Displaying publications 1921 - 1940 of 5566 in total

Abstract:
Sort:
  1. Tan XT, Amran FB, Thayan R, Ahmad N, Jaafar R, Haron R, et al.
    Electrophoresis, 2017 09;38(17):2141-2149.
    PMID: 28524240 DOI: 10.1002/elps.201600471
    Leptospirosis is an emerging zoonotic infectious disease in Malaysia. The symptoms of leptospirosis vary from mild nonspecific flu-like illness to a severe condition which is usually associated with serious complication and fatality. To study the protein expression profile of mild and severe leptospirosis, 15 paired sera were collected from the patients who were mildly infected and following that progressed to severe stage. The proteome profiles of mild and severe cases were studied using 2DE analysis in combination with LC-MS/MS. The expression of proteins that were significantly different and had a fold difference of at least 2 had been identified and then validated using Western blot. Our study demonstrated apolipoprotein A-I (APOA-I), serum amyloid A (SAA), transferrin (TF), haptoglobin (HP) and transthyretin (TTR) have significantly different expression between mild and severe leptospirosis. The Ingenuity Pathway Analysis software suggested the expression of these five proteins were modulated by acute phase response signaling pathway. Besides that, a functional network of lipid metabolism, molecular transport and small molecule biochemistry that interconnects these five proteins with interactomes also had been predicted by this software. In conclusion, this finding supports the potential of these five proteins to be the biomarkers for mild and severe human leptospirosis.
    Matched MeSH terms: Leptospirosis/blood*; Biomarkers/blood*
  2. Taniselass S, Arshad MKM, Gopinath SCB, Fathil MFM, Ibau C, Anbu P
    Mikrochim Acta, 2021 07 15;188(8):257.
    PMID: 34268634 DOI: 10.1007/s00604-021-04922-x
    A label-free chemical bonding strategy mediated by reduced graphene oxide (rGO) basal plane functional groups has been developed for cardiac Troponin I (cTnI) detection. Four different chemical strategies on respective electrode sensing surface were precedingly examined using electrochemical impedance spectroscopy. The impedimetric assessment was carried out by sweeping frequency at the range 0.1-500 kHz perturbated at a small amplitude of AC voltage (25 mV). The chemical strategy-4 denoted as S-4 shows a significant analytical performance on cTnI detection in spiked buffer and human serum, whereby the pre-mixture of rGO and (3-Aminopropyl)triethoxysilane (APTES) creates a large number of amine sites (-NH2), which significantly enhanced the antibody immobilization without excessive functionalization. The as-fabricated immunosensor exhibited an ultra-low limit of detection of 6.3 ag mL-1 and the lowest antigen concentration measured was at 10 ag mL-1. The immunosensor showed a linear and wide range of cTnI detection (10 ag mL-1-100 ng mL-1) in human serum with a regression coefficient of 0.9716, rapid detection (5 min of binding time), and stable and highly reproducible bioelectrode response with RSD 
    Matched MeSH terms: Biomarkers/blood*; Troponin I/blood*
  3. Sil BK, Jamiruddin MR, Haq MA, Khondoker MU, Jahan N, Khandker SS, et al.
    Int J Nanomedicine, 2021;16:4739-4753.
    PMID: 34267520 DOI: 10.2147/IJN.S313140
    BACKGROUND: Serological tests detecting severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) are widely used in seroprevalence studies and evaluating the efficacy of the vaccination program. Some of the widely used serological testing techniques are enzyme-linked immune-sorbent assay (ELISA), chemiluminescence immunoassay (CLIA), and lateral flow immunoassay (LFIA). However, these tests are plagued with low sensitivity or specificity, time-consuming, labor-intensive, and expensive. We developed a serological test implementing flow-through dot-blot assay (FT-DBA) for SARS-CoV-2 specific IgG detection, which provides enhanced sensitivity and specificity while being quick to perform and easy to use.

