The pattern of absorbed doses in each breast and quadrant were approximately the same for all protocols, where the 4th quadrant > 3rd quadrant > 2nd quadrant > 1st quadrant. The mean absorbed dose value in CP3 was reduced to almost 34% of CP1's mean absorbed dose. It was reduced even lower to 15% of CP1's mean absorbed dose when the breast shield was used in CP5.

    CONCLUSION: This study showed that CT radiation exposure on the breast could be reduced by using a bismuth shield and low tube potential protocol without compromising the image quality.

  6. Majeed Alneamy JS, A Hameed Alnaish Z, Mohd Hashim SZ, Hamed Alnaish RA
    Comput Biol Med, 2019 09;112:103348.
    PMID: 31356992 DOI: 10.1016/j.compbiomed.2019.103348
    Accurate medical disease diagnosis is considered to be an important classification problem. The main goal of the classification process is to determine the class to which a certain pattern belongs. In this article, a new classification technique based on a combination of The Teaching Learning-Based Optimization (TLBO) algorithm and Fuzzy Wavelet Neural Network (FWNN) with Functional Link Neural Network (FLNN) is proposed. In addition, the TLBO algorithm is utilized for training the new hybrid Functional Fuzzy Wavelet Neural Network (FFWNN) and optimizing the learning parameters, which are weights, dilation and translation. To evaluate the performance of the proposed method, five standard medical datasets were used: Breast Cancer, Heart Disease, Hepatitis, Pima-Indian diabetes and Appendicitis. The efficiency of the proposed method is evaluated using 5-fold cross-validation and 10-fold cross-validation in terms of mean square error (MSE), classification accuracy, running time, sensitivity, specificity and kappa. The experimental results show that the efficiency of the proposed method for the medical classification problems is 98.309%, 91.1%, 91.39%, 88.67% and 93.51% for the Breast Cancer, Heart Disease, Hepatitis, Pima-Indian diabetes and Appendicitis datasets, respectively, in terms of accuracy after 30 runs for each dataset with low computational complexity. In addition, it has been observed that the proposed method has efficient performance compared with the performance of other methods found in the related previous studies.
  7. Alomari AH, Saleh MA, Hashim S, Alsayaheen A, Abdeldin I, Bani Khalaf R
    J Water Health, 2019 Dec;17(6):957-970.
    PMID: 31850902 DOI: 10.2166/wh.2019.158
    The current study was conducted to measure the activity concentration of the gross alpha and beta in 87 groundwater samples collected from the productive aquifers that constitute a major source of groundwater to evaluate the annual effective dose and the corresponding health impact on the population and to investigate the quality of groundwater in Jordan. The mean activity concentration of gross alpha and beta in groundwater ranges from 0.26 ± 0.03 to 3.58 ± 0.55 Bq L-1 and from 0.51 ± 0.07 to 3.43 ± 0.46 Bq L-1, respectively. A very strong relationship was found between gross alpha and beta activity concentrations. The annual effective dose for alpha and beta was found in the range of 0.32-2.40 mSv with a mean value of 0.89 mSv, which is nine times higher than the World Health Organization (WHO) recommended limit and one and half times higher than the national regulation limit. The mean lifetime risk was found to be 45.47 × 10-4 higher than the Jordanian estimated upper-bound lifetime risk of 25 × 10-4. The data obtained in the study would be the baseline for further epidemiological studies on health effects related to the exposure to natural radioactivity in Jordan.
  8. Mhareb MHA, Alajerami YSM, Alqahtani M, Alshahri F, Saleh N, Alonizan N, et al.
    Luminescence, 2020 Jun;35(4):525-533.
    PMID: 31883298 DOI: 10.1002/bio.3761
    Lithium borate (LB) glasses doped with dysprosium oxide (Dy2 O3 ) have been prepared by utilizing the conventional melt-quench technique. The prepared glass samples were exposed to 60 Co to check their dosimetric features and kinetic parameters. These features involve glow curves, annealing, fading, reproducibility, minimum detectable dose (MDD), and effective atomic number (Zeff ). Kinetic parameters including the frequency factors and activation energy were also determined using three methods (glow curve analysis, initial rise, and peak shape method) and were thoroughly interpreted. In addition, the incorporation of Dy impurities into LB enhanced the thermoluminescence sensitivity ~170 times. The glow from LB:Dy appeared as a single prominent peak at 190°C. The best annealing proceeding was obtained at 300°C for 30 min. Signal stability was reported for a period of 1 and 3 months with a reduction of 26% and 31%, respectively. The proposed glass samples showed promising dosimeter properties that can be recommended for personal radiation monitoring.
  9. Hashim S, Musa Y, Ghoshal SK, Ahmad NE, Hashim IH, Yusop M, et al.
    Appl Radiat Isot, 2018 May;135:7-11.
    PMID: 29353759 DOI: 10.1016/j.apradiso.2018.01.010
    The performance of optically stimulated luminescence dosimeters (OSLDs, Al2O3:C) was evaluated in terms of the operational quantity of HP(10) in Co-60 external beam teletherapy unit. The reproducibility, signal depletion, and dose linearity of each dosimeter was investigated. For ten repeated readouts, each dosimeter exposed to 50mSv was found to be reproducible below 1.9 ± 3% from the mean value, indicating good reader stability. Meanwhile, an average signal reduction of 0.5% per readout was found. The dose response revealed a good linearity within the dose range of 5-50mSv having nearly perfect regression line with R2 equals 0.9992. The accuracy of the measured doses were evaluated in terms of operational quantity HP(10), wherein the trumpet curve method was used respecting the 1990 International Commission on Radiological Protection (ICRP) standard. The accuracy of the overall measurements from all dosimeters was discerned to be within the trumpet curve and devoid of outlier. It is established that the achieved OSL Al2O3:C dosimeters are greatly reliable for equivalent dose assessment.
  10. Muhammad FF, Karim Sangawi AW, Hashim S, Ghoshal SK, Abdullah IK, Hameed SS
    PLoS One, 2019;14(5):e0216201.
    PMID: 31048867 DOI: 10.1371/journal.pone.0216201
    The behavior of solar cells and modules under various operational conditions can be determined effectively when their intrinsic parameters are accurately estimated and used to simulate the current-voltage (I-V) characteristics. This work proposed a new computational approach based on approximation and correction technique (ACT) for simple and efficient extraction of solar cells and modules parameters from the single-diode model. In this technique, an approximated value of series resistance (Rs) was first derived and used to determine the initial value of parallel resistance (Rp). Later, the final corrected values of Rs and Rp were obtained by resubstituting their approximated values in a five-loop iteration using the manipulated equations. For rapid evaluation and validation of the proposed technique, a software application was also created using MATLAB program. The correctness and robustness of the proposed technique was validated on five types of solar cells and modules operated at varied temperatures and irradiances. The lowest RMSE value was achieved for RTC France (7.78937E-4) and PVM 752 GaAs (2.10497E-4) solar cell. The legitimacy of ACT extracted parameters was established using a simple yet competitive implementation approach wherein the performance of the developed technique was compared with several state-of-the-art methods recently reported in the literature.
  11. Gunasagaran J, Ab Wahab N, Khoo SS, Shamsul SA, Shivdas S, Hashim S, et al.
    J Orthop Surg (Hong Kong), 2023;31(2):10225536231180330.
    PMID: 37256763 DOI: 10.1177/10225536231180330
    BACKGROUND: In complete brachial plexus injury, phrenic nerve (PN) is frequently used in neurotization for elbow flexion restoration. The advancement in video-assisted thoracoscopic surgery (VATS) allows full-length PN dissection intrathoracically for direct coaptation to recipient without nerve graft.

