Displaying publications 1 - 20 of 52 in total

Abstract:
Sort:
  1. Tanko P, Mohd Yusoff S, Emikpe BO, Onilude OM, Abdullateef A
    J Immunoassay Immunochem, 2021 May 04;42(3):265-284.
    PMID: 33577382 DOI: 10.1080/15321819.2020.1862862
    This study investigated dexamethasone-treatment, shedding routes, tissue antigen distribution, and pathology of caprine Brucellosis. Eighteen non-pregnant goats were randomly grouped into A, B, and C. Group A was administered dexamethasone for 7 days at 2 mg/kg before inoculating 0.5 mL B. melitensis at 107 CFU ocularly while group B was inoculated 0.5 mL B. melitensis only, and C as control negative. Blood samples, ocular, nasal, and vaginal swabs were obtained for evaluation. Three goats were sacrificed from each group at days 21 and 42 post-inoculation (pi) and selected tissues collected for PCR, histopathology, and immunohistochemistry. Brucella melitensis was detected in the ocular swabs of group A significantly higher than group B. Shedding was prolonged in group A compared to B. The overall shedding was 22.2% in group A and 9.4% in group B. The uterus of both groups A and B revealed mild inflammation and microgranuloma, extensive necrotic lesions in lymph nodes. Liver showed multifocal necrosis predominantly in group A. Lesion scoring showed significantly higher scores in A compared to B. Strong immunostaining was observed in the liver, lungs, and spleen, predominantly at day 21 pi. This study demonstrated dexamethasone prolonged shedding, tissue antigen distribution, and pathology in dexamethasone-treated goats.
    Matched MeSH terms: Antigens/immunology*
  2. Ismail T, McSharry C, Boyd G
    Respirology, 2006 May;11(3):262-8.
    PMID: 16635083
    Extrinsic allergic alveolitis (also known as hypersensitivity pneumonitis) is caused by repeated inhalation of mainly organic antigens by sensitized subjects. This induces a hypersensitivity response in the distal bronchioles and alveoli and subjects may present clinically with a variety of symptoms. The aims of this review are to describe the current concepts of the immunological response, the diverse clinical presentation of this disease, the relevant investigations and management, and areas for future studies.
    Matched MeSH terms: HLA Antigens/immunology*
  3. Lim TS, Chan SK
    Curr Pharm Des, 2016;22(43):6480-6489.
    PMID: 27669969 DOI: 10.2174/1381612822666160923111924
    BACKGROUND: Antibody phage display is highly dependent on the availability of antibody libraries. There are several forms of libraries depending mainly on the origin of the source materials. There are three major classes of libraries, mainly the naïve, immune and synthetic libraries.

    METHODS: Immune antibody libraries are designed to isolate specific and high affinity antibodies against disease antigens. The pre-exposure of the host to an infection results in the production of a skewed population of antibodies against the particular infection.

    RESULTS: This characteristic takes advantage of the in vivo editing machinery to generate bias and specific immune repertoire. The skewed but diverse repertoire of immune libraries has been adapted successfully in the generation of antibodies against a wide range of diseases.

    CONCLUSION: We envisage immune antibody libraries to play a greater role in the discovery of antibodies for diseases in the near future.

    Matched MeSH terms: Antigens/immunology
  4. Cheng HM
    Autoimmunity, 1998;27(2):99-108.
    PMID: 9583741
    Matched MeSH terms: Antigens/immunology; Autoantigens/immunology
  5. Jalalonmuhali M, Carroll RP, Tsiopelas E, Clayton P, Coates PT
    Hum Immunol, 2020 Jul;81(7):323-329.
    PMID: 32327243 DOI: 10.1016/j.humimm.2020.04.002
    BACKGROUND: Blood transfusion during the post-operative period of kidney transplantation is common as part of a life-saving procedure, especially in the event of acute blood loss. However, there have been conflicting opinions since the pre-cyclosporine era. The risk of sensitization post-transfusion remains the main limiting factor following transfusion in kidney transplant recipients. Thus, the objective of this study is to assess the development of de novo HLA-DSA, HLA-Ab and allograft rejection post blood transfusion.

