Displaying publications 41 - 60 of 82 in total

Abstract:
Sort:
  1. Haque S, Alam MK, Khamis MF
    BMC Pediatr, 2017 May 06;17(1):119.
    PMID: 28477625 DOI: 10.1186/s12887-017-0870-4
    BACKGROUND: Cleft lip and palate (CLP) is one of the most common birth defects. Multiple factors are believed to be responsible for an unfavorable dental arch relationship in CLP. Facial growth (maxillary) retardation, which results in class III malocclusion, is the primary challenge that CLP patients face. Phenotype factors and postnatal treatment factors influence treatment outcomes in unilateral cleft lip and palate (UCLP) children, which has led to a great diversity in protocols and surgical techniques by various cleft groups worldwide. The aim of this study was to illustrate the dental arch relationship (DAR) and palatal morphology (PM) of UCLP in Bangladeshi children and to explore the various factors that are responsible for poor DAR and PM.

    METHODS: Dental models of 84 subjects were taken before orthodontic treatment and alveolar bone grafting. The mean age was 7.69 (SD 2.46) years. The DAR and PM were assessed blindly by five raters using the EUROCRAN index (EI). Kappa statistics was used to evaluate the intra- and inter-examiner agreement, chi square was used to assess the associations, and logistic regression analysis was used to explore the responsible factors that affect DAR and PM.

    RESULTS: The mean EUROCRAN scores were 2.44 and 1.93 for DAR and PM, respectively. Intra- and inter-examiner agreement was moderate to very good. Using crude and stepwise backward regression analyses, significant associations were found between the modified Millard technique (P = 0.047, P = 0.034 respectively) of cheiloplasty and unfavorable DAR. Complete UCLP (P = 0.017) was also significantly correlated with unfavorable DAR. The PM showed a significant association with the type of cleft, type of cheiloplasty and type of palatoplasty.

    CONCLUSION: This multivariate study determined that the complete type of UCLP and the modified Millard technique of cheiloplasty had significantly unfavorable effects on both the DAR and PM.

    Matched MeSH terms: Observer Variation
  2. Toh TH, Lim BC, Bujang MAB, Haniff J, Wong SC, Abdullah MR
    Pediatr Int, 2017 Aug;59(8):861-868.
    PMID: 28510345 DOI: 10.1111/ped.13325
    BACKGROUND: We examined the parental perception and accuracy of the Mandarin translation of the Parents' Evaluation of Developmental Status, a screening questionnaire for parent concerns about children's various developmental skills.

    METHODS: The questionnaire was translated into Mandarin. Upon enrollment, caregivers completed the Mandarin PEDS and answered four questions about its acceptability and usefulness, and its ease of understanding and completion. The Mandarin PEDS was independently evaluated by a pediatrician and a community nurse, and classified as high risk (≥two predictive concerns), medium risk (one predictive concern), low risk (any non-predictive concerns) or no risk (if no concern) for developmental delays. The caregivers repeated Mandarin PEDS at a 2 week interval for test-retest reliability, while the children underwent testing for accuracy using a developmental assessment test.

    RESULTS: The majority (≥85%) of the 73 caregivers perceived the Mandarin PEDS as acceptable and useful, as well as easy to understand and complete. Fifteen (20.5%) and 24 responses (33.9%) were classified as high and moderate risk, respectively. The test-retest and inter-rater reliabilities were excellent, with an intra-class correlation coefficient of 0.812 (95% CI: 0.701-0.881, P 

    Matched MeSH terms: Observer Variation
  3. Leong CO, Lim E, Tan LK, Abdul Aziz YF, Sridhar GS, Socrates D, et al.
    Magn Reson Med, 2019 02;81(2):1385-1398.
    PMID: 30230606 DOI: 10.1002/mrm.27486
    PURPOSE: To evaluate a 2D-4D registration-cum-segmentation framework for the delineation of left ventricle (LV) in late gadolinium enhanced (LGE) MRI and for the localization of infarcts in patient-specific 3D LV models.

