Displaying publications 1 - 20 of 22 in total

Abstract:
Sort:
  1. Fuss FK, Ahmad A, Tan AM, Razman R, Weizman Y
    Sensors (Basel), 2021 Feb 06;21(4).
    PMID: 33562166 DOI: 10.3390/s21041153
    Hard-shell thoracolumbar sacral orthoses (TLSOs) are used for treating idiopathic scoliosis, a deformation of the spine with a sideways curvature. The pressure required inside the TLSO for ideal corrective results remains unclear. Retrofitting TLSOs with commercially available pressure measurement systems is expensive and can only be performed in a laboratory. The aim of this study was to develop a cost-effective but accurate pressure sensor system for TLSOs. The sensor was built from a piezoresistive polymer, placed between two closed-cell foam liners, and evaluated with a material testing machine. Because foams are energy absorbers, the pressure-conductance curve was affected by hysteresis. The sensor was calibrated on a force plate with the transitions from loading to unloading used to establish the calibration curve. The root mean square error was 12% on average within the required pressure range of 0.01-0.13 MPa. The sensor reacted to the changing pressure during breathing and different activities when tested underneath a chest belt at different tensions. The peak pressure reached 0.135 MPa. The sensor was further tested inside the scoliosis brace during different activities. The measured pressure was 0.014-0.124 MPa. The results from this study enable cheaper and mobile systems to be used for clinical studies on the comfort and pressure of braces during daily activities.
    Matched MeSH terms: Braces*
  2. Ahmad A, Abu Osman NA, Mokhtar H, Mehmood W, Kadri NA
    Proc Inst Mech Eng H, 2019 Sep;233(9):901-908.
    PMID: 31244368 DOI: 10.1177/0954411919856144
    The Chêneau brace has proven its effectiveness in treating the adolescent idiopathic scoliosis patients. However, no studies reported on the analysis of interface pressure in double-curve adolescent idiopathic scoliosis patients. In this study, we evaluated the interface pressure of the Chêneau brace action in double-curve adolescent idiopathic scoliosis patient treatment. A total of 72 (60 girls and 12 boys) patients aged 10 years and above participated in the study. The F-Socket transducers (9811E) were used to evaluate the pressure on the right thoracic and left thoracolumbar curves between normal and maximum strap tension and variation in these interface pressures with other tasks. Each patient was asked to do nine different tasks corresponding to daily activities, and the interface pressures for each activity were recorded for both normal and maximum tension. The resultant mean peak pressure in double-curve adolescent idiopathic scoliosis was higher for right thoracic curves than left thoracolumbar curves in all tasks. The pressure significantly increased at the task of maximal inspiration (p 
    Matched MeSH terms: Braces*
  3. Lee YJ, Wang WJ, Mohamad SM, Chandren JR, Gani SMA, Chung WH, et al.
    Eur Spine J, 2024 Feb;33(2):630-645.
    PMID: 37924388 DOI: 10.1007/s00586-023-08007-6
    PURPOSE: To compare the Boston brace and European braces using a standardised Scoliosis Research Society (SRS) inclusion criteria for brace treatment as well as consensus recommendations for treatment outcome.

    METHODS: This was a systematic review that was carried out using MeSH terminology in our search protocol in PubMed, Cochrane Library, Scopus, Clinicaltrials.gov and Web of Science database between 1976 and 29th of Jan 2023. All studies that were included in this review had applied fully/partially the SRS inclusion criteria for brace wear. Outcome measures were divided into primary and secondary outcome measures.

    RESULTS: 3830 literatures were found in which 176 literatures were deemed relevant to the study once duplicates were removed and titles and abstracts were screened. Of these literatures, only 15 had fulfilled the eligibility criteria and were included in the study. 8 of the studies were Level IV studies, 5 were Level III studies and 2 studies were Level I studies (1 prospective randomised controlled trial (RCT) and 1 Quasi-RCT). The percentage of patients who avoided surgery for European braces ranged from 88 to 100%, whereas for Boston brace ranged from 70 to 94%. When treatment success was assessed based on the final Cobb angle > 45°, approximately 15% of patients treated with European braces had treatment failure. In contrast, 20-63% of patients treated with Boston brace had curves > 45° at skeletal maturity. The BrAIST study used a cut-off point of 50° to define failure of treatment and the rate of treatment failure was 28%. Curve correction was not achieved in most patients (24-51% of patients) who were treated with the Chêneau brace and its derivatives. However, none of the patients treated with Boston brace achieved curve correction.