    METHODOLOGY: This is a retrospective cohort study recruiting all kidney transplant recipients in South Australia from January 2010 till December 2018. Following that, the incidence of blood transfusion within one week post-operatively were traced (transfusion group). The outcomes were compared with all other transplant recipients (non-transfusion group). Recipient's demographic, donor characteristics and immunological risk profiles were obtained from the transplant unit database, while the biopsy report, history of blood transfusion, latest serum creatinine and follow-up status was gathered from the electronic medical system (OASIS). The HLA-DSA and HLA-Ab results were collected from the NOMS database. Finally, the survival data were merged with the Australia and New Zealand Dialysis and Transplant (ANZDATA) Registry for South Australia recipients graft survival.

    RESULTS: A total of 699 patients were eligible for analysis. The mean age was 50.64 ± 13.23 years old. There were more elderly (>65 years old) and females who needed transfusion. The majority had glomerulonephritis as the primary disease. There was no statistical difference in donor characteristics, cold ischemic time and immunological risk between the transfusion and non-transfusion group. There was no difference in the development of de novo HLA-DSA, HLA-Ab and rejection episodes between the group and the results were consistent in a model adjusted for all potential confounders. Median graft survival in days between the transfusion vs non-transfusion group was 1845 IQR (961,2430) and 1250 IQR (672,2013).

    CONCLUSION: Blood transfusion under strong immunosuppressive cover within a one-week post-operative period is safe with no significant association with the development of de novo HLA-DSA, HLA-Ab or clinical rejection.

    Matched MeSH terms: HLA Antigens/immunology*
  6. Jalalonmuhali M, Caroll R, Deayton S, Emery T, Humphreys I, Lim SJ, et al.
    Hum Immunol, 2020 Dec;81(12):679-684.
    PMID: 32736900 DOI: 10.1016/j.humimm.2020.07.005
    BACKGROUND: Angiotensin II type 1 receptor antibody (AT1R-Ab) is a non-HLA antibody that has been reported to cause antibody-mediated rejection and graft loss in kidney transplantation. The prevalence of positive AT1R-Ab varies between 8% and 18% in different regions. Thus, this study aims to determine the prevalence of AT1R-Ab among the Malaysian population.

    METHODOLOGY: All sera for AT1R-Ab were collected at the University Malaya Medical Centre (UMMC), Kuala Lumpur, Malaysia. The sera were centrifuged and kept refrigerated at -80 °C before being transported to the South Australian Transplantation and Immunogenetics Laboratory (SATIS). Enzyme-linked immunosorbent assay kit (One Lambda) was used for the detection of AT1R-Ab, and it was performed according to the manufacturer's instructions. The level of >17.1 U/mL was considered to be AT1R-Ab positive; 10.0-17.1 U/mL at risk, and <10.0 U/mL negative.

    RESULTS: A total of 115 samples were collected from 99 patients pre and post-kidney transplant recipients. From the pre-transplant sera (n = 68) 17.7% were positive, 35.3% were at risk and 47.0% were negative. The positive AT1R-Ab cohort were relatively younger, with a mean age of 34.7 ± 8.3 years old and statistically significant, with a p-value of 0.028. Among the sera that were tested positive, 19.0% were from the Chinese ethnicity, 6.7% from Malay and 16.7% from Indian. There was no difference in the rejection episodes, persistent or de novo HLA-DSA, and graft function between the group (AT1R-Ab negative vs AT1R-Ab at risk and positive) and the results were consistent in a model adjusted for all potential confounders.

    CONCLUSION: The prevalence of positive (>17.1 U/mL) pre-transplant AT1R-Ab was 17.7% and 35.3% were at risk (10.0-17.1 U/mL) in our pre-transplant cohort.

