Displaying publications 61 - 80 of 151 in total

Abstract:
Sort:
  1. Liew KB, Loh GO, Tan YT, Peh KK
    Biomed Chromatogr, 2015 Jun;29(6):953-60.
    PMID: 25400284 DOI: 10.1002/bmc.3378
    A simple, rapid, specific and reliable UFLC coupled with ESI-MSMS assay method to simultaneously quantify sildenafil and N-desmethyl sildenafil, with loperamide as internal standard, was developed. Chromatographic separation was performed on a Thermo Scientific Accucore C18 column with an isocratic mobile phase composed of 0.1% v/v formic acid in purified water-methanol (20:80, v/v), at a flow rate of 0.3 mL/min. Sildenafil, N-desmethyl sildenafil and loperamide were detected with proton adducts at m/z 475.4 > 58.2, 461.3 > 85.2 and 477.0 > 266.1 in multiple reaction monitoring positive mode, respectively. Both analytes and internal standard were extracted by diethyl ether. The method was validated over a linear concentration range of 10-800 ng/mL for sildenafil and 10-600 ng/mL for N-desmethyl sildenafil with correlation coefficient (r(2) ) ≥0.9976 for sildenafil and (r(2) ) ≥0.9992 for N-desmethyl sildenafil. The method was precise, accurate and stable. The proposed method was applied to study the bioequivalence between a 100 mg dose of two pharmaceutical products: Viagra (original) and Edyfil (generic) products. AUC0-t , Cmax and Tmax were 2285.79 ng h/mL, 726.10 ng/mL and 0.94 h for Viagra and 2363.25 ng h/mL, 713.91 ng/mL and 0.83 hour for Edyfil. The 90% confidence interval of these parameters of this study fall within the regulatory range of 80-125%, hence they are considered as bioequivalent.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  2. Liew KB, Peh KK, Fung Tan YT
    Pak J Pharm Sci, 2014 Sep;27(5):1303-7.
    PMID: 25176366
    The effect of deprotenizing agents on recovery of donepezil hydrochloride in the development of a simple, rapid, selective and sensitive high performance liquid chromatography method for quantification of donepezil hydrochloride in human plasma was described. The deprotenizing agents were comprised of, perchloric acid, methanol, acetonitrile, chloroform and their mixtures. The chromatographic separation was carried out using reversed phase C18 column (Agilent Eclipse Plus C18) with UV detection at 268 nm. The mobile phase was comprised of 0.01 M potassium dihydrogen phosphate buffer, methanol and acetronitrile (50:30:20, v/v) adjusted to pH 2.7 with phosphoric acid (80%). A combination of perchloric acid and methanol gave a cleaner sample with a good recovery of donepezil hydrochloride of above 96%. The method showed intraday precision and accuracy in the range of 6.82% to 1.5% and 3.13% to 1.12% respectively, while interday precision and accuracy ranged between 1.06% to 4.71% and 13.01% to 6.43% respectively. The standard calibration curve was linear from 30ng/mL to 4000ng/mL, with a correlation coefficient of 0.9965±0.0034. The retention time of donepezil was 5.9 min with a run time of 7.0 min. The method can be applied to analyze large batch plasma samples in pharmacokinetic studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  3. Liew KB, Loh GO, Tan YT, Peh KK
    Biomed Chromatogr, 2014 Dec;28(12):1782-8.