    METHODS: A 3-step framework was proposed, consisting of: (1) 3D LV model reconstruction from motion-corrected 4D cine-MRI; (2) Registration of 2D LGE-MRI with 4D cine-MRI; (3) LV contour extraction from the intersection of LGE slices with the LV model. The framework was evaluated against cardiac MRI data from 27 patients scanned within 6 months after acute myocardial infarction. We compared the use of local Pearson's correlation (LPC) and normalized mutual information (NMI) as similarity measures for the registration. The use of 2 and 6 long-axis (LA) cine-MRI scans was also compared. The accuracy of the framework was evaluated using manual segmentation, and the interobserver variability of the scar volume derived from the segmented LV was determined using Bland-Altman analysis.

    RESULTS: LPC outperformed NMI as a similarity measure for the proposed framework using 6 LA scans, with Hausdorrf distance (HD) of 1.19 ± 0.53 mm versus 1.51 ± 2.01 mm (endocardial) and 1.21 ± 0.48 mm versus 1.46 ± 1.78 mm (epicardial), respectively. Segmentation using 2 LA scans was comparable to 6 LA scans with a HD of 1.23 ± 0.70 mm (endocardial) and 1.25 ± 0.74 mm (epicardial). The framework yielded a lower interobserver variability in scar volumes compared with manual segmentation.

    CONCLUSION: The framework showed high accuracy and robustness in delineating LV in LGE-MRI and allowed for bidirectional mapping of information between LGE- and cine-MRI scans, crucial in personalized model studies for treatment planning.