    Matched MeSH terms: HLA-DQ Antigens/immunology
  7. Anand K, Vadivalagan C, Joseph JS, Singh SK, Gulati M, Shahbaaz M, et al.
    Chem Biol Interact, 2021 Aug 01;344:109497.
    PMID: 33991505 DOI: 10.1016/j.cbi.2021.109497
    Extracellular vesicles like exosomes are important therapeutic tactics for treating COVID -19. By utilizing convalescent plasma derived exosomes (CPExo) from COVID-19 recovered persistence could accelerate the treatment strategies in the current state of affairs. Adequate literature has shown that administering the exosome to the in vivo system could be beneficial and could target the pathogens in an effective and precise manner. In this hypothesis we highlight the CPExo instead of convalescent plasma (CP), perhaps to dispense of exosomes are gratified and it's more effectively acquired immune response conferral through antibodies. COVID-19 convalescent plasma has billions of exosomes and it has aptitudes to carry molecular constituents like proteins, lipids, RNA and DNA, etc. Moreover, exosomes are capable of recognizing antigens with adequate sensitivity and specificity. Many of these derivatives could trigger an immune modulation into the cells and act as an epigenetic inheritor response to target pathogens through RNAs. COIVID-19 resistance activated plasma-derived exosomes are either responsible for the effects of plasma beyond the contained immune antibodies or could be inhibitory. The proposed hypothesis suggests that preselecting the plasma-derived antibodies and RNAs merged exosomes would be an optimized therapeutic tactic for COVID-19 patients. We suggest that, the CPExo has a multi-potential effect for treatment efficacy by acting as immunotherapeutic, drug carrier, and diagnostic target with noncoding genetic materials as a biomarker.
    Matched MeSH terms: Antigens/immunology
  8. Hajar CGN, Zulkafli Z, Md Riffin NS, Tuan Mohammad TH, Safuan S, Nelson BR, et al.
    Transfus Apher Sci, 2020 Apr;59(2):102651.
    PMID: 31606336 DOI: 10.1016/j.transci.2019.09.004
    BACKGROUND: Human neutrophil antigens (HNAs) are implicated in several clinical disorders and their allelic variations have been reported for many populations. This new study was aimed to report the genotype and alleles frequencies of HNA-1, -3, -4 and -5 loci in Malays, Chinese and Indians in Peninsular Malaysia.

    METHODS: A total of 222 blood samples were collected from healthy, unrelated Malay, Chinese and Indian individuals. Their HNA-1, -3 and -4 and HNA-5 loci were genotyped using polymerase chain reaction-sequence specific primer (PCR-SSP) or PCR-restriction fragment length polymorphism (RFLP) assays.

    RESULTS: All HNA loci are polymorphic, except for HNA -4. Geneotypes HNA-1a/1b, -3a/3b and -4a/4a were observed most frequently at these three loci in all three ethnic groups. In contrast, HNA-5a/5b and -5a/5a were observed as the predominant genotypes in Malays vs. Chinese and Indians, respectively. The Malays, Chinese and Indians shared HNA -3a (0.505-0.527), HNA -4a (1.000) and -5a (0.676-0.854) as the most frequent alleles. However, HNA-1a was found to be the most common in Malays (0.506) and Chinese (0.504) and HNA-1b for Indians (0.525).

    CONCLUSION: Combined with HNA data that have been published for Malay subethnic and Orang Asli groups, this study provides the first fully comprehensive HNA dataset for populations to be found in Peninsular Malaysia. Overall, our findings provide further evidence of genetic complexity in the region. This now publicly available HNA dataset can be used as a reliable reference source for improving medical outcomes.

    Matched MeSH terms: Antigens/immunology*
  9. Kurup VP, Kelly KJ, Turjanmaa K, Alenius H, Reunala T, Palosuo T, et al.
    J Allergy Clin Immunol, 1993 Jun;91(6):1128-34.
    PMID: 8509575
    BACKGROUND: Patients with latex sensitivity and latex antigens from the United States and Finland, two countries where allergic reactions to latex have been widely reported, were evaluated to determine the spectrum of immune responses.

    METHODS: Sera from 27 patients from Finland and 18 from the United States with latex allergy and control sera from nonsensitive individuals were studied for latex-specific IgE antibodies. Four antigen preparations were used: two extracted from gloves and one each extracted from rubber tree sap from Malaysia and India. All 45 patients had skin prick test results that were positive to latex antigens, and all sera were evaluated by enzyme-linked immunosorbent assay (ELISA) with the various antigens.

