Displaying publications 1 - 20 of 31 in total

Abstract:
Sort:
  1. Salim SA, Baharudin NH, Ibrahim NS, Abd Ghani Z, Ismail MN
    PMID: 38527182 DOI: 10.1080/19440049.2024.2329614
    Rice is one of the crops cultivated in Malaysia, and it is the main diet for most of the population. In this study, dispersive liquid-liquid micro-extraction (DLLME) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) were used to develop, optimise and validate a reliable, easy-to-use and quick approach to detect aflatoxin B1 (AFB1), aflatoxin B2 (AFB2), aflatoxin G1 (AFG1) and aflatoxin G2 (AFG2). The extraction recoveries in DLLME were enhanced by the addition of 5% salt, utilising chloroform as the extraction solvent and acetonitrile as the dispersive solvent. The DLLME parameters - the extraction solvent volume, salt concentration and dispersive solvent volume were optimised with Box-Behnken design (BBD) and response surface methodology (RSM). Under optimised experimental conditions, excellent linearity was obtained with a limit of detection (LOD) ranging from 0.125 to 0.25 ng g-1, a limit of quantitation (LOQ) ranging from 0.25 to 0.3 ng g-1 and a correlation value (R2) of 0.990. The matrix effects were between -11.1% and 19.9%, and recoveries ranged from 87.4% to 117.3%. The optimised and validated method was used effectively to assess aflatoxins contamination in 20 commercial rice samples collected from local supermarkets in Penang, Malaysia. AFB1 was detected at 0.41-0.43 ng g-1 in two rice samples, below the regulatory limit.
    Matched MeSH terms: Liquid Phase Microextraction*
  2. Salim SA, Sukor R, Ismail MN, Selamat J
    Toxins (Basel), 2021 04 15;13(4).
    PMID: 33920815 DOI: 10.3390/toxins13040280
    Rice bran, a by-product of the rice milling process, has emerged as a functional food and being used in formulation of healthy food and drinks. However, rice bran is often contaminated with numerous mycotoxins. In this study, a method to simultaneous detection of aflatoxins (AFB1, AFB2, AFG1, and AFG2), ochratoxin A (OTA), deoxynivalenol (DON), fumonisins (FB1 and FB2), sterigmatocystin (STG), T-2 toxin, HT-2 toxin, diacetoxyscirpenol (DAS) and zearalenone (ZEA) in rice bran was developed, optimized and validated using dispersive liquid-liquid microextraction (DLLME) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). In DLLME, using a solvent mixture of methanol/water (80:20, v/v) as the dispersive solvent and chloroform as the extraction solvent with the addition of 5% salt improved the extraction recoveries (63-120%). The developed method was further optimized using the response surface methodology (RSM) combined with Box-Behnken Design (BBD). Under the optimized experimental conditions, good linearity was obtained with a correlation coefficient (r2) ≥ 0.990 and a limit of detection (LOD) between 0.5 to 50 ng g-1. The recoveries ranged from 70.2% to 99.4% with an RSD below 1.28%. The proposed method was successfully applied to analyze multi-mycotoxin in 24 rice bran samples.
    Matched MeSH terms: Liquid Phase Microextraction*
  3. Subuhi NEAM, Saad SM, Zain NNM, Lim V, Miskam M, Kamaruzaman S, et al.
    J Sep Sci, 2020 Aug;43(16):3294-3303.
