Displaying publications 41 - 60 of 355 in total

Abstract:
Sort:
  1. Zainal D, Loo CS
    Singapore Med J, 1995 Aug;36(4):379-82.
    PMID: 8919150
    Acute (stab) peritoneal dialysis is commonly practised in Malaysia. This study is designed to improve the management of peritoneal dialysis (PD) in Hospital University Science Malaysia (HUSM). Consecutive peritoneal dialysis (PD) on adult inpatients from May 1992 to September 1992 were reviewed prospectively. There were 40 episodes of peritoneal dialysis on 27 patients during this period given at the rate of 2 PD per week. The mean age of patients were 53 +/- 15 years. Uraemia was the main indication for dialysis, while hyperkalaemia and pulmonary oedema were indications for urgent dialysis. Complications occurred in 14 episodes of dialysis (35%). The most common complication was bleeding in the peritoneal cavity while peritonitis was the second most common complication. Dialysis episodes complicated by peritonitis were done by less experienced performers compared to uncomplicated dialysis episodes. Overall mean time spent on each dialysis and time per cycle were longer than recommended (59 +/- 24 hours and 77 +/- 14 minutes). In conclusion, acute PD performed on patients admitted in Hospital University Malaysia was safe and had complication rates comparable to other established centres. However, improvements are possible through closer supervision of new doctors and tighter nursing precautions.
    Matched MeSH terms: Peritoneal Dialysis/adverse effects; Peritoneal Dialysis/statistics & numerical data*; Peritoneal Dialysis, Continuous Ambulatory/adverse effects; Peritoneal Dialysis, Continuous Ambulatory/statistics & numerical data*
  2. Cader RA, Gafor HA, Mohd R, Kong NC, Ibrahim S, Wan Hassan WH, et al.
    J Clin Nurs, 2013 Mar;22(5-6):741-8.
    PMID: 23039369 DOI: 10.1111/j.1365-2702.2012.04298.x
    To assess the degree of overhydration in our peritoneal dialysis patients and to examine the factors contributing to overhydration.
    Matched MeSH terms: Peritoneal Dialysis, Continuous Ambulatory*
  3. Mamat R, Kong NC, Ba'in A, Shah SA, Cader R, Wong V, et al.
    J Clin Nurs, 2012 Oct;21(19-20):2879-85.
    PMID: 22646855 DOI: 10.1111/j.1365-2702.2012.04091.x
    The main objective of the study was to correlate the target dry weight in haemodialysis (HD) patients as assessed clinically by nephrologists to those measured by the Body Composition Monitor (BCM - Fresenius) machine. The second objective was to compare pre and postdialysis changes of extracellular fluid and clinical parameters.
    Matched MeSH terms: Renal Dialysis*
  4. Lim TO, Goh A, Lim YN, Mohamad Zaher ZM, Suleiman AB
    Health Aff (Millwood), 2010 Dec;29(12):2214-22.
    PMID: 21134922 DOI: 10.1377/hlthaff.2009.0135
    Between 1990 and 2005, dialysis treatment rates in Malaysia increased more than eightfold. Dialysis treatment reached a level comparable to rates in developed countries. This remarkable transformation was brought about in large part by the Malaysian government's large-scale purchase of dialysis services from the highly competitive private sector. This paper traces a series of public- and private-sector reforms that dramatically increased access to dialysis for patients with kidney failure from 13 per million people in the population in 1990 to 119 per million in 2005. Not all developing countries have had uniformly positive experiences with private-sector participation in health care. However, our data suggest that strong participation by the private sector in Malaysia has helped make for a stronger health care system as well as healthier patients. Yet the policy decisions that enabled the private sector to participate fully in providing dialysis have not been repeated with other medical services.
    Matched MeSH terms: Dialysis/utilization*
  5. Konduk BA, Ucisik AH
    Med J Malaysia, 2004 May;59 Suppl B:53-4.
    PMID: 15468815
    The effect of hemodialysis on the mechanical behavior of a cellulosic Hemophane ME-IOH and one Polysulfone type hollow fibers was investigated. Mechanical tests showed that the deformation of polysulfone type of hollow fibers is entirely different than that of the other dialyser for the samples used and unused in hemodialysis. All the samples exposed to the dialysis showed decreased in ductility. Fracture surface studies proved that there was some alignment on the fracture surface. XRD and DSC experiments revealed structural changes had occurred.