    METHODS: SARS-CoV-2 antigens were immobilized on nitrocellulose membrane to capture human IgG, which was then detected with anti-human IgG conjugated gold nanoparticle (hIgG-AuNP). A total of 181 samples were analyzed in-house. Within which 35 were further evaluated in US FDA-approved CLIA Elecsys SARS-CoV-2 assay. The positive panel consisted of RT-qPCR positive samples from patients with both <14 days and >14 days from the onset of clinical symptoms. The negative panel contained samples collected from the pre-pandemic era dengue patients and healthy donors during the pandemic. Moreover, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of FT-DBA were evaluated against RT-qPCR positive sera. However, the overall efficacies were assessed with sera that seroconverted against either nucleocapsid (NCP) or receptor-binding domain (RBD).

    RESULTS: In-house ELISA selected a total of 81 true seropositive and 100 seronegative samples. The sensitivity of samples with <14 days using FT-DBA was 94.7%, increasing to 100% for samples >14 days. The overall detection sensitivity and specificity were 98.8% and 98%, respectively, whereas the overall PPV and NPV were 99.6% and 99%. Moreover, comparative analysis between in-house ELISA assays and FT-DBA revealed clinical agreement of Cohen's Kappa value of 0.944. The FT-DBA showed sensitivity and specificity of 100% when compared with commercial CLIA kits.

    CONCLUSION: The assay can confirm past SARS-CoV-2 infection with high accuracy within 2 minutes compared to commercial CLIA or in-house ELISA. It can help track SARS-CoV-2 disease progression, population screening, and vaccination response. The ease of use of the assay without requiring any instruments while being semi-quantitative provides the avenue of its implementation in remote areas around the globe, where conventional serodiagnosis is not feasible.

    Matched MeSH terms: Antibodies, Viral/blood; Immunoglobulin G/blood
  4. Yusof Khan AHK, Zakaria NF, Zainal Abidin MA, Kamaruddin NA
    Medicine (Baltimore), 2021 Jul 30;100(30):e26729.
    PMID: 34397709 DOI: 10.1097/MD.0000000000026729
    Glycemic variability (GV) confers a significantly higher risk of diabetic-related complications, especially cardiovascular. Despite extensive research in this area, data on end-stage kidney disease (ESKD) patients on chronic hemodialysis are scarce. This study aims to determine the magnitude of GV among ESKD (diabetic vs nondiabetic) patients and its associated factors on hemodialysis days (HDD) and non-hemodialysis days (NHDD) where postulation of a higher GV observed among diabetic on HDD.We recruited 150 patients on hemodialysis, 93 patients with type 2 diabetic (DM-ESKD), and 57 with nondiabetic (NDM-ESKD). The GV indices (standard deviation [SD] and percentage coefficient variant [%CV]) were obtained from 11-point and 7-point self-monitoring blood glucose (fasting to post-meal) (SMBG) profiles on HDD and NHDD. The GV indices and its associated factors of both DM-ESKD and NDM-ESKD were analyzed to compare HDD vs NHDD.Mean blood glucose on HDD was 9.33 [SD 2.7, %CV 30.6%] mmol/L in DM-ESKD compared with 6.07 [SD 0.85, %CV 21.3%] mmol/L in NDM-ESKD (P = 
    Matched MeSH terms: Diabetes Mellitus, Type 2/blood*; Kidney Failure, Chronic/blood*
  5. Noordin R, Anuar NS, Juri NM, Wongphutorn P, Ruantip S, Kopolrat KY, et al.
    Am J Trop Med Hyg, 2021 07 08;105(3):688-691.
    PMID: 34237022 DOI: 10.4269/ajtmh.21-0317
    Strongyloides stercoralis affects more than half a billion people worldwide, and hyperinfection in immunocompromised patients can be fatal. Elimination of this neglected tropical disease requires field-applicable diagnostic tools. We conducted a laboratory evaluation of a lateral flow rapid dipstick test (SsRapid™) using sera samples from a Strongyloides-endemic area in northeast Thailand. Group 1 was S. stercoralis-positive and larvae- and/or antibody-positive (according to the IgG ELISA) (N = 100). Group 2 had negative fecal examination and IgG ELISA results (N = 25). Group 3 had other parasitic infections and negative IgG ELISA results (N = 25). The results showed good diagnostic sensitivity (82%) and excellent specificity (96%). Suggested improvements in the SsRapid™ test include increased diagnostic sensitivity and conversion to the more robust cassette format. Field studies should be performed as well.
    Matched MeSH terms: Antibodies, Helminth/blood; Strongyloidiasis/blood
  6. Nakai M, Ribeiro RV, Stevens BR, Gill P, Muralitharan RR, Yiallourou S, et al.
    Hypertension, 2021 09;78(3):804-815.
    PMID: 34333988 DOI: 10.1161/HYPERTENSIONAHA.121.17288
    [Figure: see text].
    Matched MeSH terms: Blood Pressure/physiology; Blood Pressure Monitoring, Ambulatory
  7. Leh HE, Mohd Sopian M, Abu Bakar MH, Lee LK
    Ann Med, 2021 12;53(1):1059-1065.
    PMID: 34180336 DOI: 10.1080/07853890.2021.1943515
    BACKGROUND: The use of lycopene as a complementary medicine for Type II diabetes mellitus (T2DM) is limited and controversial. This study evaluated the effect of lycopene intake on the changes of glycaemic status and antioxidant capacity among the T2DM patients.

