Displaying publications 141 - 160 of 169 in total

Abstract:
Sort:
  1. Ramli N, Rahmat K, Tan GP
    Singapore Med J, 2008 Jul;49(7):e175-7.
    PMID: 18695851
    Malignant osteopetrosis is associated with petrous carotid canal and internal carotid artery stenosis in the skull base. We present a four-year-old boy with malignant osteopetrosis who developed right frontal lobe infarction as a result of bilateral internal carotid artery hypotrophy.
    Matched MeSH terms: Imaging, Three-Dimensional
  2. Syed Mohd Hamdan SN, Rahmat RA, Abdul Razak F, Abd Kadir KA, Mohd Faizal Abdullah ER, Ibrahim N
    Leg Med (Tokyo), 2023 Sep;64:102275.
    PMID: 37229938 DOI: 10.1016/j.legalmed.2023.102275
    Sex estimation is crucial in biological profiling of skeletal human remains. Methods used for sex estimation in adults are less effective for sub-adults due to varied cranium patterns during the growth period. Hence, this study aimed to develop a sex estimation model for Malaysian sub-adults using craniometric measurements obtained through multi-slice computed tomography (MSCT). A total of 521 cranial MSCT dataset of sub-adult Malaysians (279 males, 242 females; 0-20 years old) were collected. Mimics software version 21.0 (Materialise, Leuven, Belgium) was used to construct three-dimensional (3D) models. A plane-to-plane (PTP) protocol was utilised to measure 14 selected craniometric parameters. Discriminant function analysis (DFA) and binary logistic regression (BLR) were used to statistically analyze the data. In this study, low level of sexual dimorphism was observed in cranium below 6 years old. The level was then increased with age. For sample validation data, the accuracy of DFA and BLR in estimating sex improved with age from 61.6% to 90.3%. All age groups except 0-2 and 3-6 showed high accuracy percentage (≥75%) when tested using DFA and BLR. DFA and BLR can be utilised to estimate sex for Malaysian sub-adult using MSCT craniometric measurements. However, BLR showed higher accuracy than DFA in sex estimation of sub-adults.
    Matched MeSH terms: Imaging, Three-Dimensional
  3. Azizan NA, Basaruddin KS, Salleh AF, Sulaiman AR, Safar MJA, Rusli WMR
    J Healthc Eng, 2018;2018:7815451.
    PMID: 29983905 DOI: 10.1155/2018/7815451
    Balance in the human body's movement is generally associated with different synergistic pathologies. The trunk is supported by one's leg most of the time when walking. A person with poor balance may face limitation when performing their physical activities on a daily basis, and they may be more prone to having risk of fall. The ground reaction forces (GRFs), centre of pressure (COP), and centre of mass (COM) in quite standing posture were often measured for the evaluation of balance. Currently, there is still no experimental evidence or study on leg length discrepancy (LLD) during walking. Analysis of the stability parameters is more representative of the functional activity undergone by the person who has a LLD. Therefore, this study hopes to shed new light on the effects of LLD on the dynamic stability associated with VGRF, COP, and COM during walking. Eighteen healthy subjects were selected among the university population with normal BMIs. Each subject was asked to walk with 1.0 to 2.0 ms-1 of walking speed for three to five trials each. Insoles of 0.5 cm thickness were added, and the thickness of the insoles was subsequently raised until 4 cm and placed under the right foot as we simulated LLD. The captured data obtained from a force plate and motion analysis present Peak VGRF (single-leg stance) and WD (double-leg stance) that showed more forces exerted on the short leg rather than long leg. Obviously, changes occurred on the displacement of COM trajectories in the ML and vertical