Displaying publications 141 - 160 of 712 in total

Abstract:
Sort:
  1. Kron T, Healy B, Ng KH
    Phys Med, 2016 Jul;32(7):883-8.
    PMID: 27320695 DOI: 10.1016/j.ejmp.2016.06.001
    OBJECTIVE: Our study aims to assess and track work load, working conditions and professional recognition of radiation oncology medical physicists (ROMPs) in the Asia Pacific Region over time.

    METHODS: A structured questionnaire was mailed in 2008, 2011 and 2014 to senior medical physicists representing 23 countries. The questionnaire covers 7 themes: education and training including certification; staffing; typical tasks; professional organisations; resources; research and teaching; job satisfaction.

    RESULTS: Across all surveys the response rate was >85% with the replies representing practice affecting more than half of the world's population. The expectation of ROMP qualifications (MSc and between 1 and 3years of clinical experience) has not changed much over the years. However, compared to 2008, the number of medical physicists in many countries has doubled. Formal professional certification is only available in a small number of countries. The number of experienced ROMPs is small in particular in low and middle income countries. The increase in staff numbers from 2008 to 2014 is matched by a similar increase in the number of treatment units which is accompanied by an increase in treatment complexity. Many ROMPs are required to work overtime and not many find time for research. Resource availability has only improved marginally and ROMPs still feel generally overworked, but professional recognition, while varying widely, appears to be improving slowly.

    CONCLUSION: While number of physicists and complexity of treatment techniques and technologies have increased significantly, ROMP practice remains essentially unchanged over the last 6years in the Asia Pacific Region.

    Matched MeSH terms: Radiation Oncology/trends*
  2. Rahman WN, Corde S, Yagi N, Abdul Aziz SA, Annabell N, Geso M
    Int J Nanomedicine, 2014;9:2459-67.
    PMID: 24899803 DOI: 10.2147/IJN.S59471
    Gold nanoparticles have been shown to enhance radiation doses delivered to biological targets due to the high absorption coefficient of gold atoms, stemming from their high atomic number (Z) and physical density. These properties significantly increase the likelihood of photoelectric effects and Compton scattering interactions. Gold nanoparticles are a novel radiosensitizing agent that can potentially be used to increase the effectiveness of current radiation therapy techniques and improve the diagnosis and treatment of cancer. However, the optimum radiosensitization effect of gold nanoparticles is strongly dependent on photon energy, which theoretically is predicted to occur in the kilovoltage range of energy. In this research, synchrotron-generated monoenergetic X-rays in the 30-100 keV range were used to investigate the energy dependence of radiosensitization by gold nanoparticles and also to determine the photon energy that produces optimum effects. This investigation was conducted using cells in culture to measure dose enhancement. Bovine aortic endothelial cells with and without gold nanoparticles were irradiated with X-rays at energies of 30, 40, 50, 60, 70, 81, and 100 keV. Trypan blue exclusion assays were performed after irradiation to determine cell viability. Cell radiosensitivity enhancement was indicated by the dose enhancement factor which was found to be maximum at 40 keV with a value of 3.47. The dose enhancement factor obtained at other energy levels followed the same direction as the theoretical calculations based on the ratio of the mass energy absorption coefficients of gold and water. This experimental evidence shows that the radiosensitization effect of gold nanoparticles varies with photon energy as predicted from theoretical calculations. However, prediction based on theoretical assumptions is sometimes difficult due to the complexity of biological systems, so further study at the cellular level is required to fully characterize the effects of gold nanoparticles with ionizing radiation.
    Matched MeSH terms: Cell Survival/radiation effects; Radiation Tolerance/drug effects*; Radiation Tolerance/physiology; Endothelial Cells/radiation effects*; Absorption, Radiation/drug effects*
  3. Pang YL, Abdullah AZ
    Ultrason Sonochem, 2012 May;19(3):642-51.