    PATIENTS AND METHODS: This case-control study involved the participation of 87 patients and 122 healthy individuals. Lycopene intake was assessed by using a food frequency questionnaire. The peripheral antioxidant capacity among the T2DM patients was evaluated. Glycated haemoglobin (HbA1c) and fasting plasma glucose (FPG) were measured as indications of glycaemic status.

    RESULTS: Peripheral antioxidant capacity was significantly lower in the T2DM group. Direct positive correlations were found between the lycopene intake and peripheral antioxidant level among the T2DM patients. Contrarily, HbA1c and FPG levels decreased significantly with the higher lycopene intake.

    CONCLUSIONS: T2DM patients with a higher lycopene intake showed a greater peripheral antioxidant capacity and better glycaemic control. Lycopene may act to ameliorate oxidative stress and improve the pathophysiology of T2DM.

    Matched MeSH terms: Blood Glucose; Diabetes Mellitus, Type 2/blood*
  8. Baig MA, Swamy KB, Baksh AD, Bahashwan A, Moshrif Y, Al Sawat A, et al.
    Indian J Pathol Microbiol, 2021 8 4;64(3):518-523.
    PMID: 34341263 DOI: 10.4103/IJPM.IJPM_709_20
    Background: : HPLC is one of the most important tools for accurate diagnosis of hemoglobinopathies and thalassemias. The advantage of the HPLC system is the excellent resolution, reproducibility &quantification of several normal and abnormal hemoglobin.

    Results: BIO RAD Variant II analyzer was used. Sickle cell syndromes including double heterozygous states accounted for 56.13% of total cases. HbSS, HbS/β0-th, HbS/β+-th β-thal trait comprises 29%, 6.5%, 5.1%& 10% of total cases respectively with mean MCV (fl) = 84, 68,71,64 respectively. The Mean HbA2 for β-thal trait, HbE trait &HbE-β thal showed 5.1 ± 1.1, 19 ± 9 & 24 ± 8 respectively. HbF is increased in 8.6% case (excluding SC syndromes & β-thal disorders), of these 5.5% were infants & 12 cases of Aplastic Anemias. Peak P2 >7% (2.4% cases) was seen in uncontrolled diabetes mellitus which on quantification showed HbA1C = 8 ± 2.1 mmol/L.

    Discussion: : HPLC in correlation with CBC parameters & family studies can aid in the diagnosis of majority of Hemoglobinopathies and thalassemic syndrome. The CBC & HPLC parameters of the present study are in good correlation with the research conducted by Tejinder Sing, RiouJ & Alla Joutovsky. Present study showed HPLC comprehensively characterizing HbS, A, A2, F, S, C, D from each other & was also applicable for the quantification of HbA1c for the monitoring of Diabetes Mellitus.

    Conclusion: : The merits of HPLC are small quantity of sample required, economical, less TAT, accurate categorization of HbS, HbA2 & F. But one has to be aware of the limitations and problems associated with this method due to variant hemoglobin within the same retention windows. The present findings show HPLC as an excellent & powerful diagnostic tool for the direct identification of hemoglobin variants with a high degree of precision in the quantification of normal and abnormal hemoglobin fractions.

