Displaying publications 1 - 20 of 31 in total

Abstract:
Sort:
  1. Manikam J, Mahadeva S, Goh KL, Abdullah BJ
    Hepatogastroenterology, 2009 Jan-Feb;56(89):227-30.
    PMID: 19453063
    Spontaneous rupture and hemorrhage is a devastating complication of hepatocellular carcinoma (HCC). Results from current therapeutic modalities remain varied. Recent development of percutaneous radiofrequency ablation (RFA) in the management of this condition has shown promise. We describe 2 cases of ruptured HCC in which nonoperative, percutaneous radio frequency ablation (RFA) was successful in achieving hemostasis. The advantageous of RFA over other interventional techniques in the management of ruptured HCC are discussed.
    Matched MeSH terms: Catheter Ablation/methods*
  2. Givehchi S, Wong YH, Yeong CH, Abdullah BJJ
    Minim Invasive Ther Allied Technol, 2018 Apr;27(2):81-89.
    PMID: 28612670 DOI: 10.1080/13645706.2017.1330757
    PURPOSE: To investigate the effect of radiofrequency ablation (RFA) electrode trajectory on complete tumor ablation using computational simulation.

    MATERIAL AND METHODS: The RFA of a spherical tumor of 2.0 cm diameter along with 0.5 cm clinical safety margin was simulated using Finite Element Analysis software. A total of 86 points inside one-eighth of the tumor volume along the axial, sagittal and coronal planes were selected as the target sites for electrode-tip placement. The angle of the electrode insertion in both craniocaudal and orbital planes ranged from -90° to +90° with 30° increment. The RFA electrode was simulated to pass through the target site at different angles in combination of both craniocaudal and orbital planes before being advanced to the edge of the tumor.

    RESULTS: Complete tumor ablation was observed whenever the electrode-tip penetrated through the epicenter of the tumor regardless of the angles of electrode insertion in both craniocaudal and orbital planes. Complete tumor ablation can also be achieved by placing the electrode-tip at several optimal sites and angles.

    CONCLUSIONS: Identification of the tumor epicenter on the central slice of the axial images is essential to enhance the success rate of complete tumor ablation during RFA procedures.

    Matched MeSH terms: Catheter Ablation/methods*
  3. Sridhar GS, Watson T, Han CK, Ahmad WA
    Arq. Bras. Cardiol., 2015 Aug;105(2):202-4.
    PMID: 26352181 DOI: 10.5935/abc.20150100
    Matched MeSH terms: Catheter Ablation/adverse effects; Catheter Ablation/methods
  4. Ch'ng LS, Tazuddin EEM, Young B, Ali AFM
    BJR Case Rep, 2016;2(2):20150306.
    PMID: 30363592 DOI: 10.1259/bjrcr.20150306
    Radiofrequency ablation (RFA) of a hepatic tumour is an established treatment option with an acceptable complication rate. Formation of a pseudoaneurysm after RFA of liver metastasis is an uncommon complication. We report the case of a 69-year-old female patient developing a hepatic pseudoaneurysm after RFA of liver metastasis. On a follow-up CT scan 6 weeks later, there was spontaneous resolution of the pseudoaneurysm. Hepatic pseudoaneurysms are usually treated owing to the risk of rupture. Invasive procedures or conservative management of an asymptomatic hepatic pseudoaneurysm is still the subject of debate. The spontaneous resolution of a hepatic pseudoaneurysm in our patient suggests that an asymptomatic pseudoaneurysm maybe observed for resolution instead of being treated at presentation.
    Matched MeSH terms: Catheter Ablation
  5. Phillips KP, Romanov A, Artemenko S, Folkeringa RJ, Szili-Torok T, Senatore G, et al.
    Europace, 2020 02 01;22(2):225-231.
    PMID: 31665276 DOI: 10.1093/europace/euz286
    AIMS: Clinical practice guidelines do not recommend discontinuation of long-term oral anticoagulation in patients with a high stroke risk after catheter ablation for atrial fibrillation (AF). Left atrial appendage closure (LAAC) with Watchman has emerged as an alternative to long-term anticoagulation for patients accepting of the procedural risks. We report on the long-term outcomes of combining catheter ablation procedures for AF and LAAC from multicentre registries.

