Displaying publications 61 - 80 of 227 in total

Abstract:
Sort:
  1. Khalik WF, Ho LN, Ong SA, Voon CH, Wong YS, Yusuf SY, et al.
    Environ Sci Pollut Res Int, 2018 Dec;25(35):35164-35175.
    PMID: 30328543 DOI: 10.1007/s11356-018-3414-z
    The objective of this study was to investigate several operating parameters, such as open circuit, different external resistance, pH, supporting electrolyte, and presence of aeration that might enhance the degradation rate as well as electricity generation of batik wastewater in solar photocatalytic fuel cell (PFC). The optimum degradation of batik wastewater was at pH 9 with external resistor 250 Ω. It was observed that open circuit of PFC showed only 17.2 ± 7.5% of removal efficiency, meanwhile the degradation rate of batik wastewater was enhanced to 31.9 ± 15.0% for closed circuit with external resistor 250 Ω. The decolorization of batik wastewater in the absence of photocatalyst due to the absorption of light irradiation by dye molecules and this process was known as photolysis. The degradation of batik wastewater increased as the external resistor value decreased. In addition, the degradation rate of batik wastewater also increased at pH 9 which was 74.4 ± 34.9% and at pH 3, its degradation rate was reduced to 19.4 ± 8.7%. The presence of aeration and sodium chloride as supporting electrolyte in batik wastewater also affected its degradation and electricity generation. The maximum absorbance of wavelength (λmax) of batik wastewater at 535 nm and chemical oxygen demand gradually decreased as increased in irradiation time; however, batik wastewater required prolonged irradiation time to fully degrade and mineralize in PFC system.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  2. Asaithambi P, Aziz ARA, Sajjadi B, Daud WMABW
    Environ Sci Pollut Res Int, 2017 Feb;24(6):5168-5178.
    PMID: 27221586 DOI: 10.1007/s11356-016-6909-5
    In the present work, the efficiency of the sonication, electrocoagulation, and sono-electrocoagulation process for removal of pollutants from the industrial effluent of the pulp and paper industry was compared. The experimental results showed that the sono-electrocoagulation process yielded higher pollutant removal percentage compared to the sonication and electrocoagulation process alone. The effect of the operating parameters in the sono-electrocoagulation process such as electrolyte concentration (1-5 g/L), current density (1-5 A/dm(2)), effluent pH (3-11), COD concentration (1500-6000 mg/L), inter-electrode distance (1-3 cm), and electrode combination (Fe and Al) on the color removal, COD removal, and power consumption were studied. The maximum color and COD removal percentages of 100 and 95 %, respectively, were obtained at the current density of 4 A/dm(2), electrolyte concentration of 4 g/L, effluent pH of 7, COD concentration of 3000 mg/L, electrode combination of Fe/Fe, inter-electrode distance of 1 cm, and reaction time of 4 h, respectively. The color and COD removal percentages were analyzed by using an UV/Vis spectrophotometer and closed reflux method. The results showed that the sono-electrocoagulation process could be used as an efficient and environmental friendly technique for complete pollutant removal.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  3. Lim JW, Lim PE, Seng CE, Adnan R
    Environ Sci Pollut Res Int, 2014 Jan;21(1):485-94.
    PMID: 23807562 DOI: 10.1007/s11356-013-1933-1
    The feasibility of using dried attached-growth biomass from the polyurethane (PU) foam cubes as a solid carbon source to enhance the denitrification process in the intermittently aerated moving bed sequencing batch reactor (IA-MBSBR) during the treatment of low COD/N containing wastewater was investigated. By packing the IA-MBSBR with 8% (v/v) of 8-mL PU foam cubes saturated with dried attached-growth biomass, total nitrogen removal efficiency of 80% could be achieved for 10 consecutive cycles of operation when the intermittent aeration strategy of consecutive 1 h of aeration followed by 2 h of non-aeration period during the REACT period of the IA-MBSBR was adopted. Negligible release of ammonium nitrogen (NH4(+)-N) and slow-release of COD from the dried biomass would ensure that the use of this solid carbon source would not further burden the treatment system. The slow-releasing COD was found to have no effect in promoting the assimilation process and would also allow the carbon source to be used for many cycles of operation. The 'carbon-spent' PU foam cubes could be reused by merely drying at 60 °C at the end of the operational mode. Thus, the dried attached-growth biomass formed on the PU foam cubes could be exploited as an alternative solid carbon source for the enhancement of denitrification process in the IA-MBSBR.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  4. Masudi A, Harimisa GE, Ghafar NA, Jusoh NWC
    Environ Sci Pollut Res Int, 2020 Feb;27(5):4664-4682.