    RESULTS: There were considerable differences in the reactivity of patient sera with the different antigens. Only 50% of the sera from patients with latex allergy from Finland demonstrated significant levels of IgE to latex as determined by enzyme-linked immunosorbent assay. These patients showed more reactivity with rubber tree sap antigens than with glove antigens. However, 72% of the patients from the United States demonstrated antibodies to latex, and no marked differences were noted between the antigen extracts.

    CONCLUSIONS: The results indicate that reagents such as rubber tree sap, which contain multiple clinically significant antigenic components, should be included in evaluation of latex allergy and that differences in patient populations may result in serologic variances.

    Matched MeSH terms: Antigens/immunology*
  10. Yap SF, Wong NW, Goh KL
    Malays J Pathol, 1994 Jun;16(1):57-62.
    PMID: 16329577
    The relationship between serum Hepatitis B virus DNA (HBV-DNA) and the Hepatitis B e-antigen/ anti-Hepatitis Be (HBeAg/anti-HBe) serological status in Malaysians was studied. 212 cases of asymptomatic HBV carriers were recruited for this study. 92 cases were positive for the HBeAg at the point of recruitment. 85 (92.4%) of these patients tested positive for HBV-DNA, of whom 55 (64.7%) had levels over 100pg/ml of serum. Three of the remaining 7 HBeAg positive cases who were negative for HBV-DNA subsequently seroconverted. The other 4 cases remained negative for HBV-DNA for periods of 6-12 months. Out of 113 cases who were anti-HBe positive, 12 (10.6%) gave a positive HBV-DNA result. 2 of these 12 patients were recent seroconverters; the remaining cases had transiently increased viral replicative activity which later subsided. 7 out of the 212 carriers were in the e-window period; all 7 tested negative for HBV-DNA. Our data confirm a high frequency of HBV-DNA in HBeAg positive carriers and a negative correlation between HBV-DNA and anti-HBe. An atypical profile of anti-HBe associated with HBV-DNA was observed in 10.6% of the carriers. An inverse relationship between serum HBV-DNA levels and age was also observed.
    Matched MeSH terms: Hepatitis B e Antigens/immunology*
  11. Syed Azim SM, Muhamad NA, Leong CF, Hussin NH
    Malays J Pathol, 2015 Aug;37(2):109-14.
    PMID: 26277667 MyJurnal
    Antibody screening is important for the antenatal screening and pre-transfusion tests. This study aimed to compare the MUT/Mur kodecytesAbtectcell III (CSL Abtectcell III) red cell antibody screening kit with DiaMed ID-Dia Cell I-II-III Asia that was then used in our laboratory. In this study, 125 samples were randomly chosen, with 67 samples of known antibody specificities and 58 samples identified as negative for antibody, as the negative control. Concordant negative results were obtained in 57 out of 58 antibody negative samples. Concordant antibody positive results with both reagents were seen in 49 out of 67 samples. There were 18 discrepant results of antibody screening with CSL Abtetcell III (16/18 for vMNS antibodies). The sensitivity and specificity for CSL Abtectcell III were 73.0% and 98.3% respectively. In conclusion, the CSL Abtectcell III reagent would be an acceptable alternative for screening of red cell alloantibodies. It was able to detect all the clinically significant alloantibodies.
    Matched MeSH terms: Blood Group Antigens/immunology*
  12. Sukumaran KD, Joo OK
    Med J Malaysia, 1990 Jun;45(2):144-7.
    PMID: 2152019
    The aim of this study was to determine the frequency and specificity of HLA-A and B antibodies in multiparous mothers in the Malaysian population. 1,100 maternal serum samples obtained during normal childbirth were screened against a panel of 100 lymphocytes with known HLA antigen types for HLA antibodies by the complement dependent lymphocyte microcytotoxicity dye exclusion test. From the total number of 1,100 samples of maternal serum that were screened for HLA antibodies only 205 specimens (18.6%) tested positive for antibodies. The percentage of maternal sera which contained HLA-B specificities (10.6%) were significantly higher than those which contained HLA-A specificities (3.0%). Sixty maternal serum samples (5.5%) had high enough titres to be utilised as tissue typing reagents. Thirty nine maternal serum samples (3.5%) contained monospecific HLA antibodies. In this study the most common monospecific HLA antibodies characterised included the following specificities: A2, B5, B17 and B40. Malaysian multiparous mothers of gravida 3, 4 and 5 had a higher frequency for producing HLA-antibodies.
    Matched MeSH terms: HLA-A Antigens/immunology*; HLA-B Antigens/immunology*
  13. Lee CE, Sri Ponnampalavanar S, Syed Omar SF, Mahadeva S, Ong LY, Kamarulzaman A
    Ann Acad Med Singap, 2011 Oct;40(10):448-53.
    PMID: 22206053 DOI: 10.47102/annals-acadmedsg.V40N10p448
    INTRODUCTION: Dried blood spot (DBS) collection is an appealing alternative to whole blood or plasma sampling, as it has technical and economic advantages over the latter.

