Displaying publications 101 - 120 of 212 in total

Abstract:
Sort:
  1. Tan SK, Ng KH, Yeong CH, Raja Aman RRA, Mohamed Sani F, Abdul Aziz YF, et al.
    Quant Imaging Med Surg, 2019 Apr;9(4):552-564.
    PMID: 31143647 DOI: 10.21037/qims.2019.03.13
    Background: High delivery rate is an important factor in optimizing contrast medium administration in coronary computed tomography angiography (CCTA). A personalized contrast volume calculation algorithm incorporating high iodine delivery rate (IDR) can reduce total iodine dose (TID) and produce optimal vessel contrast enhancement (VCE) in low tube voltage CCTA. In this study, we developed and validated an algorithm for calculating the volume of contrast medium delivered at a high rate for patients undergoing retrospectively ECG-gated CCTA with low tube voltage protocol.

    Methods: The algorithm for an IDR of 2.22 gI·s-1 was developed based on the relationship between VCE and contrast volume in 141 patients; test bolus parameters and characteristics in 75 patients; and, tube voltage in a phantom study. The algorithm was retrospectively tested in 45 patients who underwent retrospectively ECG-gated CCTA with a 100 kVp protocol. Image quality, TID and radiation dose exposure were compared with those produced using the 120 kVp and routine contrast protocols.

    Results: Age, sex, body surface area (BSA) and peak contrast enhancement (PCE) were significant predictors for VCE (P<0.05). A strong linear correlation was observed between VCE and contrast volume (r=0.97, P<0.05). The 100-to-120 kVp contrast enhancement conversion factor (Ec) was calculated at 0.81. Optimal VCE (250 to 450 HU) and diagnostic image quality were obtained with significant reductions in TID (32.1%) and radiation dose (38.5%) when using 100 kVp and personalized contrast volume calculation algorithm compared with 120 kVp and routine contrast protocols (P<0.05).

    Conclusions: The proposed algorithm could significantly reduce TID and radiation exposure while maintaining optimal VCE and image quality in CCTA with 100 kVp protocol.

    Matched MeSH terms: Electrocardiography
  2. Manogaran G, Shakeel PM, Fouad H, Nam Y, Baskar S, Chilamkurti N, et al.
    Sensors (Basel), 2019 Jul 09;19(13).
    PMID: 31324070 DOI: 10.3390/s19133030
    According to the survey on various health centres, smart log-based multi access physical monitoring system determines the health conditions of humans and their associated problems present in their lifestyle. At present, deficiency in significant nutrients leads to deterioration of organs, which creates various health problems, particularly for infants, children, and adults. Due to the importance of a multi access physical monitoring system, children and adolescents' physical activities should be continuously monitored for eliminating difficulties in their life using a smart environment system. Nowadays, in real-time necessity on multi access physical monitoring systems, information requirements and the effective diagnosis of health condition is the challenging task in practice. In this research, wearable smart-log patch with Internet of Things (IoT) sensors has been designed and developed with multimedia technology. Further, the data computation in that smart-log patch has been analysed using edge computing on Bayesian deep learning network (EC-BDLN), which helps to infer and identify various physical data collected from the humans in an accurate manner to monitor their physical activities. Then, the efficiency of this wearable IoT system with multimedia technology is evaluated using experimental results and discussed in terms of accuracy, efficiency, mean residual error, delay, and less energy consumption. This state-of-the-art smart-log patch is considered as one of evolutionary research in health checking of multi access physical monitoring systems with multimedia technology.
    Matched MeSH terms: Electrocardiography
  3. Oon YY, Koh KT, Khaw CS, Mohd Amin NH, Ong TK
    Med J Malaysia, 2019 08;74(4):328-330.
    PMID: 31424042
    Arrhythmogenic right ventricular cardiomyopathy (ARVC) is primarily a familial disease with autosomal dominant inheritance. Incomplete penetrance and variable expression are common, resulting in broad disease spectrum. Three patterns of phenotypic expression have been described: (1) "classic" subtype, with predominant right ventricle involvement, (2) "left dominant" subtype, with early and dominant left ventricle involvement, and (3) "biventricular" subtype, with both ventricles equally affected. Genotypephenotype associations have been described, but there are other genetic and non-genetic factors that can affect disease expression. We describe two different phenotypic expressions of ARVC in a family.
    Matched MeSH terms: Electrocardiography
  4. Faust O, Razaghi H, Barika R, Ciaccio EJ, Acharya UR
    Comput Methods Programs Biomed, 2019 Jul;176:81-91.
    PMID: 31200914 DOI: 10.1016/j.cmpb.2019.04.032
    BACKGROUND AND OBJECTIVE: Sleep is an important part of our life. That importance is highlighted by the multitude of health problems which result from sleep disorders. Detecting these sleep disorders requires an accurate interpretation of physiological signals. Prerequisite for this interpretation is an understanding of the way in which sleep stage changes manifest themselves in the signal waveform. With that understanding it is possible to build automated sleep stage scoring systems. Apart from their practical relevance for automating sleep disorder diagnosis, these systems provide a good indication of the amount of sleep stage related information communicated by a specific physiological signal.