    Matched MeSH terms: Hemoglobinopathies/blood; Thalassemia/blood
  9. Wong XZ, Amirah A, Gan CC, Fatiha S, Maznah D, Yahya R, et al.
    Nephrology (Carlton), 2021 May;26(5):463-470.
    PMID: 33580732 DOI: 10.1111/nep.13862
    AIMS: In Malaysia, majority anti-HCV positive haemodialysis patients do not undergo hepatitis C confirmation due to the high cost of HCV RNA. HCV Core Antigen might be a cost-effective diagnostic test to identify HD patients who have active HCV infection eligible for Direct Acting Anti-viral therapy.

    METHODS: A cross-sectional study was conducted to assess the correlation between HCV Ag and HCV RNA and the cost implications of different diagnostic algorithms to diagnose active HCV infection using Anti-HCV, HCV Ag, and HCV RNA. Pre-dialysis blood was tested for both HCV Ag and HCV RNA. HCV Ag was tested with Abbott ARCHITECT HCV Ag test.

    RESULTS: Two-hundred twenty-seven haemodialysis patients were recruited from 20 centres with mean age of 57.68 ± 12.48 years, and male constitutes 56.8% (129) of the study population. HCV Ag correlated well with HCV RNA (Spearman test coefficient 0.943, p 

    Matched MeSH terms: Hepatitis B Core Antigens/blood*; Hepatitis C, Chronic/blood*
  10. Li S, Shaharudin S, Abdul Kadir MR
    Am J Phys Med Rehabil, 2021 Apr 01;100(4):337-344.
    PMID: 33727516 DOI: 10.1097/PHM.0000000000001567
    BACKGROUND: Due to the pain caused by knee injuries, low-load resistance training with blood flow restriction (L-BFR) may be a potential adjuvant therapeutic tool in the rehabilitation of knee injuries. This review aimed to analyze the effectiveness of L-BFR training modality in knee rehabilitation.

    DESIGN: A meta-analysis was conducted to determine the potential impact of blood flow restriction on patients with knee injuries. PubMed, EBSCO, and Web of Science databases were searched for eligible studies from January 2000 until January 2020. The mean differences of the data were analyzed using Revman 5.3 software with a 95% confidence interval.

    RESULTS: Nine studies fulfilled the inclusion criteria. These studies involved 179 patients who received L-BFR, 96 patients who underwent high-load resistance training, and another 94 patients who underwent low-load resistance training. The analysis of pooled data showed that patients in both the L-BFR (standardized mean difference, 0.83 [0.53, 1.14], P < 0.01) and high-load resistance training (standardized mean difference, -0.09 [-0.43, 0.24], P = 0.58) groups experienced an increase in muscle strength after the training. In addition, pain score was significantly reduced in the L-BFR group compared with the other two groups (standardized mean difference, -0.61 [-1.19, -0.03], P = 0.04).

    CONCLUSIONS: Muscle strength increased after L-BFR and high-load resistance training compared with low-load resistance training. Furthermore, pain score was significantly reduced after L-BFR. Hence, L-BFR is a potential intervention to be applied in rehabilitation of knee injuries.

