Displaying publications 41 - 60 of 1043 in total

Abstract:
Sort:
  1. Wong E, Hamizan AW, Alvarado R, Orgain CA, Kalish L, Sacks R, et al.
    Am J Otolaryngol, 2018 06 22;39(5):570-574.
    PMID: 29961655 DOI: 10.1016/j.amjoto.2018.06.019
    PURPOSE: Middle turbinate head edema has recently been found to have high specificity for diagnosis of inhalant allergy. However, subtle mucosal edema can be difficult to appreciate under white light endoscopy. Narrow band imaging (NBI) has the potential to demonstrate edema by identifying reduced mucosal vascularity and improve sensitivity for the detection of mucosal edema. Narrow band imaging was assessed to determine its utility in objectifying mucosal edema.

    MEATERIALS AND METHODS: A cross-sectional diagnostic study was performed on patients with edematous mucosa of the middle turbinate head. Under traditional white light endoscopy, areas of edematous mucosa were identified. Using NBI, these areas were compared to areas of normal mucosa on the middle turbinate head. NBI images of these same areas were then converted to grey scale and a vascularity index was created by pixel analysis and brightness in Fiji Image J software (Wisconsin, US).

    RESULTS: Thirty-three middle turbinates were assessed (age 42.4 ± 12.5, 42.4% female). NBI discriminated between areas identified under white light endoscopy as edematous and normal (158.2 ± 48.4 v 96.9 ± 32.7 p 

    Matched MeSH terms: Sensitivity and Specificity
  2. Tan GC, Sharifah NA, Shiran MS, Salwati S, Hatta AZ, Paul-Ng HO
    Asian Pac J Cancer Prev, 2008 Oct-Dec;9(4):781-4.
    PMID: 19256776
    The differentiation between cervical intraepithelial neoplasia 3 (CIN 3) and early squamous cell carcinoma (SCC) of the cervix may be difficult in certain situations. Identification of invasion beyond the basement membrane is the gold standard for the diagnosis of the latter. The objective of this study was to determine whether the use of Ki-67 and p53 could help in solving the above dilemma. This was a retrospective study on 61 cases of cervical neoplasms comprising of 25 cases of CIN 3 and 36 SCC. All cases were evaluated by immunohistochemistry using Ki-67 and p53 monoclonal antibodies. Results showed that the differences of Ki-67 and p53 expression between CIN 3 and SCC were statistically significant. In conclusion, Ki-67 and p53 may serve as helpful adjuncts to routinely-stained histological sections in differentiating between CIN 3 and SCC.
    Matched MeSH terms: Sensitivity and Specificity
  3. Choo KE, Razif AR, Oppenheimer SJ, Ariffin WA, Lau J, Abraham T
    J Paediatr Child Health, 1993 Feb;29(1):36-9.
    PMID: 8461177
    Data are presented for 2382 children investigated for fever in a Malaysian hospital between 1984 and 1987 when Widal tests and blood cultures were a routine part of every fever screen. There were 145 children who were culture positive (TYP-CP) for Salmonella typhi, while 166 were culture negative but were diagnosed as having typhoid (TYP-CN). Analyses of the sensitivity and specificity of combinations of initial Widal titres in predicting a positive S. typhi culture in a febrile child (culture positive vs the rest) showed the best model to be an O- and/or H-titre of > or = 1 in 40 (sensitivity 89%; specificity 89%). While the negative predictive value of the model was high (99.2%) the positive predictive value remained below 50% even for very high titres of O and H (> 1 in 640), at which point the specificity was 98.5%, supporting the clinical view that a high proportion of the TYP-CN patients really were typhoid but were missed by culture. The TYP-CN patients showed a very similar clinical and age profile to TYP-CP patients. The length of history of fever did not affect the initial Widal titre in culture positive cases. The Widal test in children remains a sensitive and specific 'fever screen' for typhoid although it will not identify all cases. In children, lower cut-off points for O- and H-titres should be used than are generally recommended.
    Matched MeSH terms: Sensitivity and Specificity
  4. Indran SK
    Singapore Med J, 1995 Apr;36(2):194-6.
    PMID: 7676267
    This study examines the usefulness of the "CAGE", (which is an acronym for "cut down", "annoyed", "guilty" and "eye-opener"), a 4-question screening test to identify excessive drinkers among Malaysian inpatients. The CAGE questionnaire after translation and back translation was administered to all inpatients in the General Hospital, Kuala Lumpur. The author interviewed 'blindly' all who score positive on the CAGE score and 10% of all negatives using the DSM III interview schedule for alcohol abuse dependence. The results show that the CAGE performs best at a cut-off point of 2 and above, with a sensitivity of 92%, specificity of 62%, positive predictive values of 38% and Kappa (K) of 0.37 with a DSM III R diagnosis for alcohol abuse/dependence. The poor agreement with a DSM III diagnosis indicates that the CAGE is not useful in the Malaysian population. Reasons suggested for this are: cultural factors in the Malaysian population resulting in the overrating of the question of 'guilt' by Muslims and translations into the local languages which are only the closest approximations.
    Matched MeSH terms: Sensitivity and Specificity
  5. Boo NY, Cheong KB, Cheong SK, Lye MS, Zulfiqar MA
    J Paediatr Child Health, 1997 Aug;33(4):329-34.
    PMID: 9323622
    OBJECTIVES: To compare the overall accuracy of the stable microbubble test (SM test) with measurement of level of surfactant protein A (SP-A) of tracheal aspirate for the diagnosis of respiratory distress syndrome (RDS).