    MATERIALS AND METHODS: A prospective cross-sectional study was conducted at a Malaysian tertiary referral hospital from November 2009 to March 2010. One hundred and fifty paired specimens of DBS and plasma were analysed by the standard assays for HIV Ag/Ab, HBsAg, anti-HBS and anti-HCV, separately (total 600 paired specimens). DBS sample titres were then compared to the results of plasma testing, which was used as the gold standard.

    RESULTS: For the HIV Ag/Ab assay with a cut-off point of 0.35 Relative Light Units (RLUs), the sensitivity and specificity were both 100%. For the HBsAg assay, the sensitivity was 96.5% and the specificity was 97.8%, with a cut-off point of 1.72 RLUs. Sensitivity for the anti-HBs test was 74.2% and the specificity was 86.9%, using a cut-off point of 0.635 RLUs. For the anti-HCV assay, the sensitivity was 97.3% and the specificity was 100%, with a cut-off point of 0.10 RLUs.

    CONCLUSION: DBS is an ideal choice to be used as a screening tool for the detection of HIV, Hepatitis B and Hepatitis C virus infections. However, different cut-off values need to be used for the validation of test positivity in DBS samples because the small amount of blood in the DBS specimens leads to lower assay titres.
    Matched MeSH terms: Hepatitis B Surface Antigens/immunology; HIV Antigens/immunology; Hepatitis C Antigens/immunology
  14. Gopinath SC, Tang TH, Citartan M, Chen Y, Lakshmipriya T
    Biosens Bioelectron, 2014 Jul 15;57:292-302.
    PMID: 24607580 DOI: 10.1016/j.bios.2014.02.029
    Sensing applications can be used to report biomolecular interactions in order to elucidate the functions of molecules. The use of an analyte and a ligand is a common set-up in sensor development. For several decades, antibodies have been considered to be potential analytes or ligands for development of so-called "immunosensors." In an immunosensor, formation of the complex between antibody and antigen transduces the signal, which is measurable in various ways (e.g., both labeled and label-free based detection). Success of an immunosensor depends on various factors, including surface functionalization, antibody orientation, density of the antibody on the sensor platform, and configuration of the immunosensor. Careful optimization of these factors can generate clear-cut results for any immunosensor. Herein, current aspects, involved in the generated immunosensors, are discussed.
    Matched MeSH terms: Antigens/immunology
  15. Cheang HK, Wong HT, Ho SC, Chew KS, Lee WS
    Singapore Med J, 2013 Apr;54(4):224-6.
    PMID: 23624451
    INTRODUCTION: This study aimed to assess the immune response in infants who received the three-shot hepatitis B vaccine in Malaysia.

    METHODS: Consecutive infants born between March 2002 and April 2010 who received three doses of hepatitis B vaccine at a community clinic in Malaysia were enrolled in the study. Screening for hepatitis B surface antigen (HBsAg) and antibody against HBsAg (anti-HBs) was performed after the completion of primary immunisation, at approximately one year of age.