    Matched MeSH terms: Observer Variation
  4. Mohd Norsuddin N, Mello-Thoms C, Reed W, Lewis S
    Asian Pac J Cancer Prev, 2019 Feb 26;20(2):537-543.
    PMID: 30803217
    Rationale and objectives: Target recall rates are often used as a performance indicator in mammography screening
    programs with the intention of reducing false positive decisions, over diagnosis and anxiety for participants. However,
    the relationship between target recall rates and cancer detection is unclear, especially when readers are directed to
    adhere to a predetermined rate. The purpose of this study was to explore the effect of setting different recall rates on
    radiologist’s performance. Materials and Methods: Institutional ethics approval was granted and informed consent
    was obtained from each participating radiologist. Five experienced breast imaging radiologists read a single test set
    of 200 mammographic cases (20 abnormal and 180 normal). The radiologists were asked to identify each case that
    they required to be recalled in three different recall conditions; free recall, 15% and 10% and mark the location of any
    suspicious lesions. Results: Wide variability in recall rates was observed when reading at free recall, ranging from
    18.5% to 34.0%. Readers demonstrated significantly reduced performance when reading at prescribed recall rates,
    with lower sensitivity (H=12.891, P=0.002), case location sensitivity (H=12.512, P=0.002) and ROC AUC (H=11.601,
    P=0.003) albeit with an increased specificity (H=12.704, P=0.002). However, no significant changes were evident in
    lesion location sensitivity (H=1.982, P=0.371) and JAFROC FOM (H=1.820, P=0.403). Conclusion: In this laboratory
    study, reducing the number of recalled cases to 10% significantly reduced radiologists’ performance with lower detection
    sensitivity, although a significant improvement in specificity was observed.
    Matched MeSH terms: Observer Variation
  5. Wee LK, Chai HY, Samsury SR, Mujamil NF, Supriyanto E
    An Acad Bras Cienc, 2012 Dec;84(4):1157-68.
    PMID: 23207710
    Current two-dimensional (2D) ultrasonic marker measurements are inherent with intra- and inter-observer variability limitations. The objective of this paper is to investigate the performance of conventional 2D ultrasonic marker measurements and proposed programmable interactive three-dimensional (3D) marker evaluation. This is essentially important to analyze that the measurement on 3D volumetric measurement possesses higher impact and reproducibility vis-à-vis 2D measurement. Twenty three cases of prenatal ultrasound examination were obtained from collaborating hospital after Ethical Committee's approval. The measured 2D ultrasonic marker is Nuchal Translucency or commonly abbreviated as NT. Descriptive analysis of both 2D and 3D ultrasound measurement were calculated. Three trial measurements were taken for each method. Both data were tested with One-Sample Kolmogorov-Smirnov Test and results indicate that markers measurements were distributed normally with significant parametric values at 0.621 and 0.596 respectively. Computed mean and standard deviation for both measurement methods are 1.4495 ± 0.46490 (2D) and 1.3561 ± 0.50994 (3D). ANOVA test shows that computerized 3D measurements were found to be insignificantly different from the mean of conventional 2D at the significance level of 0.05. With Pearson's correlation coefficient value or R = 0.861, the result proves strong positive linear correlation between 2D and 3D ultrasonic measurements. Reproducibility and accuracy of 3D ultrasound in NT measurement was significantly increased compared with 2D B-mode ultrasound prenatal assessment. 3D reconstructed imaging has higher clinical values compare to 2D ultrasound images with less diagnostics information.
    Matched MeSH terms: Observer Variation
  6. Hassan NB, Choudhury SR, Naing L, Conroy RM, Rahman AR
    Asia Pac J Public Health, 2007;19(3):45-51.
    PMID: 18333302 DOI: 10.1177/101053950701900308
    The objective of the study is to translate the Rose Questionnaire (RQ) into a Bahasa Melayu version and adapt it cross-culturally, and to measure its inter-rater and intrarater reliability. This cross sectional study was conducted in the respondents' homes or workplaces in Kelantan, Malaysia. One hundred respondents aged 30 and above with different socio-demographic status were interviewed for face validity. For each inter-rater and intra-rater reliability, a sample of 150 respondents was interviewed. Inter-rater and intra-rater reliabilities were assessed by Cohen's kappa. The overall inter-rater agreements by the five pair of interviewers at point one and two were 0.86, and intrarater reliability by the five interviewers on the seven-item questionnaire at poinone and two was 0.88, as measured by kappa coefficient. The translated Malay version of RQ demonstrated an almost perfect inter-rater and intra-rater reliability and further validation such as sensitivity and specificity analysis of this translated questionnaire is highly recommended.
    Matched MeSH terms: Observer Variation
  7. Annuar BR, Liew CK, Chin SP, Ong TK, Seyfarth MT, Chan WL, et al.
    Eur J Radiol, 2008 Jan;65(1):112-9.
    PMID: 17466480
    To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR).
    Matched MeSH terms: Observer Variation
  8. Ball V, Chiu CS, Lian YP, Lingeswaran L
    Physiother Theory Pract, 2018 Jan;34(1):54-57.
    PMID: 28816591 DOI: 10.1080/09593985.2017.1360423
    BACKGROUND: Newly qualified physiotherapists may be required to interpret an unreported chest X-ray (CXR) as part of their physiotherapy assessment in "on call" situations. Their interpretation may influence the patient management strategies they adopt. There is no research published which have tested the reliability of final year physiotherapy students in CXR interpretation.

    METHODS: Twenty-five final year physiotherapy students were asked to view and interpret the findings of six CXRs, together with a brief vignette, typical of a single commonly encountered diagnosis. Students were also asked if they had received additional CXR training on placement or had a desire to specialize in respiratory care.

    RESULTS: The CXR interpretations were scored as incorrect 0, partially correct 1 (abnormality detected but not able to diagnose or missed some detail) and 2 correct. Scores for each of the six CXRs were added to give a total score (out of 12). The median score was 3 out of 12, (range 0-9). Median scores were slightly higher at 4 out of 12 in those students with additional training or a desire to specialize (range 1-7), but this was not statistically significant (p = 0.43).

    CONCLUSIONS: Final year physiotherapy students were not able to reliably interpret CXRs. These findings were consistent with previous published research involving medical students. Therefore on graduation before starting "on call" duties it is recommended newly qualified physiotherapists receive additional training in CXR interpretation.

    Matched MeSH terms: Observer Variation
  9. Hassan T, Thiberville L, Hermant C, Lachkar S, Piton N, Guisier F, et al.
    PLoS One, 2017;12(12):e0189846.
    PMID: 29267317 DOI: 10.1371/journal.pone.0189846
    BACKGROUND: Malignant solitary pulmonary nodules (SPN) have become more prevalent, with upper lobes predilection. Probe-based confocal laser endomicroscopy (pCLE) provides in-vivo imaging of SPN. However, the stiffness of the 1mm confocal probe (AlveoFlex) causes difficult accessibility to the upper lobes. A thinner 600μm probe designed for bile duct exploration (CholangioFlex) has the potential to reach the upper lobes.