    Matched MeSH terms: Renal Dialysis/instrumentation*
  6. Lim TO, Morad Z
    Med J Malaysia, 1998 Dec;53(4):392-400.
    PMID: 10971983
    Quality of life outcome (QOL) on dialysis is important. We determined the measurement properties of Spitzer's QL-index, a QOL measure, in our patients on chronic haemodialysis. The QL-index measures 5 dimensions of QOL (activity, daily activities, general health, social support and psychological outlook). 59 haemodialysis (HD) patients from 2 centres were rated by 5 raters. Inter-rater agreement for the total score was good with a mean intra-class correlation coefficient 0.66 (range 0.47-0.81). That for dimension scores however was poor (weighted kappa range 0.07-1). Systematic differences between raters were also observed. Intra-rater agreement was generally better than inter-rater agreement. Significant gradients in scores were observed by age, serum albumin, comorbid disorders, previous hospitalisation, capacity for self care HD and rehabilitation status thus providing evidence for construct validity. The distribution of total scores was skewed indicating poor discriminatory ability. Nevertheless, QL-index has acceptable measurement properties for application in dialysis patients.
    Matched MeSH terms: Renal Dialysis*
  7. Lim TO, Lee DG, Zaki M
    Med J Malaysia, 2000 Jun;55(2):188-95.
    PMID: 19839147
    We determined the provision for dialysis treatment in Malaysia. There were 181 dialysis centres as at 1st June 1999 (161 Haemodialysis (HD) and 20 Continuous Ambulatory Peritoneal Dialysis (CAPD) centres), providing treatment for 5614 patients. This is equivalent to an estimated prevalence rate of 253 patients per million population (pmp) and new dialysis acceptance rate of 49 patients pmp. Dialysis facilities were widely distributed throughout the country though rather unevenly among states. Penang, Selangor/KL, Malacca led with number of dialysis patients pmp ranging from 417 to 480. Kelantan and Sabah had the lowest provision with 51 and 64 patients pmp respectively. There were more centres and HD capacity in the private sector while the Non-Government Organisation and public sectors had about the same capacity. However the public sector had more patients on account of availability of CAPD and home HD services, as well as low HD capacity to patient ratio. The number ofcentres, HD capacity and patients have increased rapidly especially since 1991; the estimated growth rates were 16.5 centres/year, 658 capacity/year, and 392 patients/year respectively. There was also a trend toward increasing over-capacity in the private and NGO sectors. In conclusion, the level of dialysis provision is increasing, indicating increasing accessibility of dialysis treatment in Malaysia. Over-capacity is a concern in the private and NGO sectors. Thus funding agencies should be encouraged to source provision from those sectors. The public sector still has the crucial role of providing for under-served areas in the country.
    Matched MeSH terms: Renal Dialysis/utilization*
  8. Fan KS, Suleiman AB
    Med J Malaysia, 1985 Jun;40(2):101-6.
    PMID: 3834279
    226 peritoneal dialyses were performed on 100 patients. 28 patients presented with acute renal failure. Uraemia was the most frequent indication for dialysis. Peritonitis was an important complication and Acinetobacter species accounted for 51.5% of the positive cultures. Other complications included poor dialysate drainage and hypokalemia. Mortality was mainly due to causes unrelated to peritoneal dialysis.
    Matched MeSH terms: Peritoneal Dialysis/adverse effects*
  9. Lim JH, Chinna K, Khosla P, Karupaiah T, Daud ZAM
    PMID: 33066603 DOI: 10.3390/ijerph17207479