    RESULTS: A total of 572 infants (median age 9.3 ± 2.7 months; range 6.3-48 months) were screened for immune response to hepatitis B vaccination - 553 (96.7%) infants had adequate levels of anti-HBs (≥ 10 IU/L). Of the 440 mothers whose HBsAg status was known, 14 (3.2%) were positive for HBsAg. None of the 14 infants who were born to HBsAg-positive mothers were positive for HBsAg, and all but one infant had anti-HBs level ≥ 10 IU/L. Gender, gestational age and maternal HBsAg status were not found to significantly affect the subsequent immune response in infants following vaccination.

    CONCLUSION: The proportion of Malaysian mothers who are positive for HBsAg remains high. The three-shot hepatitis B vaccine, given as part of universal vaccination against hepatitis B, provides adequate anti-HBs in the vast majority of infants in a community setting in Malaysia.
    Matched MeSH terms: Hepatitis B Surface Antigens/immunology
  16. Fadilah SA, Mohd-Razif MI, Seery ZA, Nor-Rafeah T, Wan-Fariza WJ, Habsah A, et al.
    Transfus Apher Sci, 2013 Dec;49(3):583-9.
    PMID: 24012241 DOI: 10.1016/j.transci.2013.07.032
    We examined the donor factors that may affect the yield of peripheral blood stem cell (PBSC) mobilized from healthy donors. Pre-apheresis PB-CD34(+) cell count was the only factor that correlated with PBSC yield. Leukocyte count (LC) and monocyte count (MC) correlated with PB-CD34(+) cell. Male gender and PB-CD34(+) cell count of at least 87.1/μL and 69.8/μL on day-4 and -5 of G-CSF were associated with the ability to harvest at least 5×10(6)/kg CD34(+) cells after one apheresis. We concluded that gender and PB-CD34(+) cell count are important predictors of PBSC yield. LC and MC may serve as surrogate markers for estimating the PB-CD34(+) cell count.
    Matched MeSH terms: HLA Antigens/immunology*
  17. Schmidt-Ullrich R, Wallach DF, Lightholder J
    J. Exp. Med., 1979 Jul 01;150(1):86-99.
    PMID: 87490
    Purified schizonts (6--10 nuclei) and membranes of schizont-infected erythrocytes from the Malaysian and Philippine strain of Plasmodium knowlesi are analyzed immunochemically using immunoglobulin of rhesus monkey hyperimmune sera against schizonts and of sera from naturally immune monkeys. The anti-schizont Ig identifies less than 20 immune components in Triton X-100-solubilized schizonts and membranes of infected cells. Of these antigens, 9 (component 1, 3, 4, 5, 6, 10, 11, 18, and 20) are common to parasites and membranes of infected erythrocytes, and 12 (2A,B, 6, 8, 9, 12, 13p, 14, 16A,B, 19 A,Bp, 21, 22p, and 23) are predominantly found in the parasite; 4 components (13i, 19A,Bi, 22A, B, and 24) are unique to the membrane of infected erythrocytes. Only three parasite-specific components (1, 13, and 19) are exposed on the surface of parasitized erythrocytes as revealed by both lactoperoxidase-catalyzed radioiodination and extensive absorption of anti-schizont Ig using intact infected erythrocytes. Two plasmodium-specific antigens (1 and 13) on the surface of infected erythrocytes are recognized by sera of rhesus monkeys rendered naturally immune against P. knowlesi infections and, therefore, represent antigens in vivo. Analyses of schizonts and membranes of parasitized erythrocytes of the two different strains of P. knowlesi yields only some minor quantitative, but no qualitative differences when analyzed with both types of antisera. Importantly, components 1 and 13 appear identical in both strains.
    Matched MeSH terms: Antigens/immunology*
  18. Jalalonmuhali M, Ng KP, Mohd Shariff NH, Lee YW, Wong AH, Gan CC, et al.
    Transplant Proc, 2020 05 21;52(6):1718-1722.
    PMID: 32448671 DOI: 10.1016/j.transproceed.2020.02.140