    METHODS: This article provides a comprehensive review of automated sleep stage scoring systems, which were created since the year 2000. The systems were developed for Electrocardiogram (ECG), Electroencephalogram (EEG), Electrooculogram (EOG), and a combination of signals.

    RESULTS: Our review shows that all of these signals contain information for sleep stage scoring.

    CONCLUSIONS: The result is important, because it allows us to shift our research focus away from information extraction methods to systemic improvements, such as patient comfort, redundancy, safety and cost.

    Matched MeSH terms: Electrocardiography
  5. Khor KH, Chin MX
    J Adv Vet Anim Res, 2020 Sep;7(3):501-508.
    PMID: 33005676 DOI: 10.5455/javar.2020.g446
    Objective: Annual health screening inclusive of heart workup is recommended for the detection of heart diseases, especially in asymptomatic patients (no clinical signs). This study determined the occurrences of the common heart disease and the risk factors in apparently healthy cats.

    Materials and methods: This prospective study that screened 59 healthy cats and the status of the heart were evaluated based on a combination of findings from physical examination, electrocardiography, blood pressure measurement, routine blood test, urinalysis, and total thyroid level.

    Results: Approximately 40.7% (n = 24/59) of the apparently healthy cats were diagnosed with heart disease hypertrophic cardiomyopathy (62.5%) remains to be the most commonly diagnosed. The mean age was 4.9-year old (age range, 7-month-old to 19-year-old). The prevalence was higher in males (45.0%; n = 17/38) cats, especially the domestic shorthairs (46.0%; n = 11/24). Among the healthy cats with vertebral heart scale (VHS) > 8.0, only 52% (n = 12/23) of them were diagnosed with cardiomyopathy. However, 33% (n = 12/36) of the cats with normal VHS ≤ 7.9 were diagnosed with heart disease. Consistently, all healthy cats with abnormal heart sounds were diagnosed with heart disease. About 31.4% (n = 16/51) of these cats with typical heart sound had cardiomyopathy too.

    Conclusion: The occurrence of cardiomyopathy in apparently healthy cats has no association with the patient's age, sex, and VHS, except for the heart sound. Echocardiography remains the best diagnostic tool, as normal heart size and normal heart sound do not exclude cardiomyopathy in this group of apparently healthy cats.