    PMID: 22000097 DOI: 10.1016/j.ultsonch.2011.09.007
    Sonocatalytic degradation of various organic dyes (Congo Red, Reactive Blue 4, Methyl Orange, Rhodamine B and Methylene Blue) catalyzed by powder and nanotubes TiO(2) was studied. Both catalysts were characterized using transmission electron microscope (TEM), surface analyzer, Raman spectroscope and thermal gravimetric analyzer (TGA). Sonocatalytic activity of powder and nanotubes TiO(2) was elucidated based on the degradation of various organic dyes. The former catalyst was favorable for treatment of anionic dyes, while the latter was more beneficial for cationic dyes. Sonocatalytic activity of TiO(2) nanotubes could be up to four times as compared to TiO(2) powder under an ultrasonic power of 100 W and a frequency of 42 kHz. This was associated with the higher surface area and the electrostatic attraction between dye molecules and TiO(2) nanotubes. Fourier transform-infrared spectrometer (FT-IR) was used to identify changes that occurred on the functional group in Rhodamine B molecules and TiO(2) nanotubes after the reaction. Sonocatalytic degradation of Rhodamine B by TiO(2) nanotubes apparently followed the Langmuir-Hinshelwood adsorption kinetic model with surface reaction rate of 1.75 mg/L min. TiO(2) nanotubes were proven for their high potential to be applied in sonocatalytic degradation of organic dyes.
    Matched MeSH terms: Catalysis/radiation effects; Coloring Agents/radiation effects*; Organic Chemicals/radiation effects*; Radiation Dosage; Titanium/radiation effects; Water Pollutants, Chemical/radiation effects; Nanotubes/radiation effects*
  4. Ho E
    Biomed Imaging Interv J, 2010 Jul-Sep;6(3):e8.
    PMID: 21611049 DOI: 10.2349/biij.6.3.e8
    When x-rays were first discovered, the harmful effects of radiation had to be manifest in the early users before they were known. Today, radiation protection and safety have been established and the effects of radiation, as well as its risks, are known. Even so, medical radiation, in particular the growth in the use of computed tomography (CT), has resulted in soaring radiation doses received by the population in general. Inappropriate use has resulted in overuse, overdose and, perhaps, overdiagnosis, especially when used in screening. In the quest to control and curb the use of procedures involving radiation, however, we must be careful not to provoke a pandemic of irrational fear of radiation. Overreaction to the overuse and overdose of radiation might deter patients from life-saving procedures.
    Matched MeSH terms: Radiation Dosage; Radiation Protection
  5. Muhammad BG, Jaafar MS, Akpa TC
    Radiat Prot Dosimetry, 2010 Sep;141(2):127-33.
    PMID: 20562117 DOI: 10.1093/rpd/ncq162
    Stratified sampling procedure was employed to collect a total of 40 samples; 2 from each stratum, measuring an approximate dimension of 3.25 km(2) of the actual sample site. Appropriate volumes were then evaporated and transferred into clean stainless steel planchets (ISO 9696 and ISO 9697). An eight channel gas-flow proportional counting system connected to a microprocessor loaded with a spreadsheet programme (Quarttro-Pro) and graphic programme (Multiplan) initially calibrated for efficiency was employed to count the background and the prepared samples. A mean efficiency of 33.44 and 41.24 % for the respective alpha and beta sources was obtained. A low background activity was also observed with a mean of 0.165 Bq for alpha and 1.119 Bq for beta. The gross alpha and beta activity concentrations in the water were found to range from 80 +/- 0.05 to 2300 +/- 0.41 Bq m(-3) and 120 +/- 0.08 to 4970 +/- 0.78 Bq m(-3), respectively. This clearly indicate areas of elevated alpha and beta activity concentrations of 37.5 and 47.5 %, respectively when compared with the International Commission for Radiological Protection (1991) maximum acceptable values of 500 Bq m(-3) for alpha and 1000 Bq m(-3) for beta.
    Matched MeSH terms: Radiation Monitoring*
  6. Kanaga KC, Yap HH, Laila SE, Sulaiman T, Zaharah M, Shantini AA
    Med J Malaysia, 2010 Jun;65(2):119-22.
