Displaying publications 41 - 60 of 97 in total

Abstract:
Sort:
  1. Sinha N, Rao BS, Trivedy PD, Rao AS
    J Orthop Surg (Hong Kong), 2016 04;24(1):139.
    PMID: 27122535
    Matched MeSH terms: Fracture Fixation, Internal
  2. Singh TS, Sadagatullah AN, Yusof AH
    Singapore Med J, 2015 Oct;56(10):562-6.
    PMID: 25814075 DOI: 10.11622/smedj.2015130
    The purpose of this study was to examine the differing curves of the volar distal radius of healthy Malaysian Malays, so as to obtain detailed morphological information that will further the understanding of volar plate osteosynthesis in Malaysian Malays.
    Matched MeSH terms: Fracture Fixation, Internal
  3. Shanmugam R, Ernst M, Stoffel K, Fischer MF, Wahl D, Richards RG, et al.
    Clin Biomech (Bristol, Avon), 2015 Jun;30(5):405-10.
    PMID: 25846324 DOI: 10.1016/j.clinbiomech.2015.03.019
    Dorsal plating is commonly used in proximal phalanx fractures but it bears the risk of interfering with the extensor apparatus. In this study, dorsal and lateral plating fixation methods are compared to assess biomechanical differences using conventional 1.5mm non-locking plates and novel 1.3mm lateral locking plates.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*; Fracture Fixation, Internal/methods*
  4. Anuar-Ramdhan IM, Azahari IM, Med Orth M
    Malays Orthop J, 2014 Nov;8(3):33-6.
    PMID: 26401234 MyJurnal DOI: 10.5704/MOJ.1411.008
    The diaphyseal tibia fracture is best treated with intramedullary nail but in some cases where the nail is not applicable, plate fixation will be the next option of fixation. The extensile anterior approach is normally used for conventional compression plate fixation in tibia shaft fractures. The extensive surgical dissection may devitalizes the bony fragments and interfere with the fracture union as well as soft tissue healing. Minimally Invasive Plate Osteosynthesis (MIPO) provides good preservation of blood supply and fracture hematoma at the fracture site thus promotes biological bone healing. The use of indirect reduction techniques and small skin incisions to introduce the plate is technically demanding and requires fluoroscopy exposures throughout the surgery, being some of its drawbacks. We recommend MIPO for conventional compression plate fixation in tibial shaft fractures in view of the reduced surgical trauma to the surrounding soft tissue and good functional outcome.
    Matched MeSH terms: Fracture Fixation, Internal
  5. Anizar-Faizi A, Hisam A, Sudhagar KP, Moganadass M, Suresh C
    Malays Orthop J, 2014 Nov;8(3):1-6.
    PMID: 26401227 MyJurnal DOI: 10.5704/MOJ.1411.001
    The aim of this study was to assess the outcome of surgical treatment in displaced acetabular fractures in our local facilities. Previous studies reveal good outcome via open reduction method with achievement of congruent joint. We note that studies in this respect have not been conducted in our region. We retrospectively analyzed thirty patients with acetabular fractures who underwent open reduction and internal fixation. The data collection was performed over a 4-year period, from 2008 to 2011. The results showed 20 out of 30 patients (66.7%) had excellent/good results (Harris Hip Score equal or more than 80). Post operative complications were deep infection (6.7%), iatrogenic sciatic nerve injury (10.0%), avascular necrosis (16.7%), heterotopic ossificans (3.3%), degenerative changes in hip joint (43.3%) and loss of reduction (3.3%). In conclusion, surgical treatment of displaced acetabular fractures produces good functional outcome despite the complications.
    Matched MeSH terms: Fracture Fixation, Internal
  6. Mirzasadeghi A, Narayanan SS, Ng MH, Sanaei R, Cheng CH, Bajuri MY, et al.
    Biomed Mater Eng, 2014;24(6):2177-86.