    CONCLUSION: Boston brace and European braces were effective in the prevention of surgery. In addition, curve stabilisation was achieved in most studies. Limitation in current literature included lack of studies providing high level of evidence and lack of standardisation in terms of compliance to brace as well as multidisciplinary management of brace wear.

    Matched MeSH terms: Braces
  4. Mehdikhani M, Behtash H, Ganjavian MS, Abu Osman NA, Khalaj N
    Prosthet Orthot Int, 2014 Aug;38(4):316-20.
    PMID: 23950552 DOI: 10.1177/0309364613499063
    The Milwaukee brace is an efficient method for correcting hyperkyphosis before skeletal maturity. However, loss of correction in long-term follow-up is inevitable.
    Matched MeSH terms: Braces*
  5. Mehdikhani M, Behtash H, Ganjavian MS, Khalaj N
    J Back Musculoskelet Rehabil, 2016 Aug 10;29(3):515-9.
    PMID: 26836834 DOI: 10.3233/BMR-150651
    Hyperkyphosis with unknown reason is common in teenagers and can be corrected by orthotic management.
    Matched MeSH terms: Braces*
  6. Lee BYP, Mazelan A, Gunalan R, Albaker MZA, Saw A
    Med J Malaysia, 2020 09;75(5):510-513.
    PMID: 32918418
    INTRODUCTION: Most of the authors currently agree that congenital talipes equinovarus (CTEV) or idiopathic clubfoot can be effectively treated with the Ponseti method instead of extensive soft tissue surgery. This study was conducted to investigate whether there is a difference in the outcome between starting treatment before one month of age or after that age.

    METHODS: This is a retrospective study on babies with CTEV treated in University Malaya Medical Centre from 2013 to 2017. The 54 babies (35 boys and 19 girls) were divided into two cohorts, Group 1 that had treatment before the age of one month, and Group 2 that had treatment after one month old. The number of cast changes, rate of full correction, and rate of relapse after treatment were compared between the two groups.

    RESULTS: Of the 54 babies, with 77 CTEV treated during the period, our outcome showed that the mean number of cast change was 5.9 for Group 1 and 5.7 for Group 2. The difference was not statistically significant. All the affected feet (100%) achieved full correction. One foot in the Group 1 relapsed, while three feet in Group 2 relapsed, but the difference was also not statistically significant. All of the relapsed feet were successfully treated with repeated Ponseti method.

    CONCLUSIONS: Treating CTEV using Ponseti method starting after one month was not associated with more casting change of higher rate of relapse.

