Displaying publications 41 - 60 of 72 in total

Abstract:
Sort:
  1. Sakulchit T, Ngu L, Chor YK, Ong GY
    Cureus, 2021 Mar 08;13(3):e13760.
    PMID: 33842136 DOI: 10.7759/cureus.13760
    Melioidosis is an infectious disease most commonly found in places with tropical climates. Definitive diagnosis can be confirmed by culture or pathological results of blood or infected organ. However, imaging study is helpful in providing early provisional diagnosis and guiding therapy. Point-of-care ultrasound can be currently performed bedside by non-radiological staff such as emergency physicians or intensivists. We present the case of a pediatric patient who got diagnosed with melioidosis after detection of multiple splenic and hepatic abscesses by point-of-care ultrasound, leading to early diagnosis and appropriate empirical antibiotic selection, resulting in good treatment outcome.
    Matched MeSH terms: Point-of-Care Systems
  2. Arora H, Sharma A, Sharma S, Haron FF, Gafur A, Sayyed RZ, et al.
    Microorganisms, 2021 Apr 13;9(4).
    PMID: 33924471 DOI: 10.3390/microorganisms9040823
    Capsicum annuum L. is a significant horticulture crop known for its pungent varieties and used as a spice. The pungent character in the plant, known as capsaicinoid, has been discovered to have various health benefits. However, its production has been affected due to various exogenous stresses, including diseases caused by a soil-borne pathogen, Pythium spp. predominantly affecting the Capsicum plant in younger stages and causing damping-off, this pathogen can incite root rot in later plant growth stages. Due to the involvement of multiple Pythium spp. and their capability to disperse through various routes, their detection and diagnosis have become crucial. However, the quest for a point-of-care technology is still far from over. The use of an integrated approach with cultural and biological techniques for the management of Pythium spp. can be the best and most sustainable alternative to the traditionally used and hazardous chemical approach. The lack of race-specific resistance genes against Pythium spp. can be compensated with the candidate quantitative trait loci (QTL) genes in C. annuum L. This review will focus on the epidemiological factors playing a major role in disease spread, the currently available diagnostics in species identification, and the management strategies with a special emphasis on Pythium spp. causing damping-off and root rot in different cultivars of C. annuum L.
    Matched MeSH terms: Point-of-Care Systems
  3. Teng CL
    MyJurnal
    In the developing world, clinical knowledge management in primary care has a long way to go. Clinical decision support systems, despite its promise to revolutionise healthcare, is slow in its implementation due to the lack of financial investment in information technology. Point-of-care resources, such as comprehensive electronic textbooks delivered via the web or mobile devices, have yet to be fully utilised by the healthcare organisation or individual clinicians. Increasing amount of applicable knowledge of good quality (e.g. clinical practice guidelines and other pre-appraised resources) are now available via the internet. The policy makers and clinicians need to be more informed about the potential benefits and
    limitations of these new tools and resources and make the necessary budgetary provision and learn how best to harness them for patient care.
    Matched MeSH terms: Point-of-Care Systems
  4. Szakmany T, Fitzgerald E, Garlant HN, Whitehouse T, Molnar T, Shah S, et al.
    Front Immunol, 2023;14:1308530.
    PMID: 38332914 DOI: 10.3389/fimmu.2023.1308530
    INTRODUCTION: Early diagnosis of sepsis and discrimination from SIRS is crucial for clinicians to provide appropriate care, management and treatment to critically ill patients. We describe identification of mRNA biomarkers from peripheral blood leukocytes, able to identify severe, systemic inflammation (irrespective of origin) and differentiate Sepsis from SIRS, in adult patients within a multi-center clinical study.

    METHODS: Participants were recruited in Intensive Care Units (ICUs) from multiple UK hospitals, including fifty-nine patients with abdominal sepsis, eighty-four patients with pulmonary sepsis, forty-two SIRS patients with Out-of-Hospital Cardiac Arrest (OOHCA), sampled at four time points, in addition to thirty healthy control donors. Multiple clinical parameters were measured, including SOFA score, with many differences observed between SIRS and sepsis groups. Differential gene expression analyses were performed using microarray hybridization and data analyzed using a combination of parametric and non-parametric statistical tools.

