Displaying publications 41 - 60 of 110 in total

Abstract:
Sort:
  1. Tan MK, Siddiqi A, Yeo LY
    Sci Rep, 2017 07 27;7(1):6652.
    PMID: 28751783 DOI: 10.1038/s41598-017-07025-x
    The Miniaturised Lab-on-a-Disc (miniLOAD) platform, which utilises surface acoustic waves (SAWs) to drive the rotation of thin millimeter-scale discs on which microchannels can be fabricated and hence microfluidic operations can be performed, offers the possibility of miniaturising its larger counterpart, the Lab-on-a-CD, for true portability in point-of-care applications. A significant limitation of the original miniLOAD concept, however, is that it does not allow for flexible control over the disc rotation direction and speed without manual adjustment of the disc's position, or the use of multiple devices to alter the SAW frequency. In this work, we demonstrate the possibility of achieving such control with the use of tapered interdigitated transducers to confine a SAW beam such that the localised acoustic streaming it generates imparts a force, through hydrodynamic shear, at a specific location on the disc. Varying the torque that arises as a consequence by altering the input frequency to the transducers then allows the rotational velocity and direction of the disc to be controlled with ease. We derive a simple predictive model to illustrate the principle by which this occurs, which we find agrees well with the experimental measurements.
    Matched MeSH terms: Hydrodynamics
  2. Kamangar S, Badruddin IA, Badarudin A, Nik-Ghazali N, Govindaraju K, Salman Ahmed NJ, et al.
    Comput Methods Biomech Biomed Engin, 2017 Mar;20(4):365-372.
    PMID: 27612619 DOI: 10.1080/10255842.2016.1233402
    The current study investigates the hyperemic flow effects on heamodynamics parameters such as velocity, wall shear stress in 3D coronary artery models with and without stenosis. The hyperemic flow is used to evaluate the functional significance of stenosis in the current era. Patients CT scan data of having healthy and coronary artery disease was chosen for the reconstruction of 3D coronary artery models. The diseased 3D models of coronary artery shows a narrowing of >50% lumen area. Computational fluid dynamics was performed to simulate the hyperemic flow condition. The results showed that the recirculation zone was observed immediate to the stenosis and highest wall shear stress was observed across the stenosis. The decrease in pressure was found downstream to the stenosis as compared to the coronary artery without stenosis. Our analysis provides an insight into the distribution of wall shear stress and pressure drop, thus improving our understanding of hyperemic flow effect under both conditions.
    Matched MeSH terms: Hydrodynamics
  3. Kamangar S, Nik-Ghazali N, Badarudin A, Ameer Ahamad N, Irfan Anjum Badruddin, Govindaraju K, et al.
    Sains Malaysiana, 2017;46:1923-1933.
    The present work was carried out to investigate the blood flow behavior and the severity of blockage caused in the
    arterial passage due to the different geometries such as elliptical, trapezium and triangular shapes of stenosis. The study
    was conducted with respect to various sizes of stenosis in terms of 70%, 80% and 90% area blockage of the arterial
    blood flow. The study was carried out numerically with the help of advance computational fluid dynamic software. It
    was found that the shape of the stenosis plays an important role in overall pressure drop across the blockage region
    of artery. The highest level of pressure drop was observed for trapezoidal shape of stenosis followed by elliptical and
    then by triangular shaped stenosis. The wall shear stress across the stenosis is great for trapezoidal shape followed by
    triangular and elliptical stenosis for same blockage area in the artery.
    Matched MeSH terms: Hydrodynamics
  4. Mirza IA, Abdulhameed M, Vieru D, Shafie S
    Comput Methods Programs Biomed, 2016 Dec;137:149-166.