    The shortage of deceased donors led to an increase of living related renal transplant performed in the presence of donor-specific antibodies (DSAs) or ABO incompatibilities. There are various desensitization protocols that have been proposed. Here, we describe the outcome of these sensitized patients. This is a prospective cohort study recruiting all kidney transplant recipients from August 2016 until June 2018. Deceased donations, ABO incompatible patients, and sensitized patients who were not prescribed on our desensitization protocol were excluded. Recipients were screened for the presence of HLA-antibodies 1 month before transplant. Those with positive DSA will undergo flow cytometry (risk stratification). We are using a protocol that consisted of intravenous rituximab 200 mg (day -14), intravenous antithymocyte globulin 5mg/kg (day 0-4), plasma exchange post transplant for patients with mean fluorescent intensity (MFI) < 3000, and negative flow cytometry. Those patients with MFI ≥ 3000 or positive flow cytometry need extra cycles pretransplant. A total of 40 patients were recruited, and 20 were sensitized patients. Among the sensitized group 4 of 20 had flow cytometry crossmatch positive, while all had preformed HLA-DSA. A total of 8 of 20 had class I HLA-DSA, 11 of 20 had class II HLA-DSA, and 1of 20 was positive for both class I and II HLA-DSA. Mean immunodominant MFI was 2133.4 (standard deviation [SD], 4451.24) and 1383.7 (SD, 2979.02) for class I and class II, respectively. At 1 year, mean serum creatinine was 108.90 (SD, 25.95) and 118.42 (SD, 31.68) in sensitized and unsensitized patients, respectively. One of 20 unsensitized patients had Banff 1B rejection at 3 months, and there was no significant rejection in sensitized patients at 6 months and 1 year. There was no difference in the occurrence of de novo HLA-DSA between the groups. Desensitization protocols may help to overcome incompatibility barriers in living donor renal transplant. The combination of low-dose rituximab, antithymocyte globulin, and judicious use of plasma exchange has worked well for our cohort.
    Matched MeSH terms: HLA Antigens/immunology*
  19. Chin CF, Ler LW, Choong YS, Ong EB, Ismail A, Tye GJ, et al.
    J Microbiol Methods, 2016 Jan;120:6-14.
    PMID: 26581498 DOI: 10.1016/j.mimet.2015.11.007
    Antibody phage display panning involves the enrichment of antibodies against specific targets by affinity. In recent years, several new methods for panning have been introduced to accommodate the growing application of antibody phage display. The present work is concerned with the application of streptavidin mass spectrometry immunoassay (MSIA™) Disposable Automation Research Tips (D.A.R.T's®) for antibody phage display. The system was initially designed to isolate antigens by affinity selection for mass spectrometry analysis. The streptavidin MSIA™ D.A.R.T's® system allows for easy attachment of biotinylated target antigens on the solid surface for presentation to the phage library. As proof-of-concept, a domain antibody library was passed through the tips attached with the Hemolysin E antigen. After binding and washing, the bound phages were eluted via standard acid dissociation and the phages were rescued for subsequent panning rounds. Polyclonal enrichment was observed for three rounds of panning with five monoclonal domain antibodies identified. The proposed method allows for a convenient, rapid and semi-automated alternative to conventional antibody panning strategies.
    Matched MeSH terms: Antigens/immunology
  20. Ch'ng ACW, Konthur Z, Lim TS
    Methods Enzymol, 2020;630:159-178.
    PMID: 31931984 DOI: 10.1016/bs.mie.2019.10.023
    Directed evolution is a proven approach to fine tune or modify biomolecules for various applications ranging from research to industry. The process of evolution requires methods that are capable of not only generating genetic diversity but also to distinguish the variants of desired characteristics. One method that is synonymous with directed evolution of proteins is phage display. Here, we present a protocol describing the application of magnetic nanoparticles coupled with a processor to carry out the identification of monoclonal antibodies (mAbs) from a diverse antibody library via phage display. Target antigens are coupled to magnetic nanoparticles as the solid phase for the isolation of the binding mAbs via affinity. A gradual enrichment in clones would result in increasing ELISA readouts with increasing rounds of panning. During monoclonal level analysis, positivity can be deduced with comparison to background and controls. The biopanning process can also be adopted for the directed evolution of enzymes, scaffold proteins or even peptides.
    Matched MeSH terms: Antigens/immunology
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links