    METHODS AND RESULTS: Data were pooled from two prospective, real-world Watchman LAAC registries running in parallel in Europe/Middle-East/Russia (EWOLUTION) and Asia/Australia (WASP) between 2013 and 2015. Of the 1140 patients, 142 subjects at 11 centres underwent a concomitant AF ablation and LAAC procedure. The mean CHA2DS2-VASc score was 3.4 ± 1.4 and HAS-BLED score 1.5 ± 0.9. Successful LAAC was achieved in 99.3% of patients. The 30-day device and/or procedure-related serious adverse event rate was 2.1%. After a mean follow-up time of 726 ± 91 days, 92% of patients remained off oral anticoagulation. The rates of the composite endpoint of ischaemic stroke/transient ischaemic attack/systemic thromboembolism were 1.09 per 100 patient-years (100-PY); and for non-procedural major bleeding were 1.09 per 100-PY. These represent relative reductions of 84% and 70% vs. expected rates per risk scores.

    CONCLUSION: The long-term outcomes from these international, multicentre registries show efficacy for all-cause stroke prevention and a significant reduction in late bleeding events in a population of high stroke risk post-ablation patients who have been withdrawn from oral anticoagulation.

    Matched MeSH terms: Catheter Ablation*
  6. Nori J, Gill MK, Meattini I, Delli Paoli C, Abdulcadir D, Vanzi E, et al.
    Biomed Res Int, 2018;2018:9141746.
    PMID: 29992167 DOI: 10.1155/2018/9141746
    Background and Objectives: Breast-conserving surgery represents the standard of care for the treatment of small breast cancers. However, there is a population of patients who cannot undergo the standard surgical procedures due to several reasons such as age, performance status, or comorbidity. Our aim was to investigate the feasibility and safety of percutaneous US-guided laser ablation for unresectable unifocal breast cancer (BC).

    Methods: Between December 2012 and March 2017, 12 consecutive patients underwent percutaneous US-guided laser ablation as radical treatment of primary inoperable unifocal BC.

    Results: At median follow-up of 28.5 months (range 6-51), no residual disease or progression occurred; the overall success rate for complete tumor ablation was therefore 100%. No significant operative side effects were observed, with only 2 (13.3%) experiencing slight to mild pain during the procedure, and all patients complained of a mild dull aching pain in the first week after procedure.

    Conclusions: Laser ablation promises to be a safe and feasible approach in those patients who are not eligible to the standard surgical approach. However, longer follow-up results and larger studies are strongly needed.

    Matched MeSH terms: Catheter Ablation
  7. Adam N, Lim SS, Ananda V, Chan SP
    Singapore Med J, 2010 Jul;51(7):e129-32.
    PMID: 20730389
    Vasoactive intestinal peptide-producing tumour (VIPoma) or Verner-Morrison syndrome is a very rare neuroendocrine tumour. It occurs in less than ten percent of all pancreatic islet cell tumours, and about 70 percent to 80 percent of these tumours originate from the pancreas. Diagnosis is characteristically delayed. The first-line treatment is surgical. It may be curative in forty percent of patients with benign and non-metastatic disease. Palliative surgery is indicated in extensive disease, followed by conventional somatostatin analogue (octreotide) therapy. Somatostatin analogues improve hormone-mediated symptoms, reduce tumour bulk and prevent local and systemic effects. We present a female patient with VIPoma syndrome, which had metastasised to the liver at diagnosis. The patient underwent palliative Whipple procedure and subsequent cytoreductive radiofrequency ablations to her liver metastases. Unfortunately, after symptomatic improvement for three years, her disease progressed. Currently, she is on daily octreotide, achieving partial control of her symptoms.
    Matched MeSH terms: Catheter Ablation/methods
  8. Hairol AO, Affirul CA, Azlanudin A, Zamri Z, Razman J, Choi SY
    Clin Ter, 2017 Jan-Feb;168(1):e5-e7.
    PMID: 28240755 DOI: 10.7417/CT.2017.1974
    Radiofrequency ablation (RFA) has evolved to become the treatment of choice for non-resectable recurrent colorectal liver metastasis. It is however, not without complications. Portal vein thrombosis following RFA is rare but can be fatal to the outcome of the patient. Here, we present a case of a 66-year-old man who developed portal vein thrombosis following RFA. CT scan revealed a left portal vein thrombosis. This case report highlights the challenges and multimodal treatment of portal vein thrombosis following Radiofrequency ablation (RFA) in a cirrhotic patient.
    Matched MeSH terms: Catheter Ablation/adverse effects*
  9. Zucchelli G, Chun KRJ, Khelae SK, Földesi C, Kueffer FJ, van Bragt KA, et al.
    J Interv Card Electrophysiol, 2023 Apr;66(3):711-722.
    PMID: 36331681 DOI: 10.1007/s10840-022-01388-6
    BACKGROUND: Cryoballoon ablation (CBA) is an effective first-line treatment for symptomatic atrial fibrillation (AF), as recently demonstrated by three randomized trials. This sub-analysis of the Cryo Global Registry aims to examine current clinical practices of first-line CBA.