    METHODOLOGY: Tracheal aspirates were obtained from neonates on ventilatory support. The SM test was carried out on specimens of tracheal aspirate immediately after collection. Levels of SP-A in tracheal aspirates were determined by enzyme-linked immunosorbent assay (ELISA) method. The results of the SM test and SP-A level of the tracheal aspirates were compared against the clinical diagnosis of RDS based on clinical, radiological and bacteriological findings.

    RESULTS: Both the median microbubble counts (6 microbubbles/mm2, range = 0-90) and median SP-A levels (100 micrograms/L, range = 0-67447) of infants with RDS were significantly lower than those of infants with no obvious lung pathology (P < 0.0001), and pneumonia (P < 0.0001). The SM test of tracheal aspirates had higher overall accuracy for the diagnosis of RDS than measurement of SP-A levels (94.6% vs 82.4%). When the receiver operating characteristic (ROC) curves of both tests for RDS were compared, the area under the ROC curve of the SM test was larger (0.9689) than that of the SP-A method (0.8965).

    CONCLUSIONS: This study showed that the SM test of tracheal aspirate was a useful bedside diagnostic test for RDS. It could be carried out at any time after birth on infants requiring ventilatory support.

    Matched MeSH terms: Sensitivity and Specificity
  6. George J
    Singapore Med J, 1996 Apr;37(2):181-3.
    PMID: 8942259
    This study evaluates the usefulness of measuring gastric antral thickness on conventional ultrasonography as a means of suggesting gastric antral pathology. Normal and abnormal appearances of the gastric antrum are reviewed.
    Matched MeSH terms: Sensitivity and Specificity
  7. Boo NY, Nor Azlina AA, Rohana J
    Singapore Med J, 2008 Mar;49(3):204-8.
    PMID: 18363001
    This study was designed to determine the sensitivity and specificity of a semi-quantitative procalcitonin (PCT) test kit for the diagnosis of neonatal sepsis.
    Matched MeSH terms: Sensitivity and Specificity
  8. Lee WS, Looi LM
    World J Gastroenterol, 2009 Nov 14;15(42):5326-33.
    PMID: 19908342 DOI: 10.3748/wjg.15.5326
    AIM: To ascertain the usefulness of a histological scoring system devised to assist in the interpretation of liver histology in neonatal cholestasis (NC).