    PMID: 28110721 DOI: 10.1016/j.cmpb.2016.09.014
    Therapies with magnetic/electromagnetic field are employed to relieve pains or, to accelerate flow of blood-particles, particularly during the surgery. In this paper, a theoretical study of the blood flow along with particles suspension through capillary was made by the electro-magneto-hydrodynamic approach. Analytical solutions to the non-dimensional blood velocity and non-dimensional particles velocity are obtained by means of the Laplace transform with respect to the time variable and the finite Hankel transform with respect to the radial coordinate. The study of thermally transfer characteristics is based on the energy equation for two-phase thermal transport of blood and particles suspension with viscous dissipation, the volumetric heat generation due to Joule heating effect and electromagnetic couple effect. The solution of the nonlinear heat transfer problem is derived by using the velocity field and the integral transform method. The influence of dimensionless system parameters like the electrokinetic width, the Hartman number, Prandtl number, the coefficient of heat generation due to Joule heating and Eckert number on the velocity and temperature fields was studied using the Mathcad software. Results are presented by graphical illustrations.
    Matched MeSH terms: Hydrodynamics*
  5. Govindaraju K, Viswanathan GN, Badruddin IA, Kamangar S, Salman Ahmed NJ, Al-Rashed AA
    Comput Methods Biomech Biomed Engin, 2016 Nov;19(14):1541-9.
    PMID: 27052093 DOI: 10.1080/10255842.2016.1170119
    This study aims to investigate the influence of artery wall curvature on the anatomical assessment of stenosis severity and to identify a region of misinterpretation in the assessment of per cent area stenosis (AS) for functionally significant stenosis using fractional flow reserve (FFR) as standard. Five artery models of different per cent AS severity (70, 75, 80, 85 and 90%) were considered. For each per cent AS severity, the angle of curvature of the arterial wall varied from straight to an increasingly curved model (0°, 30°, 60°, 90° and 120°). Computational fluid dynamics was performed under transient physiologic hyperemic flow conditions to investigate the influence of artery wall curvature on the pressure drop and the FFR. The findings in this study may be useful in in vitro anatomical assessment of functionally significant stenosis. The FFR decreased with increasing stenosis severity for a given curvature of the artery wall. Moreover, a significant decrease in FFR was found between straight and curved models discussed for a given severity condition. These findings indicate that the curvature effect was included in the FFR assessment in contrast to minimum lumen area (MLA) or per cent AS assessment. The MLA or per cent AS assessment may lead to underestimation of stenosis severity. From this numerical study, an uncertainty region could be evaluated using the clinical FFR cutoff value of 0.8. This value was observed at 81.98 and 79.10% AS for arteries with curvature angles of 0° and 120° respectively. In conclusion, the curvature of the artery should not be neglected in in vitro anatomical assessment.
    Matched MeSH terms: Hydrodynamics*
  6. Sia SF, Zhao X, Li R, Zhang Y, Chong W, He L, et al.
    Proc Inst Mech Eng H, 2016 Nov;230(11):1051-1058.
    PMID: 28095764 DOI: 10.1177/0954411916671752
    BACKGROUND: Internal carotid artery stenosis requires an accurate risk assessment for the prevention of stroke. Although the internal carotid artery area stenosis ratio at the common carotid artery bifurcation can be used as one of the diagnostic methods of internal carotid artery stenosis, the accuracy of results would still depend on the measurement techniques. The purpose of this study is to propose a novel method to estimate the effect of internal carotid artery stenosis on the blood flow based on the concept of minimization of energy loss.

    METHODS: Eight internal carotid arteries from different medical centers were diagnosed as stenosed internal carotid arteries, as plaques were found at different locations on the vessel. A computational fluid dynamics solver was developed based on an open-source code (OpenFOAM) to test the flow ratio and energy loss of those stenosed internal carotid arteries. For comparison, a healthy internal carotid artery and an idealized internal carotid artery model have also been tested and compared with stenosed internal carotid artery in terms of flow ratio and energy loss.

    RESULTS: We found that at a given common carotid artery bifurcation, there must be a certain flow distribution in the internal carotid artery and external carotid artery, for which the total energy loss at the bifurcation is at a minimum; for a given common carotid artery flow rate, an irregular shaped plaque at the bifurcation constantly resulted in a large value of minimization of energy loss. Thus, minimization of energy loss can be used as an indicator for the estimation of internal carotid artery stenosis.

    Matched MeSH terms: Hydrodynamics
  7. Tiang KL, Ooi EH
    Med Eng Phys, 2016 Aug;38(8):776-84.
