Displaying publications 81 - 100 of 1490 in total

Abstract:
Sort:
  1. Rahim RA, Thiam CK, Rahiman MH
    Sensors (Basel), 2008 Mar 27;8(4):2082-2103.
    PMID: 27879811
    The use of a personal computer together with a Data Acquisition System (DAQ) as the processing tool in optical tomography systems has been the norm ever since the beginning of process tomography. However, advancements in silicon fabrication technology allow nowadays the fabrication of powerful Digital Signal Processors (DSP) at a reasonable cost. This allows this technology to be used in an optical tomography system since data acquisition and processing can be performed within the DSP. Thus, the dependency on a personal computer and a DAQ to sample and process the external signals can be reduced or even eliminated. The DSP system was customized to control the data acquisition process of 16x16 optical sensor array, arranged in parallel beam projection. The data collected was used to reconstruct the cross sectional image of the pipeline conveyor. For image display purposes, the reconstructed image was sent to a personal computer via serial communication. This allows the use of a laptop to display the tomogram image besides performing any other offline analysis.
    Matched MeSH terms: Tomography, X-Ray Computed; Tomography, Optical
  2. Gupta K, Singh S, Singh S
    J Contemp Dent Pract, 2019 Aug 01;20(8):907-914.
    PMID: 31797846
    AIM: Assessing the accuracy of surgical guides generated with the help of a simple chair side ridge mapping technique by comparing the planned implant position with the achieved implant position on post-op computerized tomography scans.

    MATERIALS AND METHODS: In this study, 20 implant sites in patients were selected. Ridge mapping was done through a vacuum press template at three buccal (B1, B2, B3), three lingual (L1, L2, L3), and one crestal (C) points for each implant site. Readings were transferred onto the cast, and surgical guides were fabricated for implant placement. Postoperative cone beam computerized tomography (CBCT) was done to assess planned and achieved implant position. Comparison was done between soft tissue depths and implant distance from the crest of alveolar bone determined by the ridge mapping technique with measurements done on CBCT. The points used for ridge mapping were used as the reference for measurements. The data were analyzed using paired t test. p < 0.05 was considered to be statistically significant.

    RESULTS: On comparing the mean values of soft tissue depths from the ridge mapping and CBCT data, insignificant differences were found at B1, B2, L1, L2, L3, and C, but significant differences were found at B3. On comparing the implant distances from alveolar bone from both the data, insignificant differences were found at B, B2, B3, L1, L2, and L3 and significant difference was found at the crest in the mean values.

    CONCLUSION: Under the limitations of the above study, it can be concluded that a simple chairside procedure like ridge mapping can be used as an effective way for guided implant placement in sufficient available alveolar bone.

    Matched MeSH terms: Cone-Beam Computed Tomography*
  3. Tan D, Mohamad NA, Wong YH, Yeong CH, Cheah PL, Sulaiman N, et al.
    Int J Hyperthermia, 2019;36(1):554-561.
    PMID: 31132888 DOI: 10.1080/02656736.2019.1610800
    Purpose: This study aimed to evaluate the effects of various computed tomography (CT) acquisition parameters and metal artifacts on CT number measurement for CT thermometry during CT-guided thermal ablation. Methods: The effects of tube voltage (100-140 kVp), tube current (20-250 mAs), pitch (0.6-1.5) and gantry rotation time (0.5, 1.0 s) as well as metal artifacts from a radiofrequency ablation (RFA) needle on CT number were evaluated using liver tissue equivalent polyacrylamide (PAA) phantom. The correlation between CT number and temperature from 37 to 80 °C was studied on PAA phantom using optimum CT acquisition parameters. Results: No statistical significant difference (p > 0.05) was found on CT numbers under the variation of different acquisition parameters for the same temperature setting. On the other hand, the RFA needle has induced metal artifacts on the CT images of up to 8 mm. The CT numbers decreased linearly when the phantom temperature increased from 37 to 80 °C. A linear regression analysis on the CT numbers and temperature suggested that the CT thermal sensitivity was -0.521 ± 0.061 HU/°C (R2 = 0.998). Conclusion: CT thermometry is feasible for temperature assessment during RFA with the current CT technology, which produced a high CT number reproducibility and stable measurement at different CT acquisition parameters. Despite being affected by metal artifacts, the CT-based thermometry could be further developed as a tissue temperature monitoring tool during CT-guided thermal ablation.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  4. Ahmed HMA, Rossi-Fedele G
    Eur Endod J, 2020 12;5(3):159-176.
    PMID: 33353923 DOI: 10.14744/eej.2020.88942
    OBJECTIVE: Consistent reporting of publications in a given topic is essential. This systematic review aimed to identify and evaluate the reporting items in previous publications related to root canal anatomy in major Endodontic journals.