    METHODS: Liver biopsy specimens obtained from infants with NC referred to a tertiary pediatric unit in Malaysia were prospectively studied. The first author, blinded to the final diagnosis, devised the histological diagnosis based on a 7-feature (portal ductal proliferation, bile plugs in portal ductules, porto-portal bridging, lymphocytic infiltration in portal region, multinucleated hepatocytes, neutrophilic infiltration, hepatocellular swelling), 15-point (0 to 15) scoring system. The author classified the histological diagnosis as either biliary atresia (BA) or neonatal hepatitis (NH, all other diagnoses), and subsequently compared the author's diagnosis with the final diagnosis.

    RESULTS: Eighty-four biopsy specimens obtained from 78 patients were reviewed. Without the scoring system, BA was correctly diagnosed by the author histologically in 30 cases, labelled as NH in 3. For other diagnoses, BA was excluded correctly in 33 cases and mislabeled as BA in 2 cases. The overall sensitivity for BA was 91%, specificity 86% and accuracy 88%. With the scoring system, a score of >or=7 had the best diagnostic utility to differentiate BA from other intrahepatic cholestasis histologically (sensitivity 88%, specificity 94%, accuracy 92%). Four patients with a score<7 had BA, and 3 patients with a score>or=7 had NH.

    CONCLUSION: A 7-feature, 15-point histological scoring system had good diagnostic accuracy in the interpretation of liver histology in neonatal cholestasis.
    Matched MeSH terms: Sensitivity and Specificity
  9. Lo MS, Ng ML, Wu LL, Azmy BS, Khalid BA
    Malays J Pathol, 1996 Jun;18(1):43-52.
    PMID: 10879224
    Since conventional radioimmunoassays (RIA) for measurement of 17-hydroxyprogesterone (17-OHP) in serum samples require a laborious solvent extraction step, a direct and rapid in-house RIA was developed for early diagnosis and management of congenital adrenal hyperplasia (CAH). In-house rabbit anti-17-OHP antiserum, tritium labelled 17-OHP and dextran-coated charcoal were used in assay buffer with low pH 5.1 and preheated serum samples. Both inter- and intra-assay CVs were < 10% and the sensitivity was 1.2 nmol/l or 12 fmol/tube. Results from the direct assay correlated well with values from an extraction assay, r = 0.88 in samples from CAH patients, r = 0.85 in adults and children, 0.69 and 0.40 in term and preterm neonates respectively, 0.66 and 0.63 in luteal phase and third trimester pregnancy; p < 0.001 in all groups except p < 0.05 in preterm neonates. However, results from the direct assay were two to three times higher in serum samples from CAH patients, normal adults and children, but were five to seven times higher in pregnancy and term neonates and thirty times higher in preterm neonates. The markedly elevated levels measured by the direct assay are probably due to cross-reactivities with water-soluble steroid metabolites such as 17-hydroxypregnenolone sulphate and dehydroepiandrosterone sulphate (DHEAS). Although the direct assay is only useful as a screening test for preterm babies, it can be used for both diagnosis and monitoring of treatment of CAH in all other age groups.
    Matched MeSH terms: Sensitivity and Specificity
  10. Ding YY, Lieu PK, Choo PWJ
    Med J Malaysia, 1998 Sep;53(3):209-16.
    PMID: 10968155
    The uroflow and pressure-flow data of 67 men aged 65 years or more were compared. At best, the uroflow study applying the Liverpool nomogram (25th percentile) and Bristol nomogram (OSD) diagnosed bladder outlet obstruction with sensitivity of 62.5% and 62.5% and specificity of 48.8% and 74.4% respectively. Using the 50th percentile of the Liverpool nomogram as the cut-off resulted in a negative predictive value of 100.0% allowing about 10% of men to have this diagnosis ruled out. We conclude that the uroflow study is inaccurate in diagnosing bladder outlet obstruction in elderly men. However, it can be used to rule out this condition in the small subset of men with maximum flow rates above the 50th percentile of the Liverpool nomogram.