    PMID: 27340100 DOI: 10.1016/j.medengphy.2016.05.011
    The majority of the eye models developed in the late 90s and early 00s considers only heat conduction inside the eye. This assumption is not entirely correct, since the anterior and posterior chambers are filled aqueous humor (AH) that is constantly in motion due to thermally-induced buoyancy. In this paper, a three-dimensional model of the human eye is developed to investigate the effects AH hydrodynamics have on the human eye temperature under exposure to external heat sources. If the effects of AH flow are negligible, then future models can be developed without taking them into account, thus simplifying the modeling process. Two types of external thermal loads are considered; volumetric and surface irradiation. Results showed that heat convection due to AH flow contributes to nearly 95% of the total heat flow inside the anterior chamber. Moreover, the circulation inside the anterior chamber can cause an upward shift of the location of hotspot. This can have significant consequences to our understanding of heat-induced cataractogenesis.
    Matched MeSH terms: Hydrodynamics*
  8. Thang LY, Breadmore MC, See HH
    J Chromatogr A, 2016 Jul 27.
    PMID: 27485148 DOI: 10.1016/j.chroma.2016.07.067
    An online preconcentration method, namely electrokinetic supercharging (EKS), was evaluated for the determination of tamoxifen and its metabolites in human plasma in nonaqueous capillary electrophoresis with ultraviolet detection (NACE-UV). This method was comprehensively optimized in terms of the leading electrolyte (LE) and terminating electrolyte (TE) injection lengths, as well as electrokinetic sample injection time. The optimized EKS conditions employed were as follows: hydrodynamic injection (HI) of 10mM potassium chloride as LE at 150mbar for 36s (4% of total capillary volume). The sample was injected at 10kV for 300s, followed by HI of 10mM pimozide as TE at 150mbar for 36s (4% of total capillary volume). Separation was performed in 7.5mM deoxycholic acid sodium salt, 15mM acetic acid and 1mM 18-crown-6 in 100% methanol at +25kV with UV detection at 205nm. Under optimized conditions, the sensitivity was enhanced between 160- and 600-fold when compared with our previously developed method based on HI at 150mbar for 12s. The detection limit of the method for tamoxifen and its metabolites were 0.05-0.25ng/mL, with RSDs between 2.1% and 3.5%. Recoveries in spiked human plasma were 95.6%-99.7%. A comparison was also made between the proposed EKS approach and the standard field-amplified sample injection (FASI) technique. EKS proved to be 3-5 times more sensitive than the FASI. The new EKS method was applied to the analysis of tamoxifen and its metabolites in plasma samples from breast cancer patients after liquid-liquid extraction.
    Matched MeSH terms: Hydrodynamics
  9. Jakir Hossain Khan M, Azlan Hussain M, Mujtaba IM
    Polymers (Basel), 2016 Jun 14;8(6).
    PMID: 30979325 DOI: 10.3390/polym8060220
    In this study, a novel multiphasic model for the calculation of the polypropylene production in a complicated hydrodynamic and the physiochemical environments has been formulated, confirmed and validated. This is a first research attempt that describes the development of the dual-phasic phenomena, the impact of the optimal process conditions on the production rate of polypropylene and the fluidized bed dynamic details which could be concurrently obtained after solving the model coupled with the CFD (computational fluid dynamics) model, the basic mathematical model and the moment equations. Furthermore, we have established the quantitative relationship between the operational condition and the dynamic gas⁻solid behavior in actual reaction environments. Our results state that the proposed model could be applied for generalizing the production rate of the polymer from a chemical procedure to pilot-scale chemical reaction engineering. However, it was assumed that the solids present in the bubble phase and the reactant gas present in the emulsion phase improved the multiphasic model, thus taking into account that the polymerization took place mutually in the emulsion besides the bubble phase. It was observed that with respect to the experimental extent of the superficial gas velocity and the Ziegler-Natta feed rate, the ratio of the polymer produced as compared to the overall rate of production was approximately in the range of 9%⁻11%. This is a significant amount and it should not be ignored. We also carried out the simulation studies for comparing the data of the CFD-dependent dual-phasic model, the emulsion phase model, the dynamic bubble model and the experimental results. It was noted that the improved dual-phasic model and the CFD model were able to predict more constricted and safer windows at similar conditions as compared to the experimental results. Our work is unique, as the integrated developed model is able to offer clearer ideas related to the dynamic bed parameters for the separate phases and is also capable of computing the chemical reaction rate for every phase in the reaction. Our improved mutiphasic model revealed similar dynamic behaviour as the conventional model in the initial stages of the polymerization reaction; however, it diverged as time progressed.
