MEATERIALS AND METHODS: A cross-sectional diagnostic study was performed on patients with edematous mucosa of the middle turbinate head. Under traditional white light endoscopy, areas of edematous mucosa were identified. Using NBI, these areas were compared to areas of normal mucosa on the middle turbinate head. NBI images of these same areas were then converted to grey scale and a vascularity index was created by pixel analysis and brightness in Fiji Image J software (Wisconsin, US).
RESULTS: Thirty-three middle turbinates were assessed (age 42.4 ± 12.5, 42.4% female). NBI discriminated between areas identified under white light endoscopy as edematous and normal (158.2 ± 48.4 v 96.9 ± 32.7 p
METHODOLOGY: Tracheal aspirates were obtained from neonates on ventilatory support. The SM test was carried out on specimens of tracheal aspirate immediately after collection. Levels of SP-A in tracheal aspirates were determined by enzyme-linked immunosorbent assay (ELISA) method. The results of the SM test and SP-A level of the tracheal aspirates were compared against the clinical diagnosis of RDS based on clinical, radiological and bacteriological findings.
RESULTS: Both the median microbubble counts (6 microbubbles/mm2, range = 0-90) and median SP-A levels (100 micrograms/L, range = 0-67447) of infants with RDS were significantly lower than those of infants with no obvious lung pathology (P < 0.0001), and pneumonia (P < 0.0001). The SM test of tracheal aspirates had higher overall accuracy for the diagnosis of RDS than measurement of SP-A levels (94.6% vs 82.4%). When the receiver operating characteristic (ROC) curves of both tests for RDS were compared, the area under the ROC curve of the SM test was larger (0.9689) than that of the SP-A method (0.8965).
CONCLUSIONS: This study showed that the SM test of tracheal aspirate was a useful bedside diagnostic test for RDS. It could be carried out at any time after birth on infants requiring ventilatory support.
GOALS: The goal was to ascertain whether urine testing could be used as screening method to detect C. trachomatis infections in commercial sex workers, patients at sexually transmitted diseases clinic, and asymptomatic patients in Kuala Lumpur, Malaysia.
METHODS: First-void urine specimens from 300 men and 300 women were tested by LCR, as well as by a commercially available enzyme immunoassay. The LCR assay amplifies specific sequences within the chlamydial plasmid with ligand-labeled probes, and the resultant amplicons are detected by an automated immunoassay. Specimens with discrepant results were confirmed by another LCR of the specimen that targeted the gene for the major outer membrane protein (OMP1).
RESULTS: There were 31 LCR-positive male urine and 37 LCR-positive female urine specimens. The resolved sensitivity and specificity for the LCR of the male urine specimens were 100% and 99.6%, respectively, whereas for female urine specimens, the sensitivity and specificity were 100% and 98.5%, respectively. After resolution of discrepant test results by OMP1 LCR, the prevalence was 10% for men and 11% for women. The urine enzyme immunoassay was not useful in diagnosing C. trachomatis infections in either men or women, as the resolved sensitivities were 10% and 15.2%, respectively. The specificities were 99.6% for men and 98.9% for women.
CONCLUSIONS: Testing first-void urine specimens by LCR is a highly sensitive and specific method to diagnose C. trachomatis infections in men and women, providing health care workers and public health officials with a new molecular amplification assay that uses noninvasive urine specimens for population-based screening purposes.
METHODS: Twelve relevant manuscripts were sourced from a total of 7288 search results obtained using PubMed, Medline and Google Scholar. The search keywords used were COVID-19, nasopharyngeal, oropharyngeal, swabs, SARS and CoV2. Original manuscripts were obtained and analysed by all authors. The review included manuscripts which have not undergone rigorous peer-review process in view of the magnitude of the topic discussed.