    Matched MeSH terms: Sensitivity and Specificity
  11. Azian M, Hapizah MN, Khalid BA, Khalid Y, Rosli A, Jamal R
    Malays J Pathol, 2006 Jun;28(1):7-15.
    PMID: 17694954 MyJurnal
    Familial hypercholesterolaemia (FH) and Familial defective apolipoprotein B100 (FDB) are autosomal dominant inherited diseases of lipid metabolism caused by mutations in the low density lipoprotein (LDL) receptor and apolipoprotein B 100 genes. FH is clinically characterised by elevated concentrations of total cholesterol (TC) and low density lipoprotein cholesterol (LDL-C), presence of xanthomata and premature atherosclerosis. Both conditions are associated with coronary artery disease but may be clinically indistinguishable. Seventy-two (72) FH patients were diagnosed based on the Simon Broome's criteria. Mutational screening was performed by polymerase chain reaction (PCR)-denaturing gradient gel electrophoresis (DGGE). Positive mutations were subjected to DNA sequencing for confirmation of the mutation. We successfully amplified all exons in the LDL receptor and apo B100 genes. DGGE was performed in all exons of the LDL receptor (except for exons 4-3', 18 and promoter region) and apo B100 genes. We have identified four different mutations in the LDL receptor gene but no mutation was detected in the apo B 100 gene. The apo B100 gene mutation was not detected on DGGE screening as sequencing was not performed for negative cases on DGGE technique. To our knowledge, the C234S mutation (exon 5) is a novel mutation worldwide. The D69N mutation (exon 3) has been reported locally while the R385W (exon 9) and R716G (exon 15) mutations have not been reported locally. However, only 4 mutations have been identified among 14/72 patients (19.4%) in 39 FH families. Specificity (1-false positive) of this technique was 44.7% based on the fact that 42/76 (55.3%) samples with band shifts showed normal DNA sequencing results. A more sensitive method needs to be addressed in future studies in order to fully characterise the LDLR and apo B100 genes such as denaturing high performance liquid chromatography. In conclusion, we have developed the DNA analysis for FH patients using PCR-DGGE technique. DNA analysis plays an important role to characterise the type of mutations and forms an adjunct to clinical diagnosis.
    Matched MeSH terms: Sensitivity and Specificity
  12. Ooi DJ, Dzulkurnain A, Othman RY, Lim SH, Harikrishna JA
    J Virol Methods, 2006 Sep;136(1-2):160-5.
    PMID: 16781785
    A modified method for the rapid isolation of specific ligands to whole virus particles is described. Biopanning against cymbidium mosaic virus was carried out with a commercial 12-mer random peptide display library. A solution phase panning method was devised using streptavidin-coated superparamagnetic beads. The solution based panning method was more efficient than conventional immobilized target panning when using whole viral particles of cymbidium mosaic virus as a target. Enzyme-linked immunosorbent assay of cymbidium mosaic virus-binding peptides isolated from the library identified seven peptides with affinity for cymbidium mosaic virus and one peptide which was specific to cymbidium mosaic virus and had no significant binding to odontoglossum ringspot virus. This method should have broad application for the screening of whole viral particles towards the rapid development of diagnostic reagents without the requirement for cloning and expression of single antigens.
    Matched MeSH terms: Sensitivity and Specificity
  13. Nadarajan V, Sthaneshwar P, Eow GI
    Transfus Med, 2008 Jun;18(3):184-9.
    PMID: 18598281 DOI: 10.1111/j.1365-3148.2008.00862.x