    PMID: 24788875 DOI: 10.1002/bmc.3221
    A simple, rapid, specific and reliable high-performance liquid chromatographic assay of meloxicam in human plasma has been developed using a C18 reversed-phase analytical column. Reversed-phase chromatography was conducted using a mobile phase of 0.02 potassium dihydrogen phosphate (adjusted to pH 2.7 with phosphoric acid)-acetonitrile-triethylamine (35:65:0.05, v/v) with UV detection at 354 nm. The drug in human plasma was deproteinized using a combination of methanol and chloroform. This method is simple, rapid and consistent with a high recovery of meloxicam in human plasma ranging from 93.29 to 111.09%. Regression analysis for the calibration plot for plasma standards obtained for the drug concentrations between (25-4000) ng/mL indicated excellent linearity (r ≥ 0.9997). The proposed method was applied to study the bioequivalence between Mobic (original) and Melocam (generic) products. The study was conducted on using two tablets (4 × 7.5 mg) of each of the commercial product and the reference standard in a two-way open randomized crossover design involving 20 volunteers. Area under the concentration-time curve, peak concentration (C(max)) and time to reach C(max) were 72,868.61 ng h/mL, 2133.93 ng/mL and 4.06 h for Mobic, and 78,352.52 ng h/mL, 2525.18 ng/mL and 3.61 h for Melocam. Two C(max) were discovered in the pharmacokinetic profiles which confirm enterohepatic recirculation.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  4. Ling SS, Yuen KH, Barker SA
    PMID: 12450550
    A high-performance liquid chromatographic method with ultraviolet (UV) detection was developed for measuring cefotaxime in rat and human plasma. The method used direct injection of the plasma supernatant after deproteinization with 70% perchloric acid. Degradation of cefotaxime in acidic medium was retarded by adding phosphate buffer before centrifuging the sample. The mobile phase was 0.05 M aqueous ammonium acetate-acetonitrile-tetrahydrofuran (87:11:2, v/v) adjusted to pH 5.5. Analysis was run at a flow-rate of 1.0 ml/min, and a detection wavelength of 254 nm was used. The method has a quantification limit of 0.20 microgram/ml. The within- and between-day coefficients of variation and accuracy values were less than 8% and +/-3%, respectively, while the recovery values were greater than 87% over the concentration range tested (0.20-50 microgram/ml). The speed, sensitivity, specificity and reproducibility of this method make it particularly suitable for the routine determination of cefotaxime in human plasma. Moreover, only a relatively small sample plasma volume (100 microliter) is required, allowing this method to be applied to samples taken from neonates.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  5. Lo SK, Baharin BS, Tan CP, Lai OM
    J Chromatogr Sci, 2004 Mar;42(3):145-54.
    PMID: 15023251
    Separation of 1,2(2,3)- and 1,3-positional isomers of diacylglycerols (DAG) from vegetable oils by reversed-phase high-performance liquid chromatography (RP-HPLC) is investigated. The method is based on isocratic elution using 100% acetonitrile and UV detection at 205 nm. The following elution order of DAG molecular species is identified: 1,3-dilinolein < 1,2-dilinolein < 1,3-dimyristin < 1-oleoyl-3-linoleoyl-glycerol < 1,2-dimyristoyl-rac-glycerol < 1(2)-oleoyl-2(3)-linoleoyl-glycerol < 1-linolenoyl-3-stearoyl-glycerol < 1(2)-linolenoyl-2(3)-stearoyl-glycerol < 1,3-diolein < 1-palmitoyl-3-oleoyl-glycerol < 1,2-dioleoyl-sn-glycerol < 1(2)-palmitoyl-2(3)-oleoyl-glycerol < 1-linoleoyl-3-stearoyl-glycerol < 1,3-dipalmitin < 1(2)-linoleoyl-2(3)-stearoyl-glycerol < 1-oleoyl-3-stearoyl-glycerol < 1,2-dipalmitoyl-rac-glycerol < 1-palmitoyl-3-stearoyl-sn-glycerol < 1,3-distearin < 1,2-distearoyl-rac-glycerol. Linearity is observed over three orders of magnitude. Limits of detection and quantitation range 0.2-0.7 microg/mL for 1,3-dilinolein to 0.6-1.9 microg/mL for 1,2-dioleoyl-sn-glycerol, respectively. Precision and accuracy of the method are also demonstrated. The method is developed to separate mixtures of DAG molecular species produced from edible oils.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  6. Loh GOK, Wong EYL, Tan YTF, Heng SC, Saaid M, Cheah KY, et al.
