Displaying publications 1 - 20 of 186 in total

Abstract:
Sort:
  1. Arvin B, Prepageran N, Raman R
    Indian J Otolaryngol Head Neck Surg, 2013 Dec;65(Suppl 3):480-4.
    PMID: 24427701 DOI: 10.1007/s12070-011-0356-x
    The objective of this study is to determine whether presbycusis occurs much earlier than previously believed if the high frequency (above 8 kHz) are included. Tertiary referral center (a teaching University). This is a cross-sectional observational study. Healthy adults from 20 to 49 years of age who had essentially normal hearing were included into the study. They were subjected to high frequency pure tone audiometry (until 16 kHz). Participants were grouped based on age ranges of 10 years (e.g., 20-29, 30-39, and 40-49) and the presence of symmetrical high frequency sensor neural hearing loss were documented. There is a significant presence of symmetrical high frequency sensor neural hearing loss (not attributed to any known risk factors) as early as from the age group of 40 to 49 years. Seven of 43 participants (16%) from age group of 20 to 29 years and 12 of 24 participants (50%) from age group of 30 to 39 years had significant high frequency hearing loss. High frequency hearing loss (high frequency Presbycusis) may occur much earlier than previously believed.
    Matched MeSH terms: Hearing Loss, High-Frequency
  2. Lim EY, Tang IP, Peyman M, Ramli N, Narayanan P, Rajagopalan R
    Eur Arch Otorhinolaryngol, 2015 Nov;272(11):3109-13.
    PMID: 25205300 DOI: 10.1007/s00405-014-3232-y
    High acoustic noise level is one of the unavoidable side effects of 3 T magnetic resonance imaging (MRI). A case of hearing loss after 3 T MRI has been reported in this institution and hence this study. The objective of this study was to determine whether temporary threshold shift (TTS) in high frequency hearing occurs in patients undergoing 3 T MRI scans of the head and neck. A total of 35 patients undergoing head and neck 3 T MRI for various clinical indications were tested with pure tone audiometry in different frequencies including high frequencies, before and after the MRI scan. Any threshold change from the recorded baseline of 10 dB was considered significant. All patients were fitted with foamed 3 M earplugs before the procedure following the safety guidelines for 3 T MRI. The mean time for MRI procedure was 1,672 s (range 1,040-2,810). The noise dose received by each patient amounted to an average of 3,906.29% (1,415-9,170%). The noise dose was derived from a normograph used by Occupational Noise Surveys. This was calculated using the nomograph of L eq, L EX, noise dose and time. There was no statistically significant difference between the hearing threshold before and after the MRI procedures for all the frequencies (paired t test, P > 0.05). For patients using 3 M foamed earplugs, noise level generated by 3 T MRI during routine clinical sequence did not cause any TTS in high frequency hearing.
    Matched MeSH terms: Hearing Loss, Noise-Induced/etiology*
  3. Lee SM, Lee JH, Song ES, Kim SJ, Kim JH, Jakes RW, et al.
    Hum Vaccin Immunother, 2018 Aug 07.
    PMID: 30084702 DOI: 10.1080/21645515.2018.1502525
    In 2010, Korea introduced 10-valent pneumococcal conjugate vaccine for children aged 6 weeks to 5 years against invasive disease caused by Streptococcus pneumoniae serotypes 1, 4, 5, 6B, 7F, 9V, 14, 18C, 19F, 23F and cross-reactive 19A. The aim of this 6-year real-world study of 646 healthy Korean children from 16 centers vaccinated in routine practice is to monitor vaccine safety, as per Ministry of Food and Drug Safety regulations. Around 50% had a past or existing medical condition, 19.3% an existing condition and 7.6% received concomitant medication). Total of 489 recorded adverse events (AEs) were reported in 274 infants; 86% were mild and the rest moderate, only three were reported as serious. Most AEs (97.8%) were not related to vaccination; one case of injection-site swelling and of fever was related, two cases of fever were probably related, five cases of fever and one case each of diarrhea and coughing were possibly related. None of the serious AEs were related to vaccination. Of 11 adverse drug reactions (ADRs) in 10 subjects, none were serious. Overall, 263 subjects (40.7%) received medication (mainly antibiotics or antipyretics) for the treatment of an AE, of which 6 subjects were treated for an ADR. There was no difference in the incidence of AEs according to age, sex or concomitant vaccination. Subjects with an existing medical condition had significantly more AEs than those without any conditions (p = 0.03), but no differences regarding ADRs. Four-dose vaccination with PHiD-CV appears to have a clinically-acceptable safety profile for Korean children. ClinicalTrials.gov identifier: NCT01248988.
    Matched MeSH terms: Hearing Loss, Sensorineural
  4. Ibrahim IA, Ting HN, Moghavvemi M
    J Int Adv Otol, 2019 Apr;15(1):87-93.
    PMID: 30924771 DOI: 10.5152/iao.2019.4553
    OBJECTIVES: This study uses a new approach for classifying the human ethnicity according to the auditory brain responses (electroencephalography [EEG] signals) with a high level of accuracy. Moreover, the study presents three different algorithms used to classify the human ethnicity using auditory brain responses. The algorithms were tested on Malays and Chinese as a case study.

