METHODS: All publications related to hepatitis B reactivation with the use of immunosuppressive therapy since 1975 were reviewed. Advice from key opinion leaders in member countries/administrative regions of Asian-Pacific Association for the study of the liver was collected and synchronized. Immunosuppressive therapy was risk-stratified according to its reported rate of hepatitis B reactivation.
RECOMMENDATIONS: We recommend the necessity to screen all patients for hepatitis B prior to the initiation of immunosuppressive therapy and to administer pre-emptive nucleos(t)ide analogues to those patients with a substantial risk of hepatitis and acute-on-chronic liver failure due to hepatitis B reactivation.
OBJECTIVE: This paper aimed to describe the development process of the COVID-19 Symptom Monitoring System (CoSMoS), which consists of a self-monitoring, algorithm-based Telegram bot and a teleconsultation system. We describe all the essential steps from the clinical perspective and our technical approach in designing, developing, and integrating the system into clinical practice during the COVID-19 pandemic as well as lessons learned from this development process.
METHODS: CoSMoS was developed in three phases: (1) requirement formation to identify clinical problems and to draft the clinical algorithm, (2) development testing iteration using the agile software development method, and (3) integration into clinical practice to design an effective clinical workflow using repeated simulations and role-playing.
RESULTS: We completed the development of CoSMoS in 19 days. In Phase 1 (ie, requirement formation), we identified three main functions: a daily automated reminder system for patients to self-check their symptoms, a safe patient risk assessment to guide patients in clinical decision making, and an active telemonitoring system with real-time phone consultations. The system architecture of CoSMoS involved five components: Telegram instant messaging, a clinician dashboard, system administration (ie, back end), a database, and development and operations infrastructure. The integration of CoSMoS into clinical practice involved the consideration of COVID-19 infectivity and patient safety.
CONCLUSIONS: This study demonstrated that developing a COVID-19 symptom monitoring system within a short time during a pandemic is feasible using the agile development method. Time factors and communication between the technical and clinical teams were the main challenges in the development process. The development process and lessons learned from this study can guide the future development of digital monitoring systems during the next pandemic, especially in developing countries.
MATERIALS AND METHODS: This was a retrospective study using computed tomography (CT) scans from 3 hospitals. Inclusion criteria were scans with 1-5 nodules of diameter ≥5 mm; exclusion criteria were poor-quality scans or those with nodules measuring <5mm in diameter. In the lesion detection phase, 2,147 nodules from 219 scans were used to develop and train the deep learning 3D-CNN to detect lesions. The 3D-CNN was validated with 235 scans (354 lesions) for sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) analysis. In the path planning phase, Bayesian optimization was used to propose possible needle trajectories for lesion biopsy while avoiding vital structures. Software-proposed needle trajectories were compared with actual biopsy path trajectories from intraprocedural CT scans in 150 patients, with a match defined as an angular deviation of <5° between the 2 trajectories.
RESULTS: The model achieved an overall AUC of 97.4% (95% CI, 96.3%-98.2%) for lesion detection, with mean sensitivity of 93.5% and mean specificity of 93.2%. Among the software-proposed needle trajectories, 85.3% were feasible, with 82% matching actual paths and similar performance between supine and prone/oblique patient orientations (P = .311). The mean angular deviation between matching trajectories was 2.30° (SD ± 1.22); the mean path deviation was 2.94 mm (SD ± 1.60).
CONCLUSIONS: Segmentation, lesion detection, and path planning for CT-guided lung biopsy using an AI-guided software showed promising results. Future integration with automated robotic systems may pave the way toward fully automated biopsy procedures.
METHODS: This cross-sectional study of women who underwent DBT and ABUS from December 2019 to March 2022 included opportunistic and targeted screening cases, as well as symptomatic women. Breast density, Breast Imaging Reporting and Data System categories and histopathology reports were collected and compared. The PPV3 (proportion of examinations with abnormal findings that resulted in a tissue diagnosis of cancer), biopsy rate (percentage of biopsies performed) and cancer detection yield (number of malignancies found by the diagnostic test given to the study sample) were calculated.
