Displaying publications 1 - 20 of 40 in total

Abstract:
Sort:
  1. Chua KB, Mustafa B, Abdul Wahab AH, Chem YK, Khairul AH, Kumarasamy V, et al.
    Malays J Pathol, 2011 Jun;33(1):13-20.
    PMID: 21874746
    A prospective study was carried out to evaluate the sensitivity of dengue NS1 antigen-capture ELISA in comparison with dengue virus isolation, conventional RT-PCR and real-time RT-PCR for laboratory confirmation of acute dengue based on single-acute serum samples. Four primary healthcare centres were involved to recruit patients with clinical diagnosis of dengue illness. Patient's demographic, epidemiological and clinical information were collected on a standardized data entry form and 5 ml of venous blood was collected upon consent. In the laboratory, six types of laboratory tests were performed on each of the collected acute serum sample. Of the 558 acute serum samples collected from 558 patients with clinical diagnosis of dengue from mid-August 2006 to March 2009, 174 serum samples were tested positive by the dengue NS1 antigen-capture ELISA, 77 by virus isolation, 92 by RT-PCR and 112 by real-time RT-PCR. A total of 190 serum samples were tested positive by either one or a combination of the four methods whereas, only 59 serum samples were tested positive by all four methods. Thus, based on single-acute serum samples, 190 of the 558 patients (34.1%) were laboratory-confirmed acute dengue. The overall test sensitivity was 91.6%, 40.5%, 48.4% and 58.9% for dengue NS1 antigen-capture ELISA, virus isolation, conventional RT-PCR and real-time RT-PCR respectively. Statistically, dengue NS1 antigen-capture ELISA was the most sensitive and virus isolation was the least sensitive test for the laboratory confirmation of acute dengue based on single-acute serum specimens. Real-time RT-PCR was significantly more sensitive than the conventional RT-PCR.
    Matched MeSH terms: Dengue/blood*
  2. Teoh BT, Sam SS, Tan KK, Johari J, Abd-Jamil J, Hooi PS, et al.
    Sci Rep, 2016 06 09;6:27663.
    PMID: 27278716 DOI: 10.1038/srep27663
    Timely and accurate dengue diagnosis is important for differential diagnosis and immediate implementation of appropriate disease control measures. In this study, we compared the usefulness and applicability of NS1 RDT (NS1 Ag Strip) and qRT-PCR tests in complementing the IgM ELISA for dengue diagnosis on single serum specimen (n = 375). The NS1 Ag Strip and qRT-PCR showed a fair concordance (κ = 0.207, p = 0.001). While the NS1 Ag Strip showed higher positivity than qRT-PCR for acute (97.8% vs. 84.8%) and post-acute samples (94.8% vs. 71.8%) of primary infection, qRT-PCR showed higher positivity for acute (58.1% vs. 48.4%) and post-acute (50.0% vs.41.4%) samples in secondary infection. IgM ELISA showed higher positivity in samples from secondary dengue (74.2-94.8%) than in those from primary dengue (21.7-64.1%). More primary dengue samples showed positive with combined NS1 Ag Strip/IgM ELISA (99.0% vs. 92.8%) whereas more secondary samples showed positive with combined qRT-PCR/IgM ELISA (99.4% vs. 96.2%). Combined NS1 Ag Strip/IgM ELISA is a suitable combination tests for timely and accurate dengue diagnosis on single serum specimen. If complemented with qRT-PCR, combined NS1 Ag Strip/IgM ELISA would improve detection of secondary dengue samples.
    Matched MeSH terms: Dengue/blood*
  3. Lau YL, Lai MY, Teoh BT, Abd-Jamil J, Johari J, Sam SS, et al.
    PLoS One, 2015;10(9):e0138694.