    MATERIALS AND METHODS: The EEG signal was used as a brain response signal, which was evoked by two auditory stimuli (Tones and Consonant Vowels stimulus). The study was carried out on Malaysians (Malay and Chinese) with normal hearing and with hearing loss. A ranking process for the subjects' EEG data and the nonlinear features was used to obtain the maximum classification accuracy.

    RESULTS: The study formulated the classification of Normal Hearing Ethnicity Index and Sensorineural Hearing Loss Ethnicity Index. These indices classified the human ethnicity according to brain auditory responses by using numerical values of response signal features. Three classification algorithms were used to verify the human ethnicity. Support Vector Machine (SVM) classified the human ethnicity with an accuracy of 90% in the cases of normal hearing and sensorineural hearing loss (SNHL); the SVM classified with an accuracy of 84%.

    CONCLUSION: The classification indices categorized or separated the human ethnicity in both hearing cases of normal hearing and SNHL with high accuracy. The SVM classifier provided a good accuracy in the classification of the auditory brain responses. The proposed indices might constitute valuable tools for the classification of the brain responses according to the human ethnicity.

    Matched MeSH terms: Hearing Loss, Sensorineural/diagnosis; Hearing Loss, Sensorineural/ethnology; Hearing Loss, Sensorineural/physiopathology*; Hearing Loss/physiopathology*
  5. Mukari SZS, Ishak WS, Maamor N, Wan Hashim WF
    Ann Otol Rhinol Laryngol, 2017 Oct;126(10):697-705.
    PMID: 28845678 DOI: 10.1177/0003489417727547
    OBJECTIVES: Studies in cognitive aging demonstrated inconsistent association between hearing and cognition in older adults. Furthermore, it is still unclear if hearing loss at high frequencies, which is the earliest to be affected, is associated with cognitive functioning. This study aimed to determine the association between global cognitive status and pure tone average (PTA) at 0.5, 1, and 2 kHz (PTA low) and PTA at 4 and 8 kHz (PTA high).

    METHODS: This study involved 307 adults aged 60 years and older. Participants had their hearing and cognition measured using pure tone audiometry and Mini Mental State Examination (MMSE), respectively.

    RESULTS: Pure tone average (low) accounted for significant but minimal amount of variance in measure of MMSE. Multiple regression analyses were also performed on normal and impaired hearing cohorts and cohorts with younger (60-69 years) and older (≥70 years) groups. The results revealed a significant relationship between PTA (low) and MMSE only in the younger age group. In contrast, no significant relationship was found between PTA (high) and cognition in any of the cohorts.

    CONCLUSION: Pure tone average (low) is significantly but minimally related to measure of general cognitive status. Similar relationship is not observed between high-frequency hearing and cognition. Further research using a more comprehensive cognitive test battery is needed to confirm the lack of association between high-frequency hearing and cognition.