    The objective of this study was to identify haematological parameters useful in screening for iron deficiency among blood donors. Iron deficiency is a common complication of blood donation and often goes unrecognized until anaemia develops. Biochemical markers such as soluble transferrin receptor (TfR), ferritin and log(TfR/F) have been proposed as more valid indicators of body iron status. Red blood cell (RBC) parameters are, however, more easily measured and have also been proposed as indicators of iron depletion. We measured ferritin and TfR in 192 blood donors together with RBC analysis, performed on two haematology analysers. Thirteen donors had parameters suggestive of haemoglobinopathy and were excluded from further analysis. Overall, 10% (18/179) of the remaining donors had iron deficiency, as defined by log(TfR/F) exceeding the 95th percentile of the value in the population of first-time donors. Using receiver operating characteristic analysis, the sensitivity of ferritin was 100%, with a specificity of 90% at a cut-off of 15 mug L(-1). The sensitivity and specificity of RBC-Y at a cut-off of 152 for detecting iron deficiency were 81 and 89%, respectively. Haemoglobin content of reticulocytes, meanwhile, showed sensitivity of 69% and specificity of 93% when a cut-off of 28 pg was used. Both measures compare favourably with haemoglobin which only showed a sensitivity of 50%, although specificity was 91% at a cut-off value of 125 g L(-1). The parameter RBC-Y can be useful as a screening measure for iron deficiency in blood donors.
    Matched MeSH terms: Sensitivity and Specificity
  14. Fang R, Sinniah M, Kuen LS
    Malays J Pathol, 1992 Dec;14(2):117-20.
    PMID: 1304624
    Dengue fever/Dengue haemorrhagic fever (DF/DHF) has been a public health problem in Malaysia with an endemic level of about 7 per 100,000 population per year. In 1990, Malaysia experienced its most severe outbreak of DF/DHF with a record total of 5,590 cases referred to the Division of Virology, Institute for Medical Research (IMR). Of these, 1,880 were confirmed serologically to be DF/DHF. The conventional serological procedure, the Haemagglutination Inhibition (HI) test, for the diagnosis of DF/DHF is cumbersome and causes delay in diagnosis. Another problem associated with the HI test has been that it has often been difficult to obtain a second convalescent serum sample for an accurate diagnosis. This has raised an urgent need to establish a "rapid" test for diagnosis of DF/DHF. As such the authors recently carried out an evaluation of a newly available commercial rapid test, namely, the Dengue Blot Assay (Diagnostic Biotechnology Singapore Pte Ltd). The test is intended for use in laboratory confirmation of dengue virus infection. The evaluation was to determine if the test could be utilised as a routine laboratory test and to establish its sensitivity and specificity. Over 400 samples were tested against the Dengue Blot Assay. Results were checked against an in-house Dengue IgM ELISA and HI assay. Preliminary results indicate that the sensitivity and specificity of the Dengue Blot is satisfactory. Our results also indicate that the Dengue Blot has a useful role to play in a routine laboratory especially since it provides rapid results on single serum samples thereby reducing the workload in a busy diagnostic laboratory.
    Matched MeSH terms: Sensitivity and Specificity*
  15. Gaydos CA, Ngeow YF, Lee HH, Canavaggio M, Welsh LE, Johanson J, et al.
    Sex Transm Dis, 1996 9 1;23(5):402-6.
    PMID: 8885072
    BACKGROUND AND OBJECTIVES: Noninvasive urine screening for Chlamydia trachomatis infections offers a valuable public health tool, which could be of vast importance in chlamydial control programs. The authors evaluated a new DNA amplification method, ligase chain reaction (LCR).