    PMID: 25226916 DOI: 10.3233/BME-141029
    The application of bone substitutes and cements has a long standing history in augmenting fractures as a complement to routine fracture fixation techniques. Nevertheless, such use is almost always in conjunction with definite means of fracture fixation such as intramedullary pins or bone plates. The idea of using biomaterials as the primary fixation bears the possibility of simultaneous fixation and bone enhancement. Intramedullary recruitment of bone cements is suggested in this study to achieve this goal. However, as the method needs primary testings in animal models before human implementation, and since the degree of ambulation is not predictable in animals, this pilot study only evaluates the outcomes regarding the feasibility and safety of this method in the presence of primary bone fixators. A number of two sheep were used in this study. Tibial transverse osteotomies were performed in both animals followed by external skeletal fixation. The medullary canals, which have already been prepared by removing the marrow through proximal and distal drill holes, were then injected with calcium phosphate cement (CPC). The outcomes were evaluated postoperatively by standard survey radiographs, morphology, histology and biomechanical testings. Healing processes appeared uncomplicated until week four where one bone fracture recurred due to external fixator failure. The results showed 56% and 48% cortical thickening, compared to the opposite site, in the fracture site and proximal and distal diaphyses respectively. This bone augmentative effect resulted in 264% increase in bending strength of the fracture site and 148% increase of the same value in the adjacent areas of diaphyses. In conclusion, IMCO, using CPC in tibia of sheep, is safe and biocompatible with bone physiology and healing. It possibly can carry the osteopromotive effect of the CPCs to provide a sustained source of bone augmentation throughout the diaphysis. Although the results must be considered preliminary, this method has possible advantages over conventional methods of bone fixation at least in bones with compromised quality (i.e. osteoporosis and bone cysts), where rigid metal implants may jeopardize eggshell cortices.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*; Fracture Fixation, Internal/methods*
  7. Alizadeh M, Kadir MR, Fadhli MM, Fallahiarezoodar A, Azmi B, Murali MR, et al.
    J Orthop Res, 2013 Sep;31(9):1447-54.
    PMID: 23640802 DOI: 10.1002/jor.22376
    Posterior instrumentation is a common fixation method used to treat thoracolumbar burst fractures. However, the role of different cross-link configurations in improving fixation stability in these fractures has not been established. A 3D finite element model of T11-L3 was used to investigate the biomechanical behavior of short (2 level) and long (4 level) segmental spine pedicle screw fixation with various cross-links to treat a hypothetical L1 vertebra burst fracture. Three types of cross-link configurations with an applied moment of 7.5 Nm and 200 N axial force were evaluated. The long construct was stiffer than the short construct irrespective of whether the cross-links were used (p < 0.05). The short constructs showed no significant differences between the cross-link configurations. The XL cross-link provided the highest stiffness and was 14.9% stiffer than the one without a cross-link. The long construct resulted in reduced stress to the adjacent vertebral bodies and screw necks, with 66.7% reduction in bending stress on L2 when the XL cross-link was used. Thus, the stability for L1 burst fracture fixation was best achieved by using long segmental posterior instrumentation constructs and an XL cross-link configuration. Cross-links did not improved stability when a short structure was used.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*; Fracture Fixation, Internal/methods
  8. Muhammad Abdul Jamil MK, Abdul Rashid AH, Ibrahim S
    J Pediatr Orthop B, 2013 May;22(3):207-12.
    PMID: 22182834 DOI: 10.1097/BPB.0b013e32834ecc01
    This preliminary report is on two patients with congenital pseudoarthrosis of the tibia who had a persistent nonunion following intramedullary rodding and bone grafting. We do not advocate repeated surgery to achieve union. When limb length discrepancy becomes greater than 5 cm, we proceeded with an Ilizarov procedure with the primary aim of equalizing limb length rather than achieving union. Healing of the pseudoarthrosis occurred in both patients after lengthening over the intramedullary rod without compression of the nonunion site. We believe that union occurs because of hyperaemia during the lengthening. This approach minimizes the repeated surgeries that are usually needed and thus ensures a more normal childhood without frequent hospitalizations.