    Matched MeSH terms: Braces*
  7. Gouwanda D, Gopalai AA
    Med Eng Phys, 2015 Feb;37(2):219-25.
    PMID: 25619613 DOI: 10.1016/j.medengphy.2014.12.004
    Gait events detection allows clinicians and biomechanics researchers to determine timing of gait events, to estimate duration of stance phase and swing phase and to segment gait data. It also aids biomedical engineers to improve the design of orthoses and FES (functional electrical stimulation) systems. In recent years, researchers have resorted to using gyroscopes to determine heel-strike (HS) and toe-off (TO) events in gait cycles. However, these methods are subjected to significant delays when implemented in real-time gait monitoring devices, orthoses, and FES systems. Therefore, the work presented in this paper proposes a method that addresses these delays, to ensure real-time gait event detection. The proposed algorithm combines the use of heuristics and zero-crossing method to identify HS and TO. Experiments involving: (1) normal walking; (2) walking with knee brace; and (3) walking with ankle brace for overground walking and treadmill walking were designed to verify and validate the identified HS and TO. The performance of the proposed method was compared against the established gait detection algorithms. It was observed that the proposed method produced detection rate that was comparable to earlier reported methods and recorded reduced time delays, at an average of 100 ms.
    Matched MeSH terms: Braces*
  8. Siti Hajjar Nasir, Noraini Abu Bakar, Rosdiyana Samad
    MyJurnal
    Orthodontic fixed appliance is now considered as fashion accessory and a symbol of
    wealth. Due to overwhelming demand, 'fake' and 'real' braces services have been offered through
    social media by unqualified personnel using poor quality orthodontic brackets and cases of metal
    toxicity from using these type of braces has been reported. (Copied from article).
    Matched MeSH terms: Braces
  9. Siti Hajjar Nasir, Noraini Abu Bakar, Rosdiyana Samad
    MyJurnal
    The growing demand for orthodontic braces among Malaysian community has led to
    the development of "fake" and "real" braces. "Fake" braces refer to braces that are worn as costume
    and are not bonded to teeth hence unable to produce movement of teeth. "Real" braces refer to
    braces that are bonded to tooth structure and are able to produce tooth movement. The braces are
    bonded by unqualified practitioners with no formal dental education and they provide braces
    treatment in unlicensed premises such as hotel rooms or patients' own homes. (Copied from article).
    Matched MeSH terms: Braces
  10. Leong L, Chai SC, Howell JW, Hirth MJ
    J Hand Ther, 2023;36(2):302-315.
    PMID: 37391318 DOI: 10.1016/j.jht.2023.05.016
    BACKGROUND: The design and efficacy of orthotic intervention to non-surgically manage adult and pediatric trigger finger vary widely.

    PURPOSE: To identify types of orthoses (including relative motion), effectiveness, and outcome measurements used to non-surgically manage adult and pediatric trigger finger.

    STUDY DESIGN: Systematic review.

    METHODS: The study was undertaken according to The Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 Statement and registered with the International Prospective Register of Systematic Reviews Registry, number CRD42022322515. Two independent authors electronically and manually searched, and screened 4 databases; selected articles following pre-set eligibility criteria; assessed the quality of the evidence using the Structured Effectiveness for Quality Evaluation of Study; and extracted the data.

    RESULTS: Of the 11 articles included, 2 involved pediatric trigger finger and 9 adult trigger finger. Orthoses for pediatric trigger finger positioned finger(s), hand, and/or wrist of children in neutral extension. In adults, a single joint was immobilized by the orthosis, blocking either the metacarpophalangeal joint or the proximal or distal interphalangeal joint. All studies reported positive results with statistically significant improvements and medium to large effect size to almost every outcome measure, including the Number of Triggering Events in Ten Active Fist 1.37, Frequency of Triggering from 2.07 to 2.54, Quick Disabilities of the Arm, Shoulder and Hand Outcome Measure from 0.46 to 1.88, Visual Analogue Pain Scale from 0.92 to 2.00, and Numeric Rating Pain Scale from 0.49 to 1.31. Severity tools and patient-rated outcome measures were used with the validity and reliability of some unknown.

    CONCLUSIONS: Orthoses are effective for non-surgical management of pediatric and adult trigger finger using various orthotic options. Although used in practice, evidence for the use of relative motion orthosis is absent. High-quality studies based on sound research questions and design using reliable and valid outcome measures are needed.