    METHODS: A systematic review was undertaken following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A comprehensive literature search was performed by 2 independent reviewers using a customized search strategy in major Endodontic journals through Scopus until November 2019. Studies investigating root and canal anatomy were included. The selected publications were divided into 7 categories according to the study design: micro-computed tomography (microCT) and cone-beam computed tomography (CBCT) experimental studies (extracted teeth), CBCT and 2D clinical studies, CBCT and 2D case reports in addition to others (i.e. staining and clearing method and root sectioning). The selected studies were evaluated according to three domains: 1) Criteria for study sample selection; 2) Criteria for methodological procedures and 3) Criteria for detection and evaluation.

    RESULTS: After the removal of duplicated and irrelevant papers, 137 articles were included. Results showed that microCT studies reported accurately the tooth type, number of teeth, classifications used, qualitative and/or quantitative analysis (if required) and the evaluation process. However, sample size calculation, calibration, and reproducibility were not reported in the majority of microCT studies. CBCT clinical studies presented information for the type of study, inclusion/exclusion criteria, number of patients, tooth type, and number of teeth. However, the majority did not report sample size calculation and calibration of examiners. Radiographic exposure descriptions and classifications used were not reported adequately in CBCT and 2D case reports. Sample size calculation, calibration and reproducibility were not reported in staining and clearing method.

    CONCLUSION: Despite accurate presentation of certain items, there is considerable inconsistent reporting of root and canal morphology regardless of the type of study and experimental procedure used. The PROUD checklist protocol presented in this systematic review aims to provide an accurate description of root canal anatomy in experimental, clinical, and case report publications.

    Matched MeSH terms: Cone-Beam Computed Tomography*
  5. Teh V, Sim KS, Wong EK
    Scanning, 2016 Nov;38(6):842-856.
    PMID: 27302216 DOI: 10.1002/sca.21334
    According to the statistic from World Health Organization (WHO), stroke is one of the major causes of death globally. Computed tomography (CT) scan is one of the main medical diagnosis system used for diagnosis of ischemic stroke. CT scan provides brain images in Digital Imaging and Communication in Medicine (DICOM) format. The presentation of CT brain images is mainly relied on the window setting (window center and window width), which converts an image from DICOM format into normal grayscale format. Nevertheless, the ordinary window parameter could not deliver a proper contrast on CT brain images for ischemic stroke detection. In this paper, a new proposed method namely gamma correction extreme-level eliminating with weighting distribution (GCELEWD) is implemented to improve the contrast on CT brain images. GCELEWD is capable of highlighting the hypodense region for diagnosis of ischemic stroke. The performance of this new proposed technique, GCELEWD, is compared with four of the existing contrast enhancement technique such as brightness preserving bi-histogram equalization (BBHE), dualistic sub-image histogram equalization (DSIHE), extreme-level eliminating histogram equalization (ELEHE), and adaptive gamma correction with weighting distribution (AGCWD). GCELEWD shows better visualization for ischemic stroke detection and higher values with image quality assessment (IQA) module. SCANNING 38:842-856, 2016. © 2016 Wiley Periodicals, Inc.
    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  6. Suppiah S
    Med J Malaysia, 2021 07;76(4):451-453.
    PMID: 34305103
    Nuclear medicine (NM) has been established in Malaysia for almost 60 years. It is a specialty that utilizes radiopharmaceuticals for theranostics, by the assessment of bodily functions to diagnose certain diseases and conditions particularly in oncology, cardiology, and neurology as well as to provide therapeutic solutions in certain instances. The strengths of NM include the establishment of various nuclear medicine centres throughout the country, including in Sabah and Sarawak, particularly for general nuclear medicine, and the mushrooming of positron emission tomography computed tomography (PET/CT) centres along the states in the west coast of Malaysia, the institution of a formal national nuclear medicine physician training programme, and collaboration with international bodies to develop theranostic services. The challenges for NM ahead are namely regulatory and financial constraints for utilizing newer radiopharmaceuticals available in the international market, expansion of accredited training programmes to produce skilled healthcare workforce, optimization of resources at hand and multidisciplinary collaborations to reduce premature mortality of patients caused by noncommunicable diseases, particularly cancer.
    Matched MeSH terms: Positron Emission Tomography Computed Tomography
  7. Teo ZL, Sun CZ, Chong CCY, Tham YC, Takahashi K, Majithia S, et al.
    Ophthalmol Retina, 2022 Nov;6(11):1080-1088.
    PMID: 35580772 DOI: 10.1016/j.oret.2022.05.010
    OBJECTIVE: To describe the normative quantitative parameters of the macular retinal vasculature, as well as their systemic and ocular associations using OCT angiography (OCTA).