    Matched MeSH terms: Fracture Fixation, Internal/adverse effects*; Fracture Fixation, Internal/methods
  9. Khademolhosseini M, Abd Rashid AH, Ibrahim S
    J Pediatr Orthop B, 2013 Mar;22(2):123-6.
    PMID: 23222035 DOI: 10.1097/BPB.0b013e32835b2e14
    A retrospective study of nerve injuries with displaced supracondylar fractures of the humerus in children younger than 12 years of age, treated in Hospital Universiti Kebangsaan Malaysia. Our objectives were to determine the incidence of primary and iatrogenic nerve injuries in supracondylar humerus fractures Gartland types II and III and to determine the outcome of nerve recovery. A total of 272 patients with displaced supracondylar humerus fractures who required admission to Hospital Universiti Kebangsaan Malaysia from January 2000 to December 2007 were reviewed. There were 182 boys (67%) and 90 girls (33%). The mean age was 6.0 years, ranging from 1 to 12 years. Of 272 supracondylar fractures, 79 were type II and 193 were type III. Fifty-one (19%) patients had closed reduction, 160 (59%) had closed reduction and percutaneous crossed Kirschner (K) wires, and 61 (22%) had open reduction and crossed K-wires. Associated nerve injuries involving the median, radial, and ulnar nerves were observed in 48 (18%) patients. Nerve injuries were observed in nine (3%) patients upon admission. Thirty-nine (14%) patients developed nerve injuries following treatment. Of these 39 patients, 34 had ulnar, three had radial, and two had median nerve injuries. Nerve exploration was performed in five patients (in four patients following debridement of open fracture and in one because of unacceptable postoperative radiographs, and they subsequently underwent open reduction and exploration). Except for these five patients, the K-wires were not removed earlier nor were the nerves surgically explored in others. The nerve injuries resolved clinically on an average time of 3.5 months (range from 3 weeks to 8 months). Our study found complete resolution of all patients with nerve injuries confirmed by clinical assessment. On the basis of our study, we believe that there is no indication to remove the K-wires immediately or to explore the nerve surgically following a mini-open technique, which reduces the risk of penetrating a nerve during pinning.
    Matched MeSH terms: Fracture Fixation, Internal/adverse effects*; Fracture Fixation, Internal/instrumentation*; Fracture Fixation, Internal/methods
  10. Bajuri MY, Johan RR, Shukur H
    BMJ Case Rep, 2013;2013.
    PMID: 23576653 DOI: 10.1136/bcr-2013-008631
    Fat embolism syndrome (FES) is a continuum of fat emboli. Variants of FES: acute fulminant form and classic FES are postulated to represent two different pathomechanisms. Acute fulminant FES occurs during the first 24 h. It is attributed to massive mechanical blockage pulmonary vasculature by the fat emboli. The classic FES typically has a latency period of 24-36 h manifestation of respiratory failure and other signs of fat embolism. Progression of asymptomatic fat embolism with FES frequently represents inadequate treatment of hypovolaemic shock. We present a rare case of two variants of FES evolving in a patient with multiple fractures to emphasis the importance of adequate and appropriate treatment of shock in preventing the development of FES. Since supportive therapy which is a ventilatory support remains as the treatment of FES, it is appropriate to treat FES in the intensive care unit setting.
    Matched MeSH terms: Fracture Fixation, Internal/methods
  11. Zal U’yun Wan Mahmood, Norfaizal Mohamed @ Mohamad, Nik Azlin Nik Ariffin, Abdul Kadir Ishak
    MyJurnal
    An improved laboratory technique for measurement of polonium-210(
    210Po) in environmental
    samples has been developed in Radiochemistry and Environmental Laboratory (RAS), Malaysian
    Nuclear Agency. To further improve this technique, a study with the objectives to determine the
    optimum conditions for
    210Po deposition and; evaluate the accuracy and precision results for
    the determination of 2 1 0 P o in environmental samples was carried-out. Polonium-210 which
    is an alpha emitter obtained in acidic solution through total digestion and dissolution of samples
    has been efficiently plated onto one side of the silver disc in the spontaneous plating process for
    measurement of its alpha activity. The optimum conditions for deposition of 210Po were achieved
    using hydrochloric acid (HCl) media at acidity of 0.5 M with the presence of 1.0 gram hydroxyl
    ammonium chloride and the plating temperature at 90
    oC. The plating was carried out in 80 mL
    HCl solution (0.5 M) for 4 hours. The recorded recoveries obtained using 2 0 9 P o tracers in
    the CRM IAEA-385 and environmental samples were 85% – 98% whereby the efficiency of the
    new technique is a distinct advantage over the existing techniques. Therefore, optimization of
    deposition parameters is a prime importance to achieve accuracy and precision results as well as
    economy and time saving
    Matched MeSH terms: Fracture Fixation, Internal
  12. Afshar R, Fong TS, Latifi MH, Kanthan SR, Kamarul T
    J Hand Surg Eur Vol, 2012 Jun;37(5):396-401.