    OBJECTIVES: To examine the accessibility of malignant SPNs in all segments of the lungs using either the 0.6mm or 1.4 mm probe and to assess the quality and inter observer interpretation of SPN confocal imaging obtained from either miniprobes.

    METHODS: Radial(r)-EBUS was used to locate and sample the SPN. In-vivo pCLE analysis of the SPN was performed using either CholangioFlex (apical and posterior segments of the upper lobes) or AlveoFlex (other segments) introduced into the guide sheath before sampling. pCLE features were compared between the two probes.

    RESULTS: Fourty-eight patients with malignant SPN were included (NCT01931579). The diagnostic accuracy for lung cancer using r-EBUS coupled with pCLE imaging was 79.2%. All the SPNs were successfully explored with either one of the probes (19 and 29 subjects for CholangioFlex and AlveoFlex, respectively). A specific solid pattern in the SPN was found in 30 pCLE explorations. Comparison between the two probes found no differences in the axial fibers thickness, cell size and specific solid pattern in the nodules. Extra-alveolar microvessel size appeared larger using CholangioFlex suggesting less compression effect. The kappa test for interobserver agreement for the identification of solid pattern was 0.74 (p = 0.001).

    CONCLUSION: This study demonstrates that pCLE imaging of SPNs is achievable in all segments of both lungs using either the 0.6mm or 1.4mm miniprobe.

    Matched MeSH terms: Observer Variation
  10. Zabidin N, Mohamed AM, Zaharim A, Marizan Nor M, Rosli TI
    Int Orthod, 2018 03;16(1):133-143.
    PMID: 29478934 DOI: 10.1016/j.ortho.2018.01.009
    OBJECTIVES: To evaluate the relationship between human evaluation of the dental-arch form, to complete a mathematical analysis via two different methods in quantifying the arch form, and to establish agreement with the fourth-order polynomial equation.

    MATERIALS AND METHODS: This study included 64 sets of digitised maxilla and mandible dental casts obtained from a sample of dental arch with normal occlusion. For human evaluation, a convenient sample of orthodontic practitioners ranked the photo images of dental cast from the most tapered to the less tapered (square). In the mathematical analysis, dental arches were interpolated using the fourth-order polynomial equation with millimetric acetate paper and AutoCAD software. Finally, the relations between human evaluation and mathematical objective analyses were evaluated.

    RESULTS: Human evaluations were found to be generally in agreement, but only at the extremes of tapered and square arch forms; this indicated general human error and observer bias. The two methods used to plot the arch form were comparable.

    CONCLUSION: The use of fourth-order polynomial equation may be facilitative in obtaining a smooth curve, which can produce a template for individual arch that represents all potential tooth positions for the dental arch.

    Matched MeSH terms: Observer Variation
  11. Givehchi S, Safari MJ, Tan SK, Md Shah MNB, Sani FBM, Azman RR, et al.
    Phys Med, 2018 Jan;45:198-204.
    PMID: 29373248 DOI: 10.1016/j.ejmp.2017.09.137
    PURPOSE: Accurate determination of the bifurcation angle and correlation with plaque buildup may lead to the prediction of coronary artery disease (CAD). This work evaluates two techniques to measure bifurcation angles in 3D space using coronary computed tomography angiography (CCTA).

    MATERIALS AND METHODS: Nine phantoms were fabricated with different bifurcation angles ranging from 55.3° to 134.5°. General X-ray and CCTA were employed to acquire 2D and 3D images of the bifurcation phantoms, respectively. Multiplanar reformation (MPR) and volume rendering technique (VRT) were used to measure the bifurcation angle between the left anterior descending (LAD) and left circumflex arteries (LCx). The measured angles were compared with the true values to determine the accuracy of each measurement technique. Inter-observer variability was evaluated. The two techniques were further applied on 50 clinical CCTA cases to verify its clinical value.