    Matched MeSH terms: Hydrodynamics
  10. Bokhari A, Chuah LF, Yusup S, Klemeš JJ, Kamil RNM
    Bioresour Technol, 2016 Jan;199:414-422.
    PMID: 26298387 DOI: 10.1016/j.biortech.2015.08.013
    Pretreatment of the high free fatty acid rubber seed oil (RSO) via esterification reaction has been investigated by using a pilot scale hydrodynamic cavitation (HC) reactor. Four newly designed orifice plate geometries are studied. Cavities are induced by assisted double diaphragm pump in the range of 1-3.5 bar inlet pressure. An optimised plate with 21 holes of 1mm diameter and inlet pressure of 3 bar resulted in RSO acid value reduction from 72.36 to 2.64 mg KOH/g within 30 min of reaction time. Reaction parameters have been optimised by using response surface methodology and found as methanol to oil ratio of 6:1, catalyst concentration of 8 wt%, reaction time of 30 min and reaction temperature of 55°C. The reaction time and esterified efficiency of HC was three fold shorter and four fold higher than mechanical stirring. This makes the HC process more environmental friendly.
    Matched MeSH terms: Hydrodynamics
  11. Saifullah B, El Zowalaty ME, Arulselvan P, Fakurazi S, Webster TJ, Geilich BM, et al.
    Int J Nanomedicine, 2016;11:3225-37.
    PMID: 27486322 DOI: 10.2147/IJN.S102406
    The chemotherapy for tuberculosis (TB) is complicated by its long-term treatment, its frequent drug dosing, and the adverse effects of anti-TB drugs. In this study, we have developed two nanocomposites (A and B) by intercalating the anti-TB drug isoniazid (INH) into Zn/Al-layered double hydroxides. The average size of the nanocomposites was found to bê164 nm. The efficacy of the Zn/Al-layered double hydroxides intercalated INH against Mycobacterium tuberculosis was increased by approximately three times more than free INH. The nanocomposites were also found to be active against Gram-positive and -negative bacteria. Compared to the free INH, the nanodelivery formulation was determined to be three times more biocompatible with human normal lung fibroblast MRC-5 cells and 3T3 fibroblast cells at a very high concentration of 50 µg/mL for up to 72 hours. The in vitro release of INH from the Zn/Al-layered double hydroxides was found to be sustained in human body-simulated buffer solutions of pH 4.8 and 7.4. This research is a step forward in making the TB chemotherapy patient friendly.
    Matched MeSH terms: Hydrodynamics
  12. Alvankarian J, Majlis BY
    Sensors (Basel), 2015 Nov 24;15(11):29685-701.
    PMID: 26610519 DOI: 10.3390/s151129685
    The adjustable microfluidic devices that have been developed for hydrodynamic-based fractionation of beads and cells are important for fast performance tunability through interaction of mechanical properties of particles in fluid flow and mechanically flexible microstructures. In this review, the research works reported on fabrication and testing of the tunable elastomeric microfluidic devices for applications such as separation, filtration, isolation, and trapping of single or bulk of microbeads or cells are discussed. Such microfluidic systems for rapid performance alteration are classified in two groups of bulk deformation of microdevices using external mechanical forces, and local deformation of microstructures using flexible membrane by pneumatic pressure. The main advantage of membrane-based tunable systems has been addressed to be the high capability of integration with other microdevice components. The stretchable devices based on bulk deformation of microstructures have in common advantage of simplicity in design and fabrication process.