    Dietary non-adherence is pervasive in the hemodialysis (HD) population. Health literacy is a plausible predictor of dietary adherence in HD patients, but its putative mechanism is scarcely studied. Thus, this study aimed to establish the causal model linking nutrition literacy to dietary adherence in the HD population. This was a multi-centre, cross-sectional study, involving 218 randomly selected multi-ethnic HD patients from nine dialysis centres in Klang Valley, Malaysia. Dietary adherence and self-management skills were assessed using validated End-Stage Renal Disease Adherence Questionnaire and Perceived Kidney/Dialysis Self-Management Scale, respectively. Validated self-developed scales were used to gauge nutrition literacy, dietary knowledge and Health Belief Model constructs. Relationships between variables were examined by multiple linear regressions and partial least squares structural equation modeling. Limited nutrition literacy was evident in 46.3% of the HD patients, associated with older age, lower education level, and shorter dialysis vintage. Dietary adherence rate was at 34.9%. Nutrition literacy (β= 0.390, p < 0.001) was an independent predictor of dietary adherence, mediated by self-efficacy (SIE = 0.186, BC 95% CI 0.110-0.280) and self-management skills (SIE = 0.192, BC 95% CI 0.103-0.304). Thus, nutrition literacy-enhancing strategies targeting self-efficacy and self-management skills should be considered to enhance dietary adherence in the HD population.
    Matched MeSH terms: Renal Dialysis*
  10. Irfan M, Irfan M, Shah SM, Baig N, Saleh TA, Ahmed M, et al.
    Mater Sci Eng C Mater Biol Appl, 2019 Oct;103:109769.
    PMID: 31349444 DOI: 10.1016/j.msec.2019.109769
    Non-covalent electrostatic interaction between amide nitrogen and carbonyl carbon of shorter chain length of polyvinylpyrrolidone (PVP-k25) was developed with in-house carboxylic oxidized multiwall carbon nanotubes (O-MWCNT) and then blended with Polyethersulfone (PES) polymer. FTIR analysis was utilized to confirm bonding nature of nano-composites (NCs) of O-MWCNT/PVP-k25 and casting membranes. Non-solvent induces phase separation process developed regular finger-like channels in composite membranes whereas pristine PES exhibited spongy entities as studied by cross sectional analysis report of FESEM. Further, FESEM instrument was also utilized to observe the dispersion of O-MWCNT/PVP based nanocomposite (NCs) with PES and membranes leaching phenomena analysis. Contact angle experiments described 24% improvement of hydrophilic behaviour, leaching ratio of additives was reduced to 1.89%, whereas water flux enhanced up to 6 times. Bovine serum albumin (BSA) and lysozyme based antifouling analysis shown up to 25% improvement, whereas 84% of water flux was regained after protein fouling than pristine PES. Anticoagulant activity was reported by estimating prothrombin, thrombin, plasma re-calcification times and production of fibrinogen cluster with platelets-adhesions photographs and hemolysis experiments. Composite membranes exhibited 3.4 and 3 times better dialysis clearance ratios of urea and creatinine solutes as compared to the raw PES membrane.
    Matched MeSH terms: Renal Dialysis/instrumentation*
  11. Khor BH, Sualeheen A, Sahathevan S, Chinna K, Gafor AHA, Bavanandan S, et al.
    Sci Rep, 2020 07 23;10(1):12278.
    PMID: 32704087 DOI: 10.1038/s41598-020-68893-4
    Sources of dietary phosphate differentially contribute to hyperphosphatemia in maintenance haemodialysis (MHD) patients. This cross-sectional study in Malaysia investigated association between dietary patterns and serum phosphorus in MHD patients. Dietary patterns were derived by principal component analysis, based on 27 food groups shortlisted from 3-day dietary recalls of 435 MHD patients. Associations of serum phosphorus were examined with identified dietary patterns. Three dietary patterns emerged: Home foods (HFdp), Sugar-sweetened beverages (SSBdp), and Eating out noodles (EO-Ndp). The highest tertile of patients in HF (T3-HFdp) pattern significantly associated with higher intakes of total protein (p = 0.002), animal protein (p = 0.001), and animal-based organic phosphate (p  2.00 mmol/l was significantly 2.35 times higher (p = 0.005) with the T3-SSBdp. The SSBdp was associated with greater consumption of inorganic phosphate and higher serum phosphorus levels.
    Matched MeSH terms: Renal Dialysis*
  12. Liu WJ, Musa R, Chew TF, Lim CTS, Morad Z, Bujang MAB
    Am J Med Sci, 2018 04;355(4):322-330.
    PMID: 29661345 DOI: 10.1016/j.amjms.2017.11.015
    BACKGROUND: The effect of dialysis treatment is complex, with both clinical and socio-psychological effects. In this study, we aimed to assess the psychological status of this growing population of end-stage renal disease.

