Displaying publications 601 - 620 of 1501 in total

Abstract:
Sort:
  1. Cheng KP, Wong WJ, Hashim S, Mun KS
    J Thorac Dis, 2017 Sep;9(9):E752-E756.
    PMID: 29221336 DOI: 10.21037/jtd.2017.08.74
    Hemangiopericytomas (HPCs) are uncommon tumours. We present the case of a 41-year-old female with multiple resections at different sites over the course of 11 years. The approach considerations, as well as treatment options and prognosis are discussed. A 41-year-old female with two previous resections for intracranial meningeal HPC in 2004 and 2008, as well as adjuvant radiotherapy, presented in 2015 with left intrathoracic and left hip recurrence confirmed by positron emission tomography/computed tomography (PET/CT). She underwent left proximal femur resection/reconstruction and video-assisted thoracoscopic surgery (VATS) resection of the intrathoracic tumour was attempted. She was discharged home on her 4th post-operative day with minimal pain. There were no neurosensory or motor deficits. Any patient who has been diagnosed with HPC in the past who develops new symptoms should be worked up for recurrence, regardless of the length of disease-free interval, as our case study suggested. There has yet to be a standardized follow-up regime due to the rarity of these tumours. HPC remains a rare soft tissue sarcoma with high recurrence rate. Planned VATS evaluation and resection is possible provided complete resection with clear surgical margins can be achieved, as clear surgical margins offer the best chance of survival.
    Matched MeSH terms: Positron Emission Tomography Computed Tomography
  2. Abidin ZAZ, Hayati F, Tan GH, Goh EH, Hafidzul J, Zulkifli MZ
    J Coll Physicians Surg Pak, 2018 Mar;28(3):S69-S70.
    PMID: 29482714 DOI: 10.29271/jcpsp.2018.03.S69
    A 46-year gentleman presented with a left-sided lumbar region pain without fever or dysuria. He denied episodes of acute urinary retention. There was a hard mass at the distal urethra with normal laboratory blood tests. Computed tomography urogram revealed a concurrent left renal staghorn calculus and large distal urethral stone. The urethral stone was fragmented via endourologic technique successfully. We report a case of a non-obstructing large urethral calculus in a gentleman with concurrent left renal staghorn calculus and discuss the literature review.
    Matched MeSH terms: Tomography, X-Ray Computed*
  3. Diong TW, Haflah NHM, Kassim AYM, Habshi SMIA, Shukur MH
    J Hand Surg Asian Pac Vol, 2018 Mar;23(1):26-32.
    PMID: 29409409 DOI: 10.1142/S2424835518500030
    BACKGROUND: The use of volar locking plate in distal radius fracture can lead to extensor tendon rupture due to dorsal screw penetration. The aim of our study was to investigate the occurrence of dorsal and intra-articular screw penetration using CT scan after volar distal radius osteosynthesis for distal radius fractures.

    METHODS: Thirty patients who underwent distal volar locking plate for distal radius fracture were included in a retrospective study. In all 30 patients no dorsal and intra-articular screw penetration were detected on standard AP and lateral views of a plain radiograph. CT scan of the operated wrist was performed to determine the number of intra-articular and dorsal screw penetrations. Clinical examination was performed to determine the wrist functions in comparison to the normal wrist.

    RESULTS: Nineteen wrists were noted to have screw penetration either dorsally or intraarticularly. The highest incidence is in the 2nd extensor compartment where 13 screws had penetrated with a mean of 2.46 mm. Six screws penetrated into the distal radial ulnar joint and five screws into the wrist joint with a mean of 2.83 mm and 2.6 mm, respectively. However, there was no incidence of tendon irritation or rupture.

    CONCLUSIONS: This study demonstrated a high incidence of dorsal and intra-articular screw penetration detected by CT scan which was not apparent in plain radiograph. We recommend that surgeons adhere to the principle of only near cortex fixation and downsizing the locking screw length by 2 mm.

