Displaying publications 41 - 60 of 191 in total

Abstract:
Sort:
  1. Sembulingam K, Sembulingam P, Namasivayam A
    Indian J Med Sci, 2003 Nov;57(11):487-92.
    PMID: 14646156
    Effect of various stressor agents on the adrenergic system in brain had been studied extensively. However, reports on the effect of stress on various parameters of central cholinergic system are scanty. And very little is known about the effect of noise stress on the cholinergic system in brain. Hence, it was decided to elucidate the effect of acute noise stress on the activity of the enzyme acetylcholinesterase in discrete areas of brain in albino rats. Male albino rats of Wistar strain were subjected to acute noise stress for 30 minutes. The noise of pure sine wave tone was produced by using a function generator and was amplified. The frequency of noise generated was 1 kHz and the intensity was set at 100 dB. The total acetylcholinesterase activity was determined in the tissues of cerebral cortex, corpus striatum, hypothalamus and hippocampus of brain in these rats. The enzyme activity was estimated by colorimetric method using acetylthiocholine iodide as the substrate. The values were compared with the enzyme activity in the control rats. The activity of the enzyme increased significantly in all the four regions of the brain in rats after exposure to noise stress for 30 minutes. The results of the study indicate that the exposure to acute noise stress could modulate the cholinergic system in these areas of brain in rat.
    Matched MeSH terms: Noise/adverse effects*
  2. Sayed IS, Ismail SS
    Int J Biomed Imaging, 2020;2020:9239753.
    PMID: 32308670 DOI: 10.1155/2020/9239753
    In single photon emission computed tomography (SPECT) imaging, the choice of a suitable filter and its parameters for noise reduction purposes is a big challenge. Adverse effects on image quality arise if an improper filter is selected. Filtered back projection (FBP) is the most popular technique for image reconstruction in SPECT. With this technique, different types of reconstruction filters are used, such as the Butterworth and the Hamming. In this study, the effects on the quality of reconstructed images of the Butterworth filter were compared with the ones of the Hamming filter. A Philips ADAC forte gamma camera was used. A low-energy, high-resolution collimator was installed on the gamma camera. SPECT data were acquired by scanning a phantom with an insert composed of hot and cold regions. A Technetium-99m radioactive solution was homogenously mixed into the phantom. Furthermore, a symmetrical energy window (20%) centered at 140 keV was adjusted. Images were reconstructed by the FBP method. Various cutoff frequency values, namely, 0.35, 0.40, 0.45, and 0.50 cycles/cm, were selected for both filters, whereas for the Butterworth filter, the order was set at 7. Images of hot and cold regions were analyzed in terms of detectability, contrast, and signal-to-noise ratio (SNR). The findings of our study indicate that the Butterworth filter was able to expose more hot and cold regions in reconstructed images. In addition, higher contrast values were recorded, as compared to the Hamming filter. However, with the Butterworth filter, the decrease in SNR for both types of regions with the increase in cutoff frequency as compared to the Hamming filter was obtained. Overall, the Butterworth filter under investigation provided superior results than the Hamming filter. Effects of both filters on the quality of hot and cold region images varied with the change in cutoff frequency.
    Matched MeSH terms: Signal-To-Noise Ratio
  3. Sayapathi BS, Su AT, Koh D
    J Occup Health, 2014;56(1):1-11.
    PMID: 24270928
    OBJECTIVES: A systematic review was conducted to identify the effectiveness of different permissible exposure limits in preserving the hearing threshold level. This review compared the limits of the US National Institute of Occupational Safety and Health with those of the US Occupational Safety and Health Administration. The prevalence of occupational noise-induced hearing loss is on an increasing trend globally. This review was performed to reduce the prevalence of noise-induced hearing loss.

    METHODS: We searched 3 major databases, i.e., PubMed, Embase and Lippincott Williams & Wilkins Journals@Ovid, for studies published up until 1May 2013 without language restrictions. All study designs were included in this review. The studies were identified and retrieved by two independent authors.

    RESULTS: Of 118 titles scanned, 14 duplicates were removed, and a total of 13 abstracts from all three databases were identified for full-text retrieval. From the full text, eight articles met the inclusion criteria for this systematic review. These articles showed acceptable quality based on our scoring system. Most of the studies indicated that temporary threshold shifts were much lower when subjects were exposed to a noise level of 85 dBA or lower.