    GOALS: The goal was to ascertain whether urine testing could be used as screening method to detect C. trachomatis infections in commercial sex workers, patients at sexually transmitted diseases clinic, and asymptomatic patients in Kuala Lumpur, Malaysia.

    METHODS: First-void urine specimens from 300 men and 300 women were tested by LCR, as well as by a commercially available enzyme immunoassay. The LCR assay amplifies specific sequences within the chlamydial plasmid with ligand-labeled probes, and the resultant amplicons are detected by an automated immunoassay. Specimens with discrepant results were confirmed by another LCR of the specimen that targeted the gene for the major outer membrane protein (OMP1).

    RESULTS: There were 31 LCR-positive male urine and 37 LCR-positive female urine specimens. The resolved sensitivity and specificity for the LCR of the male urine specimens were 100% and 99.6%, respectively, whereas for female urine specimens, the sensitivity and specificity were 100% and 98.5%, respectively. After resolution of discrepant test results by OMP1 LCR, the prevalence was 10% for men and 11% for women. The urine enzyme immunoassay was not useful in diagnosing C. trachomatis infections in either men or women, as the resolved sensitivities were 10% and 15.2%, respectively. The specificities were 99.6% for men and 98.9% for women.

    CONCLUSIONS: Testing first-void urine specimens by LCR is a highly sensitive and specific method to diagnose C. trachomatis infections in men and women, providing health care workers and public health officials with a new molecular amplification assay that uses noninvasive urine specimens for population-based screening purposes.

    Matched MeSH terms: Sensitivity and Specificity
  16. Menon PS, Said FA, Mei GS, Berhanuddin DD, Umar AA, Shaari S, et al.
    PLoS One, 2018;13(7):e0201228.
    PMID: 30052647 DOI: 10.1371/journal.pone.0201228
    This work investigates the surface plasmon resonance (SPR) response of 50-nm thick nano-laminated gold film using Kretschmann-based biosensing for detection of urea and creatinine in solution of various concentrations (non-enzymatic samples). Comparison was made with the presence of urease and creatininase enzymes in the urea and creatinine solutions (enzymatic samples), respectively. Angular interrogation technique was applied using optical wavelengths of 670 nm and 785 nm. The biosensor detects the presence of urea and creatinine at concentrations ranging from 50-800 mM for urea samples and 10-200 mM for creatinine samples. The purpose of studying the enzymatic sample was mainly to enhance the sensitivity of the sensor towards urea and creatinine in the samples. Upon exposure to 670 nm optical wavelength, the sensitivity of 1.4°/M was detected in non-enzymatic urea samples and 4°/M in non-enzymatic creatinine samples. On the other hand, sensor sensitivity as high as 16.2°/M in urea-urease samples and 10°/M in creatinine-creatininase samples was detected. The enhanced sensitivity possibly attributed to the increase in refractive index of analyte sensing layer due to urea-urease and creatinine-creatininase coupling activity. This work has successfully proved the design and demonstrated a proof-of-concept experiment using a low-cost and easy fabrication of Kretschmann based nano-laminated gold film SPR biosensor for detection of urea and creatinine using urease and creatininase enzymes.
    Matched MeSH terms: Sensitivity and Specificity
  17. Mawaddah A, Gendeh HS, Lum SG, Marina MB
    Malays J Pathol, 2020 Apr;42(1):23-35.
    PMID: 32342928
    INTRODUCTION: To review the present literature on upper respiratory tract sampling in COVID-19 and provide recommendations to improve healthcare practices and directions in future studies.

    METHODS: Twelve relevant manuscripts were sourced from a total of 7288 search results obtained using PubMed, Medline and Google Scholar. The search keywords used were COVID-19, nasopharyngeal, oropharyngeal, swabs, SARS and CoV2. Original manuscripts were obtained and analysed by all authors. The review included manuscripts which have not undergone rigorous peer-review process in view of the magnitude of the topic discussed.

    RESULTS: The viral load of SARS-CoV-2 RNA in the upper respiratory tract was significantly higher during the first week and peaked at 4-6 days after onset of symptoms, during which it can be potentially sampled. Nasopharyngeal swab has demonstrated higher viral load than oropharyngeal swab, where the difference in paired samples is best seen at 0-9 days after the onset of illness. Sensitivity of nasopharyngeal swab was higher than oropharyngeal swabs in COVID-19 patients. Patient self-collected throat washing has been shown to contain higher viral load than nasopharyngeal or oropharyngeal swab, with significantly higher sensitivity when compared with paired nasopharyngeal swab.

    RECOMMENDATIONS: Routine nasopharyngeal swab of suspected COVID-19 infection should take anatomy of the nasal cavity into consideration to increase patient comfort and diagnostic yield. Routine oropharyngeal swab should be replaced by throat washing which has demonstrated better diagnostic accuracy, and it is safe towards others.