    PMID: 26384248 DOI: 10.1371/journal.pone.0138694
    Dengue is usually diagnosed by isolation of the virus, serology or molecular diagnostic methods. Several commercial kits for the diagnosis of dengue are existing, but concerns have arisen regarding to the affordability and performance characteristics of these kits. Hence, the loop-mediated isothermal amplification (LAMP) is potentially ideal to be used especially in resource limited environments. Serum was collected from healthy donors and patients diagnosed with dengue infection. RNA extracted from the serum samples were tested by reverse-transcription-LAMP assay developed based on 3'-NCR gene sequences for DENV 1-4. Results were interpreted by a turbidity meter in real time or visually at the end of the assay. Sensitivity and specificity of RT-LAMP results were calculated and compared to qRT-PCR and ELISA. RT-LAMP is highly sensitive with the detection limit of 10 RNA copies for all serotypes. Dengue virus RNA was detected in all positive samples using RT-LAMP and none of the negative samples within 30-45 minutes. With continuing efforts in the optimization of this assay, RT-LAMP may provide a simple and reliable test for detecting DENV in areas where dengue is prevalent.
    Matched MeSH terms: Dengue/blood
  4. Jahanshahi P, Zalnezhad E, Sekaran SD, Adikan FR
    Sci Rep, 2014 Jan 24;4:3851.
    PMID: 24458089 DOI: 10.1038/srep03851
    Surface plasmon resonance (SPR) is a medical diagnosis technique with high sensitivity and specificity. In this research, a new method based on SPR is proposed for rapid, 10-minute detection of the anti-dengue virus in human serum samples. This novel technique, known as rapid immunoglobulin M (IgM)-based dengue diagnostic test, can be utilized quickly and easily at the point of care. Four dengue virus serotypes were used as ligands on a biochip. According to the results, a serum volume of only 1 μl from a dengue patient (as a minimized volume) is required to indicate SPR angle variation to determine the ratio of each dengue serotype in samples with 83-93% sensitivity and 100% specificity.
    Matched MeSH terms: Dengue/blood
  5. Dhanoa A, Hassan SS, Jahan NK, Reidpath DD, Fatt QK, Ahmad MP, et al.
    Infect Dis Poverty, 2018 Jan 16;7(1):1.
    PMID: 29335021 DOI: 10.1186/s40249-017-0384-1
    BACKGROUND: The frequency and magnitude of dengue epidemics continue to increase exponentially in Malaysia, with a shift in the age range predominance toward adults and an expansion to rural areas. Despite this, information pertaining to the extent of transmission of dengue virus (DENV) in the rural community is lacking. This community-based pilot study was conducted to establish DENV seroprevalence amongst healthy adults in a rural district in Southern Malaysia, and to identify influencing factors.

    METHODS: In this study undertaken between April and May 2015, a total of 277 adult participants were recruited from households across three localities in the Sungai Segamat subdistrict in Segamat district. Sera were tested for immunoglobulin G (IgG) (Panbio® Dengue Indirect IgG ELISA/high-titer capture) and immunoglobulin M (IgM) (Panbio®) antibodies. The plaque reduction neutralization test (PRNT) was conducted on random samples of IgG-positive sera for further confirmation. Medical history and a recall of previous history of dengue were collected through interviews, whereas sociodemographic information was obtained from an existing database.

    RESULTS: The overall seroprevalence for DENV infection was 86.6% (240/277) (95% CI: 83-91%). Serological evidence of recent infection (IgM/high-titer capture IgG) was noted in 11.2% (31/277) of participants, whereas there was evidence of past infection in 75.5% (209/277) of participants (indirect IgG minus recent infections). The PRNT assay showed that the detected antibodies were indeed specific to DENV. The multivariate analysis showed that the older age group was significantly associated with past DENV infections. Seropositivity increased with age; 48.5% in the age group of <25 years to more than 85% in age group of >45 years (P 

    Matched MeSH terms: Dengue/blood
  6. Wong WR, Krupin O, Sekaran SD, Mahamd Adikan FR, Berini P
    Anal Chem, 2014 Feb 4;86(3):1735-43.