    Matched MeSH terms: Electrocardiography
  6. Loong CW, Firdaus MAM, Said MRM, Abidin IZ
    Medeni Med J, 2020;35(3):266-270.
    PMID: 33110680 DOI: 10.5222/MMJ.2020.47374
    Takotsubo syndrome is a rare disease and remained ambiguous with its etiology. The disease manifests in various clinical characteristics and even mimicking acute coronary syndrome. We are reporting a case of an elderly lady who manifested by unsteady gaits and recurrent falls. Subacute infarct of the right corona radiata was observed on the brain CT. In addition, coronary angiography and ventriculogram were performed because of dynamic ECG changes and elevated troponin I levels. The angiogram was normal while ventriculogram showed apical ballooning. She was diagnosed and treated as Takotsubo syndrome.
    Matched MeSH terms: Electrocardiography
  7. Ohn MH, Ohn KM
    Ci Ji Yi Xue Za Zhi, 2019 06 06;32(2):211-215.
    PMID: 32269957 DOI: 10.4103/tcmj.tcmj_5_19
    Objective: The successful application of gamification in different educational settings shows that the use of gamification in medical education may be an effective solution. Even though many studies have been conducted to investigate the efficacy of the integration of gamification to different education curriculums, few studies have examined the reactions, behaviors, and attitudes of learners toward the use of gamification in medical education. Hence, this study aimed to evaluate the medical students' learning experience and acceptance of the use of gamification for the delivery of electrocardiogram lessons.

    Materials and Methods: A qualitative research method was used to generate findings in this study. The data collection methods included focus group discussions and interviews. Triangulation methods were used to ensure the validity and reliability of the qualitative data analyzed in this study. The thematic analysis of the data collected in this study helped to garner insights into the perception of participants and experts about the use of GaMed@™ for the delivery of ECG lessons.

    Results: A total number of 32 medical students and four experts in the fields of user experience, communication, social psychology, and game design participated in this study. The findings showed that in spite of the negative reports about the user experience and application of GaMed@™, the participants and experts affirmed its positive impact on the increased motivation and engagement of users.

    Conclusions: The impact of this concept can be maximized by tailoring the game design to foster-positive learning attributes, behaviors, and outcomes in students. However, further research studies must be conducted to investigate the impact of gamification designs on specific learning outcomes in students.