    METHODS: Using the Short Form of Depression, Anxiety and Stress Scale (DASS21) questionnaire, we aimed (1) to measure the psychological states of hemodialysis (HD) or peritoneal dialysis (PD) subjects from 15 sites, (2) to compare DASS21 scores between HD and PD, and (3) to identify the associated demographic and medical factors of better psychological states.

    RESULTS: A total of 1,332 were eligible for analysis. Stress (48%) recorded the highest negative emotional states, followed by depression (37%) and anxiety (20%). By multivariate analysis, normal body mass index weight status, religion and absence of coronary artery disease were associated with lower score for depression, anxiety and stress, respectively. Tertiary education was associated with the lowest score in depression and anxiety, whereas HD had a lower score in stress than PD. A younger age was associated with worse DASS21 score of anxiety and stress.

    CONCLUSIONS: Obesity, religion and coronary artery disease were significantly associated with all 3 symptoms of depression, anxiety and stress. Older age has a protective effect on anxiety and stress. Further study is needed to evaluate the relationship between these significant factors and each psychological state.

    Matched MeSH terms: Renal Dialysis; Peritoneal Dialysis
  13. Harvinder, G.S., Chee, W.S.S., Karupaiah, T., Sahathevan, S., Chinna, K., Ghazali, A., et al.
    Malays J Nutr, 2013;19(3):271-283.
    MyJurnal
    Introduction: Malnutrition is a serious unresolved nutritional problem amongst dialysis patients associated with increased mortality and morbidity and prevalence differs according to dialysis modalities. This study compared proteinenergy malnutrition (PEM) prevalence in haemodialysis (HD) and continuous ambulatory peritoneal dialysis (CAPD) patients. Methods: A total of 155 HD and 90 CAPD patients were enrolled. PEM prevalence was determined using body mass index (BMI), serum albumin, Dialysis Malnutrition Score (DMS) and dietary intake. Results: CAPD patients had significantly higher BMI (24.1 ± 4.8 kg/m2 vs. 22.7 ± 4.8 kg/m2; p=0.024) and mid-arm muscle area (32.1±12.4 cm2 vs. 29.5 ± 15.9 cm2; p=0.044) than HD patients. They also had significantly lower serum albumin (31 ± 5 g/L vs. 35 ± 6 g/L; p
    Matched MeSH terms: Renal Dialysis; Peritoneal Dialysis, Continuous Ambulatory
  14. Abidin MNZ, Goh PS, Ismail AF, Othman MHD, Hasbullah H, Said N, et al.
    Mater Sci Eng C Mater Biol Appl, 2016 Nov 01;68:540-550.
    PMID: 27524052 DOI: 10.1016/j.msec.2016.06.039
    Poly (citric acid)-grafted-MWCNT (PCA-g-MWCNT) was incorporated as nanofiller in polyethersulfone (PES) to produce hemodialysis mixed matrix membrane (MMM). Citric acid monohydrate was polymerized onto the surface of MWCNTs by polycondensation. Neat PES membrane and PES/MWCNTs MMMs were fabricated by dry-wet spinning technique. The membranes were characterized in terms of morphology, pure water flux (PWF) and bovine serum albumin (BSA) protein rejection. The grafting yield of PCA onto MWCNTs was calculated as 149.2%. The decrease of contact angle from 77.56° to 56.06° for PES/PCA-g-MWCNTs membrane indicated the increase in surface hydrophilicity, which rendered positive impacts on the PWF and BSA rejection of the membrane. The PWF increased from 15.8Lm(-2)h(-1) to 95.36Lm(-2)h(-1) upon the incorporation of PCA-g-MWCNTs due to the attachment of abundant hydrophilic groups that present on the MWCNTs, which have improved the affinity of membrane towards the water molecules. For protein rejection, the PES/PCA-g-MWCNTs MMM rejected 95.2% of BSA whereas neat PES membrane demonstrated protein rejection of 90.2%. Compared to commercial PES hemodialysis membrane, the PES/PCA-g-MWCNTs MMMs showed less flux decline behavior and better PWF recovery ratio, suggesting that the membrane antifouling performance was improved. The incorporation of PCA-g-MWCNTs enhanced the separation features and antifouling capabilities of the PES membrane for hemodialysis application.
    Matched MeSH terms: Renal Dialysis*
  15. Bavanandan S, Ahmad G, Teo AH, Chen L, Liu FX
    Value Health Reg Issues, 2016 May;9:8-14.
    PMID: 27881266 DOI: 10.1016/j.vhri.2015.06.003
    OBJECTIVES: To investigate the 5-year health care budget impact of variable distribution of adult patients treated with peritoneal dialysis (PD) and in-center hemodialysis (ICHD) on government funding in Malaysia.