    CONCLUSIONS: There were more threshold shifts in subjects adopting 90 dBA compared with 85 dBA. These temporary threshold shifts may progress to permanent shifts over time. Action curtailing noise exposure among employees would be taken earlier on adoption of 85 dBA as the permissible exposure limit, and hence prevalence of noise-induced hearing loss may be reduced.

    Matched MeSH terms: Hearing Loss, Noise-Induced/epidemiology; Hearing Loss, Noise-Induced/prevention & control*; Noise, Occupational/adverse effects*; Noise, Occupational/prevention & control
  4. Salleh SH, Hussain HS, Swee TT, Ting CM, Noor AM, Pipatsart S, et al.
    Int J Nanomedicine, 2012;7:2873-81.
    PMID: 22745550 DOI: 10.2147/IJN.S32315
    Auscultation of the heart is accompanied by both electrical activity and sound. Heart auscultation provides clues to diagnose many cardiac abnormalities. Unfortunately, detection of relevant symptoms and diagnosis based on heart sound through a stethoscope is difficult. The reason GPs find this difficult is that the heart sounds are of short duration and separated from one another by less than 30 ms. In addition, the cost of false positives constitutes wasted time and emotional anxiety for both patient and GP. Many heart diseases cause changes in heart sound, waveform, and additional murmurs before other signs and symptoms appear. Heart-sound auscultation is the primary test conducted by GPs. These sounds are generated primarily by turbulent flow of blood in the heart. Analysis of heart sounds requires a quiet environment with minimum ambient noise. In order to address such issues, the technique of denoising and estimating the biomedical heart signal is proposed in this investigation. Normally, the performance of the filter naturally depends on prior information related to the statistical properties of the signal and the background noise. This paper proposes Kalman filtering for denoising statistical heart sound. The cycles of heart sounds are certain to follow first-order Gauss-Markov process. These cycles are observed with additional noise for the given measurement. The model is formulated into state-space form to enable use of a Kalman filter to estimate the clean cycles of heart sounds. The estimates obtained by Kalman filtering are optimal in mean squared sense.
    Matched MeSH terms: Signal-To-Noise Ratio
  5. Salina H, Abdullah A, Mukari SZ, Azmi MT
    Eur Arch Otorhinolaryngol, 2010 Apr;267(4):495-9.
    PMID: 19727788 DOI: 10.1007/s00405-009-1080-y
    Transient-evoked otoacoustic emission (TEOAE) is a well-established screening tool for universal newborn hearing screening. The aims of this study are to measure the effects of background noise on recording of TEOAE and the duration required to complete the test at various noise levels. This study is a prospective study from June 2006 until May 2007. The study population were newborns from postnatal wards who were delivered at term pregnancy. Newborns who were more than 8-h old and passed a hearing screening testing using screening auditory brainstem response (SABRe) were further tested with TEOAE in four different test environments [isolation room in the ward during non-peak hour (E1), isolation room in the ward during peak hour (E2), maternal bedside in the ward during non-peak hour (E3) and maternal bedside in the ward during peak hour (E4)]. This study showed that test environment significantly influenced the time required to complete testing in both ears with F [534.23] = 0.945; P < 0.001 on the right ear and F [636.54] = 0.954; P < 0.001 on the left. Our study revealed that TEOAE testing was efficient in defining the presence of normal hearing in our postnatal wards at maternal bedside during non-peak hour with a specificity of 96.8%. Our study concludes that background noise levels for acceptable and accurate TEOAE recording in newborns should not exceed 65 dB A. In addition, when using TEOAE assessment in noisy environments, the time taken to obtain accurate results will greatly increase.
    Matched MeSH terms: Noise*
  6. Said MA, Musarudin M, Zulkaffli NF
    Ann Nucl Med, 2020 Dec;34(12):884-891.
    PMID: 33141408 DOI: 10.1007/s12149-020-01543-x
    OBJECTIVE: 18F is the most extensively used radioisotope in current clinical practices of PET imaging. This selection is based on the several criteria of pure PET radioisotopes with an optimum half-life, and low positron energy that contributes to a smaller positron range. In addition to 18F, other radioisotopes such as 68Ga and 124I are currently gained much attention with the increase in interest in new PET tracers entering the clinical trials. This study aims to determine the minimal scan time per bed position (Tmin) for the 124I and 68Ga based on the quantitative differences in PET imaging of 68Ga and 124I relative to 18F.