    Matched MeSH terms: Electrocardiography
  8. Lan BL, Liew YW, Toda M, Kamsani SH
    Chaos, 2020 May;30(5):053137.
    PMID: 32491883 DOI: 10.1063/1.5130524
    Complex dynamical systems can shift abruptly from a stable state to an alternative stable state at a tipping point. Before the critical transition, the system either slows down in its recovery rate or flickers between the basins of attraction of the alternative stable states. Whether the heart critically slows down or flickers before it transitions into and out of paroxysmal atrial fibrillation (PAF) is still an open question. To address this issue, we propose a novel definition of cardiac states based on beat-to-beat (RR) interval fluctuations derived from electrocardiogram data. Our results show the cardiac state flickers before PAF onset and termination. Prior to onset, flickering is due to a "tug-of-war" between the sinus node (the natural pacemaker) and atrial ectopic focus/foci (abnormal pacemakers), or the pacing by the latter interspersed among the pacing by the former. It may also be due to an abnormal autonomic modulation of the sinus node. This abnormal modulation may be the sole cause of flickering prior to termination since atrial ectopic beats are absent. Flickering of the cardiac state could potentially be used as part of an early warning or screening system for PAF and guide the development of new methods to prevent or terminate PAF. The method we have developed to define system states and use them to detect flickering can be adapted to study critical transition in other complex systems.
    Matched MeSH terms: Electrocardiography
  9. Wong, Jackson Sing Ann, Yew, Hoe Tung
    MyJurnal
    In this modern and fast-moving world, elderly’s safety and security have become an important issue. According to the World Population Prospects of the United Nations 2015, there is 12.3 per cent population aged 60 and above globally and it is the fastest growing population at a rate of 3.26 per cent per year. In order to reduce the worries about the elderly living alone at home, Elderly Monitoring System is required for continuous monitoring. “Fall†is one of the critical incidents for the elderly living alone as it causes serious injuries. A fall detection system using global system for mobile communication can help to reduce the time of unaware of their next of kin.
    Matched MeSH terms: Electrocardiography
  10. Ming Fung Ng, Hoe Tung Yew, Seng Kheau Chung, Syed Shajee Husain, Nelbon Giloi
    MyJurnal
    Introduction: Cardiovascular diseases remain as the principal cause of death in Malaysia. The rural areas in Sabah still suffer from shortage of doctors and specialists. Health Indicators 2018 from Ministry of Health Malaysia shows the ratio of doctor to population in Sabah is 1:1029. The lack of specialist care for the rural population is a major concern. To overcome the barrier of healthcare services, deployment of telecardiology system is necessary. The objective of this project is to develop a real-time telecardiology system that can transmit and guarantee the quality of the ECG signal. Methods: The proposed real-time telecardiology system used an ECG sensor AD8232 to collect the ECG signal. Arduino ESP32 as a main controller of the system. It uploads the collected ECG data to the online database in real-time through Wi-Fi or cellular network with MQTT protocol. A website is developed for displaying the real-time ECG signal. Results: The proposed system has successfully displayed the ECG signal in real-time with 10000 ECG raw data were tested and stored in online database with no package loss and package error during the data transmission. The online system able to display real-time ECG signal and BPM on webpage. The real-time BPM is extracted from the real-time ECG raw data. Conclusion: The proposed real-time telecardiology system has success-fully transmitted ECG in real-time with high data integrity. Telecardiology is one of the best solutions to resolve the issue of shortage of healthcare professionals in rural areas and improve the healthcare quality in rural areas.
    Matched MeSH terms: Electrocardiography
  11. Neesha Sundramoorthy, Khaiteri R., Jer Ming Low, Chan Soon Thim Darren
    MyJurnal
    Introduction: Artemether and lumefantrine was registered as Riamet in Switzerland in 1999 and is commonly used in Keningau Hospital for managing uncomplicated malaria. Riamet works at the food vacoule of the malarial parasite, where they interfere with the conversion of heme into haemozoin. Case description: We report a case of Riamet induced prolonged corrected QT interval (QTc) in a 37 year old gentleman admitted for severe malaria (hypotension) with normal QTc of 420msc on presentation. Upon starting Riamet, he developed bradycardia and ECG showed sinus bradycardia with prolonged QTc of 551msec and no arrythmias. Echocardiography showed no structural heart abnormalities. All electrolytes were within normal range. He was monitored in cardiac care unit with decision to complete 6 doses of Riamet. Patient was started on Dopamine infusion which maintained his blood pressure and heart rate within normal range. 5 days post Riamet completion, his heart rate improved and dopamine infusion was tapered off and QTc normalized to 407msc. Discussion: The most common mechanism of drugs causing QT inter-val prolongation is by blocking the human ether-à-go-go related gene (hERG) potassium channel. Blockage of the hEGR channel lengthens ventricular re-polarization and duration of ventricular action potential which is reflected in ECG as prolonged QT interval. In the in-vitro whole cell patch clamp study, lumefantrine and its metabolite desbu-tyl-lumefantrine showed a concentration-dependent inhibition of the hERG current. The period of QTc prolongation was 3.5 to 4 days after the last dose of the standard 6 dose regimen. Conclusion: Riamet induced prolonged QTc is a very rare complication. A baseline electrocardiography is therefore imminent for every patient prior to initiation of this medication to avoid cardiac arrythmias.