directions as LLD increased at the whole gait cycle. Displacement of COP trajectories demonstrated that more distribution was on the short leg rather than on the long leg. The root mean square (RMS) of COP-COM distance showed, obviously, changes only in ML direction with the value at 3 cm and 3.5 cm. The cutoff value via receiver operating characteristic (ROC) indicates the significant differences starting at the level 2.5 cm up to 4 cm in long and short legs for both AP and ML directions. The present study performed included all the proposed parameters on the effect of dynamic stability on LLD during walking and thus helps to determine and evaluate the balance pattern.
    Matched MeSH terms: Imaging, Three-Dimensional
  4. Zreaqat M, Hassan R, Halim AS
    Int J Oral Maxillofac Surg, 2012 Jun;41(6):783-8.
    PMID: 22424709 DOI: 10.1016/j.ijom.2012.02.003
    This comparative cross-sectional study assessed the facial surface dimensions of a group of Malay children with unilateral cleft lip and palate (UCLP) and compared them with a control group. 30 Malay children with UCLP aged 8-10 years and 30 unaffected age-matched children were voluntarily recruited from the Orthodontic Specialist Clinic in Hospital Universiti Sains Malaysia (HUSM). For the cleft group, lip and palate were repaired and assessment was performed prior to alveolar bone grafting and orthodontic treatment. The investigation was carried out using 3D digital stereophotogrammetry. 23 variables and two ratios were compared three-dimensionally between both groups. Statistically significant dimensional differences (P<0.05) were found between the UCLP Malay group and the control group mainly in the nasolabial region. These include increased alar base and alar base root width, shorter upper lip length, and increased nose base/mouth width ratio in the UCLP group. There were significant differences between the facial surface morphology of UCLP Malay children and control subjects. Particular surgical procedures performed during primary surgeries may contribute to these differences and negatively affect the surgical outcome.
    Matched MeSH terms: Imaging, Three-Dimensional/methods*
  5. Malik AS, Khairuddin RN, Amin HU, Smith ML, Kamel N, Abdullah JM, et al.
    Biomed Eng Online, 2015;14:21.
    PMID: 25886584 DOI: 10.1186/s12938-015-0006-8
    Consumer preference is rapidly changing from 2D to 3D movies due to the sensational effects of 3D scenes, like those in Avatar and The Hobbit. Two 3D viewing technologies are available: active shutter glasses and passive polarized glasses. However, there are consistent reports of discomfort while viewing in 3D mode where the discomfort may refer to dizziness, headaches, nausea or simply not being able to see in 3D continuously.
    Matched MeSH terms: Imaging, Three-Dimensional/adverse effects*
  6. Lo TS, Tan YL, Wu PY, Cortes EF, Pue LB, Al-Kharabsheh A
    PMID: 25265496 DOI: 10.1016/j.ejogrb.2014.09.015
    To evaluate the ultrasound morphology and its clinical outcome among women who had undergone Miniarc™ vs Monarc™ in the treatment of stress urinary incontinence (SUI).
    Matched MeSH terms: Imaging, Three-Dimensional
  7. Fallahiarezoodar A, Abdul Kadir MR, Alizadeh M, Naveen SV, Kamarul T
    Knee Surg Sports Traumatol Arthrosc, 2014 Dec;22(12):3019-27.
    PMID: 25149643 DOI: 10.1007/s00167-014-3227-7
    PURPOSE: Reproducing the femoral rollback through specially designed mechanism in knee implants is required to achieve full knee function in total knee arthroplasty. Most contemporary implants use cam/post mechanism to replace the function of Posterior Cruciate Ligament. This study was aimed to determine the most appropriate cam and post designs to produce normal femoral rollback of the knee.