    Matched MeSH terms: Braces
  11. Nor Azlida Mohd Nor, Zamros Yuzadi Mohd Yusof, Wan Nurazreena Wan Hassan, Mohd ZambriMohamed Makhbul
    Ann Dent, 2020;27(1):33-40.
    MyJurnal
    Dental quackery has been a problem for decades and is becoming a major concern in many countries, including Malaysia. Recent development of a new service offered by quacks in Malaysia is “fake braces”, which alarmed dental professionals. The fake braces appear similar to the professionally fitted orthodontic appliances comprising of archwires that are secured on brackets by coloured ligatures except they are fitted by unqualified individuals who have no formal clinical training. In addition, the orthodontic materials and dental equipment used for this illegal service were substandard and unregulated. Therefore, such fitted appliances are harmful to the teeth and oral health. Efforts to record the extent of fake braces practice and its oral health consequences have been challenging as they are marketed through the social media, and the victims were either reluctant to come forward or did not know the appropriate channel to file a complaint to the health authority. This is an expert opinion paperwith theaimsto highlight typical presentation of fake braces, modus operandi of fake braces providers, the harmful effects of fake braces on the patient’s oral health, the role of social media advertising in promoting fake braces, and the impacts to the illegal providers.
    Matched MeSH terms: Braces
  12. Kassem MM, Mohamed Nazri F
    Data Brief, 2018 Dec;21:2262-2283.
    PMID: 30555866 DOI: 10.1016/j.dib.2018.11.077
    This paper provides data and information on Beirut Arab University׳s existing old building in Lebanon. The building was primarily designed to resist gravity loads only, with no attention to seismic or lateral load effects. The data shows that there is a need to improve the conditions of the existing old building by applying new features that function as seismic capacity resistance. The first feature was applied by adding RC-shear walls to the existing building, and the second feature was by implementing concentric steel bracing at the peripheral face of the building. In this article, a set of critical parameters to identify the seismic design of buildings was associated in this data. The parameters were described in terms of dynamic properties as follows: (a) natural fundamental period, (b) mode shapes, (c) torsional irregularity, (d) stiffness and ductility, and (e) plastic hinges formation. Particularly, the estimated cost analysis of added materials plays an important role in choosing the suitable retrofitting technique for old buildings.
    Matched MeSH terms: Braces
  13. Lee W, Kyaw MO
    Malays Orthop J, 2015 Jul;9(2):26-32.
    PMID: 28435606 MyJurnal DOI: 10.5704/MOJ.1507.008
    The optimal treatment for thoracolumbar fractures (TLF) without neurological deficit remains controversial. Majority of the systematic reviews and meta-analyses have evaluated open operative approaches but have yet to compare the outcomes of minimally invasive percutaneous pedicle fixation (MIPPF) versus non-operative treatment. A retrospective cohort study was performed to compare clinical and radiological outcomes between MIPPF and conservative groups for TLF AO Type A1 to Type B2 during a 2-year follow-up period. Pre-operative plain and CT films were evaluated and decision made for short segment (non-fusion) MIPPF. Patients who refused operation were treated conservatively with three months of body cast, brace, or corset. MIPPF group showed earlier Visual Analog Score(VAS) improvement at six months post-injury (0 vs 6.0- p<0.001), as well as better functional and radiological outcomes (p<0.050) at final follow-up. Progressions of regional kyphosis (RK) were noted in both groups but there was no significant difference within and between them(p>0.050). MIPPF as a method of internal bracing can be pursued in the treatment of TLF, with larger future cohorts and RCTs being called for to support and explore new findings.
    Matched MeSH terms: Braces
  14. Yap YT, Gouwanda D, Gopalai AA, Chong YZ
    J Biomech Eng, 2023 Feb 01;145(2).
    PMID: 36082472 DOI: 10.1115/1.4055564