    PURPOSE: We report our experience in improving the surgical technique and its outcome.

    METHODS: Seven patients underwent PN dissection via VATS and full-length transfer to musculocutaneous nerve (MCN) or motor branch of biceps (MBB) from June 2015 to June 2018. Comparisons were made with similar group of patients who underwent conventional PN transfer.

    RESULTS: Mean age of patients was 21.9 years. All were males involved in motorcycle accidents who sustained complete brachial plexus injury. We found the elbow flexion recovery were earlier in full-length PN transfer. However, there was no statistically significant difference in elbow flexion strength at 3 years post-surgery.

    CONCLUSION: We propose full-length PN transfer for restoration of elbow flexion in patients with delayed presentation.

  12. Romli R, Abd Rahman R, Mohd Hashim S, Chew KT, Mohamad EMW, Mohammed Nawi A
    J Educ Health Promot, 2023;12:357.
    PMID: 38144028 DOI: 10.4103/jehp.jehp_1842_22
    INTRODUCTION: Cervical cancer remains a reproductive health burden. Pap smear (PS) screening can detect cervical cancer early but is underused despite being subsidized. Motivational factors play a role in promoting PS screening. This study aimed to determine the women's motivation toward PS screening based on Protection Motivation Theory (PMT), which mainly focused on sexual and screening status.