    PMID: 31873891 DOI: 10.1007/s11356-019-07415-w
    The increasing number and concentration of organic pollutants in water stream could become a serious threat in the near future. Magnetite has the potential to degrade pollutants via photocatalysis with a convenient separation process. This study discusses in detail the control size and morphology of magnetite nanoparticles, and their composites with co-precipitation, hydrothermal, sol-gel, and electrochemical route. Further photocatalytic enhancement with the addition of metal and porous support was proposed. This paper also discussed the technology to extend the lifetime of recombination through an in-depth explanation of charge transfer. The possibility to use waste materials as catalyst support was also elucidated. However, magnetite-based photocatalysts still require many improvements to meet commercialization criteria.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  5. Hapiz A, Jawad AH, Alothman ZA, Wilson LD
    Int J Phytoremediation, 2024 May;26(7):1064-1075.
    PMID: 38084662 DOI: 10.1080/15226514.2023.2288904
    In this study, pineapple crown (PC) feedstock residues were utilized as a potential precursor toward producing activated carbon (PCAC) via pyrolysis induced with ZnCl2 activation. The PCAC has a surface area (457.8 m2/g) and a mesoporous structure with an average pore diameter of 3.35 nm, according to the Brunauer-Emmett-Teller estimate. The removal of cationic dye (Fuchsin basic; FB) was used for investigating the adsorption parameters of PCAC. The optimization of significant adsorption variables (A: PCAC dose (0.02-0.1 g/100 mL); B: pH (4-10); C: time (10-90); and D: initial FB concentration (10-50 mg/L) was conducted using the Box-Behnken design (BBD). The pseudo-second-order (PSO) model characterized the dye adsorption kinetic profile, whereas the Freundlich model reflected the equilibrium adsorption profile. The maximum adsorption capacity (qmax) of PCAC for FB dye was determined to be 171.5 mg/g. Numerous factors contribute to the FB dye adsorption mechanism onto the surface of PCAC, which include electrostatic attraction, H-bonding, pore diffusion, and π-π stacking. This study illustrates the utilization of PC biomass feedstock for the fabrication of PCAC and its successful application in wastewater remediation.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  6. Musa MA, Idrus S, Harun MR, Tuan Mohd Marzuki TF, Abdul Wahab AM
    PMID: 31906118 DOI: 10.3390/ijerph17010283
    Cattle slaughterhouses generate wastewater that is rich in organic contaminant and nutrients, which is considered as high strength wastewater with a high potential for energy recovery. Work was undertaken to evaluate the efficiency of the 12 L laboratory scale conventional and a modified upflow anaerobic sludge blanket (UASB) reactors (conventional, R1 and modified, R2), for treatment of cattle slaughterhouse wastewater (CSWW) under mesophilic condition (35 ± 1 °C). Both reactors were acclimated with synthetic wastewater for 30 days, then continuous study with real CSWW proceeds. The reactors were subjected to the same loading condition of OLR, starting from 1.75, 3, 5 10, 14, and 16 g L-1d-1, corresponding to 3.5, 6, 10, 20, 28, and 32 g COD/L at constant hydraulic retention time (HRT) of 24 h. The performance of the R1 reactor drastically dropped at OLR 10 g L-1d-1, and this significantly affected the subsequent stages. The steady-state performance of the R2 reactor under the same loading condition as the R1 reactor revealed a high COD removal efficiency of 94% and biogas and methane productions were 27 L/d and 89%. The SMP was 0.21 LCH4/gCOD added, whereas the NH3-N alkalinity ratio stood at 651 mg/L and 0.2. SEM showed that the R2 reactor was dominated by Methanosarcina bacterial species, while the R1 reactor revealed a disturb sludge with insufficient microbial biomass.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  7. Imron MF, Hestianingsi WOA, Putranto TWC, Citrasari N, Abdullah SRS, Hasan HA, et al.
    Chemosphere, 2024 Apr;353:141595.