    Musculoskeletal modeling and simulation have been an emerging trend in human gait analysis. It allows the user to isolate certain biomechanical conditions and elucidate the dynamics of joints and muscles. This study used an open-source musculoskeletal modeling and simulation tool, opensim to investigate the biomechanical effect of knee brace. It collected gait data from thirty-eight participants and examined the gait spatio-temporal parameters, joint angles, and joint moments. Static optimization was performed to estimate the lower extremity muscle force. Statistical analysis was conducted to identify the difference between normal and braced gaits. The results demonstrated the feasibility of this method to investigate the interaction and coordination of lower extremity joints and muscles. The knee brace constrained the range of the motion of the knee during walking. It also changed the walking speed, step length, and stance-to-swing ratio. Several significant differences were found in the joint moments and muscle forces of the rectus femoris, gastrocnemius, soleus and tibialis anterior. Musculoskeletal modeling and simulation tool offers a less invasive and practical alternative to analyze human motion. It also provides a means to investigate the effect of medical devices such as knee brace, which can be potentially beneficial for the future design and development of such devices and for the derivation of future rehabilitation treatment to improve patient's gait.
    Matched MeSH terms: Braces
  15. Mortaza N, Abu Osman NA, Jamshidi AA, Razjouyan J
    PLoS One, 2013;8(5):e64308.
    PMID: 23717593 DOI: 10.1371/journal.pone.0064308
    Use of functional knee braces has been suggested to provide protection and to improve kinetic performance of the knee in Anterior cruciate ligament(ACL)-injured patients. However, many athletes might refrain from wearing the braces because of the fear of performance hindrance in the playing field. The aim of this study was to examine the effect of three functional knee brace/sleeves upon the isokinetic and functional performance of ACL-deficient and healthy subjects. Six anterior cruciate ligament deficient (29.0 ± 5.3 yrs., 175.2 ± 5.4 cm, and 73.0 ± 10.0 kg) and six healthy male subjects (27.2 ± 3.7 yrs., 176.4 ± 6.4 cm, and 70.3 ± 6.9 kg) were selected. The effect of a custom-made functional knee brace, and two neoprene knee sleeves, one with four metal supports and one without support were examined via the use of isokinetic and functional tests in four sets (non-braced,wearing functional knee brace,and wearing the sleeves). Cross-over hop and single leg vertical jump test were performed and jump height, and hop distance were recorded. Peak torque to body weight ratio and average power in two isokinetic velocities(60°.s(-1),180°.s(-1)) were recorded and the brace/sleeves effect was calculated as the changes in peak torque measured in the brace/sleeves conditions, expressed as a percentage of peak torque measured in non-braced condition. Frequency content of the isokinetic torque-time curves was also analyzed. Wilcoxon signed rank test was used to compare the measured values in four test conditions within each control and ACL-deficient group,and Mann-Whitney U test was used for the comparison between the two groups. No significant differences in peak torque, average power, torque-time curve frequency content, vertical-jump and hop measurements were found within the experimental and the non-braced conditions (p>0.05). Although the examined functional knee brace/sleeves had no significant effect on the knee muscle performance, there have been some enhancement regarding the extension peak torques and power generating capacity of the ACL-deficient subjects that could be helpful in reducing the bilateral asymmetry in these patients.
    Matched MeSH terms: Braces*
  16. Eshraghi A, Maroufi N, Sanjari MA, Saeedi H, Keyhani MR, Gholizadeh H, et al.
    Prosthet Orthot Int, 2013 Feb;37(1):76-84.
    PMID: 22751219 DOI: 10.1177/0309364612448805
    Biomechanical factors, such as spinal deformities can result in balance control disorders.
    Matched MeSH terms: Braces*
  17. Mohd Sharif NA, Goh SL, Usman J, Wan Safwani WKZ
    Phys Ther Sport, 2017 Nov;28:44-52.
    PMID: 28673759 DOI: 10.1016/j.ptsp.2017.05.001
    BACKGROUND: Knee sleeves are widely used for the symptomatic relief and subjective improvements of knee problems. To date, however, their biomechanical effects have not been well understood.