    RESULTS: Nineteen high-performance, differentially expressed mRNA biomarkers were identified between control and combined SIRS/Sepsis groups (FC>20.0, p<0.05), termed 'indicators of inflammation' (I°I), including CD177, FAM20A and OLAH. Best-performing minimal signatures e.g. FAM20A/OLAH showed good accuracy for determination of severe, systemic inflammation (AUC>0.99). Twenty entities, termed 'SIRS or Sepsis' (S°S) biomarkers, were differentially expressed between sepsis and SIRS (FC>2·0, p-value<0.05).

    DISCUSSION: The best performing signature for discriminating sepsis from SIRS was CMTM5/CETP/PLA2G7/MIA/MPP3 (AUC=0.9758). The I°I and S°S signatures performed variably in other independent gene expression datasets, this may be due to technical variation in the study/assay platform.

    Matched MeSH terms: Point-of-Care Systems
  5. Peyman M, Tai LY, Khaw KW, Ng CM, Win MM, Subrayan V
    Int Ophthalmol, 2015 Oct;35(5):651-5.
    PMID: 25189684 DOI: 10.1007/s10792-014-9989-6
    To assess the intra-observer repeatability and inter-observer reproducibility of central corneal thickness (CCT) measurements of PachPen (Accutome, Inc., Pennsylvania, USA), a hand-held, portable ultrasonic pachymeter when used by an ophthalmic nurse compared to an ophthalmologist. Ophthalmology Clinic, University of Malaya Medical Center In this prospective study, CCT was measured in 184 eyes of 92 healthy subjects, first by a corneal surgeon experienced in ultrasound pachymetry (Observer 1) followed by an ophthalmic nurse new to the procedure (Observer 2). Nine measurements were obtained from each eye by each observer, independently. Measurements were compared between the observers. Coefficients of repeatability and reproducibility were calculated. The Bland-Altman plot was used to assess agreement between observers. Mean age of the study population was 54.3 ± 15.2 years old and consisted of 43.5% male. Mean CCT as measured by Observers 1 and 2 were 528.3 ± 32.9 and 530.7 ± 33.3 µm, respectively. Observer 1 showed higher repeatability of measurements compared to that of Observer 2 (coefficient of repeatability 3.46 vs. 5.55%). The measurements by both observers showed high correlation (0.96) and good agreement (mean difference -2.4 µm; 95% limits of agreement -21.4, 16.7 µm). Coefficient of reproducibility of measurements between observers was 5.08%. Accutome PachPen hand-held ultrasound pachymeters gives excellent intra-observer repeatability and inter-observer reproducibility by personnel of different training grades.
    Matched MeSH terms: Point-of-Care Systems*
  6. Foster D, Cox-Singh J, Mohamad DS, Krishna S, Chin PP, Singh B
    Malar J, 2014;13:60.
    PMID: 24548805 DOI: 10.1186/1475-2875-13-60
    Plasmodium knowlesi, a malaria parasite of Southeast Asian macaques, infects humans and can cause fatal malaria. It is difficult to diagnose by microscopy because of morphological similarity to Plasmodium malariae. Nested PCR assay is the most accurate method to distinguish P. knowlesi from other Plasmodium species but is not cost effective in resource-poor settings. Rapid diagnostic tests (RDTs) are recommended for settings where malaria is prevalent. In this study, the effectiveness of three RDTs in detecting P. knowlesi from fresh and frozen patient blood samples was evaluated.
    Matched MeSH terms: Point-of-Care Systems*
  7. Bustam A, Noor Azhar M, Singh Veriah R, Arumugam K, Loch A
    Emerg Med J, 2014 May;31(5):369-73.
    PMID: 23428721 DOI: 10.1136/emermed-2012-201789
    OBJECTIVES: The aim of this study was to evaluate if emergency medicine trainees with a short duration of training in echocardiography could perform and interpret bedside-focused echocardiography reliably on emergency department patients.
    METHODS: Following a web-based learning module and 3 h of proctored practical training, emergency medicine trainees were evaluated in technical and interpretative skills in estimating left ventricular function, detection of pericardial effusion and inferior vena cava (IVC) diameter measurements using bedside-focused echocardiography on emergency department patients. An inter-rater agreement analysis was performed between the trainees and a board-certified cardiologist.
    RESULTS: 100 focused echocardiography examinations were performed by nine emergency medicine trainees. Agreement between the trainees and the cardiologist was 93% (K=0.79, 95% CI 0.773 to 0.842) for visual estimation of left ventricular function, 92.9% (K=0.80, 95% CI 0.636 to 0.882) for quantitative left ventricular ejection fraction by M-mode measurements, 98% (K=0.74, 95% CI 0.396 to 1.000) for the detection of pericardial effusion, and 64.2% (K=0.45, 95% CI 0.383 to 0.467) for IVC diameter assessment. The Bland-Altman limits of agreement for left ventricular function was -9.5% to 13.7%, and a Pearson's correlation yielded a value of 0.82 (p<0.0001, 95% CI 0.734 to 0.881). The trainees detected pericardial effusion with a sensitivity of 60%, specificity of 100%, positive predictive value of 100% and negative predictive value of 97.9%.
    CONCLUSIONS: Emergency medicine trainees were found to be able to perform and interpret focused echocardiography reliably after a short duration of training.
    Study site: Trauma and emergency department, University of Malaya Medical Centre, Kuala Lumpur
    Matched MeSH terms: Point-of-Care Systems*
  8. Swathirajan CR, Vignesh R, Boobalan J, Solomon SS, Saravanan S, Balakrishnan P
    J Med Microbiol, 2017 Oct;66(10):1379-1382.
    PMID: 28901908 DOI: 10.1099/jmm.0.000514
    BACKGROUND: Sustainable suppression of HIV replication forms the basis of anti-retroviral therapy (ART) medication. Thus, reliable quantification of HIV viral load has become an essential factor to monitor the effectiveness of the ART. Longer turnaround-time (TAT), batch testing and technical skills are major drawbacks of standard real-time PCR assays.