    Matched MeSH terms: Regional Blood Flow; Muscle, Skeletal/blood supply*
  11. Khan K, Khan W, Khan T, Naaz G, Naheda A, Aqeel S
    Trop Biomed, 2020 Dec 01;37(4):1038-1049.
    PMID: 33612756 DOI: 10.47665/tb.37.4.1038
    Toxoplasma gondii is a protozoan parasite that can infect all mammals, serving as intermediate hosts. The cause of congenital toxoplasmosis is transplacental transmission of the parasite to the foetus, resulting in wide range of manifestations from mild chorioretinitis to miscarriage. Its frequency can be reduced by early screening of pregnant women which is based mainly on tests for anti-Toxoplasma antibodies. We collected serum samples of 594 pregnant women (subjects) after taking their consent over a period of two years (2016-2018) and analyzed them for anti-Toxoplasma IgG by ELISA. The positive samples were then analyzed for IgG avidity test which could differentiate between recent and past infections. The seroprevalence was also correlated with the age of the subjects and their contact with cats. 162 subjects were found positive out of which only three showed a recent infection. After following up until delivery, one of them delivered a baby who had jaundice and was diagnosed with anti-Toxoplasma IgM at birth. The foetus of the second subject died in-utero, while the third woman delivered a normal baby after being given spiramycin when diagnosed with toxoplasmosis in the first trimester. It was found that most of the positive subjects had frequent contact with cats. Invasion of the parasite during third trimester resulted in death in-utero and jaundice. Most common cause of pregnancy wastage during our study was spontaneous abortions while pregnancy loss due to congenital anomalies was rare.
    Matched MeSH terms: Antibodies, Protozoan/blood*; Immunoglobulin G/blood*
  12. Mohd R, Mohammad Kazmin NE, Abdul Cader R, Abd Shukor N, Wong YP, Shah SA, et al.
    PLoS One, 2021;16(4):e0249592.
    PMID: 33831052 DOI: 10.1371/journal.pone.0249592
    INTRODUCTION: IgA nephropathy (IgAN) has a heterogeneous presentation and the progression to end stage renal disease (ESRD) is often influenced by demographics, ethnicity, as well as choice of treatment regimen. In this study, we investigated the long term survival of IgAN patients in our center and the factors affecting it.

    METHODS: This study included all biopsy-proven IgAN patients with ≥ 1year follow-up. Patients with diabetes mellitus at diagnosis and secondary IgAN were excluded. Medical records were reviewed for demographics, clinical presentation, blood pressure, 24-hour urine protein, serum creatinine, renal biopsy and treatment received. The primary outcome was defined as combined event of 50% estimated glomerular filtration rate (eGFR) reduction or ESRD.

    RESULTS: We included 130 (74 females; 56 males) patients of mean age 38.0 ± 14.0 years and median eGFR of 75.2 (interquartile range (IQR) 49.3-101.4) ml/min/1.73m2. Eighty-four (64.6%) were hypertensive at presentation, 35 (26.9%) had nephrotic syndrome and 57 (43.8%) had nephrotic range proteinuria (NRP). Median follow-up duration was 7.5 (IQR 4.0-13.0) years. It was noted that 18 (13.8%) developed ESRD and 34 (26.2%) reached the primary outcome. Annual eGFR decline was -2.1 (IQR -5.3 to -0.1) ml/min/1.73m2/year, with median survival of 20 years. Survival rates from the combined event (50% decrease in eGFR or ESRD) at 10, 20 and 30 years were 80%, 53% and 25%, while survival from ESRD were 87%, 73% and 65%, respectively. In the univariate analysis, time-average proteinuria (hazard ratio (HR) = 2.41, 95% CI 1.77-3.30), eGFR <45ml/min/1.73m2 at biopsy (HR = 2.35, 95% CI 1.03-5.32), hypertension (HR = 2.81, 95% CI 1.16-6.80), mean arterial pressure (HR = 1.02, 95% CI 1.01-1.04), tubular atrophy/interstitial fibrosis score (HR = 3.77, 95% CI 1.84-7.73), and cellular/fibrocellular crescent score (HR = 2.44, 95% CI 1.19-5.00) were found to be significant. Whereas only time-average proteinuria (TA-proteinuria) remained as a significant predictor in the multivariate analysis (HR = 2.23, 95% CI 1.57-3.16).

    CONCLUSION: In our cohort, TA-proteinuria was the most important predictor in the progression of IgAN, irrespective of degree of proteinuria at presentation.