    PMID: 38438021 DOI: 10.1016/j.chemosphere.2024.141595
    Increasing aquaculture cultivation produces large quantities of wastewater. If not handled properly, it can have negative impacts on the environment. Constructed wetlands (CWs) are one of the phytoremediation methods that can be applied to treat aquaculture effluent. This research was aimed at determining the performance of Cyperus rotundus in removing COD, BOD, TSS, turbidity, ammonia, nitrate, nitrite, and phosphate from the batch CW system. Treatment was carried out for 30 days with variations in the number of plants (10, 15, and 20) and variations in media height (10, 12, and 14 cm). The result showed that aquaculture effluent contains high levels of organic compounds and nutrients, and C. rotundus can grow and thrive in 100% of aquaculture effluent. Besides that, the use of C. rotundus in CWs with the effect of numbers of plants and media height showed performance of COD, BOD, TSS, turbidity, ammonia, nitrate, nitrite, and phosphate with 70, 79, 90, 96, 64, 82, 92, and 48% of removal efficacy, respectively. There was no negative impact observed on C. rotundus growth after exposure to aquaculture effluent, as indicated by the increase in wet weight, dry weight, and growth rate when compared to the control. Thus, adding aquaculture effluent to CWs planted with C. rotundus supports the growth and development of plants while also performing phytoremediation.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  8. Khalil M, Hanif MA, Rashid U, Ahmad J, Alsalme A, Tsubota T
    Environ Sci Pollut Res Int, 2023 Jul;30(34):81333-81351.
    PMID: 35710971 DOI: 10.1007/s11356-022-21367-8
    The hazardous dyes on mixing with water resources are affecting many life forms. Granite stone is popular worldwide for decorating floors, making other forms of decorative materials and items. Granite stone powder waste can be obtained free of cost from marble factories as factories spend on the disposal of this waste. In the present study, novel granite stone powder waste composite has been prepared and utilized for the effective removal of Terasil dye. Two types of granite including gray granite and white granite were used in pure, calcinized, and chemically modified forms. Freundlich adsorption isotherm model best explained the adsorption mechanism of dye removal using granite composites as compared to other adsorption isothermal models. Characterization techniques like scanning electron microscopy (SEM) and Fourier transform infrared (FTIR) spectroscopy were used for the determination of morphological features and functional groups of granite composites. The obtained results were statistically analyzed using analysis of variance (ANOVA) along with the post hoc Tukey test. An extraordinarily high Terasil dye uptake capacity (more than 400 mg/g) was exhibited by granite composites prepared using sodium metasilicate. The synthesized novel nano-constructed composites provided a viable strategy as compared to the pure granite stone for dye removal from wastewater water.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  9. Kumar R, Basu A, Bishayee B, Chatterjee RP, Behera M, Ang WL, et al.
    Environ Res, 2023 Jul 15;229:115881.
    PMID: 37084947 DOI: 10.1016/j.envres.2023.115881
    Tanning and other leather processing methods utilize a large amount of freshwater, dyes, chemicals, and salts and produce toxic waste, raising questions regarding their environmental sensitivity and eco-friendly nature. Total suspended solids, total dissolved solids, chemical oxygen demand, and ions such as chromium, sulfate, and chloride turn tannery wastewater exceedingly toxic for any living species. Therefore, it is imperative to treat tannery effluent, and existing plants must be examined and upgraded to keep up with recent technological developments. Different conventional techniques to treat tannery wastewater have been reported based on their pollutant removal efficiencies, advantages, and disadvantages. Research on photo-assisted catalyst-enhanced deterioration has inferred that both homogeneous and heterogeneous catalysis can be established as green initiatives, the latter being more efficient at degrading organic pollutants. However, the scientific community experiences significant problems developing a feasible treatment technique owing to the long degradation times and low removal efficiency. Hence, there is a chance for an improved solution to the problem of treating tannery wastewater through the development of a hybrid technology that uses flocculation as the primary treatment, a unique integrated photo-catalyst in a precision-designed reactor as the secondary method, and finally, membrane-based tertiary treatment to recover the spent catalyst and reclaimable water. This review gives an understanding of the progressive advancement of a cutting-edge membrane-based system for the management of tanning industrial waste effluents towards the reclamation of clean water. Adaptable routes toward sludge disposal and the reviews on techno-economic assessments have been shown in detail, strengthening the scale-up confidence for implementing such innovative hybrid systems.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  10. Oruganti RK, Katam K, Show PL, Gadhamshetty V, Upadhyayula VKK, Bhattacharyya D
    Bioengineered, 2022 Apr;13(4):10412-10453.