    METHODS: The European Association of Nuclear Medicine (EANM) procedure guidelines version 2.0 for FDG-PET tumor imaging has adhered for this purpose. A NEMA2012/IEC2008 phantom was filled with tumor to background ratio of 10:1 with the activity concentration of 30 kBq/ml ± 10 and 3 kBq/ml ± 10% for each radioisotope. The phantom was scanned using different acquisition times per bed position (1, 5, 7, 10 and 15 min) to determine the Tmin. The definition of Tmin was performed using an image coefficient of variations (COV) of 15%.

    RESULTS: Tmin obtained for 18F, 68Ga and 124I were 3.08, 3.24 and 32.93 min, respectively. Quantitative analyses among 18F, 68Ga and 124I images were performed. Signal-to-noise ratio (SNR), contrast recovery coefficients (CRC), and visibility (VH) are the image quality parameters analysed in this study. Generally, 68Ga and 18F gave better image quality as compared to 124I for all the parameters studied.

    CONCLUSION: We have defined Tmin for 18F, 68Ga and 124I SPECT CT imaging based on NEMA2012/IEC2008 phantom imaging. Despite the long scanning time suggested by Tmin, improvement in the image quality is acquired especially for 124I. In clinical practice, the long acquisition time, nevertheless, may cause patient discomfort and motion artifact.

    Matched MeSH terms: Signal-To-Noise Ratio
  7. Saffree Jeffree M, Ismail N, Awang Lukman K
    J Occup Health, 2016 Sep 30;58(5):434-443.
    PMID: 27488035
    INTRODUCTION: Hearing impairment remains the main occupational health problem in the manufacturing industry, and its contributing factors have not been well controlled.

    METHODS: Unmatched case control and comparative studies were carried out among fertilizer factory workers in Sarawak with the aim of determining contributing factors for hearing impairment. Respondents consisted of 49 cases that were diagnosed from 2005 to 2008 with 98 controls from the same work places. Chi-square test and Mann-Whitney test were used in a univariate analysis to determine the association between hearing impairment and the contributing risks being studied.

    RESULTS: The results of the univariate analysis showed that hearing impairment was significantly (p<0.05) associated with older age, lower education level, high smoking dose, high occupational daily noise dose, longer duration of service, infrequent used of hearing protection device (HPD), and low perception of sound on HPD usage. Multivariate logistic regression of hearing impairment after controlling for age found the following five variables: occupational daily noise dose ≥50% (OR 3.48, 95% CI 1.36-8.89), ≥15 years of services (OR 2.92, 95% CI 1.16-7.33), infrequent use of HPD (OR 2.79, 95% CI 1.15-6.77), low perception of sound on HPD (POR 2.77, 95% CI 1.09-6.97), and smoking more than 20 packs per year (OR 4.71, 95% CI 1.13-19.68).

    DISCUSSION: In conclusion, high occupational noise exposure level, longer duration of service, low perception of sound on HPD, infrequent used of HPD, and smoking more than 20 packs per year were the contributing factors to hearing impairment, and appropriate intervention measures should be proposed and taken into considerations.