    PMID: 24410440 DOI: 10.1021/ac403539k
    We present a compact, cost-effective, label-free, real-time biosensor based on long-range surface plasmon polariton (LRSPP) gold (Au) waveguides for the detection of dengue-specific immunoglobulin M (IgM) antibody, and we demonstrate detection in actual patient blood plasma samples. Two surface functionalization approaches are proposed and demonstrated: a dengue virus serotype 2 (DENV-2) functionalized surface to capture dengue-specific IgM antibody in blood plasma and the reverse, a blood plasma functionalized surface to capture DENV-2. The results obtained via these two surface functionalization approaches are comparable to, or of greater quality, than those collected by conventional IgM antibody capture enzyme linked immunosorbent assay (MAC-ELISA). Our second functionalization approach was found to minimize nonspecific binding, thus improving the sensitivity and accuracy of the test. We also demonstrate reuse of the biosensors by regenerating the sensing surface down to the virus (or antibody) level or down to the bare Au.
    Matched MeSH terms: Dengue/blood*
  7. Mohamad Zamberi Z, Zakaria Z, Abdul Aziz AT, Heng BS, Zaid M, Chong CL, et al.
    PMID: 25566870 DOI: 10.1186/s12952-014-0020-6
    Dengue is a major public health problem in many tropical and sub-tropical countries. Vascular leakage and shock are identified as the major causes of deaths in patients with severe dengue. Studies have suggested the potential role of Fc gamma receptors I (FcγRI) in the pathogenesis of dengue. We hypothesized that the circulating level of Fcγ receptor I could potentially be used as an indicator in assisting early diagnosis of severe dengue.
    Matched MeSH terms: Dengue/blood*
  8. Kumarasamy V, Wahab AH, Chua SK, Hassan Z, Chem YK, Mohamad M, et al.
    J Virol Methods, 2007 Mar;140(1-2):75-9.
    PMID: 17140671
    A commercial dengue NS1 antigen-capture ELISA was evaluated to demonstrate its potential application for early laboratory diagnosis of acute dengue virus infection. Dengue virus NS1 antigen was detected in 199 of 213 acute serum samples from patients with laboratory confirmation of acute dengue virus infection but none of the 354 healthy blood donors' serum specimens. The dengue NS1 antigen-capture ELISA gave an overall sensitivity of 93.4% (199/213) and a specificity of 100% (354/354). The sensitivity was significantly higher in acute primary dengue (97.3%) than in acute secondary dengue (70.0%). The positive predictive value of the dengue NS1 antigen-capture ELISA was 100% and negative predictive value was 97.3%. Comparatively, virus isolation gave an overall positive isolation rate of 68.1% with a positive isolation rate of 73.9 and 31.0% for acute primary dengue and acute secondary dengue, respectively. Molecular detection of dengue RNA by RT-PCR gave an overall positive detection rate of 66.7% with a detection rate of 65.2 and 75.9% for acute primary dengue and acute secondary dengue, respectively. The results indicate that the commercial dengue NS1 antigen-capture ELISA may be superior to virus isolation and RT-PCR for the laboratory diagnosis of acute dengue infection based on a single serum sample.
    Matched MeSH terms: Dengue/blood*
  9. Chen WS, Wong CH, Cillekens L
    Med J Malaysia, 2003 Mar;58(1):142-3.
    PMID: 14556343
    Matched MeSH terms: Dengue/blood*
  10. Thayan R, Huat TL, See LL, Khairullah NS, Yusof R, Devi S
    PMID: 19323035
    We determined the differential expression levels of proteins in peripheral blood mononuclear cells of patients with dengue fever (DF) and dengue hemorrhagic fever (DHF). Proteins were subjected to two-dimensional electrophoresis, mass spectrometry and Western blot analysis. We identified 8 proteins that were 2-fold or more up-regulated in patients compared to healthy control, three of which, aldolase, thioredoxin peroxidase and alpha tubulin, were related to dengue infection. Both thioredoxin peroxidase and alpha tubulin were over-expressed 4.9 and 3.3 times respectively in DHF compared to DF patients while aldolase was up-regulated 2.2 times in DF compared to DHF patients. Alpha tubulin and thioredoxin peroxidase have the potential to be utilized as biomarkers for DHF.
