Displaying publications 81 - 100 of 166 in total

Abstract:
Sort:
  1. Subari N, Mohamad Saleh J, Md Shakaff AY, Zakaria A
    Sensors (Basel), 2012;12(10):14022-40.
    PMID: 23202033 DOI: 10.3390/s121014022
    This paper presents a comparison between data from single modality and fusion methods to classify Tualang honey as pure or adulterated using Linear Discriminant Analysis (LDA) and Principal Component Analysis (PCA) statistical classification approaches. Ten different brands of certified pure Tualang honey were obtained throughout peninsular Malaysia and Sumatera, Indonesia. Various concentrations of two types of sugar solution (beet and cane sugar) were used in this investigation to create honey samples of 20%, 40%, 60% and 80% adulteration concentrations. Honey data extracted from an electronic nose (e-nose) and Fourier Transform Infrared Spectroscopy (FTIR) were gathered, analyzed and compared based on fusion methods. Visual observation of classification plots revealed that the PCA approach able to distinct pure and adulterated honey samples better than the LDA technique. Overall, the validated classification results based on FTIR data (88.0%) gave higher classification accuracy than e-nose data (76.5%) using the LDA technique. Honey classification based on normalized low-level and intermediate-level FTIR and e-nose fusion data scored classification accuracies of 92.2% and 88.7%, respectively using the Stepwise LDA method. The results suggested that pure and adulterated honey samples were better classified using FTIR and e-nose fusion data than single modality data.
    Matched MeSH terms: Food Contamination/analysis*
  2. Chin CK, Abdullah A, Sugita-Konishi Y
    PMID: 24786411 DOI: 10.1080/19393210.2012.713028
    Exposure to aflatoxins in the adult Malaysian diet was estimated by analysing aflatoxins in 236 food composites prepared as "ready for consumption". Dietary exposure to aflatoxin B1 (AFB1) ranged from 24.3 to 34.00 ng/kg b.w./day (lower to upper bound), with peanuts being the main contributor. Estimated liver cancer risk from this exposure was 0.61-0.85 cancers/100,000 population/year, contributing 12.4%-17.3% of the liver cancer cases. Excluding AFB1 occurrence data higher than 15 µg/kg reduced exposure by 65%-91% to 2.27-11.99 ng/kg b.w./day, reducing the cancer risk to 0.06-0.30 cancers/100,000 population/year (contributing 1.2%-6.1% liver cancer cases). Reducing further the ML of AFB1 from 15 to 5 µg/kg yielded 3%-7% greater drop in the exposure to 0.47-10.26 ng/kg b.w./day with an estimated risk of 0.01-0.26 cancers/100,000 population/year (0.2%-5.1% liver cancer cases attributed to dietary AFB1). These findings indicate that current MLs are adequate in protecting Malaysians' health.
    Matched MeSH terms: Food Contamination/analysis*
  3. Nordin N, Selamat J
    PMID: 24786623 DOI: 10.1080/19393210.2012.721140
    As, Cd, Pb and Hg were analysed in commonly consumed spices and herbs in Malaysia. The range of As, Cd, Pb and Hg content was 0.24-2.54, 0.23-8.07, 1.54-8.94 and 0.06-0.52 µg g(-1), respectively. The highest concentration of Cd, Pb and Hg in spices and herbs exceeded the maximum permitted proportion, which are 1, 2 and 0.05 µg g(-1), respectively. This study suggests further monitoring of Cd, Pb and Hg on daily consumption of spices and herbs and its toxicological implication for consumers since only the amount of As was lower than the permitted concentration.
    Matched MeSH terms: Food Contamination/analysis
  4. Ngah CW, Yahya MA
    Food Chem, 2012 Oct 15;134(4):2406-10.
    PMID: 23442702 DOI: 10.1016/j.foodchem.2012.04.032
    The microwave digestion method was developed and verified for the determination of arsenic in shrimp paste samples. Experimental design for five factors (HNO(3) and H(2)O(2) volumes, sample weight, microwave power and digestion time) were used for the optimisation of sample digestion. For this purpose, two level half factorial design, which involves 16 experiments, was adopted. The concentration of arsenic was analysed by graphite furnace atomic absorption spectrometry. Design Expert® 7.0 software was used to interpret all data obtained. The combination of 2 mL HNO(3) and 1 mL H(2)O(2) volumes, 0.1g sample weight, 1400 W power and 5 min digestion time was found to be the optimum parameters required to digest the shrimp paste samples. Tests with spiked samples presented good recoveries with relative standard deviations between 0.32% and 5.35%.