    Matched MeSH terms: Tomography, X-Ray Computed*
  4. Baradaran H, Ng CR, Gupta A, Noor NM, Al-Dasuqi KW, Mtui EE, et al.
    Int Angiol, 2017 Oct;36(5):445-461.
    PMID: 28541017 DOI: 10.23736/S0392-9590.17.03811-1
    BACKGROUND: The extent of calcium volume in the carotid arteries of contrast-based computer tomography (CT) is a valuable indicator of stroke risk. This study presents an automated, simple and fast calcium volume computation system. Since the high contrast agent can sometimes obscure the presence of calcium in the CT slices, it is therefore necessary to identify these slices before the corrected volume can be estimated.

    METHODS: The system typically consists of segmenting the calcium region from the CT scan into slices based on Hounsfield Unit-based threshold, and subsequently computing the summation of the calcium areas in each slice. However, when the carotid volume has intermittently higher concentration of contrast agent, a dependable approach is adapted to correct the calcium region using the neighboring slices, thereby estimating the correct volume. Furthermore, mitigation is provided following the regulatory constraints by changing the system to semi-automated criteria as a fall back solution. We evaluate the automated and semi-automated techniques using completely manual calcium volumes computed based on the manual tracings by the neuroradiologist.

    RESULTS: A total of 64 patients with calcified plaque in the internal carotid artery were analyzed. Using the above algorithm, our automated and semi-automated system yields correlation coefficients (CC) of 0.89 and 0.96 against first manual readings and 0.90 and 0.96 against second manual readings, respectively. Using the t-test, there was no significant difference between the automated and semi-automated methods against manual. The intra-observer reliability was excellent with CC 0.98.

    CONCLUSIONS: Compared to automated method, the semi-automated method for calcium volume is acceptable and closer to manual strategy for calcium volume. Further work evaluating and confirming the performance of our semi-automated protocol is now warranted.

    Matched MeSH terms: Computed Tomography Angiography*
  5. Zain E, Zakian CM, Chew HP
    J Dent, 2018 04;71:31-37.
    PMID: 29378225 DOI: 10.1016/j.jdent.2018.01.009
    OBJECTIVE: The main objective of this study was to evaluate the accuracy of optical coherence tomography (OCT) in detecting naturally occurring non-cavitated fissure caries (NCFC) in totality and at different loci by visually assessing cross-sectional OCT scans (B-scan) with an interpretation criterion. The secondary objective was to evaluate the agreement between dimensions of NCFC measured with OCT and polarized light microscopy (PLM).

    METHODS: 71 investigation sites of sound fissure and naturally occurring NCFC on human extracted premolars were identified and scanned with a swept-source OCT. The teeth were then sectioned bucco-lingually at the investigation sites and imaged using PLM. Two calibrated examiners trained on the B-scan NCFC visual interpretation criteria established for this study, assessed the investigation sites and results were validated against PLM.

    RESULTS: Detection sensitivity of B-scan for NCFC when fissures were assessed in totality, or on the slopes or walls separately are 0.98, 0.95, 0.94 and specificity are 0.95, 0.90, and 0.95. One-way ANOVA showed that width measurements of wall loci done with OCT and PLM were not statistically different. However, OCT height measurements of slope loci were statistically bigger with a constant bias of 0.08 mm (of which is not clinically significant) and OCT height measurements of wall loci were statistically smaller (0.57 mm) and Bland-Altman plots indicated presence of proportionate bias.

    CONCLUSION: Visual assessment of B-scans with the interpretation criteria resulted in both high specificity and sensitivity and were not affected by loci location. OCT width measurement of wall loci is in agreement with PLM.

    CLINICAL SIGNIFICANCE: Unanimous high sensitivity in this and previous studies indicate that visual assessment of B-scans reliably rule out NCFC. Detection accuracy was not affected by loci location. Width of wall loci and/or height of slope loci in OCT B-scan are to be used for monitoring NCFC but not height of wall loci.