    Matched MeSH terms: Sensitivity and Specificity
  18. Hasni H, Meah FA, Norlia A, Sharifah NA, Zulfiqar A
    Med J Malaysia, 2004 Oct;59(4):486-94.
    PMID: 15779581
    The aim of the study was: to obtain the profile of patients (with regards to age and family history of breast cancer) with a palpable breast mass. To determine the validity of ultrasound in the assessment of the palpable breast mass by determining the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of ultrasound in distinguishing a malignant mass. To determine the most discriminating ultrasound characteristics for differentiating benign and malignant masses. Seventy patients who had fine needle aspiration cytology of a palpable breast mass were subjected to an ultrasound assessment of the mass. The ultrasound findings were classified as benign, indeterminate or malignant. These findings were then compared with either the cytology or histology results in cases that eventually had surgical excision. The age of the patients ranged from 15 to 66 years old The majority was in the third and fourth decades with an average age of 25 years. The 8 patients with a proven malignant breast mass were aged between 39 and 66 years old. They did not have any family history of breast cancer. Only 4 patients had a family history of breast carcinoma and all proved to have a benign breast lesion. Ultrasound had a sensitivity of 100%, specificity of 85.7%, positive predictive value of 50%, negative predictive value of 100% and accuracy of 87.5% for distinguishing a malignant mass. For benign masses: 93.7% had well-defined margins, 81.3% had homogenous internal echoes, 91.7% had depth-width ratio of less than 1.0 and 89% were compressible. For malignant masses: 87.5% had either ill-defined or irregular margins, 87.5% had inhomogenous internal echoes and mixed posterior echoes, and 100% were incompressible. The majority of patients with a palpable breast mass were aged below 40 years old. Most of the patients with a malignant breast mass were aged 40 years and older. Neither a positive nor a negative family history of breast cancer had any significance on outcome. Ultrasound had high sensitivity, specificity and accuracy in distinguishing a malignant mass. The most discriminating benign ultrasound characteristic was compressibility. The most discriminating malignant ultrasound characteristic was ill-defined and irregular margins.
    Matched MeSH terms: Sensitivity and Specificity
  19. Jahanfar S, Ho JJ, Jaafar SH, Abraha I, Noura M, Ross CR, et al.
    Cochrane Database Syst Rev, 2021 03 09;3:CD012553.
    PMID: 33686672 DOI: 10.1002/14651858.CD012553.pub2
    BACKGROUND: There is a need to standardize monitoring in obstetric research of twin pregnancies. Identification of birth weight discordance (BWD), defined as a difference in the birth weights of twins, is a well-documented phenomenon in twin pregnancies. Ultrasound for the diagnosis of BWD informs complex decision making including whether to intervene medically (via laser photo coagulation) or deliver the twins to avoid fetal morbidities or even death. The question is, how accurate is this measurement?

    OBJECTIVES: To determine the diagnostic accuracy (sensitivity and specificity) of ultrasound estimated fetal weight discordance (EFWD) of 20% and 25% using different estimated biometric ultrasound measurements compared with the actual BWD as the reference standard in twin pregnancies.

    SEARCH METHODS: The search for this review was performed on 15 March 2019. We searched CENTRAL, MEDLINE (Ovid), Embase (Ovid), seven other databases, conference proceedings, reference lists and contacted experts. There were no language or date restrictions applied to the electronic searches, and no methodological filters to maximize sensitivity.

    SELECTION CRITERIA: We selected cohort-type studies with delayed verification that evaluated the accuracy of biometric measurements at ultrasound scanning of twin pregnancies that had been proposed for the diagnosis of estimated BWD, compared to BWD measurements after birth as a reference standard. In addition, we only selected studies that considered twin pregnancies and applied a reference standard for EFWD for the target condition of BWD.

    DATA COLLECTION AND ANALYSIS: We screened all titles generated by electronic database searches. Two review authors independently assessed the abstracts of all potentially relevant studies. We assessed the identified full papers for eligibility, and extracted data to create 2 × 2 tables. Two review authors independently performed quality assessment using the QUADAS-2 tool. We excluded studies that did not report data in sufficient detail to construct 2 × 2 tables, and where this information was not available from the primary investigators. We assessed the certainty of the evidence using the GRADE approach.