    METHODS: The performance of the point-of-care Xpert HIV-1 viral load assay was evaluated against the Abbott RealTime PCR m2000rt system. A total of 96 plasma specimens ranging from 2.5 log10 copies ml-1 to 4.99 log10 copies ml-1 and proficiency testing panel specimens were used. Precision and accuracy were checked using the Pearson correlation co-efficient test and Bland-Altman analysis.

    RESULTS: Compared to the Abbott RealTime PCR, the Xpert HIV-1 viral load assay showed a good correlation (Pearson r=0.81; P<0.0001) with a mean difference of 0.27 log10 copies ml-1 (95 % CI, -0.41 to 0.96 log10 copies ml-1; sd, 0.35 log10 copies ml-1).

    CONCLUSION: Reliable and ease of testing individual specimens could make the Xpert HIV-1 viral load assay an efficient alternative method for ART monitoring in clinical management of HIV disease in resource-limited settings. The rapid test results (less than 2 h) could help in making an immediate clinical decision, which further strengthens patient care.

    Matched MeSH terms: Point-of-Care Systems*
  9. Kho SS, Chan SK, Yong MC, Cheah HM, Lee YG, Tie ST
    Respir Investig, 2020 Sep;58(5):367-375.
    PMID: 32107195 DOI: 10.1016/j.resinv.2020.01.004
    BACKGROUND: Tuberculous pleural effusions (TBEs) and parapneumonic pleural effusion (PPEs) have similar clinical presentations and fluid biochemistry. A pleural biopsy is usually required to diagnose TBE but complete fluid evacuation may not be necessary, contrasting with complicated PPE (CPPE). A point-of-care test that distinguishes between TBE and CPPE enables the appropriate procedures to be performed during the initial diagnostic thoracentesis. Lactate is a metabolic product measurable by a blood-gas analyzer. This study measured pleural fluid (Pf) lactate levels in TBE and compared them with those in PPE/CPPE. We hypothesized that Pf lactate would be significantly higher in PPE because of active metabolic activities than in TBE which is driven by delayed hypersensitivity.

    METHODS: All patients undergoing an initial diagnostic thoracentesis over 18 months with Pf lactate measured using a calibrated point-of-care blood gas analyzer were assessed.

    RESULTS: The diagnoses of the enrolled patients (n = 170) included TBE (n = 49), PPE (n = 47), malignancy (n = 63), and transudate (n = 11). Pf lactate level in TBE, median 3.70 (inter-quartile range 2.65-4.90) mmol/l, was significantly lower than in PPE and CPPE. In the subgroup of TBE and CPPE patients whose initial Pf pH and glucose could suggest either condition, Pf lactate was significantly higher in those with CPPE. Pf lactate (cutoff ≥7.25 mmol/l) had a sensitivity of 79.3%, specificity 100%, positive predictive value 100%, and negative predictive value 89.1% for discriminating CPPE from TBE (area under the curve 0.947, p Point-of-care Pf lactate measurements may have practical value in early separation of TBE or CPPE during initial thoracentesis, and warrants further investigation.

