METHOD: A cross-sectional study was conducted among 205 normal hearing adult participants with an age range between 25 and 54 years old. Hearing analysis with extended high-frequency pure-tone audiometry (PTA) and high-frequency DPOAE was carried out for all eligible participants. High-frequency presbycusis was considered to be present when the impairment of more than 25 dB occurs at higher than 8 kHz frequencies on both ears.
RESULTS: Prevalence of high-frequency presbycusis using extended PTA was 31.7 (95% CI: 25.3, 38.1) and using high-frequency DPOAE was 57.4 (95% CI: 50.7, 64.4). The sensitivity and specificity of high-frequency DPOAE in detecting high-frequency presbycusis were 72.3 and 49.3% respectively with positive predictive value of 39.8% and negative predictive value of 79.3%. The association between age and high-frequency presbycusis was significant based on high-frequency DPOAE (p = 0.029).
CONCLUSIONS: The prevalence of high-frequency hearing loss is higher with increasing in age. High-frequency DPOAE may be used as a screening tool followed by confirmation using extended PTA. The early detection of presbycusis is important so that measures can be taken to prevent more severe problems developing.
METHODS: Secondary analysis was carried out on data collected by the Grand Challenge Project among older adults aged ≥65 years from Selangor. Data on sociodemographic information, medical history, cognitive function and functional performance were obtained through face-to-face interviews using standardized questionnaires. Visual acuity was measured using the Early Treatment Diabetic Retinopathy Study (ETDRS) chart while hearing was assessed using pure-tone audiometry. Descriptive analysis was used to measure the prevalence of the impairments, and logistic regression analysis was used to identify the risk factors.
RESULTS: The prevalence of dual sensory impairment and hearing impairment were at 10.5% and 76.2% respectively. Multivariate logistic regression analysis revealed that participants with lower cognitive scores were associated with dual sensory impairment (odds ratio, 0.90; 95% confidence interval, 0.83-0.98), while smoking was found associated with hearing impairment (odds ratio, 6.58; 95% confidence interval, 1.51-28.65).
CONCLUSION: Dual sensory impairment is common among older adults in Selangor. The association between dual sensory impairment and cognitive function suggests the need to have visual and hearing screening on older adults for early detection particularly those at risk of cognitive impairment. The prevalence of hearing impairment was reported high among older adults and smokers appeared to be at higher risk of the impairment. Geriatr Gerontol Int 2020; 20: 911-916.
Methods: A community-based participatory research method was utilized. Two focus group discussions (FGDs) were conducted in Malaysian sign language (BIM) with a total of 10 DHH individuals. Respondents were recruited using purposive sampling. Video-recordings were transcribed and analyzed using a thematic approach.
Results: Two themes emerged: (I) challenges and scepticism of the healthcare system; and (II) features of the mHealth app. Respondents expressed fears and concerns about accessing healthcare services, and stressed on the need for sign language interpreters. There were also concerns about data privacy and security. With regard to app features, the majority preferred videos instead of text to convey information about their disease and medication, due to their lower literacy levels.
Conclusions: For an mHealth app to be effective, app designers must ensure the app is individualised according to the cultural and linguistic diversity of the target audience. Pharmacists should also educate patients on the potential benefits of the app in terms of assisting patients with their medicine-taking.
METHODS: Using cross sectional research approach, data were collected and some 46 out of 87 questionnaires distributed to caregivers attending UNHS programs at selected public hospitals were usable for analysis (response rate of 52.8%). Partial Least Squares Method (PLS) algorithm and bootstrapping technique were employed to test the hypotheses of the study.
RESULTS: R square value is 0.205, and it implies that exogenous latent variables explained 21% of the variance of the endogenous latent variable. This value indicates moderate and acceptable level of R-squared values. Findings from PLS structural model evaluation revealed that anxiety has no significant influence (β = -0.091, t = 0.753, p > 0.10) on caregivers' awareness; but perceived attitude has significant effect (β = -0.444, t = 3.434, p loss. Moreover, socio-economic situation of the caregivers may have contributed to their failure to honor UNHS screening appointments as some of them may need to work to earn a living while some may perceive it a waste of time honoring such appointments. Non-significant relationship between anxiety and caregivers' awareness may be due to religious beliefs of caregivers. Limitations and suggestions were discussed.
METHODS: We searched 3 major databases, i.e., PubMed, Embase and Lippincott Williams & Wilkins Journals@Ovid, for studies published up until 1May 2013 without language restrictions. All study designs were included in this review. The studies were identified and retrieved by two independent authors.
RESULTS: Of 118 titles scanned, 14 duplicates were removed, and a total of 13 abstracts from all three databases were identified for full-text retrieval. From the full text, eight articles met the inclusion criteria for this systematic review. These articles showed acceptable quality based on our scoring system. Most of the studies indicated that temporary threshold shifts were much lower when subjects were exposed to a noise level of 85 dBA or lower.
CONCLUSIONS: There were more threshold shifts in subjects adopting 90 dBA compared with 85 dBA. These temporary threshold shifts may progress to permanent shifts over time. Action curtailing noise exposure among employees would be taken earlier on adoption of 85 dBA as the permissible exposure limit, and hence prevalence of noise-induced hearing loss may be reduced.