    Molecules, 2022 Sep 04;27(17).
    PMID: 36080473 DOI: 10.3390/molecules27175706
    Etoricoxib is a non-steroidal anti-inflammatory drug (NSAID) used to treat pain and inflammation. The objective of the current study was to develop a sensitive, fast and high-throughput HPLC-ESI-MS/MS method to measure etoricoxib levels in human plasma using a one-step methanol protein precipitation technique. A tandem mass spectrometer equipped with an electrospray ionization (ESI) source operated in a positive mode and multiple reaction monitoring (MRM) were used for data collection. The quantitative MRM transition ions were m/z 359.15 > 279.10 and m/z 363.10 > 282.10 for etoricoxib and IS. The linear range was from 10.00 to 4000.39 ng/mL and the validation parameters were within the acceptance limits of the European Medicine Agency (EMA) and Food and Drug Analysis (FDA) guidelines. The present method was sensitive (10.00 ng/mL with S/N > 40), simple, selective (K prime > 2), and fast (short run time of 2 min), with negligible matrix effect and consistent recovery, suitable for high throughput analysis. The method was used to quantitate etoricoxib plasma concentrations in a bioequivalence study of two 120 mg etoricoxib formulations. Incurred sample reanalysis results further supported that the method was robust and reproducible.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  7. Loh GOK, Wong EYL, Tan YTF, Lee YL, Pang LH, Chin MC, et al.
    PMID: 32905988 DOI: 10.1016/j.jchromb.2020.122337
    A simple, rapid, sensitive, and reproducible liquid chromatography-tandem mass spectrometry method was developed to determine sitagliptin in human plasma. Diphenhydramine HCl was used as internal standard (IS). The chromatographic separation was achieved using Agilent Poroshell 120 EC-C18 - Fast LC column (100 × 2.1mmID, 2.7) fitted with UHPLC Guard Poroshell 120 EC-C18 (5 × 2.1mmID, 2.7 µm). The mobile phase consisted of 0.1% v/v formic acid and methanol (45:55, v/v) run at a flow rate of 0.45 mL/min at 30 °C. Methanol produced relatively cleaner plasma sample as deproteinization agent. Polytetrafluoroethylene membrane was preferred over nylon membrane as the former produced clear plasma samples. The standard calibration curve was linear over the concentration range of 5-500.03 ng/mL. The within-run precision was 0.53-7.12% and accuracy 87.09-105.05%. The between-run precision was 4.74-11.68% and accuracy 95.02-97.36%. The extended run precision was 3.60-6.88% and accuracy 93.18-95.82%. The recovery of analyte and IS was consistent. Sitagliptin in plasma was stable at benchtop (short term) for 24 h, in autosampler tray for 48 h, in instrumentation room for 48 h (post-preparative), after 7 freeze-thaw cycles (-20 ± 10 °C), and 62 days in the freezer (-20 ± 10 °C). Both sitagliptin (analyte) and IS stock solutions were stable for 62 days when kept at room temperature (25 ± 4 °C) and in chiller (2-8 °C). The validated method was successfully applied to a bioequivalence study of two sitagliptin formulations involving 26 healthy Malaysian volunteers.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  8. Loh GOK, Wong EYL, Tan YTF, Ong LM, Ng RS, Wee HC, et al.