    Matched MeSH terms: Hydrodynamics
  13. Tijani HI, Abdullah N, Yuzir A, Ujang Z
    Bioresour Technol, 2015 Jun;186:276-85.
    PMID: 25836036 DOI: 10.1016/j.biortech.2015.02.107
    The structural and hydrodynamic features for granules were characterized using settling experiments, predefined mathematical simulations and ImageJ-particle analyses. This study describes the rheological characterization of these biologically immobilized aggregates under non-Newtonian flows. The second order dimensional analysis defined as D2=1.795 for native clusters and D2=1.099 for dewatered clusters and a characteristic three-dimensional fractal dimension of 2.46 depicts that these relatively porous and differentially permeable fractals had a structural configuration in close proximity with that described for a compact sphere formed via cluster-cluster aggregation. The three-dimensional fractal dimension calculated via settling-fractal correlation, U∝l(D) to characterize immobilized granules validates the quantitative measurements used for describing its structural integrity and aggregate complexity. These results suggest that scaling relationships based on fractal geometry are vital for quantifying the effects of different laminar conditions on the aggregates' morphology and characteristics such as density, porosity, and projected surface area.
    Matched MeSH terms: Hydrodynamics
  14. Ul-Haque A, Asrar W, Omar AA, Sulaeman E, Mohamed Ali JS
    J Exp Biol, 2015 Apr 15;218(Pt 8):1270-1.
    PMID: 25911735 DOI: 10.1242/jeb.117556
    Matched MeSH terms: Hydrodynamics
  15. Mansur S, Ishak A, Pop I
    PLoS One, 2015;10(3):e0117733.
    PMID: 25760733 DOI: 10.1371/journal.pone.0117733
    The magnetohydrodynamic (MHD) stagnation point flow of a nanofluid over a permeable stretching/shrinking sheet is studied. Numerical results are obtained using boundary value problem solver bvp4c in MATLAB for several values of parameters. The numerical results show that dual solutions exist for the shrinking case, while for the stretching case, the solution is unique. A stability analysis is performed to determine the stability of the dual solutions. For the stable solution, the skin friction is higher in the presence of magnetic field and increases when the suction effect is increased. It is also found that increasing the Brownian motion parameter and the thermophoresis parameter reduces the heat transfer rate at the surface.
    Matched MeSH terms: Hydrodynamics*
  16. Chan BT, Lim E, Ong CW, Abu Osman NA
    PMID: 23521137 DOI: 10.1080/10255842.2013.779683
    Despite the advancement of cardiac imaging technologies, these have traditionally been limited to global geometrical measurements. Computational fluid dynamics (CFD) has emerged as a reliable tool that provides flow field information and other variables essential for the assessment of the cardiac function. Extensive studies have shown that vortex formation and propagation during the filling phase acts as a promising indicator for the diagnosis of the cardiac health condition. Proper setting of the boundary conditions is crucial in a CFD study as they are important determinants, that affect the simulation results. In this article, the effect of different transmitral velocity profiles (parabolic and uniform profile) on the vortex formation patterns during diastole was studied in a ventricle with dilated cardiomyopathy (DCM). The resulting vortex evolution pattern using the uniform inlet velocity profile agreed with that reported in the literature, which revealed an increase in thrombus risk in a ventricle with DCM. However the application of a parabolic velocity profile at the inlet yields a deviated vortical flow pattern and overestimates the propagation velocity of the vortex ring towards the apex of the ventricle. This study highlighted that uniform inlet velocity profile should be applied in the study of the filling dynamics in a left ventricle because it produces results closer to that observed experimentally.
    Matched MeSH terms: Hydrodynamics*
  17. Khalili AA, Ahmad MR
    Int J Mol Sci, 2015;16(11):26770-85.