    Matched MeSH terms: Tomography, Optical Coherence/methods*
  6. Yong YL, Tan LK, McLaughlin RA, Chee KH, Liew YM
    J Biomed Opt, 2017 12;22(12):1-9.
    PMID: 29274144 DOI: 10.1117/1.JBO.22.12.126005
    Intravascular optical coherence tomography (OCT) is an optical imaging modality commonly used in the assessment of coronary artery diseases during percutaneous coronary intervention. Manual segmentation to assess luminal stenosis from OCT pullback scans is challenging and time consuming. We propose a linear-regression convolutional neural network to automatically perform vessel lumen segmentation, parameterized in terms of radial distances from the catheter centroid in polar space. Benchmarked against gold-standard manual segmentation, our proposed algorithm achieves average locational accuracy of the vessel wall of 22 microns, and 0.985 and 0.970 in Dice coefficient and Jaccard similarity index, respectively. The average absolute error of luminal area estimation is 1.38%. The processing rate is 40.6 ms per image, suggesting the potential to be incorporated into a clinical workflow and to provide quantitative assessment of vessel lumen in an intraoperative time frame.
    Matched MeSH terms: Tomography, Optical Coherence/methods*
  7. Yap E, Law ZK, Aslan Abdullah NM, Abdul Wahid SF
    EXCLI J, 2017;16:1233-1248.
    PMID: 29285019 DOI: 10.17179/excli2017-805
    Patients with advanced aggressive B-cell non-Hodgkin lymphomas (NHL) are usually treated with rituximab in combination with chemotherapy. However, disease relapse rates are high. Radiotherapy (RT) has been shown to be efficacious in treating early-stage NHL but its role in advanced stage diseases is unclear. We performed a systematic review of randomized controlled trials (RCTs) comparing chemotherapy with RT to chemotherapy alone in patients with newly diagnosed advanced aggressive NHL. We searched online databases and pooled similar outcome estimates. For time-to-event outcomes, we estimated hazard ratios (HR) for overall survival (OS) and event-free survival (EFS) using the fixed-effect model. Two RCTs involving 254 patients met inclusion criteria. The trials were single-centre RCTs with follow-up period of five and ten years. Both trials were conducted in the pre-rituximab era. Patients treated with consolidation RT had better OS (HR for mortality 0.61; 95 % CI 0.38 to 0.97) and EFS (HR for mortality 0.67; 95 % CI 0.46 to 0.98) compared to those who received no RT. There was an apparent benefit of RT on local control (OR 0.09; 95 % CI 0.04 to 0.20); although this was estimated as a dichotomous rather than time-to-event outcome. Limited evidence shows benefits of consolidation RT in advanced aggressive NHL. However, we were not able to estimate the effect size with confidence due to small number of trials and sample size. We cannot recommend routine consolidation RT in advanced aggressive NHL. More RCTs with the inclusion of rituximab and PET-CT monitoring are needed.
    Matched MeSH terms: Positron Emission Tomography Computed Tomography
  8. Acharya UR, Hagiwara Y, Sudarshan VK, Chan WY, Ng KH
    J Zhejiang Univ Sci B, 2018 1 9;19(1):6-24.
    PMID: 29308604 DOI: 10.1631/jzus.B1700260
    Radiology (imaging) and imaging-guided interventions, which provide multi-parametric morphologic and functional information, are playing an increasingly significant role in precision medicine. Radiologists are trained to understand the imaging phenotypes, transcribe those observations (phenotypes) to correlate with underlying diseases and to characterize the images. However, in order to understand and characterize the molecular phenotype (to obtain genomic information) of solid heterogeneous tumours, the advanced sequencing of those tissues using biopsy is required. Thus, radiologists image the tissues from various views and angles in order to have the complete image phenotypes, thereby acquiring a huge amount of data. Deriving meaningful details from all these radiological data becomes challenging and raises the big data issues. Therefore, interest in the application of radiomics has been growing in recent years as it has the potential to provide significant interpretive and predictive information for decision support. Radiomics is a combination of conventional computer-aided diagnosis, deep learning methods, and human skills, and thus can be used for quantitative characterization of tumour phenotypes. This paper discusses the overview of radiomics workflow, the results of various radiomics-based studies conducted using various radiological images such as computed tomography (CT), magnetic resonance imaging (MRI), and positron-emission tomography (PET), the challenges we are facing, and the potential contribution of radiomics towards precision medicine.
    Matched MeSH terms: Tomography, X-Ray Computed; Positron-Emission Tomography
  9. Wong SK, Patil PG
    J Prosthet Dent, 2018 Aug;120(2):210-213.
    PMID: 29551376 DOI: 10.1016/j.prosdent.2017.10.019
    STATEMENT OF PROBLEM: The inferior alveolar nerve (IAN) frequently loops backward before exiting from the mental foramen and spreads several millimeters medially to the foramen. Implant placement in this area may damage the nerve if the anterior loop area is not carefully identified in a radiographic or computed tomography (CT) evaluation.