    PMID: 33429127 DOI: 10.1016/j.jchromb.2020.122517
    A simple, fast and sensitive LC-MS/MS method was developed to quantify terazosin in human plasma. The mobile phase consisted of acetonitrile-0.1% (v/v) formic acid (70:30, v/v). Prazosin was used as internal standard (IS). As deproteinization agent, acetonitrile produced a clean sample. A higher response intensity with more symmetrical peak was obtained using Agilent Poroshell 120 EC-C18 - Fast LC column (100 × 2.1mmID, 2.7 μm) compared with Kinetex XB-C18 (100 × 2.1 mm, 2.6 µm) column. The response of terazosin and IS were approximately two times in citrate phosphate dextrose (CPD) plasma compared with dipotassium ethylenediaminetetraacetic acid (K2EDTA) plasma. Plasma calibration curve was linear from 1.0 to 100.0 ng/mL, with coefficient of determination r2 ≥ 0.99. The within-run and between-run precision values (CV, %) were <5.2% and <7.8%, while accuracy values were 102.8-112.7% and 103.4-112.2%. The extended run accuracy was 98.6-102.8% and precision (CV, %) 4.3-10.4%. The recovery of analyte was >98% and IS >94%. Terazosin in plasma kept at benchtop was stable for 24 h, in autosampler tray for 48 h, in instrumentation room for 48 h, for 7 freeze-thaw cycles and in freezer for 140 days. Terazosin and IS stock standard solutions were stable for 140 days at room temperature and in the chiller. The high throughput method was successfully utilized to measure 935 samples in a bioequivalence study of terazosin.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  9. Loh GOK, Wong EYL, Goh CZ, Tan YTF, Lee YL, Pang LH, et al.
    Ann Med, 2023;55(2):2270502.
    PMID: 37857359 DOI: 10.1080/07853890.2023.2270502
    The study aimed to develop a sensitive and high-throughput liquid chromatography coupled with tandem mass spectrometry method to quantify concentrations of tramadol and paracetamol simultaneously in human plasma. Sample preparation involved single-step protein precipitation using methanol and two deuterated internal standards, tramadol D6 and paracetamol D4. Agilent Poroshell 120 EC-C18 (100 × 2.1 mm, 2.1 µm) analytical column was employed to achieve chromatographic separation. Detection was in positive ion multiple reaction monitoring mode. A tailing factor (Tf) of <1.2, separation factor (K prime) of >1.5 from the column dead time and signal-to-noise (S/N) ratio >10, were obtained for analytes and internal standards. The standard curve was linear over the concentration range of 2.5-500.00 ng/mL for tramadol and 0.025-20.00 μg/mL for paracetamol. A small injection volume of 1 µL, low flow rate of 440 µL/min and short analysis time of 3.5 min reduced the solvent consumption, analysis cost and system contamination. The results of method validation parameters fulfilled the acceptance criteria of bioanalytical guidelines. The method was successfully applied to a bioequivalence study of fixed-dose combination products of tramadol and paracetamol in Malaysian healthy subjects.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  10. Loon YH, Wong JW, Yap SP, Yuen KH
    PMID: 15664346
    A simple liquid chromatographic method was developed for the simultaneous determination of flavonoids from Orthosiphon stamineus Benth, namely sinensitin, eupatorin and 3'-hydroxy-5,6,7,4'-tetramethoxyflavone, in plasma. Prior to analysis, the flavonoids and the internal standard (naproxen) were extracted from plasma samples using a 1:1 mixture of ethyl acetate and chloroform. The detection and quantification limits for the three flavonoids were similar being 3 and 5 ng/ml, respectively. The within-day and between-day accuracy values, expressed as percentage of true values, for the three flavonoids were between 95 and 107%, while the corresponding precision, expressed as coefficients of variation, for the three flavonoids were less than 14%. In addition, the mean recovery values of the extraction procedure for all the flavonoids were between 92 and 114%. The calibration curves were linear over a concentration range of 5-4000 ng/ml. The present method was applied to analyse plasma samples obtained from a pilot study using rats in which the mean absolute oral bioavailability values for sinensitin, eupatorin and 3'-hydroxy-5,6,7,4'-tetramethoxyflavone was 9.4, 1.0 and 1.5%, respectively.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  11. Mahyudin NA, Blunt JW, Cole AL, Munro MH
    J Biomed Biotechnol, 2012;2012:894708.