    Matched MeSH terms: Food Contamination/analysis
  5. Mousa W, Ghazali FM, Jinap S, Ghazali HM, Radu S
    J Food Sci, 2013 Jan;78(1):M56-63.
    PMID: 23301606 DOI: 10.1111/j.1750-3841.2012.02986.x
    The aim of this study was to model the radial growth rate and to assess aflatoxin production by Aspergillus flavus as a function of water activity (a(w) 0.82 to 0.92) and temperature (12 to 42 °C) on polished and brown rice. The growth of the fungi, expressed as colony diameter (mm) was measured daily, and the aflatoxins were analyzed using HPLC with a fluorescence detector. The growth rates were estimated using the primary model of Baranyi, which describes the change in colony radius as a function of time. Total of 2 secondary models were used to describe the combined effects of a(w) and temperature on the growth rates. The models were validated using independent experimental data. Linear Arrhenius-Davey model proved to be the best predictor of A. flavus growth rates on polished and brown rice followed by polynomial model. The estimated optimal growth temperature was around 30 °C. A. flavus growth and aflatoxins were not detected at 0.82 a(w) on polished rice while growth and aflatoxins were detected at this a(w) between 25 and 35 °C on brown rice. The highest amounts of toxins were formed at the highest a(w) values (0.90 to 0.92) at a temperature of 20 °C after 21 d of incubation on both types of rice. Nevertheless, the consistencies of toxin production within a wider range of a(w) values occurred between 25 to 30 °C. Brown rice seems to support A. flavus growth and aflatoxin production more than the polished rice.
    Matched MeSH terms: Food Contamination/analysis
  6. Kamaruzzaman BY, Ong MC, Zaleha K, Shahbudin S
    Pak J Biol Sci, 2008 Sep 15;11(18):2249-53.
    PMID: 19137835
    Muscle and feather in tissue of 40 juveniles and 40 adult green-lipped mussel Perna veridis (L.) collected from Muar Estuary, Johor were analyzed for copper (Cu), cadmium (Cd), lead (Pb) and zinc (Zn) concentration using a fast and sensitive Inductively Coupled Plasma Mass Spectrometer (ICP-MS). In this study, the average concentration of Cu was 8.96 microg g(-1) dry weights, Cd with 0.58 microg g(-1) dry weight, Pb averaging 2.28 microg g(-1) dry weights and Zn averaged to 86.73 microg g(-1) dry weight. The highest accumulation of metal studied was found in feather sample compared to the muscle. The positive relationship of Cu, Cd, Pb and Zn with P. virdis length suggesting that the accumulation of these metals were formed in the mussel. In all cases, metal levels found were lower than the guideline of international standards of reference and the examined bivalve were not associated with enhanced metal content in their tissues and were safe within the limits for human consumption.
    Matched MeSH terms: Food Contamination/analysis
  7. Kin CM, Huat TG
    J Chromatogr Sci, 2009 Sep;47(8):694-9.
    PMID: 19772747
    A headspace single-drop microextraction (HS-SDME) procedure is optimized for the analysis of organochlorine and organophosphorous pesticide residues in food matrices, namely cucumbers and strawberries by gas chromatography with an electron capture detector. The parameters affecting the HS-SDME performance, such as selection of the extraction solvent, solvent drop volume, extraction time, temperature, stirring rate, and ionic strength, were studied and optimized. Extraction was achieved by exposing 1.5 microL toluene drop to the headspace of a 5 mL aqueous solution in a 15-mL vial and stirred at 800 rpm. The analytical parameters, such as linearity, correlation coefficients, precision, limits of detection (LOD), limits of quantification (LOQ), and recovery, were compared with those obtained from headspace solid-phase microextraction (HS-SPME) and solid-phase extraction. The mean recoveries for all three methods were all above 70% and below 104%. HS-SPME was the best method with the lowest LOD and LOQ values. Overall, the proposed HS-SDME method is acceptable in the analysis of pesticide residues in food matrices.