    METHODS: An Excel-based budget impact model was constructed to assess dialysis-associated costs when changing dialysis modalities between PD and ICHD. The model incorporates the current modality distribution and accounts for Malaysian government dialysis payments and erythropoiesis-stimulating agent costs. Epidemiological data including dialysis prevalence, incidence, mortality, and transplant rates from the Malaysian renal registry reports were used to estimate the dialysis patient population for the next 5 years. The baseline scenario assumed a stable distribution of PD (8%) and ICHD (92%) over 5 years. Alternative scenarios included the prevalence of PD increasing by 2.5%, 5.0%, and 7.5% or decreasing 1% yearly over 5 years. All four scenarios were accompanied with commensurate changes in ICHD.

    RESULTS: Under the current best available cost information, an increase in the prevalent PD population from 8% in 2014 to 18%, 28%, or 38% in 2018 is predicted to result in 5-year cumulative savings of Ringgit Malaysia (RM) 7.98 million, RM15.96 million, and RM23.93 million, respectively, for the Malaysian government. If the prevalent PD population were to decrease from 8% in 2014 to 4.0% by 2018, the total expenditure for dialysis treatments would increase by RM3.19 million over the next 5 years.

    CONCLUSIONS: Under the current cost information associated with PD and HD paid by the Malaysian government, increasing the proportion of patients on PD could potentially reduce dialysis-associated costs in Malaysia.