    PMID: 22291452 DOI: 10.1155/2012/894708
    The application of an HPLC bioactivity profiling/microtiter plate technique in conjunction with microprobe NMR instrumentation and access to the AntiMarin database has led to the isolation of a new 1. In this example, 1 was isolated from a cytotoxic fraction of an extract obtained from marine-derived Streptomyces sp. cultured on Starch Casein Agar (SCA) medium. The 1D and 2D (1)H NMR and ESIMS data obtained from 20 μg of compound 1 fully defined the structure. The known 2 was also isolated and readily dereplicated using this approach.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  12. Malintan NT, Mohd MA
    J Chromatogr A, 2006 Sep 15;1127(1-2):154-60.
    PMID: 16806241
    An analytical HPLC method for the simultaneous determination of eight sulfonamides in swine wastewater was developed. The samples were collected from three states in Malaysia. Sample clean up was carried out by employing solid-phase extraction using a 60 mg Oasis HLB (Waters) cartridge with 3 ml reservoir. The HPLC column used was Supelcosil C18 (250 mm x 4.6mm I.D.) and elution was carried out using gradient mode. The mobile phases used were acetonitrile and 0.5% acetic acid in purified water. Antibiotics were detected using UV absorbance at 272 nm. Recoveries obtained for sulphanilamide ranged from 31.9+/-5.1% to 36.2+/-1.0%, while recoveries for other sulfa drugs studied were from 91.9+/-5.0% to 106.0+/-1.1%. The limit of quantitation (LOQ) for sulfamerazine, sulfamethazine and sulfamethoxypyridazine was 7.5 ng/L, while the LOQ for the other studied antibiotics was 5.0 ng/L. The method was used to analyse sulfonamides in wastewater collected from selected Malaysian swine facilities.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  13. Man F, Choo CY
    PMID: 28869873 DOI: 10.1016/j.jchromb.2017.08.037
    Bruceines D and E are quassinoids from seeds of Brucea javanica (L.) Merr. exhibiting hypoglycemia effect. The crude drug is used as a traditional medicine by diabetes patients. The aim of this study is to understand the bioavailability and pharmacokinetics of both the bruceines D & E. A rapid and sensitive HPLC-MS/MS method was developed and validated for the quantification of both quassinoids, bruceines D & E in rat plasma. Both the bruceines D & E were separated with the Zorbax SBC-18 column with gradient elution and mobile phase system of acetonitrile and deionized water with 0.1% formic acid at a flow rate of 0.5mL/min. Analytes were detected in multiple reaction monitoring (MRM) mode with electrospray positive ionization. The quassinoids, namely bruceines D & E were detected with transitions of m/z 411.2→393.2 and m/z 395.2→377.2, respectively. Another quassinoid, eurycomanone was used as the internal standard with transition of m/z 409.2→391.2. The method was validated and conformed to the regulatory requirements. The validated method was applied to pharmacokinetic and bioavailability studies in rats. The pharmacokinetic study indicated both bruceine D and E were rapidly absorbed into the circulation system and reached its peak concentration at 0.54±0.34h and 0.66±0.30h, respectively. Bruceine E was eliminated slower than Bruceine D with t1/2 value almost increased two-fold compared to Bruceine D. In conclusion, a rapid, selective and sensitive HPLC-MS/MS method was developed for the simultaneous determination of both the bruceines D and E in rat plasma. Both bruceines D and E displayed poor oral bioavailability.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  14. Mansor SM, Navaratnam V, Yahaya N, Nair NK, Wernsdorfer WH, Degen PH
    J Chromatogr B Biomed Appl, 1996 Jul 12;682(2):321-5.