    DESIGN: Population-based, cross-sectional study.

    SUBJECTS: Adults aged > 50 years were recruited from the third examination of the population-based Singapore Malay Eye Study.

    METHODS: All participants underwent a standardized comprehensive examination and spectral-domain OCTA (Optovue) of the macula. OCT angiography scans that revealed pre-existing retinal disease, revealed macular pathology, and had poor quality were excluded.

    MAIN OUTCOME MEASURES: The normative quantitative vessel densities of the superficial layer, deep layer, and foveal avascular zone (FAZ) were evaluated. Ocular and systemic associations with macular retinal vasculature parameters were also evaluated in a multivariable analysis using linear regression models with generalized estimating equation models.

    RESULTS: We included 1184 scans (1184 eyes) of 749 participants. The mean macular superficial vessel density (SVD) and deep vessel density (DVD) were 45.1 ± 4.2% (95% confidence interval [CI], 37.8%-51.4%) and 44.4 ± 5.2% (95% CI, 36.9%-53.2%), respectively. The mean SVD and DVD were highest in the superior quadrant (48.7 ± 5.9%) and nasal quadrant (52.7 ± 4.6%), respectively. The mean FAZ area and perimeter were 0.32 ± 0.11 mm2 (95% CI, 0.17-0.51 mm) and 2.14 ± 0.38 mm (95% CI, 1.54-2.75 mm), respectively. In the multivariable regression analysis, female sex was associated with higher SVD (β = 1.25, P ≤ 0.001) and DVD (β = 0.75, P = 0.021). Older age (β = -0.67, P < 0.001) was associated with lower SVD, whereas longer axial length (β = -0.42, P = 0.003) was associated with lower DVD. Female sex, shorter axial length, and worse best-corrected distance visual acuity were associated with a larger FAZ area. No association of a range of systemic parameters with vessel density was found.

    CONCLUSIONS: This study provided normative macular vasculature parameters in an adult Asian population, which may serve as reference values for quantitative interpretation of OCTA data in normal and disease states.

    Matched MeSH terms: Tomography, Optical Coherence*
  8. Tan SK, Yeong CH, Raja Aman RRA, Ng KH, Abdul Aziz YF, Chee KH, et al.
    Br J Radiol, 2018 Jul;91(1088):20170874.
    PMID: 29493261 DOI: 10.1259/bjr.20170874
    OBJECTIVE: This study aimed (1) to perform a systematic review on scanning parameters and contrast medium (CM) reduction methods used in prospectively electrocardiography (ECG-triggered low tube voltage coronary CT angiography (CCTA), (2) to compare the achievable dose reduction and image quality and (3) to propose appropriate scanning techniques and CM administration methods.