    PURPOSE: The purpose of this observational study was to measure the prevalence of the presence of the anterior loop and to estimate sex and ethnicity-related variations in anterior loop length in the Malaysian population.

    MATERIAL AND METHODS: A total of 100 cone beam computed tomography (CBCT) Digital Imaging and Communications in Medicine (DICOM) files were selected from a pool of 810 ongoing or completed patients in 3 different ethnic groups: Malay (33), Indian (33), and Chinese (34). The DICOM data were imported into commercial software. The IAN was traced with software along with the anterior loop and part of the incisive nerve. The vertical length of the nerve was estimated from the canal to the opening of the mental foramen from the cross-sectional view and translated to the panoramic view. Measurement was made from this point to the most anterior point of the anterior loop by following the trajectory of the nerve and was repeated on the opposite side. A 2-way mixed analysis of variance (ANOVA) test was carried out to evaluate the sex- and ethnicity-related variations (α=.05).

    RESULTS: The anterior loop was present in 94% of the 100 participants. Overall anterior loop length (AnLL) ranged between 0.73 and 7.99 mm with a mean length of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side. Among all participants, no statistically significant differences were found between the left and right sides of the mandible (P=.379). Overall, no significant main effect of ethnicity (P=.869) or sex (P=.576) was found on AnLL measurements. Also, with multiple comparisons, no significant effect was found between each pair of ethnic groups. Men in all 3 ethnic groups had greater AnLL than women.

    CONCLUSIONS: The anterior loop was present in 94% of the 100 participants among the 3 major ethnic groups of Malaysia. Overall AnLL ranged between 0.73 and 7.99 mm and mean lengths of 3.69 ±1.75 mm on the left side and 3.85 ±1.73 mm on the right side, with no significant ethnicity- or sex-related variations.

    Matched MeSH terms: Cone-Beam Computed Tomography/methods
  10. Tan VP, Macdonald HM, Gabel L, McKay HA
    Arch Osteoporos, 2018 Mar 20;13(1):31.
    PMID: 29556801 DOI: 10.1007/s11657-018-0441-9
    Physical activity is essential for optimal bone strength accrual, but we know little about interactions between physical activity, sedentary time, and bone outcomes in older adolescents. Physical activity (by accelerometer and self-report) positively predicted bone strength and the distal and midshaft tibia in 15-year-old boys and girls. Lean body mass mediated the relationship between physical activity and bone strength in adolescents.

    PURPOSE: To examine the influence of physical activity (PA) and sedentary time on bone strength, structure, and density in older adolescents.

    METHODS: We used peripheral quantitative computed tomography to estimate bone strength at the distal tibia (8% site; bone strength index, BSI) and tibial midshaft (50% site; polar strength strain index, SSIp) in adolescent boys (n = 86; 15.3 ± 0.4 years) and girls (n = 106; 15.3 ± 0.4 years). Using accelerometers (GT1M, Actigraph), we measured moderate-to-vigorous PA (MVPAAccel), vigorous PA (VPAAccel), and sedentary time in addition to self-reported MVPA (MVPAPAQ-A) and impact PA (ImpactPAPAQ-A). We examined relations between PA and sedentary time and bone outcomes, adjusting for ethnicity, maturity, tibial length, and total body lean mass.