    RESULTS: In the phantom setting, the mean absolute differences calculated between the true and measured angles by MPR and VRT were 2.4°±2.2° and 3.8°±2.9°, respectively. Strong correlation was found between the true and measured bifurcation angles. Furthermore, no significant differences were found between the bifurcation angles measured using either technique. In clinical settings, large difference of 12.0°±10.6° was found between the two techniques.

    CONCLUSION: In the phantom setting, both techniques demonstrated a significant correlation to the true bifurcation angle. Despite the lack of agreement of the two techniques in the clinical context, our findings in phantoms suggest that MPR should be preferred to VRT for the measurement of coronary bifurcation angle by CCTA.

    Matched MeSH terms: Observer Variation
  12. Nimbalkar S, Oh YY, Mok RY, Tioh JY, Yew KJ, Patil PG
    J Prosthet Dent, 2018 Aug;120(2):252-256.
    PMID: 29551374 DOI: 10.1016/j.prosdent.2017.10.021
    STATEMENT OF PROBLEM: Buccal corridor space and its variations greatly influence smile attractiveness. Facial types are different for different ethnic populations, and so is smile attractiveness. The subjective perception of smile attractiveness of different populations may vary in regard to different buccal corridor spaces and facial patterns.

    PURPOSE: The purpose of this study was to determine esthetic perceptions of the Malaysian population regarding the width of buccal corridor spaces and their effect on smile esthetics in individuals with short, normal, and long faces.

    MATERIAL AND METHODS: The image of a smiling individual with a mesofacial face was modified to create 2 different facial types (brachyfacial and dolicofacial). Each face form was further modified into 5 different buccal corridors (2%, 10%, 15%, 22%, and 28%). The images were submitted to 3 different ethnic groups of evaluators (Chinese, Malay, Indian; 100 each), ranging between 17 and 21 years of age. A visual analog scale (50 mm in length) was used for assessment. The scores given to each image were compared with the Kruskal-Wallis test, and pairwise comparison was performed using the Mann-Whitney U test (α=.05).

    RESULTS: All 3 groups of evaluators could distinguish gradations of dark spaces in the buccal corridor at 2%, 10%, and 28%. Statistically significant differences were observed among 3 groups of evaluators in esthetic perception when pairwise comparisons were performed. A 15% buccal corridor was found to score esthetically equally within 3 face types by all 3 groups of evaluators. The Indian population was more critical in evaluation than the Chinese or Malay populations. In a pairwise comparison, more significant differences were found between long and short faces and the normal face; the normal face was compared with long and short faces separately.

    CONCLUSIONS: The width of the buccal corridor space influences smile attractiveness in different facial types. A medium buccal corridor (15%) is the esthetic characteristic preferred by all groups of evaluators in short, normal, and long face types.