    PMID: 35441582 DOI: 10.1080/21655979.2022.2056823
    The scarcity of water resources and environmental pollution have highlighted the need for sustainable wastewater treatment. Existing conventional treatment systems are energy-intensive and not always able to meet stringent disposal standards. Recently, algal-bacterial systems have emerged as environmentally friendly sustainable processes for wastewater treatment and resource recovery. The algal-bacterial systems work on the principle of the symbiotic relationship between algae and bacteria. This paper comprehensively discusses the most recent studies on algal-bacterial systems for wastewater treatment, factors affecting the treatment, and aspects of resource recovery from the biomass. The algal-bacterial interaction includes cell-to-cell communication, substrate exchange, and horizontal gene transfer. The quorum sensing (QS) molecules and their effects on algal-bacterial interactions are briefly discussed. The effect of the factors such as pH, temperature, C/N/P ratio, light intensity, and external aeration on the algal-bacterial systems have been discussed. An overview of the modeling aspects of algal-bacterial systems has been provided. The algal-bacterial systems have the potential for removing micropollutants because of the diverse possible interactions between algae-bacteria. The removal mechanisms of micropollutants - sorption, biodegradation, and photodegradation, have been reviewed. The harvesting methods and resource recovery aspects have been presented. The major challenges associated with algal-bacterial systems for real scale implementation and future perspectives have been discussed. Integrating wastewater treatment with the algal biorefinery concept reduces the overall waste component in a wastewater treatment system by converting the biomass into a useful product, resulting in a sustainable system that contributes to the circular bioeconomy.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  11. Bani-Melhem K, Elektorowicz M, Tawalbeh M, Al Bsoul A, El Gendy A, Kamyab H, et al.
    Chemosphere, 2023 Oct;339:139693.
    PMID: 37536541 DOI: 10.1016/j.chemosphere.2023.139693
    Treating and reusing wastewater has become an essential aspect of water management worldwide. However, the increase in emerging pollutants such as polycyclic aromatic hydrocarbons (PAHs), which are presented in wastewater from various sources like industry, roads, and household waste, makes their removal difficult due to their low concentration, stability, and ability to combine with other organic substances. Therefore, treating a low load of wastewater is an attractive option. The study aimed to address membrane fouling in the submerged membrane bioreactor (SMBR) used for wastewater treatment. An aluminum electrocoagulation (EC) device was combined with SMBR as a pre-treatment to reduce fouling. The EC-SMBR process was compared with a conventional SMBR without EC, fed with real grey water. To prevent impeding biological growth, low voltage gradients were utilized in the EC deviceThe comparison was conducted over 60 days with constant transmembrane pressure and infinite solid retention time (SRT). In phase I, when the EC device was operated at a low voltage gradient (0.64 V/cm), no significant improvement in the pollutants removal was observed in terms of color, turbidity, and chemical oxygen demand (COD). Nevertheless, during phase II, a voltage gradient of 1.26 V/cm achieved up to 100%, 99.7%, 92%, 94.1%, and 96.5% removals in the EC-SMBR process in comparison with 95.1%, 95.4%, 85%, 91.7% and 74.2% removals in the SMBR process for turbidity, color, COD, ammonia nitrogen (NH3-N), total phosphorus (TP), respectively. SMBR showed better anionic surfactant (AS) removal than EC-SMBR. A voltage gradient of 0.64 V/cm in the EC unit significantly reduced fouling by 23.7%, while 1.26 V/cm showed inconsistent results. Accumulation of Al ions negatively affected membrane performance. Low voltage gradients in EC can control SMBR fouling if Al concentration is controlled. Future research should investigate EC-SMBR with constant membrane flux for large-scale applications, considering energy consumption and operating costs.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  12. Jagaba AH, Lawal IM, Ghfar AA, Usman AK, Yaro NSA, Noor A, et al.
    Chemosphere, 2023 Oct;339:139620.