    RESULTS: At the distal tibia, MVPAAccel and VPAAccel positively predicted BSI (explained 6-7% of the variance, p 

    Matched MeSH terms: Tomography, X-Ray Computed/methods
  11. Borhanuddin BK, Abdul Latiff H, Mohamed Yusof AK
    Cardiol Young, 2022 Dec;32(12):1994-1998.
    PMID: 35707919 DOI: 10.1017/S1047951122000154
    BACKGROUND: CT is an accepted non-invasive imaging tool to assess the coronary arteries in adults; however, its utilisation in children is limited by high heart rate and lack of standardised protocol. We sought to assess diagnostic quality and factors that affect image quality of CT in assessing coronary artery lesions in Kawasaki patients less than 18 years of age.

    METHODOLOGY: CT coronary angiography was performed on patients with Kawasaki disease diagnosed with coronary aneurysm or suspected to have coronary stenosis. Studies were performed using electrocardiogram-gated protocols. General anaesthesia was used in patients who were not cooperative for breathing control. Heart rate, image quality, and effective radiation dose were documented.

    RESULTS: Fifty-two Kawasaki patients underwent CT coronary angiography to assess coronary artery lesions. Median heart rate was 88 beats per minute (range 50-165 beats/minute). Image quality was graded as excellent in 34 (65%) patients, good in 17 (32%), satisfactory in 1, and poor in 1 patient. Coronary artery aneurysm was found in 25 (bilateral = 6, unilateral = 19, multiple = 11). Thrombus was found in 11 patients resulting in partial and total occlusion in 8 and 3 patients, respectively. Coronary stenosis was noted in 2 patients. The effective radiation dose was 1.296 millisievert (median 0.81 millisievert). Better diagnostic imaging quality was significantly related to lower heart rate (p = 0.007).

    CONCLUSION: Electrocardiogram-triggered CT coronary angiography provides a good diagnostic assessment of coronary artery lesions in children with Kawasaki disease.