    Matched MeSH terms: Hearing Loss/diagnosis*
  6. Ismail AH, Munro KJ, Armitage CJ, Marsden A, Dawes PD
    Trends Hear, 2021 6 1;25:2331216520969472.
    PMID: 34057373 DOI: 10.1177/2331216520969472
    Suboptimal hearing aid use negatively impacts health and well-being. The aim of this study was to conduct a controlled trial of a behavior change intervention to promote hearing aid use. This study was a quasi-randomized controlled trial with two arms. A total of 160 first-time hearing aid users were recruited at their hearing aid fitting appointments. The control arm received standard care. In addition to standard care, the intervention arm received I-PLAN, which comprised (a) information about the consequences of hearing aid use/nonuse, (b) reminder prompt to use the hearing aids, and (c) an action plan. The primary outcome, measured at 6 weeks, was self-reported proportion of time the hearing aid was used in situations that caused hearing difficulty. Secondary outcomes were data-logged hearing aid use, self-reported hearing aid benefit, self-regulation, and habit formation. The results showed that the proportion of time the hearing aids were used in situations that caused hearing difficulty was similar in both groups. There were no statistically significant differences between groups in any outcome measure including data-logged hearing aid use. The relatively high levels of hearing aid use across research participants may have limited the potential for the intervention to impact on hearing aid use. Although the intervention materials proved acceptable and deliverable, future intervention trials should target suboptimal hearing aid users.
    Matched MeSH terms: Hearing Loss*
  7. Asma A, Azmi MN, Mazita A, Marina MB, Salina H, Norlaila M
    PMID: 22468245 DOI: 10.1007/s12070-011-0132-y
    Neuropathy is frequently a late complication of diabetes mellitus. Auditory neuropathy and microangiopathy of inner ear are the possible causes of hearing loss in diabetics. To study the correlation between glycaemic control and hearing threshold in patients with type 2 diabetes mellitus and to determine the differences of hearing threshold between groups treated with different modality. This single blind randomized controlled study was performed at the Department of Medicine and Department of Otorhinolaryngology, Hospital Universiti Kebangsaan Malaysia (UKM) between 1st May 2003 and 31st September 2004. This study was approved by Research Ethics Committee (code number FF-137). Subjects were randomized into two groups. Group 1 were patients treated with conventional oral hypoglycemic agents. The patients in group 2 were those treated with insulin injection. The subjects were seen 4 weekly for 3 months. Audiometric test were performed in all subjects at each visit. Blood were taken for fasting blood glucose, Hb1Ac, and fructosamine at every visit to determine the glycaemic controls of the subject. They were 11 patients (22 ears) treated with oral hypoglycemic agents and 17 patients treated (34 ears) with subcutaneous insulin. There is no significant difference between mean pure tone threshold before and after treatment at all frequencies in both groups. There is also no significance different in fasting glucose level and fructosamine. However, there is significant difference HbA1c levels between the two groups after treatment (P 
    Matched MeSH terms: Hearing Loss, Central; Hearing Loss
  8. Muhammad Izani S, Irfan M, Suhaimi Y
    Malays Fam Physician, 2011;6(2-3):82-4.
    PMID: 25606231 MyJurnal
    Although nasopharyngeal carcinoma (NPC) is common in this part of the world, the incidence among children is still very low worldwide. The diagnosis is sometimes delayed because of the late reporting of the symptom by the patient or parents, or difficulty in reaching the final diagnosis due to its hidden anatomical location. The challenges include the difficult endoscopy in children, inability to differentiate an adenoid from the tumour on radiograph and often the inconclusive fine needle aspiration findings. If the tumour mass at Fossa of Rosenmuller can be clearly appreciated and biopsied with undoubtedly proven histology of NPC, the diagnosis can be straight forward and treatment can be commenced as early as possible. We report a 10-year-old child presented with bilateral neck cervical lymphadenopathy and epistaxis with fine needle aspiration cytology (FNAC) of the neck mass reported as lymphoma. Further work-up confirmed he was suffering from NPC.
    Matched MeSH terms: Hearing Loss
  9. Chong FY, Jenstad LM
    Disabil Rehabil Assist Technol, 2018 08;13(6):600-608.
    PMID: 29072542 DOI: 10.1080/17483107.2017.1392619
    PURPOSE: Single-microphone noise reduction (SMNR) is implemented in hearing aids to suppress background noise. The purpose of this article was to provide a critical review of peer-reviewed studies in adults and children with sensorineural hearing loss who were fitted with hearing aids incorporating SMNR.