    PMID: 8844426
    A rapid and selective high-performance liquid chromatographic assay for determination of a new antimalarial drug (benflumetol, BFL) is described. After extraction with hexane-diethyl ether (70:30, v/v) from plasma, BFL was analysed using a C18 Partisil 10 ODS-3 reversed-phase stainless steel column and a mobile phase of acetonitrile-0.1 M ammonium acetate (90:10, v/v) adjusted to pH 4.9 with ultraviolet detection at 335 nm. The mean recovery of BFL over a concentration range of 50-400 ng/ml was 96.8 +/- 5.2%. The within-day and day-to-day coefficients of variation were 1.8-4.0 and 1.8-4.2%, respectively. The minimum detectable concentration in plasma for BFL was 5 ng/ml with a C.V. of less than 10%. This method was found to be suitable for clinical pharmacokinetic studies.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  15. Memon AH, Ismail Z, Al-Suede FS, Aisha AF, Hamil MS, Saeed MA, et al.
    Molecules, 2015;20(8):14212-33.
    PMID: 26248073 DOI: 10.3390/molecules200814212
    Two flavanones named (2S)-7-Hydroxy-5-methoxy-6,8-dimethyl flavanone (1), (S)-5,7-dihydroxy-6,8-dimethyl-flavanone (2), along with known chalcone, namely, (E)-2',4'- dihydroxy-6'-methoxy-3',5'-dimethylchalcone (3) and two triterpenoids, namely, betulinic and ursolic acids (4 and 5), were isolated from the leaves of Syzygium campanulatum Korth (Myrtaceae). The structures of compounds (1 and 2) were determined on the basis of UV-visible, FTIR, NMR spectroscopies and LC-EIMS analytical techniques. Furthermore, new, simple, precise, selective, accurate, highly sensitive, efficient and reproducible RP-HPLC method was developed and validated for the quantitative analysis of the compounds (1-5) from S. campanulatum plants of five different age. RP-HPLC method was validated in terms of specificity, linearity (r2 ≤ 0.999), precision (2.0% RSD), and recoveries (94.4%-105%). The LOD and LOQ of these compounds ranged from 0.13-0.38 and 0.10-2.23 μg·mL-1, OPEN ACCESS respectively. Anti-proliferative activity of isolated flavanones (1 and 2) and standardized extract of S. campanulatum was evaluated on human colon cancer (HCT 116) cell line. Compounds (1 and 2) and extract revealed potent and dose-dependent activity with IC50 67.6, 132.9 and 93.4 μg·mL-1, respectively. To the best of our knowledge, this is the first study on isolation, characterization, X-ray crystallographic analysis of compounds (1 and 2) and simultaneous RP-HPLC determination of five major compounds (1-5) from different age of S. campanulatum plants.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  16. Mendes K, Harmanjeet H, Sedeeq M, Modi A, Wanandy T, Zaidi STR, et al.
    Perit Dial Int, 2018 07 10;38(6):430-440.
    PMID: 29991562 DOI: 10.3747/pdi.2017.00274
    BACKGROUND: Infections caused by ceftazidime-resistant Pseudomonas and extended-spectrum beta-lactamase (ESBL)-producing gram-negative bacteria are increasing worldwide. Meropenem and piperacillin/tazobactam (PIP/TZB) are recommended for the treatment of peritoneal dialysis-associated peritonitis (PDAP) caused by ceftazidime-resistant Pseudomonas and other resistant gram-negative bacteria. Patients may also receive intraperitoneal heparin to prevent occlusion of their catheters. However, the stability of meropenem or PIP/TZB, in combination with heparin, in different types of peritoneal dialysis (PD) solutions used in clinical practice is currently unknown. Therefore, we investigated the stability of meropenem and PIP/TZB, each in combination with heparin, in different PD solutions.

