Methods: Retrospective review of R-EBUS transbronchial biopsy for PPL over 17 months.
Results: 114 R-EBUS scans were included for analysis during the study period. Forceps biopsy was performed in 76 (66.7%) cases and cryobiopsy in 38 (33.3%) cases. Baseline demographics and lesion characteristics did not differ between the two groups. Median (interquartile range) lesion size was 3.48 (2.63-4.51) cm. Overall, 41.2% of lesions were of eccentric orientation and 15.8% adjacent orientation; only 43% were concentric in orientation. Overall diagnostic yield was 67.5% (77 out of 114). Orientation remained an important factor affecting diagnostic yield. Transbronchial cryobiopsy significantly increased the diagnostic yield in eccentrically and adjacently orientated lesions to 75.0% (18 out of 24), compared to 48.8% (20 out of 41) obtained via forceps biopsy (p<0.05); but not in concentric lesions. Cryobiopsy was associated with more mild and moderate bleeding complications compared to the forceps biopsy group.
Conclusions: Transbronchial cryobiopsy under R-EBUS guidance is a safe procedure which potentially increases diagnostic yield in eccentrically and adjacently orientated PPLs.
METHODS: Twenty-six patients on HD underwent US and CT scans on the same day, postdialysis session. QMT for rectus femoris (RF) and vastus intermedius (VI) muscles was taken at the midpoint (MID) and two-thirds (2/3) of both thighs and CSA of the RF muscle (RFCSA ), respectively. Correlation between US and CT measurements was determined by intraclass correlation coefficient (ICC) and Bland-Altman plot.
RESULTS: ICC (95% CI) computed between US and CT was 0.94 (0.87-0.97), 0.97 (0.93-0.99), 0.94 (0.87-0.97), 0.94 (0.86-0.97), and 0.92 (0.83-0.97) for RFMID , VIMID, RF2/3, VI2/3 , and RFCSA , respectively (all P < 0.001). Bland-Altman analysis indicated no bias in agreement between both methods.
CONCLUSION: The US imaging offers a valid and quick bedside assessment approach to assess muscle wasting in HD patients.
METHODS: A cross-sectional study, incorporating 195 women involved in a longitudinal cohort study. Palpation for levator integrity was performed, followed by a four-dimensional translabial ultrasound. LAM avulsion defects were diagnosed in the presence of puborectalis muscle detachment from its insertion. Post-processing analysis of ultrasound volumes for LAM integrity on TUI was performed blinded against palpation findings. Agreement between methods was assessed using Cohen's κ.
RESULTS: In all, 388 paired assessments of LAM bilaterally, were available. Sixteen (8.2%) unilateral avulsion defects were detected on palpation. Sonographically, 31 (16%) were diagnosed with avulsions: 4.6% bilateral and 11.3% unilateral. An overall agreement of 91% was observed between digital palpation and TUI, yielding a Cohen's κ of 0.32 (95% confidence interval 0.15-0.48) demonstrating "fair agreement": and implying 25% sensitivity, 98% specificity, 63% positive predictive value, and 92% negative predictive value. Analysis of the first and last 20 palpations showed no change in performance during the 13-day study period.
CONCLUSION: Assessment of LAM avulsion defects by digital palpation is feasible but may require substantial training. Confirmation by imaging is crucial, especially if the diagnosis of avulsion may influence clinical management.
OBJECTIVES: To assess the diagnostic sensitivity and specificity of US compared to UGIS for malrotation and midgut volvulus.
METHODS: A cross-sectional study was performed on 68 pediatric patients who underwent US and/or UGIS before surgery for suspected midgut volvulus or malrotation in Kuala Lumpur (PPUKM and HTA), referencing surgical outcomes as the gold standard.
RESULTS: US demonstrated a higher specificity (100%) than UGIS (83%) for diagnosing malrotation, with a slightly lower sensitivity (97% vs. 100%). For midgut volvulus, US surpassed UGIS in sensitivity (92.9% vs. 66.7%) while maintaining comparable specificity. The SMA/SMV criteria showed better sensitivity (91.1%) than the D3 assessment (78.9%) on US, though both had high specificity.
CONCLUSION: US is equivalent to UGIS for identifying malrotation and is more sensitive for detecting midgut volvulus, supporting its use as a primary diagnostic tool. The study advocates for combined US and UGIS when either yields inconclusive results, optimizing diagnostic precision for these conditions.
METHODS: The review was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. Literature search was conducted in Pubmed, Web of Science and Scopus database up to 23 October 2021. To evaluate risk and bias applicability, the Cochrane risk-of bias tool and GRADE was used. The review was registered under PROSPERO CRD42021265303.
RESULTS: A total of 2921 articles were identified. 104 full texts were examined and 26 studies included in systematic review. 11 studies performed on native kidneys and 15 studies on transplanted kidney. A wide range of impact factors was found that affect the accuracy of SWE of renal fibrosis in adult patients.
CONCLUSIONS: Compared to point SWE, two-dimensional SWE with elastogram could enable better selection of the region of interest in kidneys, leading to reproducible results. Tracking waves were attenuated as the depth from skin to region of interest increased, therefore, SWE is not recommended for overweight or obese patients. Variable transducer forces might also affect SWE reproducibility, thus, training of operators to ensure consistent operator-dependent transducer forces may be helpful.
ADVANCES IN KNOWLEDGE: This review provides a holistic insight on the efficiency of using SWE in evaluating pathological changes in native and transplanted kidneys, thereby contributing to the knowledge of its utilisation in clinical practice.