Materials and Methods: One hundred and sixty endodontically treated maxillary central incisors embedded in acrylic resin with decoronated root portion were taken for the study. The postspaces were prepared according to standard protocol. The samples were divided into two groups according to the post material: glass-fiber post and Quartz fiber post. These groups were further subdivided on the basis of coronal extension of 4 and 6 mm for glass fiber and Quartz fiber posts, respectively. The posts were then luted with dual-polymerizing resin cement followed by core buildup. Samples were subjected to increasing compressive oblique load until fracture occurred in a universal testing machine. Data were analyzed with one-way ANOVA and independent Student's t-test. Analysis was done using SPSS version 15 (SPSS Inc., Chicago, IL, USA) Windows software program.
Results: Glass fiber post with coronal extension of 4 mm (182.8 N) showed better results than with 6-mm length (124.1 N). Similarly, in quartz fiber posts group, 4-mm postlength (314 N) was better when compared with 6 mm (160 N). The 4-mm coronal extension of quartz fiber post displayed superior fracture resistance.
Conclusions: Glass fiber posts showed better fracture resistance than Quartz fiber posts. 4-mm coronal length showed more fracture resistance than 6 mm.
METHODS: In this study that employed a comparative design, fifty-nine typically developing Malaysian children (24 boys, aged from 8 years, 0 months to 8 years, 11 months) were enrolled. They were chosen from three different classrooms (consisting of high achieving, medium achieving and low achieving students, respectively) in a primary school. Their ORF and SRF skills were assessed according to the established methods.
RESULTS: As revealed by two-way ANOVA results, both ORF and SRF scores were found to be comparable between boys and girls (p > 0.05). In contrast, ORF and SRF results between the three classrooms were significantly different from each other (p
METHODS: This was an observational manikin-based study. A total of 96 participants as well as two types of mechanical compression devices: Lucas-2 and AutoPulse, performed one minute of continuous chest compression on BT-CPEA programmed manikin while the ambulance travelled at different speeds, i.e., idle state, 30km/hr and 60km/hr. Seven outcome variables of chest compression were measured. Performance data of different groups of compressor were compared and analysed using repeated measures analysis of variance (ANOVA).
RESULTS: In manual chest compression, significant variation were noted among different speeds in term of average compression rate (p<0.001), average compression depth (p=0.007), fraction of adequate/insufficient compression depth and fraction of normal hands positioning with p=0.018, 0.022 and 0.034 respectively. Overall, AutoPulse and Lucas-2 were not affected by ambulance speed. Lucas- 2 showed more consistent average compression rate, higher fraction of adequate compression depth and reduced fraction of insufficient compression depth as compared to manual compression with p<0.001, 0.001 and 0.043 respectively.
CONCLUSION: In this study we found that ambulance speed significantly affected certain aspects of manual chest compression most notably compression depth, rate and hand positioning. AutoPulse and Lucas-2 can improve these aspects by providing more consistent compression rate, depth and fraction of adequate compression depth during transport.
Materials and Methods: In this in-vitro study, a total of 48 single-rooted permanent human teeth were decoronated, and the roots were treated endodontically. Following post space preparation, the sample was divided into four groups (n= 12 each) based on the types of post and cement. Two different types of post [GC everStick®POST (ES) and Parapost® Fiber LuxTM (PF)], and two different types of cement [G-CEMTM (G), and RelyXTM Unicem (R)] were used according to the manufacturer's instructions. All roots were sectioned at the coronal and middle thirds with a thickness of 3±0.1mm. The Push-out bond strength (PBS) test was performed using a universal testing machine at a cross-head speed of 0.5mm/ min. The bond strength values were recorded, and the data were analyzed using the SPSS program. Apart from descriptive statistics, three-way ANOVA was used for the interaction of the independent variables (post, cement, and root level). For differences between the groups, the Mann-Whitney U test was used. A P-value of less than 0.05 was considered significant for all analyses.
Results: Push-out bond strength of samples at the middle level (11.38±10.31 MPa), with PF posts (11.18±9.98 MPa), and of those luted with RelyXTM Unicem cement (13.26±8.73 MPa) was higher than that of their counterparts. The PBS means of RelyXTM Unicem cement at both root levels were much higher than PBS means of G-CEMTM cement. Three-way ANOVA test revealed a significant effect for each variable with a higher effect of cement (Sum of Squares= 1310.690; P< 0.001). No significant difference (P= 0.153) was found between the coronal and middle parts and between ES and PF posts (P= 0.058). However, a highly significant difference (P< 0.001) was found between RelyXTM Unicem and G-CEMTM cements.
Conclusion: The type of cement had a significant effect on push-out bond strength with RelyXTM Unicem which had higher values than G-CEMTM. However, the type of post and root level had no significant effect on PBS, although Parapost® Fiber LuxTM and middle root level had higher values than their counterparts.
Method: The study was performed as a cross sectional study conducted at two different centres in Malaysia. Ninety-eight patients who were diagnosed with rhinosinusitis and fulfilled the selection criteria were assessed as for the symptom score and VAS and the measurement of angulation of nasal septum was performed through a coronal view of CT paranasal sinuses in bone window setting at osteomeatal complex level.
Results: The result obtained from one-way ANOVA test revealed a significant association between category of severity of septal angulation and the symptom score of rhinosinusitis (p=0.025). In addition, the result obtained from one-way ANOVA test also revealed a significant association between category of severity of septal angulation and the VAS of rhinosinusitis (p<0.05).
Conclusion: Severity of nasal septum angulation may be significantly associated with severity of rhinosinusitis based on symptom score and VAS. These findings could be used in tailored management of patient with rhinosinusitis especially during functional endoscopic sinus surgery.
PARTICIPANTS: The study included 16 patients with UVFP who underwent either LR (9 patients) or thyroplasty (7 patients) between 2015 and 2018 who fulfilled the inclusion criteria.
MAIN OUTCOME MEASURES: The outcomes were measured subjectively and objectively with: (1) voice handicap index-10 (VHI-10- Malay version); (2) auditory perceptual evaluation using the breathiness component of Grade, Roughness, Breathiness, Asthenia, Strain scale; (3) maximum phonation time (MPT); and (4) acoustic analysis (jitter%, shimmer%, and NHR) using OperaVOXTM. The outcomes were measured at baseline, 6 and 12-months postoperative. The comparison of outcomes between pre and postoperative of each group was evaluated using one-way ANOVA test. Mann-Whitney test was used to compare the outcomes between the two groups.
RESULTS: Comparison of each group at different time points showed significant improvement of VHI-10 and MPT of LR group between baseline and 12 months (P ≤ 0.05) whereas, the improvement in thyroplasty group was observed at all time points (P ≤ 0.05). When comparing between the two groups at 12 months, the VHI-10 and MPT was significantly better in the LR group than thyroplasty group with P = 0.004 and P = 0.001 respectively. Other outcome measures did not reveal significant difference between the two groups.
CONCLUSION: This observational study showed that LR may be better than thyroplasty in improving VHI-10 and MPT in selected patients with UVFP.