    PMID: 23756795 MyJurnal
    Full field digital mammography (FFDM) has been progressively introduced in medical centers in recent years. However, it is questionable which exposure parameters are suitable in order to reduce the glandular breast doses as they are related to induced carcinogenesis. The goal of this study was to compare the average glandular doses (AGD) and image quality of three FFDM systems namely Siemens Mammomat NovationDR, Hologic Lorad Selenia and General Electric Senographe Essential using a Figure of Merit. A Computerized Imaging Reference Systems (CIRS) tissue equivalent breast phantom which consists of phototimer compensation plate with different thickness and glandularity was exposed in fully automatic exposure control mode in the cranio-caudal projection similar to clinical settings. Thermoluminescent dosimeter 100H (TLD- 100H) was used to measure the entrance surface air kerma (ESAK), the AGD was calculated using European protocol whilst the image quality was assessed quantitatively by measuring the contrast to noise ratio (CNR) value. The obtained values were used to calculate the Figure of Merit (FOM) to analyze the effectiveness of the system. Repeated Measures ANOVA analysis showed that there is a significant difference (p<0.05) in the mean value of AGD and CNR between the three FFDM systems. Hologic Lorad Selenia system contrbuted the highest AGD value while General Electric Senographe Essential had the highest CNR and FOM value. In conclusion, this study may provide an objective criterion during the selection of a mammography unit by using the figure of merit for screening or diagnostic purpose.
    Matched MeSH terms: Radiation Dosage*
  7. Salema AA, Ani FN
    Bioresour Technol, 2011 Feb;102(3):3388-95.
    PMID: 20970995 DOI: 10.1016/j.biortech.2010.09.115
    The purpose of this paper was to carry out microwave induced pyrolysis of oil palm biomass (shell and fibers) with the help of char as microwave absorber (MA). Rapid heating and yield of microwave pyrolysis products such as bio-oil, char, and gas was found to depend on the ratio of biomass to microwave absorber. Temperature profiles revealed the heating characteristics of the biomass materials which can rapidly heat-up to high temperature within seconds in presence of MA. Some characterization of pyrolysis products was also presented. The advantage of this technique includes substantial reduction in consumption of energy, time and cost in order to produce bio-oil from biomass materials. Large biomass particle size can be used directly in microwave heating, thus saving grinding as well as moisture removal cost. A synergistic effect was found in using MA with oil palm biomass.
    Matched MeSH terms: Plant Oils/radiation effects*
  8. Yusof N, Morales Pedraza J
    Cell Tissue Bank, 2009 May;10(2):115-7.
    PMID: 18581259 DOI: 10.1007/s10561-008-9085-0
    The IAEA was instrumental in developing the first Malaysian tissue bank at University Hospital of Universiti Sains Malaysia (HUSM), Kubang Kerian, Kelantan in early 1990s and it was officiated as National Tissue Bank in 1994. Up to date, 38 government and private hospitals have received a supply from the bank. Bone allografts in term of bone chips, morsalised bone and long bones are procured from Malaysian donors. Almost thirty students from Malaysia graduated in the training courses carried out in Singapore since 1998 at regional and interregional levels. Organ donation is more readily accepted by the public at the moments, perhaps due to the vast promotion and advertisement given by the local newspapers and other media, but gradually tissue donation is catching up as well.
    Matched MeSH terms: Radiation*
  9. Raber J, Allen AR, Weber S, Chakraborti A, Sharma S, Fike JR
    Behav Brain Res, 2016 Apr 1;302:263-8.
    PMID: 26801826 DOI: 10.1016/j.bbr.2016.01.035
    A unique feature of the space radiation environment is the presence of high-energy charged particles, including (56)Fe ions, which can present a significant hazard to space flight crews during and following a mission. (56)Fe irradiation-induced cognitive changes often involve alterations in hippocampal function. These alterations might involve changes in spine morphology and density. In addition to irradiation, performing a cognitive task can also affect spine morphology. Therefore, it is often hard to determine whether changes in spine morphology and density are due to an environmental challenge or group differences in performance on cognitive tests. In this study, we tested the hypothesis that the ability of exploratory behavior to increase specific measures of hippocampal spine morphology and density is affected by (56)Fe irradiation. In sham-irradiated mice, exploratory behavior increased basal spine density in the CA1 region of the hippocampus and the enclosed blade of the dentate gyrus. These effects were not seen in irradiated mice. In addition, following exploratory behavior, there was a trend toward a decrease in the percent stubby spines on apical dendrites in the CA3 region of the hippocampus in (56)Fe-irradiated, but not sham-irradiated, mice. Other hippocampal regions and spine measures affected by (56)Fe irradiation showed comparable radiation effects in behaviorally naïve and cognitively tested mice. Thus, the ability of exploratory behavior to alter spine density and morphology in specific hippocampal regions is affected by (56)Fe irradiation.