    PMID: 26569218 DOI: 10.3390/ijms161125987
    Single-cell analysis has become the interest of a wide range of biological and biomedical engineering research. It could provide precise information on individual cells, leading to important knowledge regarding human diseases. To perform single-cell analysis, it is crucial to isolate the individual cells before further manipulation is carried out. Recently, microfluidic biochips have been widely used for cell trapping and single cell analysis, such as mechanical and electrical detection. This work focuses on developing a finite element simulation model of single-cell trapping system for any types of cells or particles based on the hydrodynamic flow resistance (Rh) manipulations in the main channel and trap channel to achieve successful trapping. Analysis is carried out using finite element ABAQUS-FEA™ software. A guideline to design and optimize single-cell trapping model is proposed and the example of a thorough optimization analysis is carried out using a yeast cell model. The results show the finite element model is able to trap a single cell inside the fluidic environment. Fluid's velocity profile and streamline plots for successful and unsuccessful single yeast cell trapping are presented according to the hydrodynamic concept. The single-cell trapping model can be a significant important guideline in designing a new chip for biomedical applications.
    Matched MeSH terms: Hydrodynamics
  18. Gul T, Islam S, Shah RA, Khalid A, Khan I, Shafie S
    PLoS One, 2015;10(7):e0126698.
    PMID: 26147287 DOI: 10.1371/journal.pone.0126698
    This paper studies the unsteady magnetohydrodynamics (MHD) thin film flow of an incompressible Oldroyd-B fluid over an oscillating inclined belt making a certain angle with the horizontal. The problem is modeled in terms of non-linear partial differential equations with some physical initial and boundary conditions. This problem is solved for the exact analytic solutions using two efficient techniques namely the Optimal Homotopy Asymptotic Method (OHAM) and Homotopy Perturbation Method (HPM). Both of these solutions are presented graphically and compared. This comparison is also shown in tabular form. An excellent agreement is observed. The effects of various physical parameters on velocity have also been studied graphically.
    Matched MeSH terms: Hydrodynamics*
  19. Setu SA, Dullens RP, Hernández-Machado A, Pagonabarraga I, Aarts DG, Ledesma-Aguilar R
    Nat Commun, 2015;6:7297.
    PMID: 26073752 DOI: 10.1038/ncomms8297
    Understanding fluid dynamics under extreme confinement, where device and intrinsic fluid length scales become comparable, is essential to successfully develop the coming generations of fluidic devices. Here we report measurements of advancing fluid fronts in such a regime, which we dub superconfinement. We find that the strong coupling between contact-line friction and geometric confinement gives rise to a new stability regime where the maximum speed for a stable moving front exhibits a distinctive response to changes in the bounding geometry. Unstable fronts develop into drop-emitting jets controlled by thermal fluctuations. Numerical simulations reveal that the dynamics in superconfined systems is dominated by interfacial forces. Henceforth, we present a theory that quantifies our experiments in terms of the relevant interfacial length scale, which in our system is the intrinsic contact-line slip length. Our findings show that length-scale overlap can be used as a new fluid-control mechanism in strongly confined systems.
    Matched MeSH terms: Hydrodynamics
  20. Uddin MJ, Khan WA, Ismail AI
    PLoS One, 2015;10(5):e0122663.
    PMID: 25933066 DOI: 10.1371/journal.pone.0122663
    Taking into account the effect of constant convective thermal and mass boundary conditions, we present numerical solution of the 2-D laminar g-jitter mixed convective boundary layer flow of water-based nanofluids. The governing transport equations are converted into non-similar equations using suitable transformations, before being solved numerically by an implicit finite difference method with quasi-linearization technique. The skin friction decreases with time, buoyancy ratio, and thermophoresis parameters while it increases with frequency, mixed convection and Brownian motion parameters. Heat transfer rate decreases with time, Brownian motion, thermophoresis and diffusion-convection parameters while it increases with the Reynolds number, frequency, mixed convection, buoyancy ratio and conduction-convection parameters. Mass transfer rate decreases with time, frequency, thermophoresis, conduction-convection parameters while it increases with mixed convection, buoyancy ratio, diffusion-convection and Brownian motion parameters. To the best of our knowledge, this is the first paper on this topic and hence the results are new. We believe that the results will be useful in designing and operating thermal fluids systems for space materials processing. Special cases of the results have been compared with published results and an excellent agreement is found.
    Matched MeSH terms: Hydrodynamics*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links