RESULTS: The viral load of SARS-CoV-2 RNA in the upper respiratory tract was significantly higher during the first week and peaked at 4-6 days after onset of symptoms, during which it can be potentially sampled. Nasopharyngeal swab has demonstrated higher viral load than oropharyngeal swab, where the difference in paired samples is best seen at 0-9 days after the onset of illness. Sensitivity of nasopharyngeal swab was higher than oropharyngeal swabs in COVID-19 patients. Patient self-collected throat washing has been shown to contain higher viral load than nasopharyngeal or oropharyngeal swab, with significantly higher sensitivity when compared with paired nasopharyngeal swab.
RECOMMENDATIONS: Routine nasopharyngeal swab of suspected COVID-19 infection should take anatomy of the nasal cavity into consideration to increase patient comfort and diagnostic yield. Routine oropharyngeal swab should be replaced by throat washing which has demonstrated better diagnostic accuracy, and it is safe towards others.
OBJECTIVES: To determine the diagnostic accuracy (sensitivity and specificity) of ultrasound estimated fetal weight discordance (EFWD) of 20% and 25% using different estimated biometric ultrasound measurements compared with the actual BWD as the reference standard in twin pregnancies.
SEARCH METHODS: The search for this review was performed on 15 March 2019. We searched CENTRAL, MEDLINE (Ovid), Embase (Ovid), seven other databases, conference proceedings, reference lists and contacted experts. There were no language or date restrictions applied to the electronic searches, and no methodological filters to maximize sensitivity.
SELECTION CRITERIA: We selected cohort-type studies with delayed verification that evaluated the accuracy of biometric measurements at ultrasound scanning of twin pregnancies that had been proposed for the diagnosis of estimated BWD, compared to BWD measurements after birth as a reference standard. In addition, we only selected studies that considered twin pregnancies and applied a reference standard for EFWD for the target condition of BWD.
DATA COLLECTION AND ANALYSIS: We screened all titles generated by electronic database searches. Two review authors independently assessed the abstracts of all potentially relevant studies. We assessed the identified full papers for eligibility, and extracted data to create 2 × 2 tables. Two review authors independently performed quality assessment using the QUADAS-2 tool. We excluded studies that did not report data in sufficient detail to construct 2 × 2 tables, and where this information was not available from the primary investigators. We assessed the certainty of the evidence using the GRADE approach.
MAIN RESULTS: We included 39 eligible studies with a median study sample size of 140. In terms of risk of bias, there were many unclear statements regarding patient selection, index test and use of proper reference standard. Twenty-one studies (53%) were of methodological concern due to flow and timing. In terms of applicability, most studies were of low concern. Ultrasound for diagnosis of BWD in twin pregnancies at 20% cut-off Twenty-two studies provided data for a BWD of 20% and the summary estimate of sensitivity was 0.51 (95% CI 0.42 to 0.60), and the summary estimate of specificity was 0.91 (95% CI 0.89 to 0.93) (8005 twin pregnancies; very low-certainty evidence). Ultrasound for diagnosis of BWD in twin pregnancies at 25% cut-off Eighteen studies provided data using a BWD discordance of 25%. The summary estimate of sensitivity was 0.46 (95% CI 0.26 to 0.66), and the summary estimate of specificity was 0.93 (95% CI 0.89 to 0.96) (6471 twin pregnancies; very low-certainty evidence). Subgroup analyses were possible for both BWD of 20% and 25%. The diagnostic accuracy did not differ substantially between estimation by abdominal circumference and femur length but femur length had a trend towards higher sensitivity and specificity. Subgroup analyses were not possible by sex of twins, chorionicity or gestational age due to insufficient data.
AUTHORS' CONCLUSIONS: Very low-certainty evidence suggests that EFWD identified by ultrasound has low sensitivity but good specificity in detecting BWD in twin pregnancies. There is uncertain diagnostic value of EFWD; this review suggests there is insufficient evidence to support this index as the sole measure for clinical decision making to evaluate the prognosis of twins with growth discordance. The diagnostic accuracy of other measures including amniotic fluid index and umbilical artery Doppler resistive indices in combination with ultrasound for clinical intervention requires evaluation. Future well-designed studies could also evaluate the impact of chorionicity, sex and gestational age in the diagnostic accuracy of ultrasound for EFWD.