    METHODS: A systematic search was performed in PubMed, the Cochrane library, CINAHL, Web of Science, ScienceDirect and Scopus, where 20 studies were selected for analysis of scanning parameters and CM reduction methods.

    RESULTS: The mean effective dose (HE) ranged from 0.31 to 2.75 mSv at 80 kVp, 0.69 to 6.29 mSv at 100 kVp and 1.53 to 10.7 mSv at 120 kVp. Radiation dose reductions of 38 to 83% at 80 kVp and 3 to 80% at 100 kVp could be achieved with preserved image quality. Similar vessel contrast enhancement to 120 kVp could be obtained by applying iodine delivery rate (IDR) of 1.35 to 1.45 g s-1 with total iodine dose (TID) of between 10.9 and 16.2 g at 80 kVp and IDR of 1.08 to 1.70 g s-1 with TID of between 18.9 and 20.9 g at 100 kVp.

    CONCLUSION: This systematic review found that radiation doses could be reduced to a rate of 38 to 83% at 80 kVp, and 3 to 80% at 100 kVp without compromising the image quality. Advances in knowledge: The suggested appropriate scanning parameters and CM reduction methods can be used to help users in achieving diagnostic image quality with reduced radiation dose.

    Matched MeSH terms: Computed Tomography Angiography/methods*
  9. Fallahpoor M, Chakraborty S, Heshejin MT, Chegeni H, Horry MJ, Pradhan B
    Comput Biol Med, 2022 Jun;145:105464.
    PMID: 35390746 DOI: 10.1016/j.compbiomed.2022.105464
    BACKGROUND: Artificial intelligence technologies in classification/detection of COVID-19 positive cases suffer from generalizability. Moreover, accessing and preparing another large dataset is not always feasible and time-consuming. Several studies have combined smaller COVID-19 CT datasets into "supersets" to maximize the number of training samples. This study aims to assess generalizability by splitting datasets into different portions based on 3D CT images using deep learning.

    METHOD: Two large datasets, including 1110 3D CT images, were split into five segments of 20% each. Each dataset's first 20% segment was separated as a holdout test set. 3D-CNN training was performed with the remaining 80% from each dataset. Two small external datasets were also used to independently evaluate the trained models.

    RESULTS: The total combination of 80% of each dataset has an accuracy of 91% on Iranmehr and 83% on Moscow holdout test datasets. Results indicated that 80% of the primary datasets are adequate for fully training a model. The additional fine-tuning using 40% of a secondary dataset helps the model generalize to a third, unseen dataset. The highest accuracy achieved through transfer learning was 85% on LDCT dataset and 83% on Iranmehr holdout test sets when retrained on 80% of Iranmehr dataset.

    CONCLUSION: While the total combination of both datasets produced the best results, different combinations and transfer learning still produced generalizable results. Adopting the proposed methodology may help to obtain satisfactory results in the case of limited external datasets.