    PMID: 37524265 DOI: 10.1016/j.chemosphere.2023.139620
    Agro-industrial biorefinery effluent (AIBW) is considered a highly polluting source responsible for environmental contamination. It contains high loads of chemical oxygen demand (COD), and phenol, with several other organic and inorganic constituents. Thus, an economic treatment approach is required for the sustainable discharge of the effluent. The long-term process performance, contaminant removal and microbial response of AIBW to rice straw-based biochar (RSB) and biochar-based geopolymer nanocomposite (BGC) as biosorbents in an activated sludge process were investigated. The adsorbents operated in an extended aeration system with a varied hydraulic retention time of between 0.5 and 1.5 d and an AIBW concentration of 40-100% for COD and phenol removal under standard conditions. Response surface methodology was utilised to optimize the process variables of the bioreactor system. Process results indicated a significant reduction of COD (79.51%, 98.01%) and phenol (61.94%, 74.44%) for BEAS and GEAS bioreactors respectively, at 1 d HRT and AIBW of 70%. Kinetic model analysis indicated that the Stover-Kincannon model best describes the system functionality, while the Grau model was better in predicting substrate removal rate and both with a precision of between R2 (0.9008-0.9988). Microbial communities examined indicated the abundance of genera, following the biosorbent addition, while RSB and BGC had no negative effect on the bioreactor's performance and bacterial community structure of biomass. Proteobacteria and Bacteroidetes were abundant in BEAS. While the GEAS achieved higher COD and phenol removal due to high Nitrosomonas, Nitrospira, Comamonas, Methanomethylovorans and Acinetobacter abundance in the activated sludge. Thus, this study demonstrated that the combination of biosorption and activated sludge processes could be promising, highly efficient, and most economical for AIBW treatment, without jeopardising the elimination of pollutants or the development of microbial communities.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  13. Aziz HA, Othman N, Yusuff MS, Basri DR, Ashaari FA, Adlan MN, et al.
    Environ Int, 2001 May;26(5-6):395-9.
    PMID: 11392757
    This paper discusses heavy metal removal from wastewater by batch study and filtration technique through low-cost coarse media. Batch study has indicated that more than 90% copper (Cu) with concentration up to 50 mg/l could be removed from the solution with limestone quantity above 20 ml (equivalent to 56 g), which indicates the importance of limestone media in the removal process. This indicates that the removal of Cu is influenced by the media and not solely by the pH. Batch experiments using limestone and activated carbon indicate that both limestone and activated carbon had similar metal-removal efficiency (about 95%). Results of the laboratory-scale filtration technique using limestone particles indicated that above 90% removal of Cu was achieved at retention time of 2.31 h, surface-loading rate of 4.07 m3/m2 per day and Cu loading of 0.02 kg/m3 per day. Analyses of the limestone media after filtration indicated that adsorption and absorption processes were among the mechanisms involved in the removal processes. This study indicated that limestone can be used as an alternative to replace activated carbon.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  14. Chen A, Zhang H, Zi Y, Gao Y, Lee CT, Li C
    J Environ Manage, 2025 Jan;373:123709.
    PMID: 39724672 DOI: 10.1016/j.jenvman.2024.123709
    Nutrient recovery from aquaculture sludge is vital for promoting hydroponic plant growth and achieving near-zero solid waste discharge in aquaponic systems. Modified biological aerated filters (MBAFs) are promising because of the dual capabilities of aquaculture sludge collection and aerobic mineralization. However, the bioconversion kinetics, which is indirectly related to the packed media, need to be improved. In this study, a novel polyhedral hollow sphere (PHS) medium was used in an MBAF (MBAF-PHS) to overcome the shortcomings of the current medium, facilitating fish sludge retention and enhancing subsequent bioconversion kinetics for nutrient recovery. An average rate of 36.9 g/d for dry weight of fish sludge was achieved during 29 d of filtration and an average reduction rate of 31.30 g/d during 26 d of bioconversion. The total mass of fish sludge was converted by 76.2% via the co-action of the solubilization of organic solids and degradation of dissolved organic matter. MBAF-PHS was competitive for macronutrient recovery compared with the MBAF-sponge previously used. The ratios of the final concentrations of the macronutrients (P, Mg, and S) to the concentrations in Hoagland solution (Cf/CH, %) were 278.1, 162.8, and 200.9%, respectively, whereas the ratios of N, K, and Ca were 65.9, 37.1, and 51.0%, respectively. High bioconversion kinetics of NO3--N and PO43--P were obtained within 7 d with an MNO3-N/MTN of 79.9% and MPO4-P/MDTP of 80.3%. The nutrient bioconversion of fish sludge was associated with the diversity of the microbial community in the MBAF-PHS, especially the population of nitrogen-removing microbial species that developed after 9 d of mineralization.