    Matched MeSH terms: Dengue/blood; Severe Dengue/blood
  11. Lam SK, Devine PL
    Clin Diagn Virol, 1998 May 1;10(1):75-81.
    PMID: 9646004
    Rapid diagnosis of dengue infection is essential to patient management and disease control. The development of a rapid (5 min) immunochromatographic test and a 2 h commercial capture enzyme linked immunosorbent assay (ELISA) for anti-dengue IgM and IgG antibodies may lead to more rapid and accurate testing in peripheral health settings and diagnostic laboratories.
    Matched MeSH terms: Dengue/blood*
  12. Kit Lam S, Lan Ew C, Mitchell JL, Cuzzubbo AJ, Devine PL
    Clin Diagn Lab Immunol, 2000 Sep;7(5):850-2.
    PMID: 10973469
    A commercially available enzyme-linked immunosorbent assay (ELISA) (PanBio Dengue Screening ELISA) that utilized both immunoglobulin M (IgM) and IgG capture in the same microtiter well for the diagnosis of dengue infection was evaluated. Sensitivity in primary and secondary dengue was 95%, while specificity was 94%.
    Matched MeSH terms: Dengue/blood
  13. Willeam Peter SS, Hassan SS, Khei Tan VP, Ngim CF, Azreen Adnan NA, Pong LY, et al.
    Vector Borne Zoonotic Dis, 2019 07;19(7):549-552.
    PMID: 30668248 DOI: 10.1089/vbz.2018.2379
    Background:
    There is an escalation of frequency and magnitude of dengue epidemics in Malaysia, with a concomitant increase in patient hospitalization. Prolonged hospitalization (PH) due to dengue virus (DENV) infections causes considerable socioeconomic burden. Early identification of patients needing PH could optimize resource consumption and reduce health care costs. This study aims to identify clinicopathological factors present on admission that are associated with PH among patients with DENV infections.
    Methods:
    This study was conducted in a tertiary referral hospital in Southern Malaysia. Relevant clinical and laboratory data upon admission were retrieved from medical records of 253 consecutive DENV nonstructural protein 1 (NS1) antigen and PCR-positive hospitalized patients. The DENV serotype present in each patient was determined. Patients were stratified based on duration of hospital stay (<4 vs. ≥4 days). Data were analyzed using IBM® SPSS® 25.0. Multivariate logistic regression was performed to examine the association between PH and admission parameters.
    Results:
    Of 253 DENV hospitalized patients, 95 (37.5%) had PH (≥4 days). The mean duration of hospital stay was 3.43 ± 2.085 days (median = 3 days, interquartile range = 7 days). Diabetes mellitus (adjusted odds ratio [AOR] = 6.261, 95% confidence interval [CI] = 2.130-18.406, p = 0.001), DENV-2 serotype (AOR = 2.581, 95% CI = 1.179-5.650, p = 0.018), duration of fever ≤4 days (AOR = 2.423, 95% CI = 0.872-6.734, p = 0.09), and a shorter preadmission fever duration (AOR = 0.679, 95% CI = 0.481-0.957, p = 0.027) were independently associated with PH. However, PH was not found to be associated with symptoms on admission, secondary DENV infections or platelet count, hematocrit, or liver enzyme levels on admission.
    Conclusions:
    Early identification of these factors at presentation may alert clinicians to anticipate and recognize challenges in treating such patients, leading to more focused management plans that may shorten the duration of hospitalization.
    Matched MeSH terms: Dengue/blood
  14. Gherardin T
    Aust Fam Physician, 2000 Mar;29(3):259.
