MATERIALS AND METHODS: English speaking patients older than 18 years of age with a defi nite diagnosis of MS were included. The self-administered survey material included the adapted HRQoL questionnaire, a validated generic HRQoL questionnaire: the short-form 36 (SF-36), as well as a checklist of 14 symptoms. We assessed the internal and external validity of the adapted MusiQoL.
RESULTS: A total of 81 patients with MS were included in the study. The questionnaire was generally well accepted. In the samples from Malaysia and Singapore, all scales exhibited good internal consistency (Cronbach's alpha >0.70). Correlation to SF-36 was generally good, demonstrating high construct validity (P <0.001) in some aspects of the MusiQoL.
CONCLUSION: The Asian adaptation of the English version of the MusiQoL in evaluating HRQoL seems to be a valid, reliable tool with adequate patient acceptability and internal consistency.
METHODS: A total of 497 patients with type 2 diabetes mellitus were recruited from public hospitals in the state of Selangor through convenience sampling. Construct validity was evaluated through confirmatory factor analysis. Internal consistency of the instrument was tested by Cronbach α. Criterion validity and discriminant validity were also used.
RESULTS: The PAID instrument consisted of 3 factors: social support problem, food-related problem, and emotional distress problem. The Cronbach α values of the 3 factors showed adequate internal consistency with α values greater than 0.90. The present confirmatory factor analysis model achieved a good fit with a comparative fit index value of 0.923. Satisfactory criterion validity was also demonstrated because there existed positive significant association between glycated hemoglobin A1c and diabetes duration.
CONCLUSIONS: The PAID questionnaire in Malaysia was found to be a reliable and valid instrument exhibiting good psychometric properties.
OBJECTIVE: The primary objective of this study was to examine the validity and reliability of the Borg CR-10 scale to monitor the perceived exertion of office exercise training.
METHODS: The study involved 105 staff members employed in a government office with an age range from 25 to 50 years. The Borg CR-10 scale was self-administered two times, with an interval of two weeks in order to evaluate the accuracy of the original findings with a retest. Face validity and content validity were also examined.
RESULTS: Reliability was found to be high for the Borg CR-10 scale (0.898). Additionally a high correlation between the Borg CR-10 scale and Visual Analog Scale (VAS) was identified (rs = 0.754, P
METHODS: The Malay version was translated by two independent translators who were well versed in both languages. We carried out a cross-sectional study collecting data between June 2017 and March 2018 in the pre-operative Eye Clinic of Hospital Melaka with 224 respondents (mean age 66.8 years) and another 204 respondents (mean age 64.3 years) participating in the English version and Malay version of the Questionnaire respectively. Methods used to validate the standard questionnaire included the use of construct validity via factor analysis and the deployment of reliability test through assessment of internal consistency via Cronbach's alpha.
RESULTS: We observed both English and Bahasa Malaysia versions to have high reliability with Cronbach's alpha values of 0.90 and above in factors on difficulty with activities and responses to vision problems. Exploratory factor analysis performed revealed that the three-factor model fits the data well for the English version of the questionnaire - difficulty with activities (23.81 % of variance), responses to vision problem (22.22 % of variance) and general health and vision (14.68 % of variance). The Bahasa Malaysia version of the questionnaire produced three factors with two of the factors resembling the factors from the original version of the questionnaire - difficulty with activities (24.3 % of variance) and responses to vision problem (23.7 % of variance). Item response theory analysis revealed that these factors for both English and Bahasa Malaysia versions comprised of adequately fitted items.
CONCLUSION: The present study observed that both the English and Bahasa Malaysia versions of the NEI VFQ-25 have comparable construct validity to the original American version. With high validity and reliability, the tool shall be able to provide health care providers the assessment of impact due to cataract and other ophthalmic conditions on the vision-related quality of life of ophthalmic patients.