    PMID: 22019989 DOI: 10.1177/1753193411424557
    The use of bicortical screws to fix metacarpal fractures has been suggested to provide no added biomechanical advantage over unicortical screw fixation. However, this was only demonstrated in static loading regimes, which may not be representative of biological conditions. The present study was done to determine whether similar outcomes are obtained when cyclic loading is applied. Transverse midshaft osteotomies were created in 20 metacarpals harvested from three cadavers. Fractures were stabilised using 2.0 mm mini fragment plates fixed with either bicortical or unicortical screw fixation. These fixations were tested to failure with a three-point bending cyclic loading protocol using an electromechanical microtester and a 1 kN load cell. The mean load to failure was 370 N (SD 116) for unicortical fixation and 450 N (SD 135) for bicortical fixation. Significant differences between these two constructs were observed. A biomechanical advantage was found when using bicortical screws in metacarpal fracture plating.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  13. Latifi MH, Ganthel K, Rukmanikanthan S, Mansor A, Kamarul T, Bilgen M
    Biomed Eng Online, 2012;11:23.
    PMID: 22545650 DOI: 10.1186/1475-925X-11-23
    Effective fixation of fracture requires careful selection of a suitable implant to provide stability and durability. Implant with a feature of locking plate (LP) has been used widely for treating distal fractures in femur because of its favourable clinical outcome, but its potential in fixing proximal fractures in the subtrochancteric region has yet to be explored. Therefore, this comparative study was undertaken to demonstrate the merits of the LP implant in treating the subtrochancteric fracture by comparing its performance limits against those obtained with the more traditional implants; angle blade plate (ABP) and dynamic condylar screw plate (DCSP).
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*
  14. Nazri, M.Y.
    MyJurnal
    Introduction: Anterior border of the tibia is covered only by a thin layer of protective tissue. Plating of the tibia often results in wound complication and infection if the injury to this area is not recognized. We review our results of managing infection following plating of the tibia using a protocol base on the status of bone healing and the presence of bone or soft-tissue defect. Methods: Eight cases of infection following plating of the tibia were managed according to stage procedures protocols and classification, which is based on the state of bony union and the defect following wound debridement. The soft-tissue defects were managed with local flaps, and the bone defects were managed with Illizarov bone transport. Results: Three patients had more than one bacterium isolated. Gram negative organisms were isolated from seven patients. Methicillineresistant Staphylococcus aureus was isolated in two patients. All patients achieved union with a mean union
    time of seven months. The infections were controlled in seven patients. One patient had minimal sinus discharge but refused further treatment. Conclusions: The stage protocol for the management of infection following plating of the tibia is practical and produces excellent results.
    Matched MeSH terms: Fracture Fixation, Internal
  15. Sulaiman AR, Munajat I, Mohd EF
    J Pediatr Orthop B, 2011 Nov;20(6):366-71.
