METHOD: English language literature in major databases from the last 20 years was searched using controlled vocabulary and keywords. Strict inclusion and exclusion criteria were followed for selection of studies. The quality assessment was done as per the QUADAS tool 2 by three independent reviewers. The metanalysis was performed by using random effect model. Standardized mean difference (SMD) was considered as the effect measure. Statistical software used was STATA version 13.1.
RESULTS: With all inclusion and exclusion criteria, eight studies could qualify for metanalysis. The pooled estimate is found to be 0.13 (-0.35, 0.62), P = .585, which is statistically not significant. This indicates that there is a no significant difference in the fold change between metastasis and no metastasis groups. P-value of chi-square statistic for heterogeneity is
PURPOSE: The purpose of this finite element analysis study was to evaluate the biomechanical behavior (stress distribution pattern) in the mandibular overdenture, mucosa, bone, and implants when retained with 2 standard implants or 2 mini implants under unilateral or bilateral loading conditions.
MATERIAL AND METHODS: A patient with edentulous mandible and his denture was scanned with cone beam computed tomography (CBCT), and a 3D mandibular model was created in the Mimics software program by using the CBCT digital imaging and communications in medicine (DICOM) images. The model was transferred to the 3Matics software program to form a 2-mm-thick mucosal layer and to assemble the denture DICOM file. A 12-mm-long standard implant (Ø3.5 mm) and a mini dental implant (Ø2.5 mm) along with the LOCATOR male attachments (height 4 mm) were designed by using the SOLIDWORKS software program. Two standard or 2 mini implants in the canine region were embedded separately in the 3D assembled model. The base of the mandible was fixed, and vertical compressive loads of 100 N were applied unilaterally and bilaterally in the first molar region. The material properties for acrylic resin (denture), titanium (implants), mucosa (tissue), and bone (mandible) were allocated. Maximum von Mises stress and strain values were obtained and analyzed.
RESULTS: Maximum stresses of 9.78 MPa (bilaterally) and 11.98 MPa (unilaterally) were observed in 2 mini implants as compared with 3.12 MPa (bilaterally) and 3.81 MPa (unilaterally) in 2 standard implants. The stress values in the mandible were observed to be almost double the mini implants as compared with the standard implants. The stresses in the denture were in the range of 3.21 MPa and 3.83 MPa and in the mucosa of 0.68 MPa and 0.7 MPa for 2 implants under unilateral and bilateral loading conditions. The strain values shown similar trends with both implant types under bilateral and unilateral loading.
CONCLUSIONS: Two mini implants generated an average of 68.15% more stress than standard implants. The 2 standard implant-retained overdenture showed less stress concentration in and around implants than mini implant-retained overdentures.
Material and method: This study surveyed 303 orthopaedic surgeons from all over Pakistan. The survey had 30 questions targeting the setup of outpatient, emergency and operation services in orthopaedic departments of different hospitals in Pakistan.
Result: A total of 302 surgeons were included from 53 cities all over Pakistan. Between 35-48% of the respondents reported lack of availability of standard operating procedures in OPD, ER and in OT. Majority of the respondents noted that their OPD and surgical practice had been affected to some degree and 69% of the surgeons were only doing trauma surgery. This trend was higher in younger consultants of less than 45 years of age (p<0.001). Almost two-third of the surgeons, mostly senior (p=0.03) were using surgical masks as the only protective measure during various practices of OPD, ER and OT, while most of the setups were not assessing patients even for signs and symptoms of COVID. Almost 89% of the orthopaedic community is facing definite to mild stress during this pandemic and this has significantly affected the senior surgeons (p=0.01).
Conclusion: Our study highlighted that COVID-19 has resulted in marked changes to the practices of the majority of Pakistani orthopaedic surgeons. Despite a sharp upsurge in the number of cases and mortality due to COVID-19, guidelines were still lacking at most of the settings and a substantial percentage of the orthopaedic community were not following adequate safety measures while attending to patients.
Material and methods: The extracortical bone bridge interface's radiological parameter was evaluated at the prosthesis bone junction two years after surgery utilising a picture archiving and communication system (PACS). The radiograph's anteroposterior and lateral view was analysed for both thickness and length in all four cortices. The analysis was done in SPSS Version 24 using One-Way ANOVA and independent T-Test. Results were presented as mean and standard deviation and considered significant when the p-value was < 0.05.
