Affiliations 

  • 1 National Research Institute of Malaysia
MyJurnal

Abstract

Rivers as surface water in Malaysia are recipients of effluents and wastewater and yet it is important water source for daily uses of some villagers living along the river. Endocrine disruptors such as Bisphenol A (BPA) can be found in river due to continuous discharge into it. The objectives of this research is to find out the occurrence and concentration of BPA in Sungai Langat and also to see how water quality parameters such as temperature, pH, dissolved oxygen (DO), turbidity, Total Suspended Solid (TSS), Biochemical Oxygen Demand (BOD), Chemical Oxygen Demand (COD) and ammonia nitrogen (AN) affecting the concentration of BPA. 12 stations in total including upstream to downstream of Sungai Langat and also tributary of Sungai Langat. The instrument used to find out concentration of BPA is Triple Quadrupole LC/MS. The source of BPA are mainly industrial effluents and also direct domestic discharges. The water quality parameters that will affect concentration of BPA are Ammonia Nitrogen (AN), turbidity, Biochemical Oxygen Demand (BOD), Total Suspended Solid (TSS), and Chemical Oxygen Demand (COD), Dissolved Oxygen (DO). While pH and water temperature are also factors that will affect concentration of BPA but the significance is not shown in the analysis. It can be concluded that upstream of Sungai Langat has lower concentration of BPA than downstream.