    Matched MeSH terms: Food Contamination/analysis*
  8. Sobhanzadeh E, Abu Bakar NK, Bin Abas MR, Nemati K
    Environ Monit Assess, 2012 Sep;184(9):5821-8.
    PMID: 21989900 DOI: 10.1007/s10661-011-2384-0
    In this study, a rapid, specific and sensitive multi-residue method based on acetonitrile extraction followed by dispersive solid-phase extraction (d-SPE) clean-up was implemented and validated for multi-class pesticide residues determination in palm oil for the first time. Liquid-liquid extraction followed by low-temperature precipitation procedure was evaluated in order to study the freezing-out clean-up efficiency to obtain high recovery yield and low co-extract fat residue in the final extract. For clean-up step, d-SPE was carried out using a combination of anhydrous magnesium sulphate (MgSO(4)), primary secondary amine, octadecyl (C(18)) and graphitized carbon black. Recovery study was performed at two concentration levels (10 and 100 ng g(-1)), yielding recovery rates between 74.52% and 97.1% with relative standard deviation values below 10% (n = 6) except diuron. Detection and quantification limits were lower than 5 and 9 ng g(-1), respectively. In addition, soft matrix effects (≤±20%) were observed for most of the studied pesticides except malathion that indicated medium (20-50%) matrix effects. The proposed method was successfully applied to the analysis of suspected palm oil samples.
    Matched MeSH terms: Food Contamination/analysis*
  9. Chik Z, Haron DE, Ahmad ED, Taha H, Mustafa AM
    PMID: 21607892 DOI: 10.1080/19440049.2011.576401
    Migration of melamine has been determined for 41 types of retail melamine-ware products in Malaysia. This study was initiated by the Ministry of Health, Malaysia, in the midst of public anxiety on the possibility of melamine leaching into foods that come into contact with the melamine-ware. Thus, the objective of this study was to investigate the level of melamine migration in melamine utensils available on the market. Samples of melamine tableware, including cups and plates, forks and spoons, tumblers, bowls, etc., were collected from various retail outlets. Following the test guidelines for melamine migration set by the European Committee for Standardisation (CEN 2004) with some modifications, the samples were exposed to two types of food simulants (3% acetic acid and distilled water) at three test conditions (25°C (room temperature), 70 and 100°C) for 30 min. Melamine analysis was carried out using LC-MS/MS with a HILIC column and mobile phase consisting of ammonium acetate/formic acid (0.05%) in water and ammonium acetate/formic acid (0.05%) in acetonitrile (95 : 5, v/v). The limit of quantification (LOQ) was 5 ng/ml. Melamine migration was detected from all samples. For the articles tested with distilled water, melamine migration were [median (interquartile range)] 22.2 (32.6), 49.3 (50.9), 84.9 (89.9) ng/ml at room temperature (25°C), 70 and 100°C, respectively. In 3% acetic acid, melamine migration was 31.5 (35.7), 81.5 (76.2), 122.0 (126.7) ng/ml at room temperature (25°C), 70 and 100°C, respectively. This study suggests that excessive heat and acidity may directly affect melamine migration from melamine-ware products. However the results showed that melamine migration in the tested items were well below the specific migration limit (SML) of 30 mg/kg (30,000 ng/ml) set out in European Commission Directive 2002/72/EC.
    Matched MeSH terms: Food Contamination/analysis*
  10. Khalil MI, Sulaiman SA, Gan SH
    Food Chem Toxicol, 2010 Aug-Sep;48(8-9):2388-92.
    PMID: 20595027 DOI: 10.1016/j.fct.2010.05.076
    5-Hydroxymethylfurfural (HMF) content is an indicator of the purity of honey. High concentrations of HMF in honey indicate overheating, poor storage conditions and old honey. This study investigated the HMF content of nine Malaysian honey samples, as well as the correlation of HMF formation with physicochemical properties of honey. Based on the recommendation by the International Honey Commission, three methods for the determination of HMF were used: (1) high performance liquid chromatography (HPLC), (2) White spectrophotometry and (3) Winkler spectrophotometry methods. HPLC and White spectrophotometric results yielded almost similar values, whereas the Winkler method showed higher readings. The physicochemical properties of honey (pH, free acids, lactones and total acids) showed significant correlation with HMF content and may provide parameters that could be used to make quick assessments of honey quality. The HMF content of fresh Malaysian honey samples stored for 3-6 months (at 2.80-24.87 mg/kg) was within the internationally recommended value (80 mg/kg for tropical honeys), while honey samples stored for longer periods (12-24 months) contained much higher HMF concentrations (128.19-1131.76 mg/kg). Therefore, it is recommended that honey should generally be consumed within one year, regardless of the type.