    Matched MeSH terms: Waste Disposal, Fluid/methods
  15. Liew WL, Kassim MA, Muda K, Loh SK, Affam AC
    J Environ Manage, 2015 Feb 1;149:222-35.
    PMID: 25463585 DOI: 10.1016/j.jenvman.2014.10.016
    The Malaysian palm oil industry is a major revenue earner and the country is ranked as one of the largest producers in the world. However, growth of the industry is synonymous with a massive production of agro-industrial wastewater. As an environmental protection and public health concern, the highly polluting palm oil mill effluent (POME) has become a major attention-grabber. Hence, the industry is targeting for POME pollution abatement in order to promote a greener image of palm oil and to achieve sustainability. At present, most palm oil mills have adopted the ponding system for treatment. Due to the successful POME pollution abatement experiences, Malaysia is currently planning to revise the effluent quality standards towards a more stringent discharge limits. Hence, the current trend of POME research focuses on developing tertiary treatment or polishing systems for better effluent management. Biotechnologically-advanced POME tertiary (polishing) technologies as well as other physicochemical methods are gaining much attention as these processes are the key players to push the industry towards the goal of environmental sustainability. There are still ongoing treatment technologies being researched and the outcomes maybe available in a while. However, the research completed so far are compiled herein and reported for the first time to acquire a better perspective and insight on the subject with a view of meeting the new standards. To this end, the most feasible technology could be the combination of advanced biological processes (bioreactor systems) with extended aeration, followed by solids separation prior to discharge. Chemical dosing is favoured only if effluent of higher quality is anticipated.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  16. Jong VS, Tang FE
    Water Sci Technol, 2014;70(2):352-60.
    PMID: 25051484 DOI: 10.2166/wst.2014.237
    A two-staged engineered wetland-based system was designed and constructed to treat raw domestic septage. Hydraulic loading rates (HLRs) of 8.75 and 17.5 cm/d were studied with four and eight daily dosings at the second stage of the system to investigate the influence of the regimes on septage treatment. Removal of organic matter (OM) was found to be HLR dependent, where the results indicated that the increase of HLR from 8.75 to 17.5 cm/d impaired the overall level of treatment in the wetland units. Effluent of wetland fed at HLR 17.5 cm/d presented significantly lower oxygen reduction potential and dissolved oxygen values than wetland fed at 8.75 cm/d, indicative of the occurrence of less aerobic and reductive conditions in the bed. The reoxygenation capability of the wetland units was found to be heavily affected by the dosing frequency especially under high hydraulic load (17.5 cm/d). NH3-N degradation was found to decrease with statistical importance when the wetland was flushed two times more frequently with smaller batches of influent. The number of hydraulic load fractionings did not seem to affect the level of treatments of OM and ammonia for both the wetlands fed under the lower HLR of 8.75 cm/d. Prediction of hydraulic limits and management of the feeding strategies are important in the vertical type of engineered wetlands to guarantee the treatment performance and minimize the chances of filter clogging.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  17. Al-Dulaimi RI, Ismail N, Ibrahim MH
    Ann Agric Environ Med, 2014;21(1):42-8.
    PMID: 24847548
    Water is one of the most important precious resources found on the earth, and are most often affected by anthropogenic activities and by industry. Pollution caused by human beings and industries is a serious concern throughout the world. Population growth, massive urbanization, rapid rate of industrialization and modern techniques in agriculture have accelerated water pollution and led to the gradual deterioration of its quality. A large quantity of waste water disposed of at sea or on land has caused environmental problems which have led to environmental pollution, economic losses and chemical risks caused by the wastewater, and its impact on agriculture. However, waste water which contain nutrients and organic matter has possible advantages for agricultural purposes. Therefore, the presented study was undertaken to assess the impact of Dairy Effluent (treated and untreated waste water) on seed germination, seedling growth, dry matter production and the biochemical parameters of lady's fingers (Abelmoschus esculentus L.).