    Matched MeSH terms: Radiation Injuries; Electromagnetic Radiation
  10. Ng KH, Rassiah P, Wang HB, Hambali AS, Muthuvellu P, Lee HP
    Br J Radiol, 1998 Jun;71(846):654-60.
    PMID: 9849390
    A collaborative national survey initiated by the University of Malaya and the Ministry of Health was conducted from 1993 to 1995 to establish baseline patient dose data for seven common types (12 projections) of X-ray examinations in Malaysia. A total of 12 randomly selected public hospitals and 867 patients were included in this survey. The entrance surface doses (ESD) received by the patients were measured using thermoluminescent dosemeters (TLDs) attached to the patient's skin. Histograms are presented showing wide, positively skewed distributions of measured entrance surface doses for each examination. Mean, median, first and third quartile values of ESD and median effective dose are reported. Survey results are generally comparable with those reported in the UK, USA and by the International Atomic Energy Agency (IAEA). The results also provide information on dose level for a lower weight population (mean weight 60 kg) compared with the international reference dose values based on a 70 kg standard. The findings support the importance of the on-going national quality assurance programme to ensure doses are kept to a level consistent with optimum image quality. The data will also be useful for the formulation of national guidance levels as recommended by the IAEA. Furthermore, this study provides patient dosimetry information on healthcare level II countries.
    Matched MeSH terms: Radiation Dosage*
  11. Hu SJ, Chong CS, Subas S
    Health Phys, 1981 Feb;40(2):248-50.
    PMID: 7216807
    Matched MeSH terms: Radiation Monitoring*
  12. Rais NNM, Bradley DA, Hashim A, Osman ND, Noor NM
    Appl Radiat Isot, 2019 Nov;153:108810.
    PMID: 31351374 DOI: 10.1016/j.apradiso.2019.108810
    For a range of doses familiarly incurred in computed tomography (CT), study is made of the performance of Germanium (Ge)-doped fibre dosimeters formed into cylindrical and flat shapes. Indigenously fabricated 2.3 mol% and 6 mol% Ge-dopant concentration preforms have been used to produce flat- and cylindrical-fibres (FF and CF) of various size and diameters; an additional 4 mol% Ge-doped commercial fibre with a core diameter of 50 μm has also been used. The key characteristics examined include the linearity index f(d), dose sensitivity and minimum detectable dose (MDD), the performance of the fibres being compared against that of lithium-fluoride based TLD-100 thermoluminescence (TL) dosimeters. For doses in the range 2-40 milligray (mGy), delivered at constant potential of 120 kilovoltage (kV), both the fabricated and commercial fibres demonstrate supralinear behaviours at doses  4 mGy. In terms of dose sensitivity, all of the fibres show superior TL sensitivity when compared against TLD-100, the 2.3 mol% and 6 mol% Ge-doped FF demonstrating the greatest TL sensitivity at 84 and 87 times that of TLD-100. The TL yields for the novel Ge-doped silica glass render them appealing for use within the present medical imaging dose range, offering linearity at high sensitivity down to less than 2 mGy.
    Matched MeSH terms: Radiation Dosimeters*
  13. Boon IS, Lim JS, Yap MH, Au Yong TPT, Boon CS
    J Med Imaging Radiat Sci, 2020 12;51(4S):S114-S115.
    PMID: 32859543 DOI: 10.1016/j.jmir.2020.08.011
    Matched MeSH terms: Radiation Oncology*
  14. Wong JHD, Zaili Z, Abdul Malik R, Bustam AZ, Saad M, Jamaris S, et al.
    J Appl Clin Med Phys, 2021 Aug;22(8):139-147.
    PMID: 34254425 DOI: 10.1002/acm2.13338
    PURPOSE: This study aims to evaluate in vivo skin dose delivered by intraoperative radiotherapy (IORT) and determine the factors associated with an increased risk of radiation-induced skin toxicity.

    METHODOLOGY: A total of 21 breast cancer patients who underwent breast-conserving surgery and IORT, either as IORT alone or IORT boost plus external beam radiotherapy (EBRT), were recruited in this prospective study. EBT3 film was calibrated in water and used to measure skin dose during IORT at concentric circles of 5 mm and 40 mm away from the applicator. For patients who also had EBRT, the maximum skin dose was estimated using the radiotherapy treatment planning system. Mid-term skin toxicities were evaluated at 3 and 6 months post-IORT.