    Matched MeSH terms: Food Contamination/analysis
  11. Tuan Zainazor C, Hidayah MS, Chai LC, Tunung R, Ghazali FM, Son R
    J Microbiol Biotechnol, 2010 Feb;20(2):229-37.
    PMID: 20208424
    Recently, many cases related to viral gastroenteritis outbreaks have been reported all over the world. Noroviruses are found to be leading as the major cause of outbreaks of acute gastroenteritis. Patients with the acute gastroenteritis normally found to be positive with norovirus when stools and vomit were analyzed. This paper reviews various activities and previous reports that describe norovirus contaminated in various food matrixes and relationship between food handlers. Lately, a numbers of norovirus outbreaks have been reported which are involved fresh produce (such as vegetables, fruits), shellfish and prepared food. Food produces by infected food handlers may therefore easily contaminated. In addition, food that required much handling and have been eaten without heat treatment gave the high risk for getting foodborne illnesses. The standard method for detection of norovirus has already been available for stool samples. However, only few methods for detection of norovirus in food samples have been developed until now.
    Matched MeSH terms: Food Contamination/analysis*
  12. Sasidharan S, Prema B, Yoga LL
    Asian Pac J Trop Biomed, 2011 Apr;1(2):130-2.
    PMID: 23569742 DOI: 10.1016/S2221-1691(11)60010-5
    To evaluate the prevalence of multidrug resistant Staphylococcus aureus (S. aureus) in dairy products.
    Matched MeSH terms: Food Contamination/analysis
  13. Ang CW, Mazlin NM, Heng LY, Ismail BS, Salmijah S
    Bull Environ Contam Toxicol, 2005 Jul;75(1):170-4.
    PMID: 16228889
    Matched MeSH terms: Food Contamination/analysis*
  14. Muhamad HB, Ai TY, Sahid IB
    J Environ Sci Health B, 2008 Feb;43(2):134-40.
    PMID: 18246505 DOI: 10.1080/03601230701795072
    The purpose of this study was to develop a method for the determination of fluroxypyr (4-amino-3,5-dichloro-6-fluro2-pyridyloxyacetic acid) residue in palm oil namely crude palm oil (CPO) and crude palm kernel oil (CPKO). The method involves the extraction of the herbicide from the oil matrix followed by low temperature precipitation and finally quantification of the residues using the high performance liquid chromatography (HPLC). The extraction efficiency of the method was evaluated by conducting recovery studies. The recovery of fluroxypyr from the fortified CPO samples ranged from 78%-111% with the relative values for the coefficient of variation ranging from 1.4 to 8.6%. Furthermore, the recovery of fluroxypyr from the spiked CPKO samples ranged from 91-107% with the relative values for the coefficient of variation ranging from 0.6 to 4.5%. The minimum detection limit of fluroxypyr in CPO and CPKO was 0.05 microg/g. The method was used to determine fluroxypyr residues from the field-treated samples of CPO and CPKO. When fluroxypyr was used for weed control in oil palm plantations no residue was detected in CPO and CPKO irrespective of the sampling interval and the dosage applied at the recommended or double the manufacturer's recommended dosage.
    Matched MeSH terms: Food Contamination/analysis*
  15. Chai LC, Robin T, Ragavan UM, Gunsalam JW, Bakar FA, Ghazali FM, et al.
    Int J Food Microbiol, 2007 Jun 10;117(1):106-11.