RESULTS: A total of 1089 ABUS examinations were performed (age range: 29-85 y, mean: 51.9 y). Among these were 909 screening (83.5%) and 180 diagnostic (16.5%) examinations. A total of 579 biopsies were performed on 407 patients, with a biopsy rate of 53.2%. There were 100 (9.2%) malignant lesions, 30 (5.2%) atypical/B3 lesions and 414 (71.5%) benign cases. In 9 cases (0.08%), ABUS alone detected malignancies, and in 19 cases (1.7%), DBT alone detected malignancies. The PPV3 in the screening group was 14.6%.
CONCLUSION: ABUS is useful as an adjunct to DBT in the opportunistic screening and diagnostic setting.
METHODS: We prospectively followed 100 patients (50:50 cuffed and non-cuffed PICC) and compared CRBSI rate between these groups. Daily review and similar catheter care were performed until a PICC-related complication, completion of therapy, death or defined end-of-study date necessitate removal. CRBSI was confirmed in each case by demonstrating concordance between isolates colonizing the PICC at the time of infection and from peripheral blood cultures.
RESULTS: A total of 50 cuffed PICC were placed for 1864 catheter-days. Of these, 12 patients (24%) developed infection, for which 5 patients (10%) had a CRBSI for a rate of 2.7 per 1000 catheter-days. Another 50 tunnelled non-cuffed PICCs were placed for 2057 catheter-days. Of these, 7 patients (14%) developed infection, for which 3 patients (6%) had a CRBSI. for a rate of 1.5 per 1000 catheter-days. The mean time to development of infection is 24 days in cuffed and 19 days in non-cuffed groups. The mean duration of utilization was significantly longer in non-cuffed than in cuffed group (43 days in non-cuffed vs 37 days in cuffed group, p = 0.008).
CONCLUSIONS: Cuffed PICC does not further reduce the rate of local or bloodstream infection. Tunnelled non-cuffed PICC is shown to be as effective if not better at reducing risk of CRBSI and providing longer catheter dwell time compared to cuffed PICC.
METHODS: A total of 224 patients were recruited. An optimised CT protocol was applied using 100 kV and 1 mL/kg of contrast media dosing. The image quality and radiation dose exposure of this CT protocol were compared to those of a standard 120 kV, 80 mL fixed volume protocol. The radiation dose information and CT Hounsfield units were recorded. The signal-to-noise ratio, contrast-to-noise ratio (CNR) and figure of merit (FOM) were used as comparison metrics. The images were assessed for contrast opacification and visual quality by two radiologists. The renal function, contrast media volume and cost were also evaluated.
RESULTS: The median effective dose was lowered by 16% in the optimised protocol, while the arterial phase images achieved significantly higher CNR and FOM. The radiologists' evaluation showed more than 97% absolute agreement with no significant differences in image quality. No significant differences were found in the pre- and post-CT estimated glomerular filtration rate. However, contrast media usage was significantly reduced by 1,680 mL, with an overall cost savings of USD 421 in the optimised protocol.
CONCLUSION: The optimised weight-based protocol is cost-efficient and lowers radiation dose while maintaining overall contrast enhancement and image quality.
METHODS: 220 patients underwent CT of the chest, abdomen and pelvis (CAP) using a standard FV protocol, and subsequently, a customised 1.0 mL/kg WBV protocol within one year. Both image sets were assessed for contrast enhancement using CT attenuation at selected regions-of-interest (ROIs). The visual image quality was evaluated by three radiologists using a 4-point Likert scale. Quantitative CT attenuation was correlated with the visual quality assessment to determine the HU's enhancement indicative of the image quality grades. Contrast media usage was calculated to estimate cost-savings from both protocols.
RESULTS: Mean patient age was 61 ± 14 years, and weight was 56.1 ± 8.7 kg. FV protocol produced higher contrast enhancement than WBV, p