    METHODS: Three different cams (triangle, ellipse, and circle) and three different posts (straight, convex, concave) geometries were considered in this study and were analysed using kinematic analyses. Femoral rollback did not occur until reaching 50° of knee flexion. Beyond this angle, two of the nine combinations demonstrate poor knee flexion and were eliminated from the study.

    RESULTS: The combination of circle cam with concave post, straight post and convex post showed 15.6, 15.9 and 16.1 mm posterior translation of the femur, respectively. The use of ellipse cam with convex post and straight post demonstrated a 15.3 and 14.9 mm femoral rollback, whilst the combination of triangle cam with convex post and straight post showed 16.1 and 15.8 mm femoral rollback, respectively.

    CONCLUSION: The present study demonstrates that the use of circle cam and convex post created the best femoral rollback effect which in turn produces the highest amount of knee flexion. The findings of the study suggest that if the design is applied for knee implants, superior knee flexion may be possible for future patients.

    LEVEL OF EVIDENCE: IV.

    Matched MeSH terms: Imaging, Three-Dimensional
  8. Zain NM, Chelliah KK
    Asian Pac J Cancer Prev, 2014;15(3):1327-31.
    PMID: 24606460
    BACKGROUND: Electrical impedance tomography (EIT) is a new non-invasive, mobile screening method which does not use ionizing radiation to the human breast; allows conducting quantitative assessment of the images besides the visual interpretation. The aim of this study was to correlate the quantitative assessment and visual interpretation of breast electrical impedance tomographs and associated factors.

    MATERIALS AND METHODS: One hundred and fifty mammography patients above 40 years and undergoing EIT were chosen using convenient sampling. Visual interpretation of the images was carried out by a radiologist with minimum of three years experience using the breast imaging - electrical impedance (BI-EIM) classification for detection of abnormalities. A set of thirty blinded EIT images were reinterpreted to determine the intra-rater reliability using kappa. Quantitative assessment was by comparison of the breast average electric conductivity with the norm and correlations with visual interpretation of the images were determined using Chi-square. One-way ANOVA was used to compare the mean electrical conductivity between groups and t-test was used for comparisons with pre-existing Caucasians statistics. Independent t-tests were applied to compare the mean electrical conductivity of women with factors like exogenous hormone use and family history of breast cancer.

    RESULTS: The mean electrical conductivity of Malaysian women was significantly lower than that of Caucasians (p<0.05). Quantitative assessment of electrical impedance tomography was significantly related with visual interpretation of images of the breast (p<0.05).

    CONCLUSIONS: Quantitative assessment of electrical impedance tomography images was significantly related with visual interpretation.

    Matched MeSH terms: Imaging, Three-Dimensional
  9. Phua Chee Ee V, Tan BS, Tan AL, Eng KY, Ng BS, Ung NM
    Asian Pac J Cancer Prev, 2013;14(4):2243-8.
    PMID: 23725120
    BACKGROUND: To compare the dosimetric coverage of target volumes and organs at risk in the radical treatment of nasopharyngeal carcinoma (NPC) between intensity-modulated radiotherapy (IMRT) and three- dimensional conformal radiotherapy (3DCRT).

    MATERIALS AND METHODS: Data from 10 consecutive patients treated with IMRT from June-October 2011 in Penang General Hospital were collected retrospectively for analysis. For each patient, dose volume histograms were generated for both the IMRT and 3DCRT plans using a total dose of 70Gy. Comparison of the plans was accomplished by comparing the target volume coverage (5 measures) and sparing of organs at risk (17 organs) for each patient using both IMRT and 3DCRT. The means of each comparison target volume coverage measures and organs at risk measures were obtained and tested for statistical significance using the paired Student t-test.

    RESULTS: All 5 measures for target volume coverage showed marked dosimetric superiority of IMRT over 3DCRT. V70 and V66.5 for PTV70 showed an absolute improvement of 39.3% and 24.1% respectively. V59.4 and V56.4 for PTV59.4 showed advantages of 18.4% and 16.4%. Moreover, the mean PTV70 dose revealed a 5.1 Gy higher dose with IMRT. Only 4 out of 17 organs at risk showed statistically significant difference in their means which were clinically meaningful between the IMRT and 3DCRT techniques. IMRT was superior in sparing the spinal cord (less 5.8Gy), V30 of right parotid (less 14.3%) and V30 of the left parotid (less 13.1%). The V55 of the left cochlea was lower with 3DCRT (less 44.3%).

    CONCLUSIONS: IMRT is superior to 3DCRT due to its dosimetric advantage in target volume coverage while delivering acceptable doses to organs at risk. A total dose of 70Gy with IMRT should be considered as a standard of care for radical treatment of NPC.