    PMID: 17399832
    The main aim of this study was to combine the techniques of most probable number (MPN) and polymerase chain reaction (PCR) for quantifying the prevalence and numbers of Campylobacter spp. in ulam, a popular Malaysian salad dish, from a traditional wet market and two modern supermarkets in Selangor, Malaysia. A total of 309 samples of raw vegetables which are used in ulam were examined in the study. The prevalences of campylobacters in raw vegetables were, for supermarket I, Campylobacter spp., 51.9%; Campylobacter jejuni, 40.7%; and Campylobacter coli, 35.2%: for supermarket II, Campylobacter spp., 67.7%; C. jejuni, 67.7%; and C. coli, 65.7%: and for the wet market, Campylobacter spp., 29.4%; C. jejuni, 25.5%; and C. coli, 22.6%. In addition Campylobacter fetus was detected in 1.9% of raw vegetables from supermarket I. The maximum numbers of Campylobacter spp. in raw vegetables from supermarkets and the wet market were >2400 and 460 MPN/g, respectively.
    Matched MeSH terms: Food Contamination/analysis*
  16. Panda BP, Mohanta YK, Parida SP, Pradhan A, Mohanta TK, Patowary K, et al.
    Environ Pollut, 2023 Aug 01;330:121796.
    PMID: 37169242 DOI: 10.1016/j.envpol.2023.121796
    Metals are micropollutants that cannot be degraded by microorganisms and are infiltrated into various environmental media, including both freshwater and marine water. Metals from polluted water are absorbed by many aquatic species, especially fish. Fish is a staple food in the diets of many regions in the world; hence, both the type and concentration of metals accumulated and transferred from contaminated water sources to fish must be determined and assessed. In this study, the heavy metal concentration was determined and assessed in fish collected from freshwater sources via published literature and Estimated Daily Intake (EDI), Target hazard quotient (THQ), and Carcinogenic Risk (CR) analyses, aiming to examine the metal pollution in freshwater fish. The fish was used as a bioindicator, and Geographic information system (GIS) was sued to map the polluted regions. The results confirmed that Pb was detected in fish sampled at 28 locations, Cr at 24 locations, Cu and Zn at 30 locations, with values Pb detected ranging from 0.0016 mg kg-1 to 44.3 mg kg-1, Cr detected ranging from 0.07 mg kg-1 to 27 mg kg-1, Cu detected ranging from 0.031 mg kg-1 to 35.54 mg kg-1, and Zn detected ranging from 0.242 mg kg-1 to 103.2 mg kg-1. The strongest positive associations were discovered between Cu-Zn (r = 0.74, p food and its corresponding Pb and Cr intake revealed a higher incidence of both carcinogenic and non-carcinogenic health concerns attributed to Pb and Cr in the region with populations consuming the fish.
    Matched MeSH terms: Food Contamination/analysis
  17. Marikkar JM, Rana S
    J Oleo Sci, 2014;63(9):867-73.
    PMID: 25174673
    A study was conducted to detect and quantify lard stearin (LS) content in canola oil (CaO) using differential scanning calorimetry (DSC). Authentic samples of CaO were obtained from a reliable supplier and the adulterant LS were obtained through a fractional crystallization procedure as reported previously. Pure CaO samples spiked with LS in levels ranging from 5 to 15% (w/w) were analyzed using DSC to obtain their cooling and heating profiles. The results showed that samples contaminated with LS at 5% (w/w) level can be detected using characteristic contaminant peaks appearing in the higher temperature regions (0 to 70°C) of the cooling and heating curves. Pearson correlation analysis of LS content against individual DSC parameters of the adulterant peak namely peak temperature, peak area, peak onset temperature indicated that there were strong correlations between these with the LS content of the CaO admixtures. When these three parameters were engaged as variables in the execution of the stepwise regression procedure, predictive models for determination of LS content in CaO were obtained. The predictive models obtained with single DSC parameter had relatively lower coefficient of determination (R(2) value) and higher standard error than the models obtained using two DSC parameters in combination. This study concluded that the predictive models obtained with peak area and peak onset temperature of the adulteration peak would be more accurate for prediction of LS content in CaO based on the highest coefficient of determination (R(2) value) and smallest standard error.