    Matched MeSH terms: Computed Tomography Angiography/methods
  12. Abdullah AH, Todo M, Nakashima Y
    Med Eng Phys, 2017 06;44:8-15.
    PMID: 28373012 DOI: 10.1016/j.medengphy.2017.03.006
    Femoral bone fracture is one of the main causes for the failure of hip arthroplasties (HA). Being subjected to abrupt and high impact forces in daily activities may lead to complex loading configuration such as bending and sideway falls. The objective of this study is to predict the risk of femoral bone fractures in total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA). A computed tomography (CT) based on finite element analysis was conducted to demonstrate damage formation in a three dimensional model of HAs. The inhomogeneous model of femoral bone was constructed from a 79 year old female patient with hip osteoarthritis complication. Two different femoral components were modeled with titanium alloy and cobalt chromium and inserted into the femoral bones to present THA and RHA models respectively. The analysis included six configurations, which exhibited various loading and boundary conditions, including axial compression, torsion, lateral bending, stance and two types of falling configurations. The applied hip loadings were normalized to body weight (BW) and accumulated from 1 BW to 3 BW. Predictions of damage formation in the femoral models were discussed as the resulting tensile failure as well as the compressive yielding and failure elements. The results indicate that loading directions can forecast the pattern and location of fractures at varying magnitudes of loading. Lateral bending configuration experienced the highest damage formation in both THA and RHA models. Femoral neck and trochanteric regions were in a common location in the RHA model in most configurations, while the predicted fracture locations in THA differed as per the Vancouver classification.
    Matched MeSH terms: Tomography, X-Ray Computed*
  13. Johari MI, Ismail MN, Mohamad F, Yusof MA
    BMJ Case Rep, 2021 Jan 18;14(1).
    PMID: 33461997 DOI: 10.1136/bcr-2020-236420
    Primary cardiac valve tumours are rare. This is a case report of a 32-year-old non-smoker man with a history of stroke 1 year prior and no other cardiovascular risk factors. The patient was admitted to our acute stroke ward for recurrent left hemiparesis, slurring of speech, facial asymmetry and central retinal artery occlusion. Initial laboratory investigations and ECG were normal. An urgent CT brain showed a large hypodense area at the right frontal, parietal, temporal, occipital region with effaced sulci and right lateral ventricle with midline shift and cerebral oedema in keeping with acute infarction. We proceeded with CT angiography of the cerebral and carotid on the following day, which revealed no evidence of thrombosis, aneurysm or arteriovenous malformation. There were no abnormal beaded vessels to suggest vasculitis. Transthoracic echocardiography revealed a large mobile mass in the left atrium. Meanwhile, MRI cardiac confirmed a large ill-defined mobile solid mass attached to the mitral valve's inferoseptal component suggestive of mitral valve myxoma. This case report highlights the significance of considering a cardiogenic source of emboli in patients with large cerebral infarcts and other cardiac embolic phenomena. Imaging modalities such as echocardiography and cardiac MRI will help detect treatable conditions, such as valvular myxoma and prevent further complications.
    Matched MeSH terms: Tomography, X-Ray Computed*
  14. Law HL, Wong SL, Tan S
    Singapore Med J, 2013 Feb;54(2):e28-30.
    PMID: 23462838
    Fat embolism to the lungs and brain is an uncommon complication following fractures. Few reports with descriptions of computed tomographic (CT) findings of emboli to the brain or cerebral fat embolism are available. We report a case of cerebral fat embolism following multiple skeletal fractures and present its CT findings here.
    Matched MeSH terms: Tomography, X-Ray Computed*
  15. Jamaluddin S, Sulaiman AR, Imran MK, Juhara H, Ezane MA, Nordin S
    Singapore Med J, 2011 Sep;52(9):681-4.
    PMID: 21947147
    The aim of this study was to determine the reliability and accuracy of the tape measurement method (TMM) with a nearest reading of 5 mm in assessing leg length discrepancy (LLD).
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  16. Ramli N, Rahmat K, Tan GP
    Singapore Med J, 2008 Jul;49(7):e175-7.
    PMID: 18695851
    Malignant osteopetrosis is associated with petrous carotid canal and internal carotid artery stenosis in the skull base. We present a four-year-old boy with malignant osteopetrosis who developed right frontal lobe infarction as a result of bilateral internal carotid artery hypotrophy.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  17. Mun-Wei L, Aiman-Mardhiyyah MY, Hayati AA, Ikram IM, Tai ELM, Shatriah I
    Korean J Ophthalmol, 2023 Feb;37(1):42-48.
    PMID: 36549302 DOI: 10.3341/kjo.2021.0131
    PURPOSE: Macular edema, serous retinal detachment, and retinal pigment epithelial detachment have been reported in patients with nephrotic syndrome. However, there is limited data about macular thickness in children with nephrotic syndrome. The aim of this study was to compare the mean macular thickness in children with nephrotic syndrome and in a control group and to correlate it with visual acuity and level of proteinuria.

    METHODS: The comparative cross-sectional study included 66 children aged 6 to 17 years with nephrotic syndrome and healthy control seen in two tertiary centers in Malaysia. We recorded demographic data, as well as visual acuity, level of proteinuria, and the mean macular thicknesses in both groups. The mean macular thickness was measured using Stratus optical coherence tomography according to nine areas of the Early Treatment Diabetic Retinopathy Study map.

    RESULTS: The mean foveal thickness was 238.15 ± 22.98 µm for children with nephrotic syndrome and 237.01 ± 22.60 µm for the control group. There was no significant difference in the mean macular thickness between the groups (p = 0.843). A significant correlation with visual acuity was observed in the superior outer macula (r = -0.41, p = 0.019), the nasal outer macula (r = -0.41, p = 0.019), and the inferior outer macula (r = -0.40, p = 0.021). There was no significant correlation between the mean macular thickness and level of proteinuria (p = 0.338), although those with higher levels of proteinuria demonstrated a trend towards increased macular thickness.

    CONCLUSIONS: The mean macular thickness in children with nephrotic syndrome was similar to that of healthy children. A significant correlation between the mean thickness of the outer macular layer and the presenting visual acuity was observed. There was no correlation between the mean macular thickness and the level of proteinuria.