    Matched MeSH terms: Imaging, Three-Dimensional
  10. Ishak MI, Abdul Kadir MR, Sulaiman E, Abu Kasim NH
    Int J Oral Maxillofac Surg, 2012 Sep;41(9):1077-89.
    PMID: 22575179 DOI: 10.1016/j.ijom.2012.04.010
    The aim of this study was to compare two different types of surgical approaches, intrasinus and extramaxillary, for the placement of zygomatic implants to treat atrophic maxillae. A computational finite element simulation was used to analyze the strength of implant anchorage for both approaches in various occlusal loading locations. Three-dimensional models of the craniofacial structures surrounding a region of interest, soft tissue and framework were developed using computed tomography image datasets. The implants were modelled using computer-aided design software. The bone was assumed to be linear isotropic with a stiffness of 13.4 GPa, and the implants were assumed to be made of titanium with a stiffness of 110 GPa. Masseter forces of 300 N were applied at the zygomatic arch, and occlusal loads of 150 N were applied vertically onto the framework surface at different locations. The intrasinus approach demonstrated more satisfactory results and could be a viable treatment option. The extramaxillary approach could also be recommended as a reasonable treatment option, provided some improvements are made to address the cantilever effects seen with that approach.
    Matched MeSH terms: Imaging, Three-Dimensional
  11. Fadzli F, Ramli NM, Rahmat K, Ganesan D
    Childs Nerv Syst, 2013 Jan;29(1):159-62.
    PMID: 22996826 DOI: 10.1007/s00381-012-1923-5
    Intraventricular haemorrhage is the most common cause of hydrocephalus in a pre-term baby and may require surgical intervention depending on severity.
    Matched MeSH terms: Imaging, Three-Dimensional
  12. Choo WS, Steeds RP
    Br J Radiol, 2011 Dec;84 Spec No 3:S245-57.
    PMID: 22723532 DOI: 10.1259/bjr/54030257
    The aim of this article is to provide a perspective on the relative importance and contribution of different imaging modalities in patients with valvular heart disease. Valvular heart disease is increasing in prevalence across Europe, at a time when the clinical ability of physicians to diagnose and assess severity is declining. Increasing reliance is placed on echocardiography, which is the mainstay of cardiac imaging in valvular heart disease. This article outlines the techniques used in this context and their limitations, identifying areas in which dynamic imaging with cardiovascular magnetic resonance and multislice CT are expanding.
    Matched MeSH terms: Imaging, Three-Dimensional
  13. Vairavan N, Tajunisah I, Subrayan V, Waran V
    Orbit, 2009;28(6):442-3.
    PMID: 19929682 DOI: 10.3109/01676830903103365
    Surgical approaches are becoming increasingly minimally invasive, without compromising either safety or ease. Penetrating ocular foreign bodies has traditionally been approached either by intraocular or supraorbital access. We successfully attempted a minimally invasive approach to remove a retrobulbar foreign body under computer-assisted image guidance in a 19-year-old man involved in an industrial mishap.
    Matched MeSH terms: Imaging, Three-Dimensional
  14. Yew CC, Rahman SA, Alam MK
    BMC Pediatr, 2015;15:169.
    PMID: 26546159 DOI: 10.1186/s12887-015-0495-4
    The Temporomandibular Joint (TMJ) ankylosis in child is rare and yet the causes still remain unclear. This condition that affects the feeding and possible airway obstruction do not only worry the parents, but also possesses as a great challenge to the surgeons. Furthermore, it interferes with the facial skeletal and dento-alveolar development in the on growing child.
    Matched MeSH terms: Imaging, Three-Dimensional
  15. Hai-Ying C, Guzmán Rojas R, Hall JC, Atan IK, Dietz HP
    Int Urogynecol J, 2016 Feb;27(2):229-32.
    PMID: 26264476 DOI: 10.1007/s00192-015-2813-7
    INTRODUCTION AND HYPOTHESIS: Obstructed defecation is a common symptom complex in urogynaecological patients, and perineal, vaginal and/or anal digitation may required for defecation. Translabial ultrasound can be used to assess anorectal anatomy, similar to defecation proctography. The aim of the present study was to determine the association between different forms of digitation (vaginal, perineal and anal) and abnormal posterior compartment anatomy.

    METHODS: A total of 271 patients were analysed in a retrospective study utilising archived ultrasound volume datasets. Symptoms of obstructed defecation (straining at stool, incomplete bowel emptying, perineal, vaginal and anal digitation) were ascertained on interview. Postprocessing of stored 3D/4D translabial ultrasound datasets obtained on maximal Valsalva was used to diagnose descent of the rectal ampulla, rectocoele, enterocoele and rectal intussusception at a later date, blinded to all clinical data.

    RESULTS: Digitation was reported by 39 % of our population. The position of the rectal ampulla on Valsalva was associated with perineal (p = 0.02) and vaginal (p = 0.02) digitation. The presence of a true rectocoele was significantly associated with perineal (p = 0.04) and anal (p = 0.03) digitation. Rectocoele depth was associated with all three forms of digitation (P = 0.005-0.02). The bother of symptoms of obstructed defecation was strongly associated with digitation (all P three forms.