    METHOD: Articles published between 2000 and 2016 were searched in PUBMED and EBSCO databases.

    RESULTS: Thirty-two articles were included in the final review. Most studies with adult participants showed that SMNR has no effect on speech intelligibility. Positive results were reported for acceptance of background noise, preference, and listening effort. Studies of school-aged children were consistent with the findings of adult studies. No study with infants or young children of under 5 years old was found. Recent studies on noise-reduction systems not yet available in wearable hearing aids have documented benefits of noise reduction on memory for speech processing for older adults.

    CONCLUSIONS: This evidence supports the use of SMNR for adults and school-aged children when the aim is to improve listening comfort or reduce listening effort. Future research should test SMNR with infants and children who are younger than 5 years of age. Further development, testing, and clinical trials should be carried out on algorithms not yet available in wearable hearing aids. Testing higher cognitive level for speech processing and learning of novel sounds or words could show benefits of advanced signal processing features. These approaches should be expanded to other populations such as children and younger adults. Implications for rehabilitation The review provides a quick reference for students and clinicians regarding the efficacy and effectiveness of SMNR in wearable hearing aids. This information is useful during counseling session to build a realistic expectation among hearing aid users. Most studies in the adult population suggest that SMNR may provide some benefits to adult listeners in terms of listening comfort, acceptance of background noise, and release of cognitive load in a complex listening condition. However, it does not improve speech intelligibility. Studies that examined SMNR in the paediatric population suggest that SMNR may benefit older school-aged children, aged between 10 and 12 years old. The evidence supports the use of SMNR for adults and school-aged children when the aim is to improve listening comfort or reduce listening effort.

    Matched MeSH terms: Hearing Loss, Sensorineural/rehabilitation*
  10. Tang IP, Kevin Ng BH, Prepageran N, Donald Ngian SL, Albert Sii HW
    Med J Malaysia, 2018 10;73(5):347-348.
    PMID: 30350824 MyJurnal
    Auditory brainstem implantation (ABI) is the only solution to restore hearing when cochlear nerves are disrupted together with the pathologies where bilateral cochleae do not provide a suitable location for cochlear implantation. We reported first two successful auditory brainstem implantation cases in patients with neurofibromatosis Type II (NF2) with bilateral acoustic neuroma causing bilateral profound sensorineural hearing loss in Malaysia. A good candidate selection, dedicated surgeons and rehabilitation team as well as strong family support are the crucial factors in achieving the best possible surgical, audiological and speech outcomes.
    Matched MeSH terms: Hearing Loss, Bilateral; Hearing Loss, Sensorineural
  11. Chu FC, Hii LY, Hung TH, Lo LM, Hsieh TT, Shaw SW
    Taiwan J Obstet Gynecol, 2021 Mar;60(2):359-362.
    PMID: 33678343 DOI: 10.1016/j.tjog.2021.01.017
    OBJECTIVE: Skeletal dysplasias, caused by genetic mutations, are a heterogenous group of heritable disorders affecting bone development during fetal life. Stickler syndrome, one of the skeletal dysplasias, is an autosomal dominant connective tissue disorder caused by abnormal collagen synthesis owing to a genetic mutation in COL2A1.