    METHODS: A total of 15 PD bags (3 bags for each type of PD solution) containing meropenem and heparin and 24 PD bags (3 bags for each type of PD solution) containing PIP/TZB and heparin were prepared and stored at 4°C for 168 hours. The same bags were stored at 25°C for 3 hours followed by 10 hours at 37°C. An aliquot withdrawn before storage and at defined time points was analyzed for the concentration of meropenem, PIP, TZB, and heparin using high-performance liquid chromatography. Samples were also analysed for particle content, pH and color change, and the anticoagulant activity of heparin.

    RESULTS: Meropenem and heparin retained more than 90% of their initial concentration in 4 out of 5 types of PD solutions when stored at 4°C for 168 hours, followed by storage at 25°C for 3 hours and then at 37°C for 10 hours. Piperacillin/tazobactam and heparin were found to be stable in all 8 types of PD solutions when stored under the same conditions. Heparin retained more than 98% of its initial anticoagulant activity throughout the study period. No evidence of particle formation, color change, or pH change was observed at any time under the storage conditions employed in the study.

    CONCLUSIONS: This study provides clinically important information on the stability of meropenem and PIP/TZB, each in combination with heparin, in different PD solutions. The use of meropenem-heparin admixed in pH-neutral PD solutions for the treatment of PDAP should be avoided, given the observed suboptimal stability of meropenem.

    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  17. Miean KH, Mohamed S
    J Agric Food Chem, 2001 Jun;49(6):3106-12.
    PMID: 11410016
    Studies were conducted on the flavonoids (myricetin, quercetin, kaempferol, luteolin, and apigenin) contents of 62 edible tropical plants. The highest total flavonoids content was in onion leaves (1497.5 mg/kg quercetin, 391.0 mg/kg luteolin, and 832.0 mg/kg kaempferol), followed by Semambu leaves (2041.0 mg/kg), bird chili (1663.0 mg/kg), black tea (1491.0 mg/kg), papaya shoots (1264.0 mg/kg), and guava (1128.5 mg/kg). The major flavonoid in these plant extracts is quercetin, followed by myricetin and kaempferol. Luteolin could be detected only in broccoli (74.5 mg/kg dry weight), green chili (33.0 mg/kg), bird chili (1035.0 mg/kg), onion leaves (391.0 mg/kg), belimbi fruit (202.0 mg/kg), belimbi leaves (464.5 mg/kg), French bean (11.0 mg/kg), carrot (37.5 mg/kg), white radish (9.0 mg/kg), local celery (80.5 mg/kg), limau purut leaves (30.5 mg/kg), and dried asam gelugur (107.5 mg/kg). Apigenin was found only in Chinese cabbage (187.0 mg/kg), bell pepper (272.0 mg/kg), garlic (217.0 mg/kg), belimbi fruit (458.0 mg/kg), French peas (176.0 mg/kg), snake gourd (42.4 mg/kg), guava (579.0 mg/kg), wolfberry leaves (547.0 mg/kg), local celery (338.5 mg/kg), daun turi (39.5 mg/kg), and kadok (34.5 mg/kg). In vegetables, quercetin glycosides predominate, but glycosides of kaempferol, luteolin, and apigenin are also present. Fruits contain almost exclusively quercetin glycosides, whereas kaempferol and myricetin glycosides are found only in trace quantities.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  18. Mohamad Hanapi NS, Sanagi MM, Ismail AK, Saim N, Wan Ibrahim WN, Wan Ibrahim WA, et al.
    J Chromatogr Sci, 2018 Feb 01;56(2):166-176.