    Matched MeSH terms: Tomography, X-Ray Computed/methods
  10. Salah H, Rabbaa M, Abuljoud M, Babikir E, Alkhorayef M, Tamam N, et al.
    Appl Radiat Isot, 2023 Feb;192:110610.
    PMID: 36525913 DOI: 10.1016/j.apradiso.2022.110610
    In comparison to adults and paediatric are more sensitive to ionizing radiation exposure. Computed tomography (CT) is now the dominant source of medical radiologic tests for patients, accounting for more than 70% of total doses to the general public. Paediatric CT brain scans (with and without contrast) are routinely performed for a variety of clinical reasons. As a result, this parameter must be calculated in order to determine relative radiation risk. The goal of this study is to assess the radiation risk to children during CT brain diagnostic procedures. Three hundred fifty three child patients' radiation risk doses were assessed over the course of a year. The mean and ranged of the children's radiation doses were 40.6 ± 8.8 (27.8-45.8) CTDIvol (mGy) and 850 ± 230 (568.1-1126.4) DLP (mGy.cm) for the brain with contrast medium. For CT brain without contrast, the patients' doses were 40.9 ± 9.4 (14.27-64.07) CTDIvol (mGy), and 866.1 ± 289.3 (203.6-2484.9) DLP (mGy.cm). The characteristics related to the radiation dose were retrieved from the scan protocol generated by the CT system by the participating physicians after each procedure. Furthermore, optimizing the CT acquisition parameter is critical for increasing the benefit while lowering the procedure's radiogenic risk. The patients' radiation dose is comparable with the most previously published studies and international diagnostic reference levels (DRLs). Radiation dose optimization is recommended due to high sensitivity of the paediatric patients to ionizing radiation.
    Matched MeSH terms: Computed Tomography Angiography*
  11. Tuang GJ, Zahedi FD, Husain S, Hamizan AKW, Kew TY, Thanabalan J
    Int J Med Sci, 2023;20(2):211-218.
    PMID: 36794158 DOI: 10.7150/ijms.68095
    Introduction: The fundament of forensic science lies in identifying a body. The morphological complexity of the paranasal sinus (PNS), which varies greatly amongst individual, possess a discriminatory value that potentially contributes to the radiological identification. The sphenoid bone represents the keystone of the skull and forms part of the cranial vault. It is intimately associated with vital neurovascular structures. The sphenoid sinus, located within the body of the sphenoid bone, has variable morphology. The sphenoid septum's inconsistent position and the degree, as well as the direction disparities of sinus pneumatization, have indeed accorded it a unique structure in providing invaluable information in forensic personnel identification. Additionally, the sphenoid sinus is situated deep within the sphenoid bone. Therefore, it is well protected from traumatic degradation from external causes and can be potentially utilized in forensic studies. The authors aim to study the possibility of variation among the race, and gender in the Southeast Asian (SEA) population, using volumetric measurements of the sphenoid sinus. Materials and methods: This is a retrospective cross-sectional analysis of computerized tomographic (CT) imaging of the PNS of 304 patients (167 males, 137 females) in a single centre. The volume of the sphenoid sinus was reconstructed and measured using commercial real-time segmentation software. Result: The total volume of sphenoid sinus of male gender had shown to be larger, 12.22 (4.93 - 21.09) cm3 compared to the counterpart of 10.19 (3.75 - 18.72) cm3 (p = .0090). The Chinese possessed a larger total sphenoid sinus volume, 12.96 (4.62 - 22.21) cm3) than the Malays, 10.68 (4.13 - 19.25) cm3 (p = .0057). No correlation was identified between the age and volume of the sinus (cc= -.026, p = .6559). Conclusion: The sphenoid sinus volume in males was found to be larger than those of females. It was also shown that race influences sinus volume. Volumetric analysis of the sphenoid sinus can potentially be utilized in gender and race determination. The current study provided normative data on the sphenoid sinus volume in the SEA region, which can be helpful for future studies.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  12. Zahedi FD, Yaacob NM, Wang Y, Abdullah B
    Clin Otolaryngol, 2023 Mar;48(2):271-285.
    PMID: 35997634 DOI: 10.1111/coa.13975
    OBJECTIVES: To determine the anatomical variations of the lateral nasal wall and anterior skull base amongst populations in different geographical regions.

    DESIGN: Systematic review and meta-analysis.

    METHODS: Using PRISMA guidelines, SCOPUS and PUBMED databases were searched from inception until 1 March 2022. The regions and populations identified were from Europe, Asia, Middle East, Australia-New Zealand-Oceania, South America, North America and Africa. Random-effects model was used to estimate the pooled prevalence with 95% confidence intervals (CIs). Heterogeneity was assessed using the I2 statistic and Cochran's Q test.

    MAIN OUTCOME MEASURES: Anatomical variations of the lateral nasal wall and anterior skull base confirmed by computed tomography scan.