    OBJECTIVE: To determine whether knee sleeves can significantly improve the biomechanical variables for knee problems.

    METHOD: Systematic literature search was conducted on four online databases - PubMed, Web of Science, ScienceDirect and Springer Link - to find peer-reviewed and relevant scientific papers on knee sleeves published from January 2005 to January 2015. Study quality was assessed using the Structured Effectiveness Quality Evaluation Scale (SEQES).

    RESULTS: Twenty studies on knee sleeves usage identified from the search were included in the review because of their heterogeneous scope of coverage. Twelve studies found significant improvement in gait parameters (3) and functional parameters (9), while eight studies did not find any significant effects of knee sleeves usage.

    CONCLUSION: Most improvements were observed in: proprioception for healthy knees, gait and balance for osteoarthritic knees, and functional improvement of injured knees. This review suggests that knee sleeves can effect functional improvements to knee problems. However, further work is needed to confirm this hypothesis, due to the lack of homogeneity and rigor of existing studies.

    Matched MeSH terms: Braces*
  18. Lim HH, Chong CS
    Med J Malaysia, 1999 Sep;54(3):368-70.
    PMID: 11045066
    A 12 year-old Chinese schoolgirl presented with left-sided scoliosis at the age of 9 years. She has a rare defect in lipid metabolism, which is not known to be associated with spinal deformity. Her scoliotic curve deteriorated despite bracing. We report a rare occurrence of scoliosis in patient with lipodystrophy and the difficulty of using instrumented fusion in treating this condition.
    Matched MeSH terms: Braces
  19. Limpaphayom N, Sailohit P
    Malays Orthop J, 2019 Nov;13(3):28-33.
    PMID: 31890107 DOI: 10.5704/MOJ.1911.005
    Introduction: Idiopathic clubfoot or congenital talipes equinovarus (CTEV) is managed by the Ponseti method worldwide; however, the recurrence of the deformity is a challenging problem. The purpose was to review the factors associated with early recurrence of CTEV post the Ponseti method. Materials and Methods: During 2011-2016, 34 infants with 52 CTEV, who underwent the Ponseti method and a minimum follow-up period of six months, were reviewed. Twenty-two infants (65%) were male, and 18 infants (53%) had bilateral CTEV. Recurrence of CTEV was defined as a reappearance of at least one of the four components of the deformity. The association between recurrence and factors, including age, gender, bilaterality, family geography, type of principal caregiver, severity at presentation, centre where the Ponseti method was initiated, compliance to foot abduction brace (FAB), practice of stretching exercise, type of FAB, and complications of casting, were evaluated using univariate logistic regression analysis. Results: The median age at initiation of the treatment was 3.4 (IQR; 2.1-12.6) weeks. A median of six (range; 3-12) casts were required. Tenotomy was performed in 32/34 (94%) of cases. Recurrence occurred in 14/52 feet (27%) at an average follow-up period of 2.3±1.1 years. Non-compliance to FAB protocol began at an average age of 11.2±6.5 months, and significantly increased the risk of recurrence during the weaning phase [OR (95%CI)=8.4 (1.2-92.4), p=0.03]. Other factors were not associated with the recurrence. Conclusion: Non-compliance to FAB occurred early during the treatment and related to a risk of recurrence of CTEV. Physicians should encourage the parents and/or guardians to follow the protocol to decrease the risk of recurrence.
    Matched MeSH terms: Braces
  20. Khan SJ, Khan SS, Usman J, Mokhtar AH, Abu Osman NA
    Gait Posture, 2018 03;61:243-249.
    PMID: 29413792 DOI: 10.1016/j.gaitpost.2018.01.024
    OBJECTIVE: To test the hypothesis that toe-in gait (TI) will further reduce first peak (Knee Adduction Moment) KAM and decrease balance when combined with a knee brace (KB) and laterally wedged insoles (LWI) in medial knee osteoarthritis (kOA) patients.
    PARTICIPANTS: Twenty patients with bilateral symptomatic medial kOA.
    INTERVENTIONS: 4-point leverage-based KB, full-length LWI with 5° inclination and toe-in gait (TI).
    MAIN OUTCOME MEASURES: First and second peak knee adduction moment (fKAM and sKAM respectively), balance and pain.
    METHODS: The fKAM and sKAM were determined from 3-dimensional gait analysis with six randomized conditions: (1) N (without any intervention), (2) KB, (3) KB + TI, (4) LWI, (5) LWI + TI, (6) KB + LWI + TI. Balance was assessed by Biodex Balance System using three stability settings, (i) Static (ii) Moderate dynamic setting for fall risk (FR12) and (iii) High dynamic setting for fall risk (FR8).
    RESULTS: The reduction in fKAM and sKAM was greatest (19.75% and 12%) when TI was combined with KB and LWI respectively. No change in balance was observed when TI combined with KB, and LWI and when used concurrently with both the orthosis at static and FR12 conditions. Significant balance reduction was found at FR8 for KB + TI (22.22%), and KB + LWI + TI (35.71%). Pain increased significantly for KB (258%), KB + TI (305%), LWI + TI (210%) and KB + LWI + TI (316%). LWI showed no effect on pain.
    CONCLUSIONS: There is a synergistic effect of TI when combined with KB and LWI concurrently in sKAM reduction. However, the concurrent use of TI, KB and LWI decreases balance and pain as assessed on a highly dynamic platform.
    Study site: Department of Sports Medicine, University of Malaya Medical Centre (UMMC), Kuala Lumpur, Malaysia
    Matched MeSH terms: Braces*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links