Results: The mean average thickness was 2.2293mm (SD 1.829), and the mean average length was 31.95% (SD 24.55). We observed that the thickness and length of EBBI were superior in the young patient or patients with giant cell tumour that did not receive chemotherapy, compared to patients treated for osteosarcoma. The distal femur also had better EBBI compared to the proximal tibia. However, the final multivariable statistical analysis showed no significant difference in all variables. EBBI thickness was significantly and positively correlated with EBBI Length (p<0.001). We conclude that, for each 1mm increase in EBBI thickness, the length will increase by 0.06% on average. About 17.2% of patients out of the 29 showed no radiological evidence of EBBI.
Conclusion: From our study, there were no factors that significantly contributed to the formation and incorporation of EBBI.
AIM: To evaluate the preferred diagnosis and management practices of BE among Asian endoscopists.
METHODS: Endoscopists from across Asia were invited to participate in an online questionnaire comprising eleven questions regarding diagnosis, surveillance and management of BE.
RESULTS: Five hundred sixty-nine of 1016 (56.0%) respondents completed the survey, with most respondents from Japan (n = 310, 54.5%) and China (n = 129, 22.7%). Overall, the preferred endoscopic landmark of the esophagogastric junction was squamo-columnar junction (42.0%). Distal palisade vessels was preferred in Japan (59.0% vs 10.0%, P < 0.001) while outside Japan, squamo-columnar junction was preferred (59.5% vs 27.4%, P < 0.001). Only 16.3% of respondents used Prague C and M criteria all the time. It was never used by 46.1% of Japanese, whereas 84.2% outside Japan, endoscopists used it to varying extents (P < 0.001). Most Asian endoscopists (70.8%) would survey long-segment BE without dysplasia every two years. Adherence to Seattle protocol was poor with only 6.3% always performing it. 73.2% of Japanese never did it, compared to 19.3% outside Japan (P < 0.001). The most preferred (74.0%) treatment of non-dysplastic BE was proton pump inhibitor only when the patient was symptomatic or had esophagitis. For BE with low-grade dysplasia, 6-monthly surveillance was preferred in 61.9% within Japan vs 47.9% outside Japan (P < 0.001).
CONCLUSION: Diagnosis and management of BE varied within Asia, with stark contrast between Japan and outside Japan. Most Asian endoscopists chose squamo-columnar junction to be the landmark for esophagogastric junction, which is incorrect. Most also did not consistently use Prague criteria, and Seattle protocol. Lack of standardization, education and research are possible reasons.
METHODS: This is a prospective block randomized, non-blinded study conducted at a single tertiary hospital. Patients undergoing elective laparoscopic cholecystectomy between August 2017 and October 2018 were recruited and randomized into Handout Assisted Consent (HC) and Verbal Consent (VC) group. The HC group was given an adjunct handout on laparoscopic cholecystectomy during consent process in addition to the standard verbal consent. A validated open-ended verbal understanding and recall questionnaire was administered to all patients in both groups at Day 1, 30 and 90 after surgery. Patient satisfaction of the consent process was evaluated with Likert scale.
RESULTS: A total of 79 patients were enrolled, 41 patients and 38 patients in VC and HC groups respectively. Level of understanding among patients were equal and consistent across time in both groups (P > 0.05). There was significant decline (P 0.05).
CONCLUSION: There is good consistent understanding of the surgery in both groups. However, recall of specific surgical consent items decreased significantly over time in both groups. Handouts may have increased satisfaction among patients but did not improve recall in this preliminary study.
TRIAL REGISTRATION: MREC No.:201783-5468.
Methods: We searched the Cochrane Central Register of Controlled Trials, MEDLINE and Epistemonikos for all randomized control trials (RCTs) comparing oral IPC with standard oral iron supplementation for the treatment or prevention of IDA in children. We independently screened the titles and abstracts of identified trials before the full text of relevant trials was evaluated for eligibility. We then independently extracted data on the methods, interventions, outcomes, and risk of bias from the included trials. A random-effects model was used to estimate the risk ratios and mean differences with 95% confidence intervals.
Results: Eight trials comprising 493 randomized patients were included and analyzed using three comparison groups. The comparison group of which was used to evaluate IPC and ferrous sulphate (FS) for treatment of IDA showed that IPC is less effective in increasing Hb (MD -0.81, 95% CI -1.08 to -0.53; I2 = 48%, P