    RESULTS: Fifty-six articles were included with a total of 11 805 persons. The most common anatomical variation of the ostiomeatal complex was pneumatization of the agger nasi (84.1%), olfactory fossa was Keros type 2 (53.8%) and ethmoids was asymmetry of the roof (42.8%). Sphenoethmoidal and suprabullar cells have a higher prevalence in North Americans (53.7%, 95% CI: 46.00-61.33) while asymmetry of ethmoid roof more common in Middle Easterns (85.5%, 95% CI: .00-100). Bent uncinate process has greater prevalence in Asians while supraorbital ethmoid cells and Keros type 3 more common in non-Asians. The overall studies have substantial heterogeneity and publication bias.

    CONCLUSION: Certain anatomic variants are more common in a specific population. The 'approach of analysis' plays a role in the prevalence estimates and consensus should be made in future studies regarding the most appropriate 'approach of analysis' either by persons or by sides.

    Matched MeSH terms: Tomography, X-Ray Computed*
  13. Raman K, Govindaraju R, James K, Abu Bakar MZ, Patil N, Shah MN
    J Laryngol Otol, 2023 Feb;137(2):169-173.
    PMID: 34924062 DOI: 10.1017/S0022215121004175
    OBJECTIVE: Knowledge of anatomical variations of the frontal recess and frontal sinus and recognition of endoscopic landmarks are vital for safe and effective endoscopic sinus surgery. This study revisited an anatomical landmark in the frontal recess that could serve as a guide to the frontal sinus.

    METHOD: Prevalence of the anterior ethmoid genu, its morphology and its relationship with the frontal sinus drainage pathway was assessed. Computed tomography scans with multiplanar reconstruction were used to study non-diseased sinonasal complexes.

    RESULTS: The anterior ethmoidal genu was present in all 102 anatomical sides studied, independent of age, gender and race. Its position was within the frontal sinus drainage pathway, and the drainage pathway was medial to it in 98 of 102 cases. The anterior ethmoidal genu sometimes extended laterally and formed a recess bounded by the lamina papyracea laterally, by the uncinate process anteriorly and by the bulla ethmoidalis posteriorly. Distance of the anterior ethmoidal genu to frontal ostia can be determined by the height of the posterior wall of the agger nasi cell rather than its volume or other dimensions.

    CONCLUSION: This study confirmed that the anterior ethmoidal genu is a constant anatomical structure positioned within frontal sinus drainage pathway. The description of anterior ethmoidal genu found in this study explained the anatomical connection between the agger nasi cell, uncinate process and bulla ethmoidalis and its structural organisation.

    Matched MeSH terms: Tomography, X-Ray Computed/methods
  14. Soon LP, Subramaniam K, Madon NF, Mohamad Noor MH, Chainchel Singh MK, Mahmood MS
    Indian J Radiol Imaging, 2019 10 30;29(3):305-309.
    PMID: 31741600 DOI: 10.4103/ijri.IJRI_2_19
    Introduction: The aim of this study is to correlate urinary bladder distension and pulmonary edema on postmortem computed tomography (CT) scans with toxicology results in postmortem cases.

    Methods and Results: The study population was the postmortem cases of Asian population ranging from 16 to 75 years old in which blood and/or urine samples sent for alcohol and/or drug of abuse (DoA) analysis in year 2016 at our centre. Out of 434 cases, 54 from each group of positive and negative alcohol and/or DoA. Postmortem findings of lungs and postmortem CT scan urinary bladder volume (UBV) were recorded. Statistical significant correlation was obtained between urinary bladder distension on postmortem CT scan and cases with positive alcohol detection. However, the sensitivity was relatively low at 51.7%, whereas the specificity was 75% at the cut-off point. Low sensitivity and specificity at around 52.7% were obtained for pulmonary edema related to alcohol/DoA. This showed that UBV alone or pulmonary edema alone was not really a good indicator for alcohol or DoA intoxication. However, combination of both indicators provided higher sensitivity (73.3%) although specificity was lowered to 53.8%.

    Conclusion: The findings of postmortem CT scan bladder distension and pulmonary edema could possibly identify intoxication cases but not conclusive.