    METHODS: AF patients treated with first-line CBA were compared to CBA in antiarrhythmic drug (AAD)-refractory patients at 12 months. Efficacy was examined using time-to-first atrial arrhythmia recurrence following a 90-day blanking period. Healthcare utilization was evaluated by repeat ablations and hospitalizations. Disease burden was examined by assessing quality of life (QOL) and patients' reporting of symptoms.

    RESULTS: Of 1394 patients, 433 (31.1%) were treated with first-line CBA, which was more frequent in high-volume centers. Serious procedure-related adverse event rates were similar. Efficacy at 12 months was higher in the first-line group (87.8 vs. 81.6%, HRunadj 0.64 (95% CI 0.47-0.88); p 

    Matched MeSH terms: Catheter Ablation*
  10. Acharya UR, Faust O, Ciaccio EJ, Koh JEW, Oh SL, Tan RS, et al.
    Comput Methods Programs Biomed, 2019 Jul;175:163-178.
    PMID: 31104705 DOI: 10.1016/j.cmpb.2019.04.018
    BACKGROUND AND OBJECTIVE: Complex fractionated atrial electrograms (CFAE) may contain information concerning the electrophysiological substrate of atrial fibrillation (AF); therefore they are of interest to guide catheter ablation treatment of AF. Electrogram signals are shaped by activation events, which are dynamical in nature. This makes it difficult to establish those signal properties that can provide insight into the ablation site location. Nonlinear measures may improve information. To test this hypothesis, we used nonlinear measures to analyze CFAE.

    METHODS: CFAE from several atrial sites, recorded for a duration of 16 s, were acquired from 10 patients with persistent and 9 patients with paroxysmal AF. These signals were appraised using non-overlapping windows of 1-, 2- and 4-s durations. The resulting data sets were analyzed with Recurrence Plots (RP) and Recurrence Quantification Analysis (RQA). The data was also quantified via entropy measures.

    RESULTS: RQA exhibited unique plots for persistent versus paroxysmal AF. Similar patterns were observed to be repeated throughout the RPs. Trends were consistent for signal segments of 1 and 2 s as well as 4 s in duration. This was suggestive that the underlying signal generation process is also repetitive, and that repetitiveness can be detected even in 1-s sequences. The results also showed that most entropy metrics exhibited higher measurement values (closer to equilibrium) for persistent AF data. It was also found that Determinism (DET), Trapping Time (TT), and Modified Multiscale Entropy (MMSE), extracted from signals that were acquired from locations at the posterior atrial free wall, are highly discriminative of persistent versus paroxysmal AF data.

    CONCLUSIONS: Short data sequences are sufficient to provide information to discern persistent versus paroxysmal AF data with a significant difference, and can be useful to detect repeating patterns of atrial activation.