    PMID: 10785992
    Shirley is a 42 year old woman who has rung you 5 days after returning from a 3 week resort holiday in Malaysia and Thailand. You saw her before her trip and administered a hepatitis A vaccine and advised her that she did not require anti malarial drugs as she was only going to large cities and beach resorts. She says she has had a high fever, headache and body aches for several days and that she feels exhausted, but is well enough to come to the surgery. When you see her later that morning, she looks fairly well, although she is moving rather gingerly. She says she has been resting, is drinking lots of fluids, has some anorexia, but no other significant symptoms. Examination reveals a temperature of 38 degrees C and she has a fine morbilliform rash on her body, limbs and neck. There are no other abnormal findings.
    Matched MeSH terms: Dengue/blood
  15. Mohamed Ismail NA, Wan Abd Rahim WE, Salleh SA, Neoh HM, Jamal R, Jamil MA
    ScientificWorldJournal, 2014;2014:436975.
    PMID: 25587564 DOI: 10.1155/2014/436975
    Malaysia a dengue endemic country with dengue infections in pregnancy on the rise. The present study was aimed at determining dengue seroprevalence (IgG or IgM) during pregnancy and its neonatal transmission in dengue seropositive women.
    Matched MeSH terms: Dengue/blood
  16. Tan LH, Lum LC, Omar SF, Kan FK
    J Clin Virol, 2012 Sep;55(1):79-82.
    PMID: 22789140 DOI: 10.1016/j.jcv.2012.06.005
    Hemophagocytic syndrome is a potentially fatal disorder. It is being increasingly reported but remained under-recognized in dengue. Most reported cases were in association with plasma leakage and shock but multi-organ impairment was also observed. We describe the time-lines of 6 cases of confirmed dengue with varying severities of hemophagocytosis. All had persistent fever, cytopenia and elevated transaminases with markedly elevated ferritin levels during and beyond the plasma leakage phase. Acute renal failure and central nervous system manifestation were observed in two patients. Morphological hemophagocytosis was demonstrated in three patients. All survivors showed clinical and biochemical resolution of hemophagocytosis indicating its transient nature. Persistence of fever and cytopenia together with multi-organ dysfunction, out of proportion to and beyond the plasma leakage phase should prompt clinicians to consider this phenomenon.
    Matched MeSH terms: Dengue/blood
  17. Darwish NT, Sekaran SD, Alias Y, Khor SM
    J Pharm Biomed Anal, 2018 Feb 05;149:591-602.
    PMID: 29197806 DOI: 10.1016/j.jpba.2017.11.064
    The sharp increase in incidence of dengue infection has necessitated the development of methods for the rapid diagnosis of this deadly disease. Here we report the design and development of a reliable, sensitive, and specific optical immunosensor for the detection of the dengue nonstructural protein 1 (NS1) biomarker in clinical samples obtained during early stages of infection. The present optical NS1 immunosensor comprises a biosensing surface consisting of specific monoclonal NS1 antibody for immunofluorescence-based NS1 antigen determination using fluorescein isothiocyanate (FITC) conjugated to IgG antibody. The linear range of the optical immunosensor was from 15-500ngmL-1, with coefficient of determination (R2) of 0.92, high reproducibility (the relative standard deviation obtained was 2%), good stability for 21days at 4°C, and low detection limit (LOD) at 15ngmL-1. Furthermore, the optical immunosensor was capable of detecting NS1 analytes in plasma specimens from patients infected with the dengue virus, with low cross-reaction with plasma specimens containing the Japanese encephalitis virus (JEV) and Zika virus. No studies have been performed on the reproducibility and cross-reactivity regarding NS1 specificity, which is thus a limitation for optical NS1 immunosensors. In contrast, the present study addressed these limitations carefully where these two important experiments were conducted to showcase the robustness of our newly developed optical-based fluorescence immunosensor, which can be practically used for direct NS1 determination in any untreated clinical sample.
    Matched MeSH terms: Dengue/blood
  18. Fang R, Sinniah M, Kuen LS
    Malays J Pathol, 1992 Dec;14(2):117-20.