    MATERIALS AND METHODS: The study was conducted electronically throughout Malaysia from January to February 2022 by disseminating Google Form (https://forms.gle/cD7fkUKYR4Cq6kZC8) via multiple WhatsApp groups to reach 526 women aged 21-65 years. The questionnaire consists of 24 items based on seven PMT constructs [perceived vulnerability, perceived severity, self-efficacy, response efficacy, fear (threat appraisal), response costs (coping appraisal), and protection motivation]. The descriptive statistics and independent t-test was used to analyze data using IBM SPSS Statistics software, version 25.

    RESULTS: Most respondents were sexually active [80.6% (n = 424)] and have heard of PS screening [95.8% (n = 504)]. More than half of respondents did not have PS screening in the last three years [59.3% (n = 312)]. Sexually active women have heard and have undergone PS screening feel less threatened with low coping appraisals. Undergoing PS screening made women perceived more response efficacy (P =. 011), more self-efficacy (P

  13. Romli R, Mohd Hashim S, Abd Rahman R, Chew KT, Mohamad EMW, Mohammed Nawi A
    Gynecol Oncol Rep, 2024 Apr;52:101349.
    PMID: 38435346 DOI: 10.1016/j.gore.2024.101349
    PURPOSE: Cervical cancer (CC) screening remains challenging, where the motivational focus towards utilizing CC screening services is rarely highlighted. This study aimed to understand the motivation to undergo CC screening from women and healthcare practitioners' perspectives based on Protection Motivation Theory (PMT).

    METHOD: This qualitative study used the nominal group technique (NGT) and in-depth interview (IDI), where the NGT participants were healthcare practitioners from various disciplines (n = 12). Nominal group discussions were conducted via Zoom and involved one moderator, facilitator and observer. The IDI was conducted via Google Meet among seven women who had been included based on purposive sampling. All nominal group discussions and interviews were transcribed, verbatim and underwent deductive thematic analysis.

    RESULTS: Healthcare practitioners emphasized input on CC knowledge of epidemiology, risk, etiology, nature, and outcome to encourage motivation. Women underlined their important role in the family, and reducing the negative perception as a motivational focus. Having living example of witnessing the CC patient dying and fear of stigma of cancer could be the driven force to undergo screening. Emphasis on the important of sufficient knowledge and correct the misconceptions towards screening could impart the motivation among women.

    CONCLUSIONS: The motivational focus was enriched by the differing perspectives of the healthcare practitioners and women. The findings can guide intervention program development towards enhancing CC screening in the future.