    Matched MeSH terms: Hearing Loss, Noise-Induced/etiology*; Hearing Loss, Noise-Induced/prevention & control; Noise, Occupational/adverse effects*
  8. Safara F, Doraisamy S, Azman A, Jantan A, Abdullah Ramaiah AR
    Comput Biol Med, 2013 Oct;43(10):1407-14.
    PMID: 24034732 DOI: 10.1016/j.compbiomed.2013.06.016
    Wavelet packet transform decomposes a signal into a set of orthonormal bases (nodes) and provides opportunities to select an appropriate set of these bases for feature extraction. In this paper, multi-level basis selection (MLBS) is proposed to preserve the most informative bases of a wavelet packet decomposition tree through removing less informative bases by applying three exclusion criteria: frequency range, noise frequency, and energy threshold. MLBS achieved an accuracy of 97.56% for classifying normal heart sound, aortic stenosis, mitral regurgitation, and aortic regurgitation. MLBS is a promising basis selection to be suggested for signals with a small range of frequencies.
    Matched MeSH terms: Signal-To-Noise Ratio
  9. Rus RM, Daud A, Musa KI, Naing L
    Malays J Med Sci, 2008 Oct;15(4):28-34.
    PMID: 22589635
    The purpose of this study was to determine the sawmill workers' knowledge, attitude and practice (KAP) in relation to noise-induced hearing loss (NIHL). A cross-sectional study was conducted involving 83 workers from 3 factories in Kota Bharu, Kelantan. Questionnaires were distributed to obtain the socio-demography, knowledge, attitude and practice level in relation to noise-induced hearing loss (NIHL). The weak areas identified in the knowledge section were treatment aspects (15.5%), signs and symptoms of NIHL (20.2%) and risk factors (31%). As for attitude; the prevention aspects were the lowest (25.3%), followed by risk taking attitude (26.2%), and causes of hearing loss (42.1%). Overall, the practice was not encouraging at all. It is important to have an education program to raise workers' awareness and to improve their attitude and practices towards noise-induced hearing loss.
    Matched MeSH terms: Hearing Loss, Noise-Induced
  10. Razman, M.R., Naing, L., Kamarul, I.M.
    MyJurnal
    Introduction: Exposure to excessive noise is the major avoidable cause of permanent hearing impairment. Sawmill is one of the workplaces where workers are exposed to hazardous noise level. This study was conducted to determine the reliability and validity of noise-induced hearing loss questionnaire among sawmill workers. Materials and Methods: This cross sectional study was conducted in March 2007 among 35 consented sawmill workers. A total of 40 items; 10 items for knowledge (8 areas), 20 items for attitude (7 areas) and 10 items for practice (2 areas) were assessed. Statistical analysis for reliability analysis was test by internal consistency and construct validity by exploratory factor analysis using principal components and Varimax rotation method. Results: Cronbach’s alpha coeffi cients were acceptable for attitude (0.90) and practice
    (0.75). However, it was low for knowledge (0.67). Exploratory factor analysis showed three meaningful exploratory factors that could explain the three dimensions in the questionnaire. Conclusion: The results of the validation study suggested that the noise-induced hearing loss questionnaire is reliable and valid tool for assessing knowledge, attitude and practice among sawmill workers.
    Matched MeSH terms: Hearing Loss, Noise-Induced; Noise
  11. Rashid, A.S., Khatun, S., Ali, B.M., Khazani, A.M.