    Matched MeSH terms: Point-of-Care Systems*
  10. Boo NY, Chang YF, Leong YX, Tok ZY, Hooi LC, Chee SC, et al.
    Pediatr Res, 2019 08;86(2):216-220.
    PMID: 30696987 DOI: 10.1038/s41390-019-0304-0
    BACKGROUND: This study aimed to determine the accuracy of a point-of-care Bilistick method for measuring total serum bilirubin (TSB) and its turn-around-time (TAT) against hospital laboratory methods.

    METHODS: This prospective study was carried out on 561 term-gestation jaundiced neonates in two Malaysian hospitals. Venous blood sample was collected from each neonate for contemporary measurement of TSB by hospital laboratories and Bilistick. TAT was the time interval between specimen collection and TSB result reported by each method.

    RESULTS: The mean laboratory-measured TSB was 194.85 (±2.844) µmol/L and Bilistick TSB was 169.37 (±2.706) µmol/L. Pearson's correlation coefficient was: r = 0.901 (p 

    Matched MeSH terms: Point-of-Care Systems/standards*
  11. Horton S, Sullivan R, Flanigan J, Fleming KA, Kuti MA, Looi LM, et al.
    Lancet, 2018 05 12;391(10133):1953-1964.
    PMID: 29550030 DOI: 10.1016/S0140-6736(18)30460-4
    Modern, affordable pathology and laboratory medicine (PALM) systems are essential to achieve the 2030 Sustainable Development Goals for health in low-income and middle-income countries (LMICs). In this last in a Series of three papers about PALM in LMICs, we discuss the policy environment and emphasise three crucial high-level actions that are needed to deliver universal health coverage. First, nations need national strategic laboratory plans; second, these plans require adequate financing for implementation; and last, pathologists themselves need to take on leadership roles to advocate for the centrality of PALM to achieve the Sustainable Development Goals for health. The national strategic laboratory plan should deliver a tiered, networked laboratory system as a central element. Appropriate financing should be provided, at a level of at least 4% of health expenditure. Financing of new technologies such as molecular diagnostics is challenging for LMICs, even though many of these tests are cost-effective. Point-of-care testing can substantially reduce test-reporting time, but this benefit must be balanced with higher costs. Our research analysis highlights a considerable deficiency in advocacy for PALM; pathologists have been invisible in national and international health discourse and leadership. Embedding PALM in LMICs can only be achieved if pathologists advocate for these services, and undertake leadership roles, both nationally and internationally. We articulate eight key recommendations to address the current barriers identified in this Series and issue a call to action for all stakeholders to come together in a global alliance to ensure the effective provision of PALM services in resource-limited settings.
    Matched MeSH terms: Point-of-Care Systems/economics*
  12. Wan Mohd Zin RM, Ahmad Kamil ZI, Tuan Soh TR, Embong M, Wan Mohamud WN
    BMC Res Notes, 2013 Dec 18;6:540.
    PMID: 24344903 DOI: 10.1186/1756-0500-6-540
    BACKGROUND: Measurement of HbA1c has been widely used for long-term monitoring and management of diabetes control. There is increasing use of point-of-care (POC) devices for measuring HbA1c where quicker results would allow immediate clinical management decisions to be made. Therefore, it is important to evaluate and compare the performance of such devices to the reference laboratory method.

    FINDINGS: A total of 274 venous blood was collected from normal healthy adults during the community screening programmes. The performance of POC devices, Afinion and Quo-test were compared to central laboratory HPLC method; Adams A1c HA 8160. Both POC devices showed good correlation to HA 8160 with r = 0.94 (p < 0.001) and r = 0.95 (p < 0.001) for Afinion and Quo-test respectively. The means difference were statistically higher between POC and HA 8160 with 0.23% (95% CI 0.19-0.26, p < 0.001) and 0.29% (95% CI 0.24-0.34, p < 0.001) for Afinion and Quo-test respectively.

    CONCLUSIONS: Both POC devices could be considered in health clinics for diabetes management but not to be used for the diagnostic purposes.