    CONCLUSION: Digitation is common, and all forms of digitation are associated with abnormal posterior compartment anatomy. It may not be necessary to distinguish between different forms of digitation in clinical practice.

    Matched MeSH terms: Imaging, Three-Dimensional
  16. Hisham S, Abdullah N, Mohamad Noor MH, Franklin D
    J Forensic Sci, 2019 Nov;64(6):1803-1811.
    PMID: 31310668 DOI: 10.1111/1556-4029.14125
    Forensic age estimation methods are biased to sex and population; in general, accuracy is reduced when applied to foreign populations. This study assessed the accuracy of the Suchey-Brooks method in contemporary Malaysian individuals and aimed to formulate population-specific standards. Multi-detector computed tomography scans of 355 individuals (165 male; 190 female) of 15-83 years of age were reconstructed using 3D-volumetric rendering in RadiAnt. Pubic symphyseal phase, bias, inaccuracy, and percentage correct age classifications are examined. Transition analysis was used to develop age estimation standards. High observer agreement (κ = 0.763-0.832) and a positive relationship between age and pubic symphyseal phase (r = 0.884-0.90) were demonstrated. Mean inaccuracies were 8.62 and 8.95 years for males and females, respectively; overall correct classification was 97.8%. Transition ages between phases in males were 18.79, 23.29, 28.85, 43.64, and 61.15 years; in females, the corresponding data were 19.77, 22.53, 32.62, 41.85, and 57.39 years.
    Matched MeSH terms: Imaging, Three-Dimensional
  17. Qabbani AA, Razak NHA, Kawas SA, Sheikh Abdul Hamid S, Wahbi S, Samsudin AR
    J Craniofac Surg, 2017 Jun;28(4):e318-e325.
    PMID: 28230596 DOI: 10.1097/SCS.0000000000003569
    The aim of this study was to determine the efficacy of immediate implant placement with alveolar bone augmentation on socket preservation following atraumatic tooth extraction and comparing it with a tooth alveolar socket that was allowed to heal in a conventional way.Twenty medically fit patients (8 males and 12 females aged between 18 and 40 years) who needed noncomplicated tooth extraction of mandibular premolar teeth were divided randomly and equally into 2 groups. In Group I, the empty extraction socket was left untreated and allowed to heal in a conventional way. In Group II, the immediate implant was placed and the gap between the implant and the inner buccal plate surface of the socket wall was filled with lyophilized bovine bone granules and the wound was covered with pericardium membrane. The patients were followed up clinically and radiologically for regular reviews at 1 week, 3 months, and 9 months postoperative. Cone beam computerized tomography images of the alveolar ridge and socket were analyzed to determine the structural changes of the alveolar ridge. Resonance frequency analysis was measured at 9 months for Group II to assess the degree of secondary stability of the implants by using Osstell machine.A significant difference of bone resorption of 1.49 mm (confidence interval, CI 95%, 0.63-2.35) was observed within the control group at 3 months, and 1.84 mm (P ≤ 0.05) at 9 months intervals. No significant changes of bone resorption were observed in Group II. Comparison between groups showed a highly significant difference at 3 months; 2.56 mm (CI 95% 4.22-0.90) and at 9 months intervals; 3.2 mm (CI 95%, 4.70-1.62) P ≤ 0.001 between Group I and II. High resonance frequency analysis values were observed at 9 months postoperative in Group II.In conclusion, the insertion of immediate implants in fresh extraction sockets together with grafting the circumferential gap between the bony socket wall and the implant surface with bovine bone granules was able to preserve a greater amount of alveolar ridge volume when compared with an extraction socket that was left to heal in a conventional way.
    Matched MeSH terms: Imaging, Three-Dimensional
  18. Haranal M, Leong MC, Muniandy SR, Khalid KF, Sivalingam S
    Ann Thorac Surg, 2020 10;110(4):e327-e329.
    PMID: 32224240 DOI: 10.1016/j.athoracsur.2020.02.039
    Conjoined twins are rare congenital malformations known to be associated with cardiac abnormalities. Management of transposition of the great arteries with an intact ventricular septum in this subgroup of patients is challenging, especially in the presence of multiple comorbidities. Prevention of left ventricular involution until the patient is stable for an arterial switch operation is a real challenge. We report a case of early ductal stenting to keep the left ventricle well trained in a separated conjoined twin who eventually underwent an arterial switch operation.
    Matched MeSH terms: Imaging, Three-Dimensional
  19. Maherally Z, Fillmore HL, Tan SL, Tan SF, Jassam SA, Quack FI, et al.
    FASEB J, 2018 01;32(1):168-182.
    PMID: 28883042 DOI: 10.1096/fj.201700162R
    The blood-brain barrier (BBB) consists of endothelial cells, astrocytes, and pericytes embedded in basal lamina (BL). Most in vitro models use nonhuman, monolayer cultures for therapeutic-delivery studies, relying on transendothelial electrical resistance (TEER) measurements without other tight-junction (TJ) formation parameters. We aimed to develop reliable, reproducible, in vitro 3-dimensional (3D) models incorporating relevant human, in vivo cell types and BL proteins. The 3D BBB models were constructed with human brain endothelial cells, human astrocytes, and human brain pericytes in mono-, co-, and tricultures. TEER was measured in 3D models using a volt/ohmmeter and cellZscope. Influence of BL proteins-laminin, fibronectin, collagen type IV, agrin, and perlecan-on adhesion and TEER was assessed using an electric cell-substrate impedance-sensing system. TJ protein expression was assessed by Western blotting (WB) and immunocytochemistry (ICC). Perlecan (10 µg/ml) evoked unreportedly high, in vitro TEER values (1200 Ω) and the strongest adhesion. Coculturing endothelial cells with astrocytes yielded the greatest resistance over time. ICC and WB results correlated with resistance levels, with evidence of prominent occludin expression in cocultures. BL proteins exerted differential effects on TEER, whereas astrocytes in contact yielded higher TEER values and TJ expression.-Maherally, Z., Fillmore, H. L., Tan, S. L., Tan, S. F., Jassam, S. A., Quack, F. I., Hatherell, K. E., Pilkington, G. J. Real-time acquisition of transendothelial electrical resistance in an all-human, in vitro, 3-dimensional, blood-brain barrier model exemplifies tight-junction integrity.
    Matched MeSH terms: Imaging, Three-Dimensional
  20. Ng CK, Chen JY, Yeh JZY, Ho JPY, Merican AM, Yeo SJ
    J Arthroplasty, 2018 06;33(6):1936-1944.
    PMID: 29395720 DOI: 10.1016/j.arth.2017.12.025
    BACKGROUND: We hypothesized that there is a correlation between the distal femoral rotation and proximal tibial joint line obliquity in nonarthritic knees. This has significance for kinematic knee arthroplasty, in which the target knee alignment desired approximates the knee before disease.