    Matched MeSH terms: Tomography; Tomography, X-Ray Computed
  15. Young Chuah Y, Yeh Lee Y
    Turk J Gastroenterol, 2023 Aug;34(8):890-891.
    PMID: 37434401 DOI: 10.5152/tjg.2023.23208
    Matched MeSH terms: Tomography, X-Ray Computed*
  16. Al-Siweedi SYA, Ngeow WC, Nambiar P, Abu-Hassan MI, Ahmad R, Asif MK, et al.
    Folia Morphol (Warsz), 2023;82(2):315-324.
    PMID: 35285511 DOI: 10.5603/FM.a2022.0024
    BACKGROUND: The purpose of this study was to identify and classify the anatomic variation of mandibular canal among Malaysians of three ethnicities.

    MATERIALS AND METHODS: The courses of the mandibular canal in 202 cone-beam computed tomography scanned images of healthy Malaysians were evaluated, and trifid mandibular canal (TMC) when present, were recorded and studied in detail by categorizing them to a new classification (comprising of 12 types). The diameter and length of canals were also measured, and their shape determined.

    RESULTS: Trifid mandibular canals were observed in 12 (5.9%) subjects or 16 (4.0%) hemi-mandibles. There were 10 obvious categories out the 12 types of TMCs listed. All TMCs (except one) were observed in patients older than 30 years. The prevalence according to ethnicity was 6 in Malays, 5 in Chinese and 1 in Indian. Four (33.3%) patients had bilateral TMCs, which was not seen in the Indian subject. More than half (56.3%) of the accessory canals were located above the main mandibular canal. Their mean diameter was 1.32 mm and 1.26 mm for the first and second accessory canal, and the corresponding lengths were 20.42 mm and 21.60 mm, respectively. Most (62.5%) canals had irregularly shaped lumen; there were more irregularly shaped canals in the second accessory canal than the first branch. None of the second accessory canal was oval (in shape).

    CONCLUSIONS: This new classification can be applied for the variations in the branching pattern, length and shape of TMCs for better clinical description.

    Matched MeSH terms: Cone-Beam Computed Tomography/methods
  17. Fijasri NH, Muhammad Asri NA, Mohd Shah MS, Abd Samad MR, Omar N
    Afr J Paediatr Surg, 2023;20(3):245-248.
    PMID: 37470566 DOI: 10.4103/ajps.AJPS_10_21
    Congenital pulmonary airway malformation (CPAM) together with oesophageal atresia and tracheoesophageal fistula (TOF) is a very rare condition in neonates. We presented a case of an infant with Gross type C oesophageal atresia with TOF coexisting with Stocker Type III CPAM in our centre. It is interesting to know that TOF associated with type III CPAM has never been reported in the literature. The child was delivered through caesarean section, and because of respiratory distress post-delivery, endotracheal intubation was carried out immediately. CPAM was diagnosed by a suspicious finding from the initial chest X-ray and the diagnosis was confirmed through computed tomography scan of the chest. The patient was initially stabilised in a neonatal intensive care unit (NICU), and after the successful ligation of fistula and surgical repair of TOF, lung recruitment was started by high flow oscillatory ventilation. The patient recovered well without complications and able to maintain good saturation without oxygen support through the stay in the neonatal unit. Early recognition of this rare association is essential for immediate transfer to NICU, the intervention of any early life-threatening complications, and for vigilant monitoring in the postoperative period.
    Matched MeSH terms: Tomography, X-Ray Computed/methods
  18. Ninomiya K, Arimura H, Tanaka K, Chan WY, Kabata Y, Mizuno S, et al.
    Comput Methods Programs Biomed, 2023 Jun;236:107544.
    PMID: 37148668 DOI: 10.1016/j.cmpb.2023.107544
    OBJECTIVES: To elucidate a novel radiogenomics approach using three-dimensional (3D) topologically invariant Betti numbers (BNs) for topological characterization of epidermal growth factor receptor (EGFR) Del19 and L858R mutation subtypes.