    RESULTS: The average skin dose at 5 mm and 40 mm away from the applicator was 3.07 ± 0.82 Gy and 0.99 ± 0.28 Gy, respectively. Patients treated with IORT boost plus EBRT received an additional skin dose of 41.07 ± 1.57 Gy from the EBRT component. At 3 months post-IORT, 86% of patients showed no evidence of skin toxicity. However, the number of patients suffering from skin toxicity increased from 15% to 38% at 6 months post-IORT. We found no association between the IORT alone or with the IORT boost plus EBRT and skin toxicity. Older age was associated with increased risk of skin toxicities. A mathematical model was derived to predict skin dose.

    CONCLUSION: EBT3 film is a suitable dosimeter for in vivo skin dosimetry in IORT, providing patient-specific skin doses. Both IORT alone and IORT boost techniques resulted in similar skin toxicity rates.

    Matched MeSH terms: Radiation Injuries*
  15. Chong ZX, Yeap SK, Ho WY
    Int J Radiat Biol, 2021;97(3):289-301.
    PMID: 33356761 DOI: 10.1080/09553002.2021.1864048
    Breast cancer is the most common type of cancer that affects females globally. Radiotherapy is a standard treatment option for breast cancer, where one of its most significant limitations is radioresistance development. MicroRNAs (miRNAs) are small, non-protein-coding RNAs that have been widely studied for their roles as disease biomarkers. To date, several in vitro, in vivo, and clinical studies have reported the roles of miRNAs in regulating radiosensitivity and radioresistance in breast cancer cells. This article reviews the roles of miRNAs in regulating treatment response toward radiotherapy and the associating cellular pathways. We identified 36 miRNAs that play a role in mediating radio-responses; 22 were radiosensitizing, 12 were radioresistance-promoting, and two miRNAs were reported to promote both effects. A brief overview of breast cancer therapy options, mechanism of action of radiation, and molecular mechanism of radioresistance was provided in this article. A summary of the latest clinical researches involving miRNAs in breast cancer radiotherapy was also included.
    Matched MeSH terms: Radiation Tolerance*
  16. Sabarudin A, Mustafa Z, Nassir KM, Hamid HA, Sun Z
    J Appl Clin Med Phys, 2015 Jan;16(1):319-328.
    PMID: 28297258 DOI: 10.1120/jacmp.v16i1.5135
    This phantom study was designed to compare the radiation dose in thoracic and abdomen-pelvic CT scans with and without use of tube current modulation (TCM). Effective dose (ED) and size-specific dose estimation (SSDE) were calculated with the absorbed doses measured at selective radiosensitive organs using a thermoluminescence dosimeter-100 (TLD-100). When compared to protocols without TCM, the ED and SSDE were reduced significantly with use of TCM for both the thoracic and abdomen-pelvic CT. With use of TCM, the ED was 6.50±0.29 mSv for thoracic and 6.01±0.20 mSv for the abdomen-pelvic CT protocols. However without use of TCM, the ED was 20.07±0.24 mSv and 17.30±0.41 mSv for the thoracic and abdomen-pelvic CT protocols, respectively. The corresponding SSDE was 10.18±0.48 mGy and 11.96±0.27 mGy for the thoracic and abdomen-pelvic CT protocols with TCM, and 31.56±0.43 mGy and 33.23±0.05 mGy for thoracic and abdomen-pelvic CT protocols without TCM, respectively. The highest absorbed dose was measured at the breast with 8.58±0.12 mGy in the TCM protocols and 51.52±14.72 mGy in the protocols without TCM during thoracic CT. In the abdomen-pelvic CT, the absorbed dose was highest at the skin with 9.30±1.28 mGy and 29.99±2.23 mGy in protocols with and without use of TCM, respectively. In conclusion, the TCM technique results in significant dose reduction; thus it is to be highly recommended in routine thoracic and abdomen-pelvic CT. PACS numbers: 87.57.Q-, 87.57.qp, 87.53.Bn.
    Matched MeSH terms: Radiation Dosage; Radiation Dosimeters
  17. Ellyda, M.N., Win Mar@Salmah, J.
    MyJurnal
    It is well known that ionizing radiation has an onco-genetic activity and has been implicated in the causation of brain tumors. However, when a new growth appears adjacent to the site of previous tumor, the diagnosis is more toward recurrence. In addition to that, the possible cause might be overlooked, when it occurs many years after radiation treatment. We report a case of radiation-induced meningioma developed 20 years after the patient received radiotherapy for pituitary adenoma.