    CASE REPORT: We present the case of a 38-year-old multipara woman whose first trimester screening showed a normal karyotype. However, the bilateral femur and humerus length symmetrically shortened after 20 weeks. Next-generation sequencing for mutations in potential genes leading to skeletal dysplasia detected a novel de novo mutation (c.1438G > A, p.Gly480Arg) in COL2A1, causing Stickler syndrome type 1. This pathogenic mutation might impair or destabilize the collagen structure, leading to collagen type II, IX, and XI dysfunction.

    CONCLUSION: We identified a novel de novo mutation in COL2A1 related to the STL1 syndrome and delineated the extent of the skeletal dysplasia disease spectrum.

    Matched MeSH terms: Hearing Loss, Sensorineural/diagnosis*; Hearing Loss, Sensorineural/embryology; Hearing Loss, Sensorineural/genetics*
  12. Mukari SZ, Tan KY, Abdullah A
    Int J Pediatr Otorhinolaryngol, 2006 May;70(5):843-51.
    PMID: 16246430
    This paper reports the performance of a newly implemented hospital-based universal newborn hearing screening programme and the challenges to the effective implementation.
    Matched MeSH terms: Hearing Loss/diagnosis*
  13. Tang IP, Ling XN, Prepageran N
    Med J Malaysia, 2018 10;73(5):276-280.
    PMID: 30350804 MyJurnal
    OBJECTIVES: To investigate the surgical and audiological outcome of Bonebridge (BB) at tertiary centres in Malaysia.

    STUDY DESIGN: Prospective, intra-subject repeated measurements of which each subject is his/her own control, from year 2012 to 2016 at two tertiary referral centres.

    METHODS: Twenty patients with hearing loss who fulfilled criteria for BB and showed good response to bone conduction hearing aid trial were included. Implantations of BB were carried out under general anaesthesia with preoperative computed tomography (CT) planning. Complications were monitored up to six months postoperatively. Subjects' audiometric thresholds for air conduction, bone conduction and sound field at frequencies of 250Hz to 8kHz were assessed preoperatively and at six months postoperatively. Subjects' satisfaction was evaluated at 6 months post operatively with Hearing Device Satisfaction Scale (HDSS) questionnaire.

    RESULTS: There was no major complication reported. Mean aided sound field thresholds showed significant improvement for more than 30dB from 500 to 4000kHz (p<0.05). There was no significant change in mean unaided air conduction and bone conduction thresholds pre and post operatively from 500 to 4000kHz, with a difference of less than 5dB (p>0.05). All the patients were very satisfied (>80%) with the implant, attributing to the promising functional outcome and acceptable cosmetic appearance.

    CONCLUSIONS: BB implantation surgery is safe and is effective in restoring hearing deficits among patients aged five and above with conductive or mixed hearing loss and single-sided hearing loss.

    Matched MeSH terms: Hearing Loss; Hearing Loss, Mixed Conductive-Sensorineural
  14. Rayanakorn A, Katip W, Goh BH, Oberdorfer P, Lee LH
    PLoS One, 2020;15(2):e0228488.
    PMID: 32017787 DOI: 10.1371/journal.pone.0228488
    BACKGROUND: Streptococcus suis (S.suis) is an emerging zoonosis disease with a high prevalence in Southeast Asia. There are over 1,500 cases reported globally in which majority of cases are from Thailand followed by Vietnam. The disease leads to meningitis in human with sensorineural hearing loss (SNHL) as the most common complication suffered by the patients. Early diagnosis and treatment is important to prevent severe neurological complication. In this study, we aim to develop an easy-to-use risk score to promote early diagnosis and detection of S.suis in patients who potentially develop hearing loss.

    METHODS: Data from a retrospective review of 13-year S.suis patient records in a tertiary hospital in Chiang Mai, Northern, Thailand was obtained. Univariate and multivariate logistic regressions were employed to develop a predictive model. The clinical risk score was constructed from the coefficients of significant predictors. Area under the receiver operator characteristic curve (AuROC) was identified to verify the model discriminative performance. Bootstrap technique with 1000-fold bootstrapping was used for internal validation.