    ASM Science Journal, 2008;2(1):13-22.
    MyJurnal
    An analysis of the power spectral density of ultra-wideband (UWB) signals is presented in order to evaluate the effects of cumulative interference from multiple UWB devices on victim narrowband systems in their overlay bands like WiFi (i.e. IEEE802.11a) and 3rdG systems (Universal mobile telecommunications system/wideband code division multiple access). In this paper, the performances are studied through the bit-error-rate as a function of signal-to-noise ratio as well as signal-to-interference power ratio using computer simulation and exploiting the realistic channel model (i.e. modified Saleh-Valenzuela model). Several modifications of a generic Gaussian pulse waveform with lengths in the order of nanoseconds were used to generate UWB spectra. Different kinds of pulse modulation (i.e. antipodal and orthogonal) schemes were also taken into account.
    Matched MeSH terms: Signal-To-Noise Ratio
  12. Rahma MS, Mustafa BE, Razali A, Shamsuddin N, Althunibat OY
    Noise Health, 2013 Nov-Dec;15(67):375-8.
    PMID: 24231415 DOI: 10.4103/1463-1741.121223
    Several epidemiologic studies have reported that exposure to noise is associated with cardiovascular disease. The increased body weight is often associated with metabolic as well as increased blood pressure. The aim of this study is to investigate the correlation between the elevation of blood pressure and serum leptin hormones due to the effects of noise in the work place. A total of 80 volunteer males where included in this study with an age range between of 20 and 45 years, they were divided in two groups equally, the 1 st group were exposed to noise in the workplace while the 2 nd group were not. The individual noise exposure was determined by using a sound level meter. The range of noise was 80-100 dBA. Body Mass Index was also taken for each individual by a standard measure, blood pressure was measured by OMRON sphygmomanometer and serum leptin was measured through venous blood sample analysis enzyme linked immunosorbent assay. Spearman rank order correlation was used to examine the correlations between Blood pressure value (Systolic, Diastolic) and Leptin. All the relationships between parameters showed a positive correlation. Systolic and diastolic blood pressure values had a significant correlation to leptin hormone level in comparison to the control. There was a significant relation between leptin and blood pressure. leptin effects on the sympathetic nervous system may provide a partial explanation. Therefore, Leptin might have diverse cardiovascular actions.
    Matched MeSH terms: Noise, Occupational/adverse effects*
  13. Quar TK, Ching TY, Newall P, Sharma M
    Int J Audiol, 2013 May;52(5):322-32.
    PMID: 23570290 DOI: 10.3109/14992027.2012.755740
    The study aims to compare the performance of hearing aids fitted according to the NAL-NL1 and DSL v5 prescriptive procedure for children.
    Matched MeSH terms: Noise/adverse effects
  14. Quar TK, Mukari SZ, Abdul Wahab NA, Abdul Razak R, Omar M, Maamor N
    Int J Audiol, 2008 Jun;47(6):379-80.
    PMID: 18569117 DOI: 10.1080/14992020801886796
    Matched MeSH terms: Noise*
  15. Quar TK, Soli SD, Chan YF, Ishak WS, Abdul Wahat NH
    Int J Audiol, 2017 02;56(2):92-98.
    PMID: 27686009 DOI: 10.1080/14992027.2016.1210828
    OBJECTIVE: This study was conducted to evaluate the speech perception of Malaysian Chinese adults using the Taiwanese Mandarin HINT (MHINT-T) and the Malay HINT (MyHINT).