    Matched MeSH terms: Catheter Ablation*
  11. Ang D, Lee YY, Clarke JO, Lynch K, Guillaume A, Onyimba F, et al.
    Ann N Y Acad Sci, 2020 12;1481(1):154-169.
    PMID: 32428279 DOI: 10.1111/nyas.14369
    Gastroesophageal reflux disease (GERD) is a common condition characterized by troublesome symptoms or esophageal mucosal lesions attributed to excessive esophageal acid exposure. Various pathophysiological mechanisms account for GERD, including impaired esophageal peristalsis and anatomical or physiological defects at the esophagogastric junction (EGJ). Endoscopy identifies GERD complications and detects potential alternative diagnoses. However, if symptoms persist despite proton pump inhibitor therapy, functional esophageal tests are useful to characterize reflux burden and define the symptom association profile. Ambulatory pH or pH-impedance monitoring measures the 24-h acid exposure time, which remains the most reproducible reflux metric and predicts response to antireflux therapy. Apart from identifying peristaltic dysfunction, esophageal high-resolution manometry defines the morphology and contractile vigor (EGJ-CI) of the EGJ. Novel metrics obtained from pH-impedance monitoring include the postreflux swallow-induced peristaltic wave index and mean nocturnal baseline impedance, which augment the diagnostic value of pH-impedance testing. Mucosal impedance can also be recorded using a probe inserted through a gastroscope, or a novel balloon catheter with arrays of impedance electrodes inserted following sedated endoscopy. The latest developments in functional esophageal tests define the GERD phenotype based on pathogenesis, reflux exposure, structural or motility disorders, and symptom burden, facilitating appropriate treatment.
    Matched MeSH terms: Catheter Ablation*
  12. Harjit S
    Med J Malaysia, 2005 Jul;60 Suppl B:108-11.
    PMID: 16108189
    Matched MeSH terms: Catheter Ablation
  13. Abdullah BJ, Yeong CH, Goh KL, Yoong BK, Ho GF, Yim CC, et al.
    Eur Radiol, 2015 Jan;25(1):246-57.
    PMID: 25189152 DOI: 10.1007/s00330-014-3391-7
    OBJECTIVE: This study aimed to assess the technical success, radiation dose, safety and performance level of liver thermal ablation using a computed tomography (CT)-guided robotic positioning system.

    METHODS: Radiofrequency and microwave ablation of liver tumours were performed on 20 patients (40 lesions) with the assistance of a CT-guided robotic positioning system. The accuracy of probe placement, number of readjustments and total radiation dose to each patient were recorded. The performance level was evaluated on a five-point scale (5-1: excellent-poor). The radiation doses were compared against 30 patients with 48 lesions (control) treated without robotic assistance.

    RESULTS: Thermal ablation was successfully completed in 20 patients with 40 lesions and confirmed on multiphasic contrast-enhanced CT. No procedure related complications were noted in this study. The average number of needle readjustment was 0.8 ± 0.8. The total CT dose (DLP) for the entire robotic assisted thermal ablation was 1382 ± 536 mGy.cm, while the CT fluoroscopic dose (DLP) per lesion was 352 ± 228 mGy.cm. There was no statistically significant (p > 0.05) dose reduction found between the robotic-assisted versus the conventional method.

    CONCLUSION: This study revealed that robotic-assisted planning and needle placement appears to be safe, with high accuracy and a comparable radiation dose to patients.

    KEY POINTS: • Clinical experience on liver thermal ablation using CT-guided robotic system is reported. • The technical success, radiation dose, safety and performance level were assessed. • Thermal ablations were successfully performed, with an average performance score of 4.4/5.0. • Robotic-assisted ablation can potentially increase capabilities of less skilled interventional radiologists. • Cost-effectiveness needs to be proven in further studies.

    Matched MeSH terms: Catheter Ablation/methods*
  14. Abdullah BJ, Yeong CH, Goh KL, Yoong BK, Ho GF, Yim CC, et al.
    Eur Radiol, 2014 Jan;24(1):79-85.
    PMID: 23928933 DOI: 10.1007/s00330-013-2979-7
    OBJECTIVE: Computed tomography (CT)-compatible robots, both commercial and research-based, have been developed with the intention of increasing the accuracy of needle placement and potentially improving the outcomes of therapies in addition to reducing clinical staff and patient exposure to radiation during CT fluoroscopy. In the case of highly inaccessible lesions that require multiple plane angulations, robotically assisted needles may improve biopsy access and targeted drug delivery therapy by avoidance of the straight line path of normal linear needles.

    METHODS: We report our preliminary experience of performing radiofrequency ablation of the liver using a robotic-assisted CT guidance system on 11 patients (17 lesions).

    RESULTS/CONCLUSION: Robotic-assisted planning and needle placement appears to have high accuracy, is technically easier than the non-robotic-assisted procedure, and involves a significantly lower radiation dose to both patient and support staff.

    KEY POINTS: • An early experience of robotic-assisted radiofrequency ablation is reported • Robotic-assisted RFA improves accuracy of hepatic lesion targeting • Robotic-assisted RFA makes the procedure technically easier with significant lower radiation dose.