  14. Hashim S, Beh HK, Hamil MS, Ismail Z, Majid AM
    Pharmacognosy Res, 2016 Oct-Dec;8(4):238-243.
    PMID: 27695261
    CONTEXT: Orthosiphon stamineus is a medicinal herb widely grown in Southeast Asia and tropical countries. It has been used traditionally as a diuretic, abdominal pain, kidney and bladder inflammation, gout, and hypertension.
    AIMS: This study aims to develop and validate the high-performance thin layer chromatography (HPTLC) method for quantification of rosmarinic acid (RA), 3'-hydroxy-5,6,7,4'-tetramethoxyflavone (TMF), sinensitin (SIN) and eupatorin (EUP) found in ethanol, 50% ethanol and water extract of O. stamineus leaves.
    MATERIALS AND METHODS: HPTLC method was conducted using an HPTLC system with a developed mobile phase system of toluene: ethyl acetate: formic acid (3:7:0.1) performed on precoated silica gel 60 F254 TLC plates. The method was validated based on linearity, accuracy, precision, limit of detection, limit of quantification (LOQ), and specificity, respectively. The detection of spots was observed at ultraviolet 254 nm and 366 nm.
    RESULTS: The linearity of RA, TMF, SIN, and EUP were obtained between 10 and 100 ng/spot with high correlation coefficient value (R2) of more than 0.986. The limit of detection was found to be 122.47 ± 3.95 (RA), 43.38 ± 0.79 (SIN), 17.26 ± 1.16 (TMF), and 46.80 ± 1.33 ng/spot (EUP), respectively. Whereas the LOQ was found to be 376.44 ± 6.70 (RA), 131.45 ± 2.39 (SIN), 52.30 ± 2.01 (TMF), and 141.82 ± 1.58 ng/spot (EUP), respectively.
    CONCLUSION: The proposed method showed good linearity, precision, accuracy, and high sensitivity. Hence, it may be applied in a routine quantification of RA, SIN, TMF, and EUP found in ethanol, 50% of ethanol and water extract of O. stamineus leaves.
    SUMMARY: HPTLC method provides rapid estimation of the marker compound for routine quality control analysis.The established HPTLC method is rapid for qualitative and quantitative fingerprinting of Orthosiphon stamineus extract used for commercial product.Four identified markers (RA, SIN, EUP and TMF) found in three a different type of O. stamineus extracts specifically ethanol, 50% ethanol and water extract were successfully quantified using HPTLC method. Abbreviations Used: HPTLC: High-performance thin layer chromatography; RA: Rosmarinic acid; TMF: 3'-hydroxy-5,6,7,4'-tetramethoxyflavone; SIN: Sinensitin; EUP: Eupatorin; E: Ethanol; EW: 50% ethanol; W: Water; BK: Batu Kurau; KB: Kepala Batas; S: Sik; CJ: Changkat Jering; SB: Sungai Buloh.
    KEYWORDS: rosmarinic acid; Eupatorin; Orthosiphon stamineus; high-performance thin-layer chromatography; sinensitin; validation
  15. Hashim S, Ibrahim SA, Che Omar SS, Alajerami YS, Saripan MI, Noor NM, et al.
    Appl Radiat Isot, 2014 Aug;90:258-60.
    PMID: 24858954 DOI: 10.1016/j.apradiso.2014.04.016
    Radiation effects of photon irradiation in pure Photonic Crystal Fibres (PCF) and Flat fibres (FF) are still much less investigated in thermoluminescense dosimetry (TLD). We have reported the TL response of PCF and FF subjected to 6 MV photon irradiation. The proposed dosimeter shows good linearity at doses ranging from 1 to 4 Gy. The small size of these detectors points to its use as a dosimeter at megavoltage energies, where better tissue-equivalence and the Bragg-Gray cavity theory prevails.
  16. Alajerami YS, Hashim S, Ghoshal SK, Ramli AT, Saleh MA, Ibrahim Z, et al.
    Appl Radiat Isot, 2013 Dec;82:12-9.
    PMID: 23948307 DOI: 10.1016/j.apradiso.2013.07.005
    Understanding the influence of co-dopants in the luminescence enhancement of carbonate glasses is the key issue in dosimetry. A series of borate glasses modified by lithium and potassium carbonate were synthesized by the melt-quenching method. The glass mixture activated with various concentrations of TiO2 and MgO was subjected to various doses of gamma-rays ((60)Co). The amorphous nature of the samples was confirmed by x-ray diffraction (XRD) spectra. The simple glowing curve of the glass doped with TiO2 features a peak at 230°C, whose intensity is maximal at 0.5 mol% of the dopant. The intensity of the glowing curve increases with the concentration of MgO added as a co-dopant up to 0.25 mol%, where it is two times higher than for the material without MgO thermoluminescence properties, including dose response, reproducibility, and fading were studied. The effective atomic number of the material was also determined. Kinetic parameters, such as kinetics order, activation energy, and frequency factor are estimated. The photoluminescence spectra of the titanium-doped glass consist of a prominent peaks at 480 nm when laser excitation at 650 nm is used. A three-fold photoluminescence enhancement and a blue shift of the peak were observed when 0.1% MgO was introduced. In addition, various physical parameters, such as ion concentration, polaron radius and internuclear distances were calculated. The mechanism for the thermoluminescence and photoluminescence enhancements are discussed.
  17. Mahadevan M, Navarro-Locsin G, Tan HK, Yamanaka N, Sonsuwan N, Wang PC, et al.
    Int J Pediatr Otorhinolaryngol, 2012 May;76(5):623-35.
    PMID: 22404948 DOI: 10.1016/j.ijporl.2012.02.031
    The burden of disease due to otitis media (OM) in Asia Pacific countries was reviewed to increase awareness and raise understanding within the region.
  18. Hughes AJ, Ariffin N, Huat TL, Abdul Molok H, Hashim S, Sarijo J, et al.
    Infect Control Hosp Epidemiol, 2005 Jan;26(1):100-4.
    PMID: 15693416
    Most reports of nosocomial infection (NI) prevalence have come from developed countries with established infection control programs. In developing countries, infection control is often not as well established due to lack of staff and resources. We examined the rate of NI in our institution.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links