    KEY RESULTS: Among 133 patients, the incidence of hearing loss was 31.6% (n = 42). Significant predictors for S. suis hearing loss were meningitis, raw pork consumption, and vertigo. The predictive score ranged from 0-4 and correctly classified 81.95% patients as being at risk of S.suis hearing loss. The model showed good power of prediction (AuROC: 0.859; 95%CI 0.785-0.933) and calibration (AuROC: 0.860; 95%CI 0.716-0.953).

    CONCLUSIONS: To our best knowledge, this is the first risk scoring system development for S.suis hearing loss. We identified meningitis, raw pork consumption and vertigo as the main risk factors of S.suis hearing loss. Future studies are needed to optimize the developed scoring system and investigate its external validity before recommendation for use in clinical practice.

    Matched MeSH terms: Hearing Loss, Sensorineural/microbiology; Hearing Loss, Sensorineural/epidemiology*
  15. Siti Norhafiza Abd Razak, Nurul Hazwani Mohd Yusoff, Farah Hana Mukhtar, Norsehah Abdul Karim, Noor Hasyimah Abu Rahim
    MyJurnal
    Working for a minimum of 8 hours, 6 days a week might have exposed the workers of public transportation to
    high noise risks. However, occupational exposures in their workplace have not been adequately characterized and
    identified. Assessment of occupational noise exposure among workers at five public transportation stations was made
    using Sound Level Meter and through questionnaire survey. The data obtained was combined to estimate the work
    shift exposure level and health impacts to the workers by using statistical analysis. The respondents participated in the
    survey to identify the symptoms of noise-induced hearing loss and other health-related problems. Results of the study
    indicated that occupational noise exposure among workers for Mean Continuous Equivalent Level, Leq= 76.17 dB(A)
    presents small risks of developing a hearing disability. Some of the workers show symptoms of noise-induced hearing
    loss and are annoyed by the sources of noise present at the public transportation.
    Matched MeSH terms: Hearing Loss, Noise-Induced
  16. Abdullah S
    Ann Acad Med Singap, 1988 Jul;17(3):388-91.
    PMID: 3218930
    The results of speech, language and hearing assessment of repaired cleft palate children and adults over a 4-year period at the Speech/Language therapy unit, Department of ENT, Faculty of Medicine, UKM are reported. The subjects were 33 incomplete cleft lip palate (ICLP), 48 unilateral complete cleft lip and palate (UCLP) and 26 bilateral complete cleft lip and palate (BCLP). Results obtained for the following assessments are reported and discussed: (i) Hearing assessment, (ii) intelligibility rate, (iii) severity of hyper-nasality and (iv) types of articulation errors and school/behaviour problems and nasal grimace. Due to subject variability in ethnicity, language and dialects and the lack of normal data, it is difficult to compare or repeat previously reported results. Assessment of intelligibility, hypernasality and articulation were conducted using the Malay language. Results obtained were compared among the three groups of subjects. The significant findings were that hypernasality, intelligibility and articulation errors were more severe in the ICLP group than in the UCLP or BCLP groups of patients. This is contrary to expectations and cannot be explained in terms of the type and/or the degree of clefting. Hence, special attention should be paid to the less overt type of cleft patients in so far as their speech assessment and rehabilitation are concerned.
    Matched MeSH terms: Hearing Loss, Conductive/etiology*; Hearing Loss/etiology*
  17. Nor Saleha IT, Noor Hassim I
    Ind Health, 2006 Oct;44(4):584-91.
    PMID: 17085919
    Noise is one of the hazards faced by workers. A cross-sectional study was conducted among industries in Negeri Sembilan with the objective to assess their compliance to Hearing Conservation Programme (HCP). The other objectives of this study were to determine the factors influencing it and to show the industries' compliance to each element of the programme. It was also to identify the association between compliance to HCP and the prevalence of hearing impairment and standard threshold shift. Data for this study were collected using questionnaires sent by mail and also the results of the latest audiometric tests. A total of 167 industries were analysed for this study. It was found that 41.3% of these industries fully complied to the programme. It was also found that the industries preferred to provide hearing protection device (92.8%) and least complied to noise control (61.1%). There were significant associations (p<0.05) between compliance and number of employees, status of ownership and the presence of officer in charge of hearing conservation programme. Having at least 150 employees actually raised the compliance to HCP in two folds (beta = 0.717, OR = 2.048, C.I 95% = 1.063 to 3.944). The prevalences of hearing impairment and standard threshold shift were 23.9% and 5.2% respectively. There was no significant association between the prevalence for hearing impairment and compliance to HCP. The prevalence for standard threshold shift was inversely related to compliance. This study showed that compliance percentage need to be improved as an effort to prevent the hearing problems among workers exposed to noise.
    Matched MeSH terms: Hearing Loss, Noise-Induced/etiology; Hearing Loss, Noise-Induced/epidemiology; Hearing Loss, Noise-Induced/prevention & control*; Hearing Loss, Sensorineural/etiology; Hearing Loss, Sensorineural/epidemiology; Hearing Loss, Sensorineural/prevention & control*
  18. Jalaei B, Zakaria MN, Sidek D
    Iran J Otorhinolaryngol, 2017 Jan;29(90):53-57.
    PMID: 28229064
    INTRODUCTION: Noonan syndrome (NS) is a heterogeneous genetic disease that affects many parts of the body. It was named after Dr. Jacqueline Anne Noonan, a paediatric cardiologist.