    Matched MeSH terms: Creatinine/blood*; Glomerulonephritis, IGA/blood
  13. Thor SM, Yau JW, Ramadas A
    PLoS One, 2021;16(9):e0257433.
    PMID: 34520483 DOI: 10.1371/journal.pone.0257433
    Metabolic syndrome (MetS) is frequently associated with various health issues and is a major contributor to morbidity and mortality worldwide, particularly with its recent relevance to coronavirus disease 2019 (COVID-19). To combat its increasing prevalence in Southeast Asia, numerous intervention programs have been implemented. We conducted a scoping review on recent interventions to manage MetS among Southeast Asians using standard methodologies. Cochrane, Embase, Ovid MEDLINE, PubMed, and Scopus databases were systematically searched to yield peer-reviewed articles published between 2010-2020. We included 13 articles describing 11 unique interventions in four Southeast Asian countries: Malaysia, Thailand, Indonesia, and Vietnam. These interventions were broadly categorized into four groups: (i) nutrition (n = 4); (ii) physical activity (n = 2); (iii) nutrition and physical activity (n = 2); and (iv) multi-intervention (n = 3). Most studies investigated the effects of an intervention on components of MetS, which are anthropometry, blood pressure, glucose-related parameters, and lipid profile. Significant improvements ranged from 50% of studies reporting serum triglyceride and HDL-cholesterol levels to 100% for waist circumference. Evidence on interventions for individuals with MetS remains limited in Southeast Asia. More studies from other countries in this region are needed, especially on the effects of dietary interventions, to effectively address gaps in knowledge and provide sufficient data to design the ideal intervention for Southeast Asian populations.
    Matched MeSH terms: Lipids/blood; Metabolic Syndrome X/blood
  14. Zin NM, Othman SN, Abd Rahman FR, Abdul Rachman AR
    Trop Biomed, 2019 Dec 01;36(4):1071-1080.
    PMID: 33597476
    Leptospirosis is a worldwide zoonotic disease caused by spirochetes of the genus Leptospira. The clinical manifestation of leptospirosis is non-specific and frequently misdiagnosed as other illnesses. The aim of this study was to compare the diagnostic accuracies of two commercial tests for early diagnosis of Leptospira species: the IgM latex agglutination test (IgM LAT) and the IgM enzyme-linked immunosorbent assay (IgM ELISA). A total of 140 serum samples were obtained from patients suspected of leptospirosis at the Universiti Kebangsaan Malaysia Medical Centre (UKMMC). These serum samples were tested for the presence of Leptospira sp. using IgM LAT, IgM ELISA and MAT. From Table 1, IgM LAT showed 21% (n = 29) positive, 18% (n = 25) inconclusive and 61% (n = 86) negative, while IgM ELISA showed 6% (n = 8) positive, 6% (n = 8) inconclusive, 88% (n = 124) negative and MAT showed 11% (n = 16) positive, 47% (n = 65) inconclusive, 42% (n = 59) negative. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of IgM LAT were 68.8%, 57.6%, 30.6% and 87.2% respectively, while for IgM ELISA they were 37.5%, 89.8%, 50% and 84.1%, respectively as compared to MAT (Table 2). The results showed that IgM LAT had higher sensitivity but lower specificity compared to IgM ELISA. In conclusion, IgM LAT can be useful as an early screening test for early diagnosis of Leptospira sp., while IgM ELISA is a suitable method for reducing false negative detection of Leptospira sp. As both tests show moderate percentages (~65%) in accuracy, an additional test is required for better detection of Leptospira sp.
    Matched MeSH terms: Antibodies, Bacterial/blood*; Immunoglobulin M/blood*
  15. Soo KM, Tham CL, Khalid B, Basir R, Chee HY
    Trop Biomed, 2019 Dec 01;36(4):1027-1037.
    PMID: 33597472
    Dengue is a common infection, caused by dengue virus. There are four different dengue serotypes, with different capacity to cause severe dengue infections. Besides, secondary infections with heterologous serotypes, concurrent infections of multiple dengue serotypes may alter the severity of dengue infection. This study aims to compare the severity of single infection and concurrent infections of different combinations of dengue serotypes in-vitro. Human mast cells (HMC)-1.1 were infected with single and concurrent infections of multiple dengue serotypes. The infected HMC-1.1 supernatant was then added to human umbilical cord vascular endothelial cells (HUVEC) and severity of dengue infections was