    Matched MeSH terms: Food Contamination/analysis*
  18. Ramli MR, Siew WL, Ibrahim NA, Kuntom A, Abd Razak RA
    PMID: 25798697 DOI: 10.1080/19440049.2015.1032368
    This paper examines the processing steps of extracting palm oil from fresh fruit bunches in a way that may impact on the formation of chloropropandiol fatty esters (3-MCPD esters), particularly during refining. Diacylglycerols (DAGs) do not appear to be a critical factor when crude palm oils are extracted from various qualities of fruit bunches. Highly hydrolysed oils, in spite of the high free fatty acid (FFA) contents, did not show exceptionally high DAGs, and the oils did not display a higher formation of 3-MCPD esters upon heat treatment. However, acidity measured in terms of pH appears to have a strong impact on 3-MCPD ester formation in the crude oil when heated at high temperatures. The differences in the extraction process of crude palm oil from current commercial processes and that from a modified experimental process showed clearly the effect of acidity of the oil on the formation of 3-MCPD esters. This paper concludes that the washing or dilution step in palm oil mills removes the acidity of the vegetative materials and that a well-optimised dilution/washing step in the extraction process will play an important role in reducing formation of 3-MCPD esters in crude palm oil upon further heat processing.
    Matched MeSH terms: Food Contamination/analysis
  19. Ali N, Hashim NH, Shuib NS
    PMID: 25658149 DOI: 10.1080/19440049.2015.1011712
    The analysis of aflatoxins (B1, B2, G1 and G2) and ochratoxin A (OTA) was performed in processed spices marketed in Penang, Malaysia, using immunoaffinity columns and HPLC equipped with fluorescence detector (HPLC-FD). The processed powdered spices analysed include dried chilli, fennel, cumin, turmeric, black and white pepper, poppy seed, coriander, 'garam masala', and mixed spices for fish, meat and chicken curry. Two different studies were carried out. The limit of detection (LOD) was 0.01 ng g(-1) for each aflatoxin (AF) and 0.10 ng g(-1) for OTA (signal-to-noise ratio = 3:1). In the first study, 34 commercial processed spices analysed with a mean level, range and incidence of positive samples for total AF were 1.61 ng g(-1), 0.01-9.34 ng g(-1) and 85%, respectively, and for AFB1 were 1.38 ng g(-1), 0.01-7.68 ng g(-1) and 85%, respectively. The mean level, range and incidence of positive samples for OTA were 2.21 ng g(-1), 0.14-20.40 ng g(-1) and 79%, respectively. Natural co-occurrence of AF and OTA was found in 25 (74%) samples. In the second study of 24 commercial processed spices, the mean level, range and incidence of positive samples for total AF were 8.38 ng g(-1), 0.32-31.17 ng g(-1) and 88%, respectively, and for AFB1 were 7.31 ng g(-1), 0.32-28.43 ng g(-1) and 83%, respectively. Fifteen positive samples for total AF and two positive samples for OTA exceeded the permissible Malaysian limit of 5 ng g(-1). Contamination of both mycotoxins in spices may represent another route of exposure to consumers due to their frequent and prolonged consumption, as spices are common ingredients in popular dishes among Asian countries.
    Matched MeSH terms: Food Contamination/analysis*
  20. Leong YH, Chiang PN, Jaafar HJ, Gan CY, Majid MI
    PMID: 24392728 DOI: 10.1080/19440049.2014.880519
    A total of 126 food samples, categorised into three groups (seafood and seafood products, meat and meat products, as well as milk and dairy products) from Malaysia were analysed for polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs). The concentration of PCDD/Fs that ranged from 0.16 to 0.25 pg WHO05-TEQ g(-1) fw was found in these samples. According to the food consumption data from the Global Environment Monitoring System (GEMS) of the World Health Organization (WHO), the dietary exposures to PCDD/F from seafood and seafood products, meat and meat products, as well as milk and dairy products for the general population in Malaysia were 0.064, 0.183 and 0.736 pg WHO05-TEQ kg(-1) bw day(-1), respectively. However, the exposure was higher in seafood and seafood products (0.415 pg WHO05-TEQ kg(-1) bw day(-1)) and meat and meat products (0.317 pg WHO05-TEQ kg(-1) bw day(-1)) when the data were estimated using the Malaysian food consumption statistics. The lower exposure was observed in dairy products with an estimation of 0.365 pg WHO05-TEQ kg(-1) bw day(-1). Overall, these dietary exposure estimates were much lower than the tolerable daily intake (TDI) as recommended by WHO. Thus, it is suggested that the dietary exposure to PCDD/F does not represent a risk for human health in Malaysia.
    Matched MeSH terms: Food Contamination/analysis*