    Matched MeSH terms: Point-of-Care Systems/standards*
  13. Choi JR, Liu Z, Hu J, Tang R, Gong Y, Feng S, et al.
    Anal Chem, 2016 06 21;88(12):6254-64.
    PMID: 27012657 DOI: 10.1021/acs.analchem.6b00195
    In nucleic acid testing (NAT), gold nanoparticle (AuNP)-based lateral flow assays (LFAs) have received significant attention due to their cost-effectiveness, rapidity, and the ability to produce a simple colorimetric readout. However, the poor sensitivity of AuNP-based LFAs limits its widespread applications. Even though various efforts have been made to improve the assay sensitivity, most methods are inappropriate for integration into LFA for sample-to-answer NAT at the point-of-care (POC), usually due to the complicated fabrication processes or incompatible chemicals used. To address this, we propose a novel strategy of integrating a simple fluidic control strategy into LFA. The strategy involves incorporating a piece of paper-based shunt and a polydimethylsiloxane (PDMS) barrier to the strip to achieve optimum fluidic delays for LFA signal enhancement, resulting in 10-fold signal enhancement over unmodified LFA. The phenomena of fluidic delay were also evaluated by mathematical simulation, through which we found the movement of fluid throughout the shunt and the tortuosity effects in the presence of PDMS barrier, which significantly affect the detection sensitivity. To demonstrate the potential of integrating this strategy into a LFA with sample-in-answer-out capability, we further applied this strategy into our prototype sample-to-answer LFA to sensitively detect the Hepatitis B virus (HBV) in clinical blood samples. The proposed strategy offers great potential for highly sensitive detection of various targets for wide application in the near future.
    Matched MeSH terms: Point-of-Care Systems*
  14. Warrener L, Slibinskas R, Chua KB, Nigatu W, Brown KE, Sasnauskas K, et al.
    Bull World Health Organ, 2011 Sep 01;89(9):675-82.
    PMID: 21897488 DOI: 10.2471/BLT.11.088427
    OBJECTIVE: To evaluate the performance of a newly developed point-of-care test (POCT) for the detection of measles-specific IgM antibodies in serum and oral fluid specimens and to assess if measles virus nucleic acid could be recovered from used POCT strips.

    METHODS: The POCT was used to test 170 serum specimens collected through measles surveillance or vaccination programmes in Ethiopia, Malaysia and the Russian Federation: 69 were positive for measles immunoglobulin M (IgM) antibodies, 74 were positive for rubella IgM antibodies and 7 were positive for both. Also tested were 282 oral fluid specimens from the measles, mumps and rubella (MMR) surveillance programme of the United Kingdom of Great Britain and Northern Ireland. The Microimmune measles IgM capture enzyme immunoassay was the gold standard for comparison. A panel of 24 oral fluids was used to investigate if measles virus haemagglutinin (H) and nucleocapsid (N) genes could be amplified by polymerase chain reaction directly from used POCT strips.

    FINDINGS: With serum POCT showed a sensitivity and specificity of 90.8% (69/76) and 93.6% (88/94), respectively; with oral fluids, sensitivity and specificity were 90.0% (63/70) and 96.2% (200/208), respectively. Both H and N genes were reliably detected in POCT strips and the N genes could be sequenced for genotyping. Measles virus genes could be recovered from POCT strips after storage for 5 weeks at 20-25 °C.

    CONCLUSION: The POCT has the sensitivity and specificity required of a field-based test for measles diagnosis. However, its role in global measles control programmes requires further evaluation.