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  18. Harun H, Anuar AN, Ujang Z, Rosman NH, Othman I
    Water Sci Technol, 2014;69(11):2252-7.
    PMID: 24901619 DOI: 10.2166/wst.2014.156
    Aerobic granular sludge (AGS) has been applied to treat a broad range of industrial and municipal wastewater. AGS can be developed in a sequencing batch reactor (SBR) with alternating anaerobic-aerobic conditions. To provide anaerobic conditions, the mixed liquor is allowed to circulate in the reactor without air supply. The circulation flow rate of mixed liquor in anaerobic condition is the most important parameter of operation in the anaerobic-AGS processes. Therefore, this study investigates the effect of circulation rate on the performance of the SBR with AGS. Two identical reactors namely R1 and R2 were operated using fermented soy sauce wastewater at circulation rate of 14.4 and 36.0 l/h, respectively. During the anaerobic conditions, the wastewater was pumped out from the upper part of the reactor and circulated back into the bottom of the reactor for 230 min. A compact and dense AGS was observed in both reactors with a similar diameter of 2.0 mm in average, although different circulation rates were adopted. The best reactor performance was achieved in R2 with chemical oxygen demand removal rate of 89%, 90% total phosphorus removal, 79% ammonia removal, 10.1 g/l of mixed liquor suspended solids and a sludge volume index of 25 ml/g.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  19. Lim SL, Wu TY, Clarke C
    J Agric Food Chem, 2014 Jan 22;62(3):691-8.
    PMID: 24372356 DOI: 10.1021/jf404265f
    In this laboratory-scale study, earthworms were introduced as biodegraders of palm oil mill effluent (POME), which is a wastewater produced from the wet process of palm oil milling. POME was absorbed into amendments (soil or rice straw) in different ratios as feedstocks for the earthworm, Eudrilus eugeniae. The presence of earthworms led to significant increases in pH, electrical conductivity, and nutrient content but decreases in the C/N ratio (0.687-75.8%), soluble chemical oxygen demand (19.7-87.9%), and volatile solids (0.687-52.7%). However, earthworm growth was reduced in all treatments by the end of the treatment process. Rice straw was a better amendment/absorbent relative to soil, with a higher nutrient content and greater reduction in soluble chemical oxygen demand with a lower C/N ratio in the vermicompost. Among all treatments investigated, the treatment with 1 part rice straw and 3 parts POME (w/v) (RS1:3) produced the best quality vermicompost with high nutritional status.
    Matched MeSH terms: Waste Disposal, Fluid/methods*
  20. Ting SC, Ismail AR, Malek MA
    J Environ Manage, 2013 Nov 15;129:260-5.
    PMID: 23968912 DOI: 10.1016/j.jenvman.2013.07.022
    This study aims at developing a novel effluent removal management tool for septic sludge treatment plants (SSTP) using a clonal selection algorithm (CSA). The proposed CSA articulates the idea of utilizing an artificial immune system (AIS) to identify the behaviour of the SSTP, that is, using a sequence batch reactor (SBR) technology for treatment processes. The novelty of this study is the development of a predictive SSTP model for effluent discharge adopting the human immune system. Septic sludge from the individual septic tanks and package plants will be desuldged and treated in SSTP before discharging the wastewater into a waterway. The Borneo Island of Sarawak is selected as the case study. Currently, there are only two SSTPs in Sarawak, namely the Matang SSTP and the Sibu SSTP, and they are both using SBR technology. Monthly effluent discharges from 2007 to 2011 in the Matang SSTP are used in this study. Cross-validation is performed using data from the Sibu SSTP from April 2011 to July 2012. Both chemical oxygen demand (COD) and total suspended solids (TSS) in the effluent were analysed in this study. The model was validated and tested before forecasting the future effluent performance. The CSA-based SSTP model was simulated using MATLAB 7.10. The root mean square error (RMSE), mean absolute percentage error (MAPE), and correction coefficient (R) were used as performance indexes. In this study, it was found that the proposed prediction model was successful up to 84 months for the COD and 109 months for the TSS. In conclusion, the proposed CSA-based SSTP prediction model is indeed beneficial as an engineering tool to forecast the long-run performance of the SSTP and in turn, prevents infringement of future environmental balance in other towns in Sarawak.
    Matched MeSH terms: Waste Disposal, Fluid/methods*