    PMID: 1304624
    Dengue fever/Dengue haemorrhagic fever (DF/DHF) has been a public health problem in Malaysia with an endemic level of about 7 per 100,000 population per year. In 1990, Malaysia experienced its most severe outbreak of DF/DHF with a record total of 5,590 cases referred to the Division of Virology, Institute for Medical Research (IMR). Of these, 1,880 were confirmed serologically to be DF/DHF. The conventional serological procedure, the Haemagglutination Inhibition (HI) test, for the diagnosis of DF/DHF is cumbersome and causes delay in diagnosis. Another problem associated with the HI test has been that it has often been difficult to obtain a second convalescent serum sample for an accurate diagnosis. This has raised an urgent need to establish a "rapid" test for diagnosis of DF/DHF. As such the authors recently carried out an evaluation of a newly available commercial rapid test, namely, the Dengue Blot Assay (Diagnostic Biotechnology Singapore Pte Ltd). The test is intended for use in laboratory confirmation of dengue virus infection. The evaluation was to determine if the test could be utilised as a routine laboratory test and to establish its sensitivity and specificity. Over 400 samples were tested against the Dengue Blot Assay. Results were checked against an in-house Dengue IgM ELISA and HI assay. Preliminary results indicate that the sensitivity and specificity of the Dengue Blot is satisfactory. Our results also indicate that the Dengue Blot has a useful role to play in a routine laboratory especially since it provides rapid results on single serum samples thereby reducing the workload in a busy diagnostic laboratory.
    Matched MeSH terms: Dengue/blood
  19. Lum LC, Thong MK, Cheah YK, Lam SK
    Ann Trop Paediatr, 1995 Dec;15(4):335-9.
    PMID: 8687212 DOI: 10.1080/02724936.1995.11747794
    In dengue shock syndrome, an acute increase in capillary permeability results in leakage of plasma into the interstitial space. Pleural effusion is commonly seen in dengue shock syndrome. We report three cases of dengue-associated adult respiratory distress syndrome (ARDS) in children, in all of whom dengue haemorrhagic fever, presenting with grade 3 or grade 4 dengue shock syndrome with disseminated intravascular coagulopathy, was confirmed. The criteria for the diagnosis of ARDS were based on the expanded definition of ARDS by Murray et al. Treatment consisted of fluid resuscitation, correction of coagulopathy and mechanical ventilation. All three children had multi-organ impairment, but it was more severe in the two who died. The one survivor was well at discharge.
    Matched MeSH terms: Dengue/blood
  20. Norlijah O, Khamisah AN, Kamarul A, Mangalam S
    Med J Malaysia, 2006 Mar;61(1):22-7.
    PMID: 16708730 MyJurnal
    Prospective evaluation of repeated standard tourniquet testing as a diagnostic indicator of dengue infection was done. Included were patients admitted to a children's hospital in Kuala Lumpur on a clinical suspicion of dengue infection based on the World Health Organization (WHO) criteria. A standard method of tourniquet was performed on 79 patients on a daily basis following admission. subjects and negative in the remaining 14 subjects. Fifty-eight subjects were serologically confirmed cases, 4 indeterminate and the remaining 17 subjects had negative serology. For diagnostic classification, 13 had dengue fever, 49 with dengue haemmorhagic fever (DHF) while 17 had non-dengue infection. The sensitivity and specificity of the tourniquet test was 82.8% and 23.5% respectively. The positive predictive value (PPV) was 78.7% while the negative predictive value (NPV) was 28.6%. In addition, the tourniquet test aided in the diagnosis of one-fifth of patients with DHF, who presented with a positive tourniquet test as the only bleeding manifestation. It seems that in a hospital setting, the tourniquet test adds little to the diagnosis of dengue infection/DHF. A positive tourniquet test, repeatedly performed, was found clinically useful as a preliminary screening test in dengue infection as recommended by WHO. However, it was not very specific and had a high false positive rate.
    Matched MeSH terms: Severe Dengue/blood