    Matched MeSH terms: Catheter Ablation/methods*
  15. Alwi M, Kandavello G, Choo KK, Aziz BA, Samion H, Latiff HA
    Cardiol Young, 2005 Apr;15(2):141-7.
    PMID: 15845156
    Some patients with pulmonary atresia with an intact ventricular septum, mild to moderate right ventricular hypoplasia, and a patent infundibulum remain duct dependent on the flow of blood through the arterial duct despite adequate relief of the obstruction within the right ventricular outflow tract. The objective of our study was to review the risk factors for stenting of the patent arterial duct, or construction of a Blalock-Taussig shunt, in the patients with pulmonary atresia and an intact ventricular septum who remain duct-dependent following radiofrequency valvotomy and dilation of the imperforate pulmonary valve. We reviewed the data from 53 patients seen between November 1995 and December 2001. Of the 47 patients who survived, 6 required stenting of the patent arterial duct, while 4 needed construction of a modified Blalock-Taussig shunt to augment the flow of blood to the lungs at a mean of 7 plus or minus 5.7 days following the initial intervention. The remaining 37 patients required no additional procedures. We compared the findings in these two groups. The mean diameter of the tricuspid valve in the patients requiring early reintervention was 8.5 plus or minus 3.7 millimetres, giving a Z-score of -1.1 plus or minus 1.47, whilst those in the group without early reintervention had values of 10.7 plus or minus 2.2 millimetres, giving a Z-score of -0.58 plus or minus 1.18 (p equal to 0.003). No statistically significant differences were found in right ventricular morphology, McGoon ratio, or residual obstruction across the right ventricular outflow tract after decompression of the right ventricle. The diameter of the tricuspid valve, therefore, appears to be the only factor predicting the need for augmentation of flow of blood to the lungs. As just over one-fifth of our survivors required such augmentation, we hypothesize that stenting of the patent arterial duct may be performed as an integral part of primary transcatheter therapy in patients with pulmonary atresia and intact ventricular septum who have moderate right ventricular hypoplasia and a small tricuspid valve.
    Matched MeSH terms: Catheter Ablation*
  16. Kumar SK, Oon OK, Horgan P, Leen E
    Malays J Med Sci, 2015 Nov;22(6):58-62.
    PMID: 28223887
    Radiofrequency ablation is one of the more established forms of local treatment in patients with unresectable tumours, including colorectal hepatic metastases. Complications associated with this method of intervention include thermal and mechanical injuries, including vascular insults resulting in haemorrhage or pseudoaneurysm formation. This is the first case demonstrating the detection of post-ablation acute pseudoaneurysm formation identified on the table using contrast-enhanced ultrasound (CEUS) and the subsequent successful management.
    Matched MeSH terms: Catheter Ablation
  17. Mittal S
    Heart Rhythm, 2008 Jun;5(6 Suppl):S64-7.
    PMID: 18456205 DOI: 10.1016/j.hrthm.2008.03.023
    Catheter ablation has come to play an important therapeutic role in the management of some patients with ventricular arrhythmias. An important advance in catheter ablation of ventricular tachycardia (VT) has been the development of three-dimensional catheter-based mapping systems, which permit identification of the tachycardia circuit and facilitate a strategy for catheter ablation. As a result, patients who suffer from "focal" forms of VT have been identified. This can have implications with respect to underlying arrhythmia mechanism, patient prognosis, and therapeutic strategies. The article reviews some insights learned from catheter ablation of focal forms of VT.
    Matched MeSH terms: Catheter Ablation/methods*
  18. Loh KB, Bux SI, Abdullah BJ, Raja Mokhtar RA, Mohamed R
    Korean J Radiol, 2012 Sep-Oct;13(5):643-7.
    PMID: 22977334 DOI: 10.3348/kjr.2012.13.5.643
    Local treatment for hepatocellular carcinoma (HCC) has been widely used in clinical practice due to its minimal invasiveness and high rate of cure. Percutaneous radiofrequency ablation (RFA) is widely used because its treatment effectiveness. However, some serious complications can arise from percutaneous RFA. We present here a rare case of hemorrhagic cardiac tamponade secondary to an anterior cardiac vein (right marginal vein) injury during RFA for treatment of HCC.
    Matched MeSH terms: Catheter Ablation*