    Matched MeSH terms: Electrocardiography
  12. Ahmed AZ, Satyam SM, Shetty P, D'Souza MR
    Scientifica (Cairo), 2021;2021:6694340.
    PMID: 33510932 DOI: 10.1155/2021/6694340
    Doxorubicin-induced cardiotoxicity is the leading cause of morbidity and mortality among cancer survivors. The present study was aimed to investigate the cardioprotective potential of methyl gallate; an active polyphenolic nutraceutical, against doxorubicin-induced cardiotoxicity in Wistar rats. Twenty-four female Wistar rats (150-200 g) were divided into four groups (n = 6) which consist of normal control (group I), doxorubicin control (group II), test-A (group III), and test-B (group IV). Group III and group IV animals were prophylactically treated with methyl gallate 150 mg/kg/day and 300 mg/kg/day orally, respectively, for seven days. Doxorubicin (25 mg/kg; single dose) was administered through an intraperitoneal route to group II, III, and IV animals on the seventh day to induce acute cardiotoxicity. On the 8th day, besides ECG analysis, serum CK, CK-MB, LDH, AST, MDA, and GSH were assayed. Following gross examination of isolated hearts, histopathological evaluation was performed by light microscopy. A significant (p 
    Matched MeSH terms: Electrocardiography
  13. Krishnan GD, Yahaya N, Yahya M
    J ASEAN Fed Endocr Soc, 2019;34(1):92-94.
    PMID: 33442142 DOI: 10.15605/jafes.034.01.14
    A 31-year-old male, apparently well, presented with typical chest pain. His ECG showed ST-elevation from V1-V4 and echocardiogram revealed anteroseptal wall hypokinesia with ejection fraction of 45%. Normal coronary arteries were seen on coronary angiogram. A thyroid function test showed elevated free T4 levels with suppressed thyroid stimulating hormone (TSH). Treatment with thionamides and beta-blockers improved symptoms. Upon review 4 months later he was well. Repeat echocardiogram showed good ejection fraction with no hypokinetic area.
    Matched MeSH terms: Electrocardiography
  14. Aung T
    Med J Malaysia, 1997 Dec;52(4):441-3.
    PMID: 10968125
    A case of unsuspected penetrating cardiac injury is presented. It was recognised by the presence of bleeding into peritoneal cavity even after the source of bleeding from intra-abdominal organs had been stopped. It highlights the importance of high index of suspicion of associated cardiac injury in high epigastric penetrating injury.
    Matched MeSH terms: Electrocardiography
  15. Ong HT
    Med J Malaysia, 1991 Dec;46(4):379-83.
    PMID: 1840450
    A 61-year old lady presented clinically in unstable angina with ST-segment depression typical of myocardial ischemia. However, coronary arteries were completely normal at angiography. Exercise testing reproduced symptoms and ST-segment depression. A diagnosis of Syndrome X was made, an uncommon disorder of myocardial ischemia with normal coronary anatomy and excellent prognosis.
    Matched MeSH terms: Electrocardiography
  16. Ong PK, Ramanathan M
    Med J Malaysia, 1987 Sep;42(3):215-6.
    PMID: 3506649
    We report a case of transient complete heart block with Stokes-Adams attack due to acute rheumatic fever. The patient was a 12-year old boy whose illness satisfied the criteria of acute rheumatic fever. A temporary transvenous cardiac pacer was necessary to tide him over the complete heart block. The rarity of this complication of acute rheumatic fever is highlighted.
    Matched MeSH terms: Electrocardiography
  17. Jeyamalar R, Pathmanathan R, Yap SF, Kannan P
    Ann Acad Med Singap, 1991 Nov;20(6):795-7.
    PMID: 1803972
    Cardiac amyloidosis is an uncommon and often unrecognised cause of cardiac failure. It is an infiltrative disease that may mimic either a restrictive or hypertrophic cardiomyopathy, constrictive pericarditis, coronary artery disease or valvular heart disease. The diagnosis should be suspected in a patient with cardiac failure who has low voltage complexes on the electrocardiogram, in association with increased myocardial mass and echogenicity on the echocardiogram. The definitive diagnosis, however, can only be made by endomyocardial biopsy or biopsy of any involved organ in systemic amyloidosis. Prognosis is poor and treatment ineffective.
    Matched MeSH terms: Electrocardiography
  18. Sufarlan AW, Khalid BA
    Med J Malaysia, 1989 Dec;44(4):334-40.
    PMID: 2520044
    Four cases of acute viral myocarditis were diagnosed within three weeks. The clinical features, electrocardiography, cardiac enzymes and other laboratory investigations are described.
    Matched MeSH terms: Electrocardiography
  19. Gururaj AK, Ainon S
    J Singapore Paediatr Soc, 1990;32(1-2):50-2.
    PMID: 2259197
    It is well known that episodic loss of consciousness and convulsions may have a cardiac rather than a cerebral origin (1). We report a case where these episodes were caused by recurrent ventricular tachycardia/ventricular fibrillation secondary to idiopathic long QT syndrome which was effectively treated with amiodarone.
    Matched MeSH terms: Electrocardiography
  20. Anuar M, Singham KT
    Med J Malaysia, 1979 Dec;34(2):140-4.
    PMID: 548715
    Matched MeSH terms: Electrocardiography
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links