    CASE REPORT: We report audiological tests and auditory brainstem response (ABR) findings in a 5-year old Malay boy with NS. Despite showing the marked signs of NS, the child could only produce a few meaningful words. Audiological tests found him to have bilateral mild conductive hearing loss at low frequencies. In ABR testing, despite having good waveform morphology, the results were atypical. Absolute latency of wave V was normal but interpeak latencies of wave's I-V, I-II, II-III were prolonged. Interestingly, interpeak latency of waves III-V was abnormally shorter.

    CONCLUSION: Abnormal ABR results are possibly due to abnormal anatomical condition of brainstem and might contribute to speech delay.

    Matched MeSH terms: Hearing Loss, Conductive
  19. Lim CC, Misron K, Liew YT, Wong EHC
    BMJ Case Rep, 2019 Nov 04;12(11).
    PMID: 31690691 DOI: 10.1136/bcr-2019-232275
    Acoustic neuroma (AN) usually manifests with asymmetric hearing loss, tinnitus, dizziness and sense of disequilibrium. About 10% of patients complain of atypical symptoms, which include facial numbness or pain and sudden onset of hearing loss. Patients with atypical symptoms also tend to have larger tumours due to the delay in investigation. We report a particularly interesting case of a patient presented to us with numbness over her right hemifacial region after a dental procedure without significant acoustic and vestibular symptoms. Physical examination and pure tone audiometry revealed no significant findings but further imaging revealed a cerebellopontine angle mass. The changing trends with easier access to further imaging indicate that the presentation of patients with AN are also changing. Atypical symptoms which are persistent should raise clinical suspicion of this pathology among clinicians.
    Matched MeSH terms: Hearing Loss/etiology; Hearing Loss/physiopathology*
  20. Elango S, Htun YN, Raza H
    Int J Pediatr Otorhinolaryngol, 1994 Jan;28(2-3):125-8.
    PMID: 8157410
    A total of 165 children from a school for the deaf in Malaysia were screened to find out the prevalence of additional conductive hearing loss. Otological examination, tympanometry and pure tone audiometry were performed in all these children. Fifty-one children (30.9%) had additional conductive hearing loss. Middle ear disorders were present in 15 children (9.09%). The deaf children seldom complain about the change in their hearing sensitivity, so there is a need for regular otological examination in deaf children to detect the additional conductive hearing loss.
    Matched MeSH terms: Hearing Loss, Conductive/complications; Hearing Loss, Conductive/diagnosis*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links