    MAIN RESULTS: We included 39 eligible studies with a median study sample size of 140. In terms of risk of bias, there were many unclear statements regarding patient selection, index test and use of proper reference standard. Twenty-one studies (53%) were of methodological concern due to flow and timing. In terms of applicability, most studies were of low concern. Ultrasound for diagnosis of BWD in twin pregnancies at 20% cut-off Twenty-two studies provided data for a BWD of 20% and the summary estimate of sensitivity was 0.51 (95% CI 0.42 to 0.60), and the summary estimate of specificity was 0.91 (95% CI 0.89 to 0.93) (8005 twin pregnancies; very low-certainty evidence). Ultrasound for diagnosis of BWD in twin pregnancies at 25% cut-off Eighteen studies provided data using a BWD discordance of 25%. The summary estimate of sensitivity was 0.46 (95% CI 0.26 to 0.66), and the summary estimate of specificity was 0.93 (95% CI 0.89 to 0.96) (6471 twin pregnancies; very low-certainty evidence). Subgroup analyses were possible for both BWD of 20% and 25%. The diagnostic accuracy did not differ substantially between estimation by abdominal circumference and femur length but femur length had a trend towards higher sensitivity and specificity. Subgroup analyses were not possible by sex of twins, chorionicity or gestational age due to insufficient data.

    AUTHORS' CONCLUSIONS: Very low-certainty evidence suggests that EFWD identified by ultrasound has low sensitivity but good specificity in detecting BWD in twin pregnancies. There is uncertain diagnostic value of EFWD; this review suggests there is insufficient evidence to support this index as the sole measure for clinical decision making to evaluate the prognosis of twins with growth discordance. The diagnostic accuracy of other measures including amniotic fluid index and umbilical artery Doppler resistive indices in combination with ultrasound for clinical intervention requires evaluation. Future well-designed studies could also evaluate the impact of chorionicity, sex and gestational age in the diagnostic accuracy of ultrasound for EFWD.

    Matched MeSH terms: Sensitivity and Specificity
  20. Lee KF, Abdul Rahim A, Raja Azmi MN, Wan Hazabbah WH, Embong Z, Noramazlan R, et al.
    Med J Malaysia, 2013;68(1):39-43.
    PMID: 23466765 MyJurnal
    RetCam is an excellent screening tool for the detection of retinopathy of prematurity (ROP). However, affordability is a barrier when adopting the use of RetCam in developing countries. We aimed to describe different stages of ROP using ultrasonographic B-scan and to evaluate the association between funduscopic examinations and ultrasonographic B-scan findings in premature neonates with ROP in Malaysia. A descriptive cross sectional study was conducted in 90 eyes of 47 premature neonates with different stages of ROP in three tertiary hospitals in Malaysia. Experienced ophthalmologists performed detailed funduscopic examinations using binocular indirect ophthalmoscopy (BIO). A masked examiner performed a 10 MHz ultrasonographic B-scan evaluation with 12 meridian position images within 48 hours of clinical diagnosis. Data from the clinical examination and ultrasonographic findings were collected and analysed. We recruited 37 eyes (41.1%) with stage 1 ROP, 29 eyes (32.3%) with stage 2, 18 eyes (20.0%) with stage 3, and 3 eyes (3.3%) with stages 4 and 5 based on the clinical assessment. Ultrasonography correctly identified 3 (8.1%) stage 1 eyes, 17 (58.6%) stage 2 eyes, 13 (72.2%) stage 3 eyes, and 3 each (100%) of the stage 4 and 5 eyes. There was a significant association between the funduscopic signs and the ultrasound findings for stage 2 ROP and above (Fisher's exact test, p <0.001). In conclusion, all stages of ROP were detected and described with a 10 MHz ultrasonic B-scan system. A significant association was observed between funduscopic signs and ultrasonographic findings in premature Malaysian neonates with stage 2 ROP and above.
    Matched MeSH terms: Sensitivity and Specificity
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links