METHODS: Plasma from children and adults with P. vivax malaria in Sabah, Malaysia, were collected during acute infection, 7 and 28 days after drug treatment. Complement-fixing antibodies and immunoglobulin M and G (IgM and IgG), targeting 3 distinctive regions of PvMSP3α, were measured by means of enzyme-linked immunosorbent assay.
RESULTS: The seroprevalence of complement-fixing antibodies was highest against the PvMSP3α central region (77.6%). IgG1, IgG3, and IgM were significantly correlated with C1q fixation, and both purified IgG and IgM were capable of mediating C1q fixation to PvMSP3α. Complement-fixing antibody levels were similar between age groups, but IgM was predominant in children and IgG3 more prevalent in adults. Levels of functional antibodies increased after acute infection through 7 days after treatment but rapidly waned by day 28.
CONCLUSION: Our study demonstrates that PvMSP3α antibodies acquired during P. vivax infection can mediate complement fixation and shows the important influence of age in shaping these specific antibody responses. Further studies are warranted to understand the role of these functional antibodies in protective immunity against P. vivax malaria.
METHODS: An indirect enzyme-linked immunosorbent assay (ELISA) was developed to evaluate the usefulness of USM.TOXO1 antigen for the detection of IgG antibodies against Toxoplasma gondii in human sera. Whereas the reactivity of the developed antigen against IgM antibody was evaluated by western blot and Dot enzyme immunoassay (dot-EIA) analysis.
RESULTS: The diagnostic performance of the new antigens in IgG ELISA was achieved at the maximum values of 85.43% and 81.25% for diagnostic sensitivity and specificity respectively. The USM.TOXO1 was also proven to be reactive with anti- T. gondii IgM antibody.
CONCLUSIONS: This finding makes the USM.TOXO1 antigen an attractive candidate for improving the toxoplasmosis serodiagnosis and demonstrates that multiepitope antigens could be a potential and promising diagnostic marker for the development of high sensitive and accurate assays.
METHODS: This prospective cross-sectional study consecutively recruited 494 patients with suspected dengue from a health clinic in Malaysia. Both RDTs were performed onsite. The evaluated ELISA and reference tests were performed in a virology laboratory. The reference tests comprised of a reverse transcription-polymerase chain reaction and three ELISAs for the detection of dengue NS1 antigen, IgM and IgG antibodies, respectively. The diagnostic performance of evaluated tests was computed using STATA version 12.
RESULTS: The sensitivity and specificity of ViroTrack were 62.3% (95%CI 55.6-68.7) and 95.0% (95%CI 91.7-97.3), versus 66.5% (95%CI 60.0-72.6) and 95.4% (95%CI 92.1-97.6) for SD NS1 ELISA, and 52.4% (95%CI 45.7-59.1) and 97.7% (95%CI 95.1-99.2) for NS1 component of SD Bioline, respectively. The combination of the latter with its IgM and IgG components were able to increase test sensitivity to 82.4% (95%CI 76.8-87.1) with corresponding decrease in specificity to 87.4% (95%CI 82.8-91.2). Although a positive test on any of the NS1 assays would increase the probability of dengue to above 90% in a patient, a negative result would only reduce this probability to 23.0-29.3%. In contrast, this probability of false negative diagnosis would be further reduced to 14.7% (95%CI 11.4-18.6) if SD Bioline NS1/IgM/IgG combo was negative.
CONCLUSIONS: The performance of ViroTrack Dengue Acute was comparable to SD Dengue NS1 Ag ELISA. Addition of serology components to SD Bioline Dengue Duo significantly improved its sensitivity and reduced its false negative rate such that it missed the fewest dengue patients, making it a better point-of-care diagnostic tool. New RDT like ViroTrack Dengue Acute may be a potential alternative to existing RDT if its combination with serology components is proven better in future studies.
METHODS: In this study undertaken between April and May 2015, a total of 277 adult participants were recruited from households across three localities in the Sungai Segamat subdistrict in Segamat district. Sera were tested for immunoglobulin G (IgG) (Panbio® Dengue Indirect IgG ELISA/high-titer capture) and immunoglobulin M (IgM) (Panbio®) antibodies. The plaque reduction neutralization test (PRNT) was conducted on random samples of IgG-positive sera for further confirmation. Medical history and a recall of previous history of dengue were collected through interviews, whereas sociodemographic information was obtained from an existing database.
RESULTS: The overall seroprevalence for DENV infection was 86.6% (240/277) (95% CI: 83-91%). Serological evidence of recent infection (IgM/high-titer capture IgG) was noted in 11.2% (31/277) of participants, whereas there was evidence of past infection in 75.5% (209/277) of participants (indirect IgG minus recent infections). The PRNT assay showed that the detected antibodies were indeed specific to DENV. The multivariate analysis showed that the older age group was significantly associated with past DENV infections. Seropositivity increased with age; 48.5% in the age group of <25 years to more than 85% in age group of >45 years (P
METHODS: Recombinant PPDK (rPPDK) was expressed, purified and evaluated by Western blot. In parallel, recombinant galactose-and-N-acetyl-D-galactosamine inhibitable lectin (Gal/GalNAc lectin) was produced and tested similarly. The protein identity was confirmed by analysis using MALDI-TOF/TOF. A lateral flow dipstick (LFD) test using rPPDK was subsequently developed (rPPDK-LFD) and evaluated for serodiagnosis of ALA.
RESULTS: rPPDK was expressed as soluble protein after 4 hours of induction with 1 mM isopropyl β-D-1-thiogalactopyranoside (IPTG) at 30°C. Purification using nickel-nitrilotriacetic acid (Ni-NTA) resin yielded 1.5 mg of rPPDK from 1 L of culture with estimated molecular mass of 98 kDa on SDS-PAGE. Western blots using sera from patients with ALA, healthy individuals and other diseases probed with anti-human IgG4-HRP showed the highest sensitivity (93.3%) and specificity (100%); as compared to blots using IgG and IgG1 as secondary antibodies. Moreover, rPPDK showed better specificity when compared to rGal/GalNAc lectin. In the development of the LFD test, the optimum amount of rPPDK was 0.625 μg per dipstick and the optimum working concentration of colloidal gold conjugated anti-human IgG4 was optical density (OD) 5 (1.7 μg of anti-human IgG4). Evaluation of rPPDK-LFD using ALA patients and controls serum samples showed 87% diagnostic sensitivity and 100% specificity.
CONCLUSION: The developed rPPDK-LFD showed good potential for rapid diagnosis of ALA, and merit further multicentre validation using larger number of serum samples.