measured by the percentage of transendothelial electrical resistance (TEER). Levels of IL10, CXCL10 and sTRAIL in HMC-1.1 and IL-8, IL-10 and CXCL10 in HUVEC culture supernatants were measured by the ELISA assays. The result showed that the percentage of TEER values were significantly lower in single infections (p< 0.05), compared to concurrent infections on day 2 and 3, indicating that single infection increase endothelial permeability greater than concurrent infections. IL-8 showed moderate correlation with endothelial permeability (r > 0.4), indicating that IL-8 may be suitable as an in-vitro severity biomarker. In conclusion, this in-vitro model presented few similarities with regards to the conditions in dengue patients, suggesting that it could serve as a severity model to test for severity and levels of severity biomarkers upon different dengue virus infections.
    Matched MeSH terms: Biomarkers/blood; Interleukin-8/blood*
  16. Rivera NS, Tiongco REG, Salita CL, Kawano RL
    Trop Biomed, 2019 Dec 01;36(4):993-1002.
    PMID: 33597469
    Transfusion of blood is a life-saving intervention that saves many lives. Unsafe practices in blood donation and pre-transfusion testing place people's lives at risk of transfusion transmissible infections (TTIs). The study aims to determine the overall seroprevalence of the selected TTIs for the past 5 years (2013-2017) among blood donors from a hospital in Region 3, Philippines. The trend and distribution of the TTIs according to age group, sex, donor category, and number of donations were also determined. Data extracted include the age, sex, donor category, number of donations, and screening results of all donors from January 2013 to December 2017. The overall seroprevalence of the selected TTIs from over the 5-year period is 4.17%. The seroprevalence rates of hepatitis B, hepatitis C, HIV and syphilis from 2013 to 2017 are 2.87%, 0.48%, 0.10%, and 0.62%, respectively. The age group of 25 to 44 years old showed the highest rate of reactive donors. Also, higher rates of reactive donors are seen among male donors, replacement donors, and first-time donors. The overall seroprevalence of TTIs in the study locale is low and it shows a decreasing trend from 2013 to 2017. Donors who are 25 to 44 years old, males, replacement, and first-time donors showed highest seroprevalence rates of TTIs.
    Matched MeSH terms: Blood Donors*; Blood Safety
  17. Chan AML, Ng AMH, Mohd Yunus MH, Idrus RBH, Law JX, Yazid MD, et al.
    Nutrients, 2021 Jul 22;13(8).
    PMID: 34444658 DOI: 10.3390/nu13082497
    Metabolic syndrome (MetS) is the physiological clustering of hypertension, hyperglycemia, hyperinsulinemia, dyslipidemia, and insulin resistance. The MetS-related chronic illnesses encompass obesity, the cardiovascular system, renal operation, hepatic function, oncology, and mortality. To perform pre-clinical research, it is imperative that these symptoms be successfully induced and optimized in lower taxonomy. Therefore, novel and future applications for a disease model, if proven valid, can be extrapolated to humans. MetS model establishment is evaluated based on the significance of selected test parameters, paradigm shifts from new discoveries, and the accessibility of the latest technology or advanced methodologies. Ultimately, the outcome of animal studies should be advantageous for human clinical trials and solidify their position in advanced medicine for clinicians to treat and adapt to serious or specific medical situations. Rodents (Rattus norvegicus and Mus musculus) have been ideal models for mammalian studies since the 18th century and have been mapped extensively. This review compiles and compares studies published in the past five years between the multitude of rodent comparative models. The response factors, niche parameters, and replicability of diet protocols are also compiled and analyzed to offer insight into MetS-related disease-specific modelling.
    Matched MeSH terms: Biomarkers/blood; Metabolic Syndrome X/blood
  18. Al-Jaal B, Latiff A, Salama S, Hussain HM, Al-Thani NA, Al-Naimi N, et al.
    Toxins (Basel), 2021 04 08;13(4).
    PMID: 33917988 DOI: 10.3390/toxins13040267