    METHODS: In total, 154 patients (wild-type EGFR, 72 patients; Del19 mutation, 45 patients; and L858R mutation, 37 patients) were retrospectively enrolled and randomly divided into 92 training and 62 test cases. Two support vector machine (SVM) models to distinguish between wild-type and mutant EGFR (mutation [M] classification) as well as between the Del19 and L858R subtypes (subtype [S] classification) were trained using 3DBN features. These features were computed from 3DBN maps by using histogram and texture analyses. The 3DBN maps were generated using computed tomography (CT) images based on the Čech complex constructed on sets of points in the images. These points were defined by coordinates of voxels with CT values higher than several threshold values. The M classification model was built using image features and demographic parameters of sex and smoking status. The SVM models were evaluated by determining their classification accuracies. The feasibility of the 3DBN model was compared with those of conventional radiomic models based on pseudo-3D BN (p3DBN), two-dimensional BN (2DBN), and CT and wavelet-decomposition (WD) images. The validation of the model was repeated with 100 times random sampling.

    RESULTS: The mean test accuracies for M classification with 3DBN, p3DBN, 2DBN, CT, and WD images were 0.810, 0.733, 0.838, 0.782, and 0.799, respectively. The mean test accuracies for S classification with 3DBN, p3DBN, 2DBN, CT, and WD images were 0.773, 0.694, 0.657, 0.581, and 0.696, respectively.

    CONCLUSION: 3DBN features, which showed a radiogenomic association with the characteristics of the EGFR Del19/L858R mutation subtypes, yielded higher accuracy for subtype classifications in comparison with conventional features.

    Matched MeSH terms: Tomography, X-Ray Computed/methods
  19. Usmani S, Al-Turkait D, Al-Kandari F, Ahmed N
    Clin Nucl Med, 2022 Jan 01;47(1):e43-e44.
    PMID: 34034312 DOI: 10.1097/RLU.0000000000003707
    18F-FDG PET/CT has been found useful for the detection of the source of infection/inflammation in the body. Platelet-rich plasma is a new treatment modality in which plasma is injected subdermally or intradermally for potential hair regrowth into the scalp. We report a case of 43-year-old woman with right breast cancer who underwent surgery, chemotherapy, and radiotherapy 2 years ago and is currently on hormonal therapy. 18F-FDG PET/CT demonstrate incidental findings of increased FDG avidity in the scalp after platelet-rich plasma therapy.
    Matched MeSH terms: Positron Emission Tomography Computed Tomography
  20. Hatipoğlu FP, Mağat G, Hatipoğlu Ö, Al-Khatib H, Elatrash AS, Abidin IZ, et al.
    J Endod, 2023 Oct;49(10):1308-1318.
    PMID: 37393948 DOI: 10.1016/j.joen.2023.06.011
    AIM: The aim of this study was two-folded: i) to assess the prevalence of Distolingual Canal (DLC) and Radix Entomolaris (RE) in Mandibular First Molars (M1Ms), using Cone Beam Computed Tomography (CBCT) images and ii) to assess the impact of sociodemographic factors on the prevalence of these conditions worldwide.

    METHODS: CBCT images were scanned retrospectively and the ones including bilateral M1Ms were included in the study. The evaluation was performed by 1 researcher in each country, trained with CBCT technology. A written and video instruction program explaining the protocol to be followed step-by-step was provided to all observers to calibrate them. The CBCT imaging screening procedure consisted of evaluating axial sections from coronal to apical. The presence of DLC and RE in M1Ms (yes/no) was identified and recorded.

    RESULTS: Six thousand three hundred four CBCTs, representing 12,608 M1Ms, were evaluated. A significant difference was found between countries regarding the prevalence of both RE and DLC (P  .05).

    CONCLUSION: The overall prevalence of RE and DLC in M1Ms was 3% and 22%. Additionally, both RE and DLC showed substantial bilaterally. These variations should be considered by endodontic clinicians during endodontic procedures in order to avoid potential complications.

    Matched MeSH terms: Cone-Beam Computed Tomography/methods