    Matched MeSH terms: Observer Variation
  13. Geeta A, Jamaiyah H, Safiza MN, Khor GL, Kee CC, Ahmad AZ, et al.
    Singapore Med J, 2009 Oct;50(10):1013-8.
    PMID: 19907894
    INTRODUCTION: The Third National Health and Morbidity Survey Malaysia 2006 includes a nutritional status assessment of children. This study aimed to assess the inter- and intra-examiner reliability, the technical error of measurement and the validity of instruments for measuring weight, height and waist circumference.
    METHODS: A convenience sample of 130 adults working in a selected office setting was chosen to participate in the study, subject to the inclusion and exclusion study criteria. Two public health nurses, trained to follow a standard protocol, obtained the weight, height and waist circumference measurements. The weight was measured using the Tanita HD-318 digital weighing scale to the nearest 0.1 kg, and Seca Beam Scale to the nearest 0.01 kg. The height was measured using the Seca Bodymeter 206 and Stadiometer, both to the nearest 0.1 cm. The waist circumference was measured using the Seca circumference measuring tape S 201, to the nearest 0.1 cm.
    RESULTS: The intra-examiner reliability in descending order was weight and height followed by waist circumference. The height measurement, on average, using the test instrument, reported a recording of 0.4 cm higher than the reference instrument, with the upper and lower limits at 2.5 cm and 1.6 cm, respectively. The technical error of measurement and coefficient of variation of weight and height for both inter-examiner and intra-examiner measurements were all within acceptable limits (below five percent).
    CONCLUSION: The findings of this study suggest that weight, height and waist circumference measured in adults aged 18 years and above, using the respective above mentioned instruments, are reliable and valid for use in a community survey. Limiting the number of examiners, especially for waist circumference measurements, would yield a higher degree of reliability and validity.
    Matched MeSH terms: Observer Variation
  14. Jamaluddin S, Sulaiman AR, Imran MK, Juhara H, Ezane MA, Nordin S
    Singapore Med J, 2011 Sep;52(9):681-4.
    PMID: 21947147
    The aim of this study was to determine the reliability and accuracy of the tape measurement method (TMM) with a nearest reading of 5 mm in assessing leg length discrepancy (LLD).
    Matched MeSH terms: Observer Variation
  15. Yap KL, Lam SK
    J Virol Methods, 1994 Apr;47(1-2):217-26.
    PMID: 8051228
    A simple, rapid and objective infectivity assay based on an in situ enzyme immunoassay (EIA) was developed for the fast-growing and cytopathic cell culture-adapted hepatitis A virus (HAV) strain HM175A.2. Infectivity titration by EIA correlated well with titration by cytopathic effects. The reliability of this assay was demonstrated by close agreement in virus infectivity titers among different assays of the same virus aliquot and between assays of different virus aliquots. HAV infected cell cultures after fixation could be stored for up to 1 week before testing without decline in virus titer.
    Matched MeSH terms: Observer Variation
  16. Peyman M, Tai LY, Khaw KW, Ng CM, Win MM, Subrayan V
    Int Ophthalmol, 2015 Oct;35(5):651-5.
    PMID: 25189684 DOI: 10.1007/s10792-014-9989-6
    To assess the intra-observer repeatability and inter-observer reproducibility of central corneal thickness (CCT) measurements of PachPen (Accutome, Inc., Pennsylvania, USA), a hand-held, portable ultrasonic pachymeter when used by an ophthalmic nurse compared to an ophthalmologist. Ophthalmology Clinic, University of Malaya Medical Center In this prospective study, CCT was measured in 184 eyes of 92 healthy subjects, first by a corneal surgeon experienced in ultrasound pachymetry (Observer 1) followed by an ophthalmic nurse new to the procedure (Observer 2). Nine measurements were obtained from each eye by each observer, independently. Measurements were compared between the observers. Coefficients of repeatability and reproducibility were calculated. The Bland-Altman plot was used to assess agreement between observers. Mean age of the study population was 54.3 ± 15.2 years old and consisted of 43.5% male. Mean CCT as measured by Observers 1 and 2 were 528.3 ± 32.9 and 530.7 ± 33.3 µm, respectively. Observer 1 showed higher repeatability of measurements compared to that of Observer 2 (coefficient of repeatability 3.46 vs. 5.55%). The measurements by both observers showed high correlation (0.96) and good agreement (mean difference -2.4 µm; 95% limits of agreement -21.4, 16.7 µm). Coefficient of reproducibility of measurements between observers was 5.08%. Accutome PachPen hand-held ultrasound pachymeters gives excellent intra-observer repeatability and inter-observer reproducibility by personnel of different training grades.
    Matched MeSH terms: Observer Variation
  17. Gan HS, Tan TS, Wong LX, Tham WK, Sayuti KA, Abdul Karim AH, et al.
    Biomed Mater Eng, 2014;24(6):3145-57.
    PMID: 25227024 DOI: 10.3233/BME-141137
    In medical image segmentation, manual segmentation is considered both labor- and time-intensive while automated segmentation often fails to segment anatomically intricate structure accordingly. Interactive segmentation can tackle shortcomings reported by previous segmentation approaches through user intervention. To better reflect user intention, development of suitable editing functions is critical. In this paper, we propose an interactive knee cartilage extraction software that covers three important features: intuitiveness, speed, and convenience. The segmentation is performed using multi-label random walks algorithm. Our segmentation software is simple to use, intuitive to normal and osteoarthritic image segmentation and efficient using only two third of manual segmentation's time. Future works will extend this software to three dimensional segmentation and quantitative analysis.
    Matched MeSH terms: Observer Variation
  18. Mansourvar M, Ismail MA, Herawan T, Raj RG, Kareem SA, Nasaruddin FH
    Comput Math Methods Med, 2013;2013:391626.
    PMID: 24454534 DOI: 10.1155/2013/391626
    Bone age assessment (BAA) of unknown people is one of the most important topics in clinical procedure for evaluation of biological maturity of children. BAA is performed usually by comparing an X-ray of left hand wrist with an atlas of known sample bones. Recently, BAA has gained remarkable ground from academia and medicine. Manual methods of BAA are time-consuming and prone to observer variability. This is a motivation for developing automated methods of BAA. However, there is considerable research on the automated assessment, much of which are still in the experimental stage. This survey provides taxonomy of automated BAA approaches and discusses the challenges. Finally, we present suggestions for future research.
    Matched MeSH terms: Observer Variation
  19. Gomez R, Vance A
    J Abnorm Child Psychol, 2008 Aug;36(6):955-67.
    PMID: 18317918 DOI: 10.1007/s10802-008-9226-8
    This study examined differential symptom functioning (DSF) in ADHD symptoms across Malay and Chinese children in Malaysia. Malay (N=571) and Chinese (N=254) parents completed the Disruptive Behavior Rating Scale, which lists the DSM-IV ADHD symptoms. DSF was examined using the multiple indicators multiple causes (MIMIC) structural equation modeling procedure. Although DSF was found for a single inattention (IA) symptom and three hyperactivity-impulsivity (HI) symptoms, all these differences had low effect sizes. Controlling for these DSF, Chinese children had higher IA and HI latent factor scores. However the effect sizes were small. Together, these findings suggest adequate support for invariance of the ADHD symptoms across these ethno-cultural groups. The implications of the findings for cross-cultural invariance of the ADHD symptoms are discussed.
    Matched MeSH terms: Observer Variation
  20. Nair SR, Tan LK, Mohd Ramli N, Lim SY, Rahmat K, Mohd Nor H
    Eur Radiol, 2013 Jun;23(6):1459-66.
    PMID: 23300042 DOI: 10.1007/s00330-012-2759-9
    OBJECTIVE: To develop a decision tree based on standard magnetic resonance imaging (MRI) and diffusion tensor imaging to differentiate multiple system atrophy (MSA) from Parkinson's disease (PD).