    PMID: 21716140 DOI: 10.1097/BPB.0b013e32834920df
    Operative treatment for neglected fracture of lateral humeral condyle (LHC) is difficult because of contracted muscle, fibrous tissue formation, and indistinct bony edges. Its success depends on the ability to preserve blood supply during the surgery. We retrospectively reviewed eight cases of neglected fracture of LHC in children treated with open reduction with selected multiple 'V' lengthening of common extensor muscle and internal fixation. The patients were between 3 and 8 years of age. The period of neglect was between 3 and 20 weeks. Four patients with displacement of more than 10 mm and neglect for 5 weeks or more required lengthening of common extensor muscle aponeurosis. The follow-up assessments were between 1 and 6.3 years with a mean of 4.4 years. All patients had union by 2 months. They gained improvement of flexion range of motion between 60° and 120° with a mean of 86.3°. Loss of final range of motion compared with the normal side was between 5° and 35° with a mean of 10°. No patient had limitation of activities or pain. Six cases had excellent and two cases had good Dillon functional score. All patients had lateral condyle prominent with different severities. There was one mild avascular necrosis and one fishtail deformity. Both of them had almost full range of motion. All patients had early physeal closure, except one, who had only 1 year follow-up. There was no case of progressive valgus deformity. Children with neglected fracture of LHC would benefit from anatomical reduction and internal fixation through a proper exposure and if indicated combined with multiple 'V' lengthening of common extensor muscle aponeurosis. This is a level IV study.
    Matched MeSH terms: Fracture Fixation, Internal/methods*
  16. Miswan MF, Singh VA, Yasin NF
    Ulus Travma Acil Cerrahi Derg, 2011 Nov;17(6):504-8.
    PMID: 22290002 DOI: 10.5505/tjtes.2011.04809
    We reviewed cases with Lisfranc injuries who presented to our center in order to study the adequacy of the treatment method and their final functional outcome.
    Matched MeSH terms: Fracture Fixation, Internal/statistics & numerical data*
  17. Malays Orthop J, 2011;5(2):24-27.
    MyJurnal
    The objective of this study was to assess the rate of screw cut out in elderly patients treated with the dynamic hip screw and the relationship to the Tip Apex Distance (TAD). This is a retrospective radiological evaluation of 100 cases of elderly patients with intertrochanteric fracture treated with dynamic hip screw fixation surgically treated between 1998 and 2002. The incidence of screw cut out was assessed and correlation of risk of cut out with the TAD was assessed. The rate of screw cut out was 9.0% and the average length of time to screw cut out was 3.8 months (range, 1 to 6 months) postoperatively. The incidence of screw cut out increased significantly when the TAD was 20 mm or more. The screw cut out rates were 2.9%, 20.0%, 30.8%, 50% and 100% for TAD of 20-24 mm, 25-29 mm, 30-34 mm, 35-44 mm and > 45 mm respectively. Overall, a TAD of 20mm or more was associated with a statistically significant screw cut out risk in this Malaysian population
    Matched MeSH terms: Fracture Fixation, Internal
  18. Yusof NM, Oh CW, Oh JK, Kim JW, Min WK, Park IH, et al.
    Injury, 2009 Dec;40(12):1286-91.
    PMID: 19539282 DOI: 10.1016/j.injury.2009.02.020
    Although non-operative treatment is a mainstay of tibial fracture management in children, certain fractures require a surgical approach. However, choices concerning optimal methods and implants are difficult. The purpose of this study was to determine the effectiveness of percutaneous plating of tibial fractures in children.
    Matched MeSH terms: Fracture Fixation, Internal/methods*
  19. Abdul-Rahman MR, Seong NK, Hee TG, Aljada ME, Reda TA, Sumin JO, et al.
    Heart Surg Forum, 2009 Jun;12(3):E184-6.
    PMID: 19546075 DOI: 10.1532/HSF98.20091016
    Various techniques of sternal stabilization via either metal plates or wires have been described. We describe an alternative technique of simple median sternotomy followed by reduction and wire fixation of the sternal fracture. The 2 patients described in this report had traumatic comminuted and displaced sternal fractures. Even though wire repair was deemed to be tedious and achieved poor approximation of the bone, we performed median sternotomy and achieved simple wire fixation with an excellent result.
    Matched MeSH terms: Fracture Fixation, Internal/instrumentation*; Fracture Fixation, Internal/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links