    Matched MeSH terms: Point-of-Care Systems/standards*
  15. Grigg MJ, William T, Barber BE, Parameswaran U, Bird E, Piera K, et al.
    J Clin Microbiol, 2014 Jun;52(6):2053-60.
    PMID: 24696029 DOI: 10.1128/JCM.00181-14
    Plasmodium knowlesi causes severe and fatal malaria in Malaysia. Microscopic misdiagnosis is common and may delay appropriate treatment. P. knowlesi can cross-react with "species-specific" parasite lactate dehydrogenase (pLDH) monoclonal antibodies used in rapid diagnostic tests (RDTs) to detect P. falciparum and P. vivax. At one tertiary-care hospital and two district hospitals in Sabah, we prospectively evaluated two combination RDTs for malaria diagnosis by using both a pan-Plasmodium-pLDH (pan-pLDH)/P. falciparum-specific-pLDH (Pf-pLDH) RDT (OptiMAL-IT) and a non-P. falciparum VOM-pLDH/Pf-HRP2 RDT (CareStart). Differential cross-reactivity among these combinations was hypothesized to differentiate P. knowlesi from other Plasmodium monoinfections. Among 323 patients with PCR-confirmed P. knowlesi (n = 193), P. falciparum (n = 93), and P. vivax (n = 37) monoinfections, the VOM-pLDH individual component had the highest sensitivity for nonsevere (35%; 95% confidence interval [CI], 27 to 43%) and severe (92%; CI, 81 to 100%) P. knowlesi malaria. CareStart demonstrated a P. knowlesi sensitivity of 42% (CI, 34 to 49%) and specificity of 74% (CI, 65 to 82%), a P. vivax sensitivity of 83% (CI, 66 to 93%) and specificity of 71% (CI, 65 to 76%), and a P. falciparum sensitivity of 97% (CI, 90 to 99%) and specificity of 99% (CI, 97 to 100%). OptiMAL-IT demonstrated a P. knowlesi sensitivity of 32% (CI, 25 to 39%) and specificity of 21% (CI, 15 to 29%), a P. vivax sensitivity of 60% (CI, 42 to 75%) and specificity of 97% (CI, 94 to 99%), and a P. falciparum sensitivity of 82% (CI, 72 to 89%) and specificity of 39% (CI, 33 to 46%). The combination of CareStart plus OptiMAL-IT for P. knowlesi using predefined criteria gave a sensitivity of 25% (CI, 19 to 32%) and specificity of 97% (CI, 92 to 99%). Combining two RDT combinations was highly specific for P. knowlesi malaria diagnosis; however, sensitivity was poor. The specificity of pLDH RDTs was decreased for P. vivax and P. falciparum because of P. knowlesi cross-reactivity and cautions against their use alone in areas where P. knowlesi malaria is endemic. Sensitive P. knowlesi-specific RDTs and/or alternative molecular diagnostic tools are needed in areas where P. knowlesi malaria is endemic.
    Matched MeSH terms: Point-of-Care Systems*
  16. Ley B, Luter N, Espino FE, Devine A, Kalnoky M, Lubell Y, et al.
    Malar J, 2015 Sep 29;14:377.
    PMID: 26416229 DOI: 10.1186/s12936-015-0896-8
    The only currently available drug that effectively removes malaria hypnozoites from the human host is primaquine. The use of 8-aminoquinolines is hampered by haemolytic side effects in glucose-6-phosphate dehydrogenase (G6PD) deficient individuals. Recently a number of qualitative and a quantitative rapid diagnostic test (RDT) format have been developed that provide an alternative to the current standard G6PD activity assays. The WHO has recently recommended routine testing of G6PD status prior to primaquine radical cure whenever possible. A workshop was held in the Philippines in early 2015 to discuss key challenges and knowledge gaps that hinder the introduction of routine G6PD testing. Two point-of-care (PoC) test formats for the measurement of G6PD activity are currently available: qualitative tests comparable to malaria RDT as well as biosensors that provide a quantitative reading. Qualitative G6PD PoC tests provide a binomial test result, are easy to use and some products are comparable in price to the widely used fluorescent spot test. Qualitative test results can accurately classify hemizygous males, heterozygous females, but may misclassify females with intermediate G6PD activity. Biosensors provide a more complex quantitative readout and are better suited to identify heterozygous females. While associated with higher costs per sample tested biosensors have the potential for broader use in other scenarios where knowledge of G6PD activity is relevant as well. The introduction of routine G6PD testing is associated with additional costs on top of routine treatment that will vary by setting and will need to be assessed prior to test introduction. Reliable G6PD PoC tests have the potential to play an essential role in future malaria elimination programmes, however require an improved understanding on how to best integrate routine G6PD testing into different health settings.
    Matched MeSH terms: Point-of-Care Systems
  17. Ismail NF, Lim TS
    Sci Rep, 2016 Jan 19;6:19338.
    PMID: 26782912 DOI: 10.1038/srep19338