    Matched MeSH terms: Renal Dialysis; Peritoneal Dialysis
  16. Irfan M, Irfan M, Idris A, Baig N, Saleh TA, Nasiri R, et al.
    J Biomed Mater Res A, 2019 03;107(3):513-525.
    PMID: 30484939 DOI: 10.1002/jbm.a.36566
    This study focused to optimize the performance of polyethersulfone (PES) hemodialysis (HD) membrane using carboxylic functionalized multiwall carbon nanotubes (c-MWCNT) and lower molecular weight grade of polyvinylpyrrolidone (PVP-k30). Initially, MWCNT were chemically functionalized by acid treatment and nanocomposites (NCs) of PVP-k30 and c-MWCNT were formed and subsequently blended with PES polymer. The spectra of FTIR of the HD membranes revealed that NCs has strong hydrogen bonding and their addition to PES polymer improved the capillary system of membranes as confirmed by Field Emission Scanning Electron Microscope (FESEM) and leaching of the additive decreased to 2% and hydrophilicity improved to 22%. The pore size and porosity of NCs were also enhanced and rejection rate was achieved in the establish dialysis range (<60 kDa). The antifouling studies had shown that NCs membrane exhibited 30% less adhesion of protein with 80% flux recovery ratio. The blood compatibility assessment disclosed that NCs based membranes showed prolonged thrombin and prothrombin clotting times, lessened production of fibrinogen cluster, and greatly suppressed adhesion of blood plasma than a pristine PES membrane. The results also unveiled that PVP-k30/NCs improved the surface properties of the membrane and the urea and creatinine removal increased to 72% and 75% than pure PES membranes. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 107A: 513-525, 2019.
    Matched MeSH terms: Renal Dialysis/instrumentation*
  17. Norhayati Ibrahim, Norella Kong Chiew-Thong, Asmawati Desa, Rozmi Ismail
    Sains Malaysiana, 2015;44:599-605.
    This cross-sectional study examined the influence of illness perception of health-related quality of life (HRQoL) in end
    stage renal disease (ESRD) patients on either hemodialysis (HD) or continuous ambulatory peritoneal dialysis (CAPD).
    The Short Form-36 (SF-36) was used to measure HRQoL which comprised the Physical Component Summary (PCS) and
    Mental Component Summary (MCS). Illness perception was evaluated using Revised Illness Perception Questionnaire
    (IPQ-R). Both questionnaires were administered on 183 HD and 93 CAPD patients. The results showed that almost all
    HRQoL subscales except physical functioning and bodily pain were found to be significantly different between HD and
    CAPD patients. There are significant correlations between most components of illness perception with HRQoL. Significant
    illness perception predictors of PCS among HD patients were time line, consequences, cyclical and identity, whereas on
    CAPD patients were time line, illness coherence, emotional, cyclical and identity. Significant illness perception predictors
    of MCS among HD patients included time line, cyclical and identity and only time line was significant predictor of MCS on
    CAPD patients. These should be considered when developing intervention programmes to improve their HRQoL.
    Matched MeSH terms: Renal Dialysis; Peritoneal Dialysis, Continuous Ambulatory
  18. Lim TS, Thong KM
    Pak J Med Sci, 2016 11 25;32(5):1302-1304.
    PMID: 27882041 DOI: 10.12669%2Fpjms.325.11096
    Pleural effusion or hydrothorax is a relatively rare but well-recognized complication associated with peritoneal dialysis (PD). We describe the successful long term resolution of a patient who developed pleural effusions after starting continuous ambulatory peritoneal dialysis (CAPD), by altering the PD prescription to normal volume daytime ambulatory peritoneal dialysis (DAPD) transiently before resuming the usual CAPD exchanges four months later. After 8 years of follow up, there is no sign of recurrence of the effusion. Normal volume DAPD present as an attractive alternative and cheap method for resolution of pleura-peritoneal fistula.
    Matched MeSH terms: Peritoneal Dialysis; Peritoneal Dialysis, Continuous Ambulatory
  19. Shahar S, Arimuthu DA, Mazlan SA
    BMC Nephrol, 2022 Nov 08;23(1):360.
    PMID: 36348388 DOI: 10.1186/s12882-022-02980-8
    BACKGROUND: Carbapenem-induced neurotoxicity is an unusual side effect, with seizure being the most commonly reported symptom. Among the carbapenems, imipenem-cilastin is classically associated with the most severe neurotoxicity side effects. Carbapenem is mainly excreted by the kidney and its half-life is significantly increased in patients with chronic kidney disease (CKD). Therefore, dose adjustment is necessary in such patients. Ertapenem-associated neurotoxicity is increasingly being reported in CKD patients, but rarely seen in patients with recommended dose adjustment.

    CASE PRESENTATION: We report a case of a 56-year-old male patient with chronic kidney disease 5 on dialysis(CKD 5D). The patient presented with a history of fever, chills and rigours during a session of haemodialysis (HD). He was diagnosed with Enterobacter cloacae catheter-related blood stream infection and was started on ertapenem. After 13 days of ertapenem, he experienced an acute confusional state and progressed to having auditory and visual hallucinations. His blood investigations and imaging results revealed no other alternative diagnosis. Hence a diagnosis of ertapenem-induced neurotoxicity was made. He had complete resolution of symptoms after 10 days' discontinuation of ertapenem.

    CONCLUSION: Our case draws attention to the risk of potentially serious toxicity of the central nervous system in HD patients who receive the current recommended dose of ertapenem. It also highlights that renal dosing in CKD 5D patients' needs to be clinically studied to ensure antibiotic safety.

    Matched MeSH terms: Renal Dialysis/adverse effects
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links