    Mycotoxins are naturally occurring food toxins worldwide that can cause serious health effects. The measurement of mycotoxin biomarkers in biological fluids is needed to assess individuals' exposure. The aim of this study was to investigate the incidence of mycotoxins in the Qatari population. Serum samples from 412 adults and urinary samples from 559 adults were analyzed for the presence of mycotoxin biomarkers. Multimycotoxin approaches have been applied, using liquid chromatography mass spectrometry methods. Samples were further analyzed for the oxidative stress markers and compared with regard to the incidence of mycotoxins. The presence of mycotoxins was identified in 37% of serum samples and in less than 20% of urine samples. It was found that 88% of positive of the samples were positive for only one mycotoxin, while 12% of positive samples had two or more mycotoxins. Trichothecenes and zearalenone metabolites were most commonly detected mycotoxins, followed by aflatoxins, roquefortine C and mycophenolic acid. The presence of mycotoxins was found to positively correlate with oxidative stress markers. The obtained results illustrate the importance of mycotoxin biomonitoring studies in humans and the need to elucidate the underlying mechanisms of mycotoxin-induced toxicity.
    Matched MeSH terms: Mycotoxins/blood*; Biomarkers/blood
  19. Amiri A, Ghaemi F
    J Chromatogr A, 2021 Jul 05;1648:462168.
    PMID: 33984648 DOI: 10.1016/j.chroma.2021.462168
    In this research, the Cu-based metal-organic framework (MOF-199) was fabricated and coated on the stainless steel mesh as substrates through sol-gel procedure. Then the coated substrates were placed in a small column known as solid-phase extraction cartridge. The SPE based coated stainless steel mesh coupled with high-performance liquid chromatography-UV detector (HPLC-UV) was used for the fast extraction, and quantification of non-steroidal anti-inflammatory drugs (NSAIDs) from human plasma and water samples. To find optimum extraction conditions, the impacts of effective parameters on analytical performance like sample pH, sample volume, type, and volume of desorption solvent were optimized. At the optimized conditions, calibration graphs of analytes were linear in the concentration range of 0.03-300 ng mL-1 for water samples, and 0.1-200 ng mL-1 for plasma samples. The correlation coefficients were in the range of 0.9938 to 0.9989. Also, the limits of detection (LODs) were from 0.01 to 0.02 ng mL-1 for water samples and 0.03 to 0.1 ng mL-1 for plasma samples. The cartridge repeatability was studied at different values, and the relative standard deviations (RSDs%) were achieved between 3.5 and 5.1%. Consequently, this procedure was successfully used in the extraction and detection of NSAIDs in real water and plasma samples with relative recoveries ranged from 93.6 to 99.6%.
    Matched MeSH terms: Anti-Inflammatory Agents, Non-Steroidal/blood*; Water Pollutants, Chemical/blood*
  20. Chong ZL, Soe HJ, Ismail AA, Mahboob T, Chandramathi S, Sekaran SD
    Biosensors (Basel), 2021 Apr 22;11(5).
    PMID: 33921935 DOI: 10.3390/bios11050129
    Dengue is a major threat to public health globally. While point-of-care diagnosis of acute/recent dengue is available to reduce its mortality, a lack of rapid and accurate testing for the detection of previous dengue remains a hurdle in expanding dengue seroepidemiological surveys to inform its prevention, especially vaccination, to reduce dengue morbidity. This study evaluated ViroTrack Dengue Serostate, a biosensors-based semi-quantitative anti-dengue IgG (immunoglobulin G) immuno-magnetic agglutination assay for the diagnosis of previous and recent dengue in a single test. Blood samples were obtained from 484 healthy participants recruited randomly from two communities in Petaling district, Selangor, Malaysia. The reference tests were Panbio Dengue IgG indirect and capture enzyme-linked immunosorbent assays, in-house hemagglutination inhibition assay, and focus reduction neutralization test. Dengue Serostate had a sensitivity and specificity of 91.1% (95%CI 87.8-93.8) and 91.1% (95%CI 83.8-95.8) for the diagnosis of previous dengue, and 90.2% (95%CI 76.9-97.3) and 93.2% (95%CI 90.5-95.4) for the diagnosis of recent dengue, respectively. Its positive predictive value of 97.5% (95%CI 95.3-98.8) would prevent most dengue-naïve individuals from being vaccinated. ViroTrack Dengue Serostate's good point-of-care diagnostic accuracy can ease the conduct of dengue serosurveys to inform dengue vaccination strategy and facilitate pre-vaccination screening to ensure safety.
    Matched MeSH terms: Antibodies, Viral/blood; Dengue/blood
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links