    Antibody labelling to reporter molecules is gaining popularity due to its many potential applications for diagnostics and therapeutics. However, non-directional bioconjugation methods which are commonly used often results in the loss of target binding capabilities. Therefore, a site-specific enzymatic based bioconjugation such as sortase-mediated transpeptidation allows for a more rapid and efficient method of antibody conjugation for diagnostic applications. Here we describe the utilization of sortase A bioconjugation to conjugate a single chain fragment variable (scFv) to the extracellular invertase (invB) from Zymomonas mobilis with the aim of developing an invertase based immunoassay. In addition, conjugation to enhanced green fluorescent protein (eGFP) was also validated to show the flexibility of the method. The invertase conjugated complex was successfully applied for the detection of antibody-antigen interaction using a personal glucose meter (PGM) for assay readout. The setup was used in both a direct and competitive assay highlighting the robustness of the conjugate for assay development. The method provides an alternative conjugation process to allow easy exchange of antibodies to facilitate rapid development of diagnostic assays for various diseases on the PGM platform.
    Matched MeSH terms: Point-of-Care Systems
  18. Sithambaram S, Hilmi I, Goh KL
    PLoS One, 2015;10(7):e0131616.
    PMID: 26158845 DOI: 10.1371/journal.pone.0131616
    M2 pyruvate kinase (M2PK) is an oncoprotein secreted by colorectal cancers in stools. This the first report on the accuracy of a rapid stool test in the detection of colorectal cancer (CRC).
    Matched MeSH terms: Point-of-Care Systems
  19. Nanthasurasak P, See HH, Zhang M, Guijt RM, Breadmore MC
    Angew Chem Int Ed Engl, 2019 03 18;58(12):3790-3794.
    PMID: 30614157 DOI: 10.1002/anie.201812077
    An electrokinetic platform was developed for extracting small-molecule pharmaceuticals from a dried blood spot. Through the exclusion of liquid reagents and use of low field strength (6 V cm-1 ), the electroextraction of a drug from a dried blood spot, deposited on a polymer inclusion membrane (PIM), could be realised while in transit in the mail. In transit sample preparation provides a potential solution to in situ sample degradation and may accelerate the workflow upon arrival of a patient sample at the analytical facility. The electroextraction method was enabled through our discovery of the use of 15-20 μm thin PIMs as electrophoretic separation medium in absence of liquid reagents. Here, a PIM consisting of cellulose triacetate as polymer base, 2-nitrophenyl octyl ether as plasticizer and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide as carrier was used. The PIM, was packaged with two 12 V batteries to supply the separation voltage. A blood spot containing berberine chloride was deposited and dried before the applying the separation potential, allowing for the electroextraction while the packaged device was shipped in internal mail. Upon arrival in the analytical laboratory, the PIM was analysed using a fluorescence microscope with photon multiplier tube, quantifying the berberine extracted away from the sample matrix. This platform represents a new opportunity for processing clinical samples during transport to the laboratory, saving time and manual handling to accelerate the time to result.
    Matched MeSH terms: Point-of-Care Systems
  20. Adi O, Fong CP, Azil A, Wahab SFA
    Ultrasound J, 2019 Feb 25;11(1):1.
    PMID: 31359296 DOI: 10.1186/s13089-019-0116-9
    BACKGROUND: We report a case study of fat embolism seen on ultrasound at right internal jugular vein during central venous cannulation in a patient diagnosed with fat embolism syndrome. This case demonstrates the importance of ultrasound for evaluation of trauma cases with suspicion of fat embolism.

    CASE PRESENTATION: A 23-year-old trauma patient with closed fracture of left femoral shaft and left humerus presented to our emergency department (ED). 11 h after admission to ED, patient became confused, hypoxic and hypotensive. He was then intubated for respiratory failure and mechanically ventilated. Transesophageal ultrasound revealed hyperdynamic heart, dilated right ventricle with no regional wall abnormalities and no major aorta injuries. Whole-body computed tomography was normal. During central venous cannulation of right internal jugular vein (IJV), we found free floating mobile hyperechoic spots, located at the anterior part of the vein. A diagnosis of fat embolism syndrome later was made based on the clinical presentation of long bone fractures and fat globulin in the blood. Despite aggressive fluid resuscitation, patient was a non-responder and needed vasopressor infusion for persistent shock. Blood aspirated during cannulation from the IJV revealed a fat globule. Patient underwent uneventful orthopedic procedures and was discharged well on day 5 of admission.

    CONCLUSIONS: Point-of-care ultrasound findings of fat embolism in central vein can facilitate and increase the suspicion of fat embolism syndrome.

    Matched MeSH terms: Point-of-Care Systems
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links