    Matched MeSH terms: Neoplasms, Radiation-Induced; Radiation, Ionizing
  18. Sabbaghizadeh R, Shamsudin R, Deyhimihaghighi N, Sedghi A
    PLoS One, 2017;12(1):e0168737.
    PMID: 28060829 DOI: 10.1371/journal.pone.0168737
    In the present study, the normoxic polyacrylamide gelatin and tetrakis hydroxy methyl phosphoniun chloride (PAGAT) polymer gel dosimeters were synthesized with and without the presence of silver (Ag) nanoparticles. The amount of Ag nanoparticles varied from 1 to 3 ml with concentration 3.14 g/l, thus forming two types of PAGAT polymer gel dosimeters before irradiating them with 6 to 25 Gy produced by 1.25-MeV 60Co gamma rays. In this range, the predominant gamma ray interaction with matter is by Compton scattering effect, as the photoelectric absorption effect diminishes. MRI was employed when evaluating the polymerization of the dosimeters and the gray scale of the MRI film was determined via an optical densitometer. Subsequent analyses of optical densities revealed that the extent of polymerization increased with the increase in the absorbed dose, while the increase of penetration depth within the dosimeters has a reverse effect. Moreover, a significant increase in the optical density-dose response (11.82%) was noted for dosimeters containing 2 ml Ag nanoparticles.
    Matched MeSH terms: Dose-Response Relationship, Radiation*
  19. Syafiqah, H.N., Umar, R., Kamarudin, M.K.A., Hazmin, S.N., Dianah, A.R.S.N., Jaafar, H., et al.
    ASM Science Journal, 2018;11(101):183-194.
    MyJurnal
    Nowadays, the wireless technology has become a lifestyle; even the children have their own
    mobile phones, although they are categorized as high risk susceptible to health problems
    due to radiation. Thus, the public exposure that stemmed from electromagnetic radiations
    become public concern since studies have been done and the finding showed that the repetitive
    and long term exposure may have adverse health effect. This study was conducted to
    evaluate the exposure level at UMT and UniSZA campuses by measuring the electric field
    strength. This measurement was conducted using omni-directional antenna below 4 GHz,
    connected to spectrum analyzer. In this paper, the measured values are compared with
    the previous study from several locations and then the spatial maps of exposure level are
    developed. The result shows that high exposure level was recorded at UMT and UniSZA.
    From this study, the findings may assist the Ministry of Health to monitor the public health
    due to non-ionizing radiation (NIR) exposure. This is crucial to make sure the international
    commission of non-ionizing radiation protection (ICNIRP) limit is complied. Moreover, the
    development of public NIR exposure policy can be initiated to the Malaysia government for
    health concern. For future study, the investigation of the suitable material used as antenna
    and casing or exposure reduction tool can be done to reduce NIR exposure rate on human
    body.
    Matched MeSH terms: Radiation, Nonionizing; Electromagnetic Radiation
  20. Idrus II, Abdul Latef T, Aridas NK, Abu Talip MS, Yamada Y, Abd Rahman T, et al.
    PLoS One, 2019;14(12):e0226499.
    PMID: 31841536 DOI: 10.1371/journal.pone.0226499
    Researchers are increasingly showing interest in the application of a Butler matrix for fifth-generation (5G) base station antennas. However, the design of the Butler matrix is challenging at millimeter wave because of the very small wavelength. The literature has reported issues of high insertion losses and incorrect output phases at the output ports of the Butler matrix, which affects the radiation characteristics. To overcome these issues, the circuit elements of the Butler matrix such as the crossover, the quadrature hybrid and the phase shifter must be designed using highly accurate dimensions. This paper presents a low-loss and compact single-layer 8 × 8 Butler matrix operating at 28 GHz. The optimum design of each circuit element is also demonstrated in detail. The designed Butler matrix was fabricated to validate the simulated results. The measured results showed return losses of less than -10 dB at 28 GHz. The proposed Butler matrix achieved a low insertion loss and a low phase error of ± 2 dB and ± 10°, respectively. In sum, this work obtained a good agreement between the simulated and measured results.
    Matched MeSH terms: Electromagnetic Radiation*