    METHODS: Fifty computed tomography scans of nonarthritic knees were evaluated using three-dimensional image processing software. Four distal femoral rotational axes were determined in the axial plane: the transepicondylar axis (TEA), transcondylar axis (TCA), posterior condylar axis (PCA), and a line perpendicular to Whiteside's anterior-posterior axis. Then, angles were measured relative to the TEA. Tibial joint line obliquity was measured as the angle between the proximal tibial plane and a line perpendicular to the axis of the tibia.

    RESULTS: There was a strong positive correlation between PCA-TEA and tibial joint line obliquity (r = 0.68, P < .001) as well as TCA-TEA and tibial joint line obliquity (r = 0.69, P < .001). In addition, the tibial joint line obliquity and TCA-TEA angles were similar, 3.7° ± 2.2° (mean ± standard deviation) and 3.5° ± 1.7°, respectively (mean difference, 0.2° ± 0.2°; P = .369).

    CONCLUSION: Both PCA-TEA and TCA-TEA strongly correlated with proximal tibial joint line obliquity indicating a relationship between distal femoral rotational geometry and proximal tibial inclination. These findings could imply that the native knee in flexion attempts to balance the collateral ligaments toward a rectangular flexion space. A higher tibial varus inclination is matched with a more internally rotated distal femur relative to the TEA.

    Matched MeSH terms: Imaging, Three-Dimensional
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links