    DESIGN: The MHINT-T and the MyHINT were presented in quiet and noise (front, right and left) conditions under headphones. Results for the two tests were compared with each other and with the norms for each test.

    STUDY SAMPLE: Malaysian Chinese native speakers of Mandarin (N = 58), 18-31 years of age with normal hearing.

    RESULTS: On average, subjects demonstrated poorer speech perception ability than the normative samples for these tests. Repeated measures ANOVA showed that speech reception thresholds (SRTs) were slightly poorer on the MHINT-T than on the MyHINT for all test conditions. However, normalized SRTs were poorer by 0.6 standard deviations for MyHINT as compared with MHINT-T.

    CONCLUSIONS: MyHINT and MHINT-T can be used as norm-referenced speech perception measures for Mandarin-speaking Chinese in Malaysia.

    Matched MeSH terms: Noise/adverse effects*
  16. Priyadarshani N, Marsland S, Castro I, Punchihewa A
    PLoS One, 2016;11(1):e0146790.
    PMID: 26812391 DOI: 10.1371/journal.pone.0146790
    Automatic recording of birdsong is becoming the preferred way to monitor and quantify bird populations worldwide. Programmable recorders allow recordings to be obtained at all times of day and year for extended periods of time. Consequently, there is a critical need for robust automated birdsong recognition. One prominent obstacle to achieving this is low signal to noise ratio in unattended recordings. Field recordings are often very noisy: birdsong is only one component in a recording, which also includes noise from the environment (such as wind and rain), other animals (including insects), and human-related activities, as well as noise from the recorder itself. We describe a method of denoising using a combination of the wavelet packet decomposition and band-pass or low-pass filtering, and present experiments that demonstrate an order of magnitude improvement in noise reduction over natural noisy bird recordings.
    Matched MeSH terms: Noise; Signal-To-Noise Ratio
  17. Othman E, Yusoff AN, Mohamad M, Abdul Manan H, Abd Hamid AI, Giampietro V
    Exp Brain Res, 2020 Apr;238(4):945-956.
    PMID: 32179941 DOI: 10.1007/s00221-020-05765-3
    The present study examined the impact of white noise on word recall performance and brain activity in 40 healthy adolescents, split in two groups (normal and low) depending on their auditory working memory capacity (AWMC). Using functional magnetic resonance imaging, participants performed a backward recall task under four different signal-to-noise ratio (SNR) conditions: 15, 10, 5, and 0-dB SNR. Behaviorally, normal AWMC individuals scored significantly higher than low AWMC individuals across noise levels. Whole-brain analyses showed brain activation not to be statistically different between groups across noise levels. In the normal group, a significant positive relationship was found between performance and number of activated voxels in the right superior frontal gyrus. In the low group, significant positive correlations were found between performance and number of activated voxels in left superior frontal gyrus, left inferior frontal gyrus, and left anterior cingulate cortex. These findings suggest that the strategic structure involved in the enhancement of AWM performance may differ in normal and low AWMC individuals.
    Matched MeSH terms: Noise
  18. Nur Azien Yazid, Kamilah Abdullah, Suhaila Abd Halim
    ESTEEM Academic Journal, 2019;15(1):44-55.
    MyJurnal
    Image watermarking embeds identifying information in an image in such a manner that it cannot easily be removed. For the past several years, image digital watermarking has become a necessary element used for hiding secret image and enabling secured communication such as
    privacy, confidentiality, authentication and data integrity. Although numerous watermarking schemes are present in grayscale images, the present work focuses on the RGB color image. This study proposed a new hybrid method that would satisfy the essential needs of modern image watermarking. The color image watermarking is based on the 2D Discrete Cosine Transform and Elgamal cryptosystem. The 2D Discrete Cosine Transform depends on the matrix products, while the Elgamal cryptosystem depends on the discrete logarithm problem. The cryptosystem is combined with existing Arnold transform in watermarking algorithm to enhance the security of secret image. Value of Peak Signal to Noise Ratio was taken as performance evaluation parameters. On the whole, the performance evaluation shows that combining the two algorithms improved the performance of image watermarking.
    Matched MeSH terms: Signal-To-Noise Ratio
  19. Norhafizan Ahmad, Raja Ariffin Raja Ghazilla, Muhammad Zikril Hakim Md Azizi
    MyJurnal
    Brain Computer Interfaces (BCI) provide a vast possibility in enabling the brain to communicate directly with the computer, hence providing an alternative in controlling the machines without much effort. In fields of rehabilitations robotics, the applications of an exoskeletons in assisting a spinal cord injured (SCI) patients were growing. Steady state visually evoked potentials (SSVEP) based BCIs that utilizes the human visual reactions to the constant flickered stimulus quickly showed its potentials among the BCIs used in rehabilitations devices because of its advantages such as a higher immunity to noises and artefacts and also its robustness compared to other BCIs. Rehabilitation exoskeletons demands an approach that are more user friendly and the aspects of control scheme and mechanical parts that are more focused on assisting the patients in rehabilitations and providing a SCI patients an alternatives to explore their surroundings in a more intuitive ways. This paper highlights the current development trends in SSVEP based BCIs for rehabilitation exoskeletons and proposed the potential research scopes in the future that can improve the effectiveness, and its potential applications in rehabilitations.
    Matched MeSH terms: Noise
  20. Norfarah Nadia Ismail, Joh SH, Raja Hassanul Musa Raja Ahmad
    Sains Malaysiana, 2012;41:1621-1627.
    A beamformer in seismology is a signal receptor with a series of geophones, in which a beam of elastic waves is formed like a light beam by adjusting signal delays at individual geophones. Recently, beamforming has extended its applications to surface-wave measurement. In surface-wave measurement, beamforming provides unique advantages over other surface-wave methods, such as full automation in data analysis as well as directional signal reception to minimize scattered noise and multiple reflections in signals. However, certain defects depreciate the value of beamforming in terms of its practicality and feasibility. These include the requirement of having many receivers and the loss of small wavelength data due to spatial aliasing. It leads to insensitivity in identification of lateral variability, which creates the problem of having to smooth out geologic features and complexities like folding, faults and fractures. In this paper, advances in the refinement of beamforming were described on two counts: improvement of sensitivity in identification of lateral variability and recovery of aliased wave numbers, which enables evaluation of shallow material. On the passage to refinement, synthetic waveforms for typical layering systems were generated to figure out characteristics of beamformer velocities in comparison with SASW velocities and theoretical normal-mode velocities.
    Matched MeSH terms: Noise
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links