    METHODS: 3-T brain MRI and DTI (diffusion tensor imaging) were performed on 26 PD and 13 MSA patients. Regions of interest (ROIs) were the putamen, substantia nigra, pons, middle cerebellar peduncles (MCP) and cerebellum. Linear, volumetry and DTI (fractional anisotropy and mean diffusivity) were measured. A three-node decision tree was formulated, with design goals being 100 % specificity at node 1, 100 % sensitivity at node 2 and highest combined sensitivity and specificity at node 3.

    RESULTS: Nine parameters (mean width, fractional anisotropy (FA) and mean diffusivity (MD) of MCP; anteroposterior diameter of pons; cerebellar FA and volume; pons and mean putamen volume; mean FA substantia nigra compacta-rostral) showed statistically significant (P < 0.05) differences between MSA and PD with mean MCP width, anteroposterior diameter of pons and mean FA MCP chosen for the decision tree. Threshold values were 14.6 mm, 21.8 mm and 0.55, respectively. Overall performance of the decision tree was 92 % sensitivity, 96 % specificity, 92 % PPV and 96 % NPV. Twelve out of 13 MSA patients were accurately classified.

    CONCLUSION: Formation of the decision tree using these parameters was both descriptive and predictive in differentiating between MSA and PD.

    KEY POINTS: • Parkinson's disease and multiple system atrophy can be distinguished on MR imaging. • Combined conventional MRI and diffusion tensor imaging improves the accuracy of diagnosis. • A decision tree is descriptive and predictive in differentiating between clinical entities. • A decision tree can reliably differentiate Parkinson's disease from multiple system atrophy.

    Matched MeSH terms: Observer Variation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links