    Matched MeSH terms: Tomography, Optical Coherence/methods
  18. Serena Low WC, Chuah JH, Tee CATH, Anis S, Shoaib MA, Faisal A, et al.
    Comput Math Methods Med, 2021;2021:5528144.
    PMID: 34194535 DOI: 10.1155/2021/5528144
    Pneumonia is an infamous life-threatening lung bacterial or viral infection. The latest viral infection endangering the lives of many people worldwide is the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which causes COVID-19. This paper is aimed at detecting and differentiating viral pneumonia and COVID-19 disease using digital X-ray images. The current practices include tedious conventional processes that solely rely on the radiologist or medical consultant's technical expertise that are limited, time-consuming, inefficient, and outdated. The implementation is easily prone to human errors of being misdiagnosed. The development of deep learning and technology improvement allows medical scientists and researchers to venture into various neural networks and algorithms to develop applications, tools, and instruments that can further support medical radiologists. This paper presents an overview of deep learning techniques made in the chest radiography on COVID-19 and pneumonia cases.
    Matched MeSH terms: Tomography, X-Ray Computed/statistics & numerical data
  19. Taha BA, Al Mashhadany Y, Hafiz Mokhtar MH, Dzulkefly Bin Zan MS, Arsad N
    Sensors (Basel), 2020 Nov 26;20(23).
    PMID: 33256085 DOI: 10.3390/s20236764
    Timely detection and diagnosis are essentially needed to guide outbreak measures and infection control. It is vital to improve healthcare quality in public places, markets, schools and airports and provide useful insights into the technological environment and help researchers acknowledge the choices and gaps available in this field. In this narrative review, the detection of coronavirus disease 2019 (COVID-19) technologies is summarized and discussed with a comparison between them from several aspects to arrive at an accurate decision on the feasibility of applying the best of these techniques in the biosensors that operate using laser detection technology. The collection of data in this analysis was done by using six reliable academic databases, namely, Science Direct, IEEE Xplore, Scopus, Web of Science, Google Scholar and PubMed. This review includes an analysis review of three highlights: evaluating the hazard of pandemic COVID-19 transmission styles and comparing them with Severe Acute Respiratory Syndrome (SARS) and Middle East Respiratory Syndrome (MERS) to identify the main causes of the virus spreading, a critical analysis to diagnose coronavirus disease 2019 (COVID-19) based on artificial intelligence using CT scans and CXR images and types of biosensors. Finally, we select the best methods that can potentially stop the propagation of the coronavirus pandemic.
    Matched MeSH terms: Tomography, X-Ray Computed/statistics & numerical data
  20. Cheng J, Wang H, Wei S, Mei J, Liu F, Zhang G
    Comput Biol Med, 2024 Mar;170:108000.
    PMID: 38232453 DOI: 10.1016/j.compbiomed.2024.108000
    Alzheimer's disease (AD) is a neurodegenerative disease characterized by various pathological changes. Utilizing multimodal data from Fluorodeoxyglucose positron emission tomography(FDG-PET) and Magnetic Resonance Imaging(MRI) of the brain can offer comprehensive information about the lesions from different perspectives and improve the accuracy of prediction. However, there are significant differences in the feature space of multimodal data. Commonly, the simple concatenation of multimodal features can cause the model to struggle in distinguishing and utilizing the complementary information between different modalities, thus affecting the accuracy of predictions. Therefore, we propose an AD prediction model based on de-correlation constraint and multi-modal feature interaction. This model consists of the following three parts: (1) The feature extractor employs residual connections and attention mechanisms to capture distinctive lesion features from FDG-PET and MRI data within their respective modalities. (2) The de-correlation constraint function enhances the model's capacity to extract complementary information from different modalities by reducing the feature similarity between them. (3) The mutual attention feature fusion module interacts with the features within and between modalities to enhance the modal-specific features and adaptively adjust the weights of these features based on information from other modalities. The experimental results on ADNI database demonstrate that the proposed model achieves a prediction accuracy of 86.79% for AD, MCI and NC, which is higher than the existing multi-modal AD prediction models.
    Matched MeSH terms: Positron-Emission Tomography/methods