    PMID: 29069322 DOI: 10.1093/chromsci/bmx092
    Two-phase micro-electrodriven membrane extraction (EME) procedure for the pre-concentration of selected non-steroidal anti-inflammatory drugs (NSAIDs) in aquatic matrices was investigated. Agarose film was used as interface between donor and acceptor phase in EME which allowed for selective extraction of the analytes prior to high performance liquid chromatography-ultraviolet detection. Charged analytes were transported from basic aqueous sample solution through agarose film into 1-octanol as an acceptor phase at 9 V potential. Response surface methodology in conjunction with the central composite design showed good correlations between extraction time and applied voltage (R2 > 0.9358). Under optimized extraction conditions, the method showed good linearity in the concentration range of 0.5-500 μg L-1 with coefficients of determination, r2≥ 0.9942 and good limits of detection (0.14-0.42 μg L-1) and limits of quantification (0.52-1.21 μg L-1). The results also showed high enrichment factors (62-86) and good relative recoveries (72-114%) with acceptable reproducibilities (RSDs ≤ 7.5% n = 3). The method was successfully applied to the determination of NSAIDs from tap water and river water samples. The proposed method proved to be rapid, simple and requires low voltage and minute amounts of organic solvent, thus environmentally friendly.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
  19. Mohamad Hanapi NS, Sanagi MM, Ismail AK, Wan Ibrahim WA, Saim N, Wan Ibrahim WN
    PMID: 28142101 DOI: 10.1016/j.jchromb.2017.01.028
    The aim of this study was to investigate and apply supported ionic liquid membrane (SILM) in two-phase micro-electrodriven membrane extraction combined with high performance liquid chromatography-ultraviolet detection (HPLC-UV) for pre-concentration and determination of three selected antidepressant drugs in water samples. A thin agarose film impregnated with 1-hexyl-3-methylimidazolium hexafluorophosphate, [C6MIM] [PF6], was prepared and used as supported ionic liquid membrane between aqueous sample solution and acceptor phase for extraction of imipramine, amitriptyline and chlorpromazine. Under the optimized extraction conditions, the method provided good linearity in the range of 1.0-1000μgL(-1), good coefficients of determination (r(2)=0.9974-0.9992) and low limits of detection (0.1-0.4μgL(-1)). The method showed high enrichment factors in the range of 110-150 and high relative recoveries in the range of 88.2-111.4% and 90.9-107.0%, for river water and tap water samples, respectively with RSDs of ≤7.6 (n=3). This method was successfully applied to the determination of the drugs in river and tap water samples. It is envisaged that the SILM improved the perm-selectivity by providing a pathway for targeted analytes which resulted in rapid extraction with high degree of selectivity and high enrichment factor.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods
  20. Mohd Hazli UHA, Abdul-Aziz A, Mat-Junit S, Chee CF, Kong KW
    Food Res Int, 2019 01;115:241-250.
    PMID: 30599938 DOI: 10.1016/j.foodres.2018.08.094
    Alternanthera sessilis (red) (ASR) is an edible herbal plant with many beneficial health effects. This study aimed to investigate the antioxidant components and antioxidant activities of the edible leaves and stems of ASR extracted using solvent of varying polarities namely water, ethanol, ethyl acetate and hexane. ASR leaf extracts showed higher in both antioxidant components and activities than the stem extracts. Among the antioxidant components, the ethanol leaf extract showed higher phenolic (77.29 ± 1.02 mg GAE/g extract) content while the ethyl acetate leaf extract was rich in flavonoids (157.44 ± 10.19 mg RE/g extract), carotenoids (782.97 ± 10.78 mg BE/g extract) and betalains (betanin: 67.08 ± 0.49 mg/g extract; amaranthin: 93.94 ± 0.68 mg/g extract and betaxanthin: 53.92 ± 0.88 mg/g extract). Nevertheless, the ethanol leaf extract showed the highest DPPH radical scavenging activity and ABTS radical cation scavenging activity. It also exhibited highest ferric reducing activity among all the extracts. Four polyphenolic compounds from ASR leaf, namely ferulic acid, rutin, quercetin and apigenin, were identified and quantified using ultra high performance liquid chromatography. The existence of these compounds was further verified using tandem mass spectrometry. These current results indicate that ASR leaf particularly the ethanol extract has the potential to be exploited as a source of natural antioxidants.
    Matched MeSH terms: Chromatography, High Pressure Liquid/methods*
Filters