    PMID: 32519432 DOI: 10.1002/jssc.201901194
    In this work, a simple, fast, sensitive, and environmentally friendly method was developed for preconcentration and quantitative measurement of bisphenol A in water samples using gas chromatography with mass spectrometry. The preconcentration approach, namely biosorption-based dispersive liquid-liquid microextraction with extractant removal by magnetic nanoparticles was performed based on the formation of microdroplet of rhamnolipid biosurfactant throughout the aqueous samples, which accelerates the mass transfer process between the extraction solvent and sample solution. The process is then followed by the application of magnetic nanoparticles for easy retrieval of the analyte-containing extraction solvent. Several important variables were optimized comprehensively including type of disperser solvent and desorption solvent, rhamnolipid concentration, volume of disperser solvent, amount of magnetic nanoparticles, extraction time, desorption time, ionic strength, and sample pH. Under the optimized microextraction and gas chromatography with mass spectrometry conditions, the method demonstrated good linearity over the range of 0.5-500 µg/L with a coefficient of determination of R2  = 0.9904, low limit of detection (0.15 µg/L) and limit of quantification (0.50 µg/L) of bisphenol A, good analyte recoveries (84-120%) and acceptable relative standard deviation (1.8-14.9%, n = 6). The proposed method was successfully applied to three environmental water samples, and bisphenol A was detected in all samples.
    Matched MeSH terms: Liquid Phase Microextraction
  4. Yih Hui B, Mohamad Zain NN, Mohamad S, Varanusupakul P, Osman H, Raoov M
    Food Chem, 2020 Jun 01;314:126214.
    PMID: 31972404 DOI: 10.1016/j.foodchem.2020.126214
    Poly(β-cyclodextrin-ionic liquid) grafted magnetic nanoparticles combined with 1-octanol as supramolecular solvents (SUPRASs) presenting new ferrofluid was developed and successfully applied in the dispersive liquid-phase microextraction of seven representative polycyclic aromatic hydrocarbons. One variable at-a-time (OVAT) analysis and response surface methodology (RSM) were used for efficient optimization of the main variables. The calibration curves were found to be linear in the range of 0.1-150 ng mL-1 with correlation of determinations (R2) ranging from 0.9944 to 0.9986. Detection limits ranged at 0.02-0.07 ng mL-1 for all studied PAHs. The intra and inter-day precision values (RSD %) were in the range of 1.80%-7.56% and 2.97%-8.23%, respectively. The ferrofluid showed a satisfactory reproducibility between 1.72% and 5.90%, and acceptable recovery values at 84%-110% were obtained for the real samples analysis. The optimized method was successfully applied to access the content safety of the PAHs studied in a variety of commercial food and beverages available in Malaysia.
    Matched MeSH terms: Liquid Phase Microextraction
  5. Saad SM, Aling NA, Miskam M, Saaid M, Mohamad Zain NN, Kamaruzaman S, et al.
    R Soc Open Sci, 2020 Apr;7(4):200143.
    PMID: 32431904 DOI: 10.1098/rsos.200143
    This work describes the development of a new methodology based on magnetic nanoparticles assisted dispersive liquid-liquid microextraction (DLLME-MNPs) for preconcentration and extraction of chloramphenicol (CAP) antibiotic residues in water. The approach is based on the use of decanoic acid as the extraction solvent followed by the application of MNPs to magnetically retrieve the extraction solvent containing the extracted CAP. The coated MNPs were then desorbed with methanol, and the clean extract was analysed using ultraviolet-visible spectrophotometry. Several important parameters, such as the amount of decanoic acid, extraction time, stirring rate, amount of MNPs, type of desorption solvent, salt addition and sample pH, were evaluated and optimized. Optimum parameters were as follows: amount of decanoic acid: 200 mg; extraction time: 10 min; stirring rate: 800 rpm; amount of MNPs: 60 mg; desorption solvent: methanol; salt: 10%; and sample pH, 8. Under the optimum conditions, the method demonstrated acceptable linearity (R2 = 0.9933) over a concentration range of 50-1000 µg l-1. Limit of detection and limit of quantification were 16.5 and 50.0 µg l-1, respectively. Good analyte recovery (91-92.7%) and acceptable precision with good relative standard deviations (0.45-6.29%, n = 3) were obtained. The method was successfully applied to tap water and lake water samples. The proposed method is rapid, simple, reliable and environmentally friendly for the detection of CAP.
    Matched MeSH terms: Liquid Phase Microextraction
  6. Agus BAP, Hussain N, Selamat J
    Food Chem, 2020 Jan 15;303:125398.
    PMID: 31470272 DOI: 10.1016/j.foodchem.2019.125398
    Roasting is an important process in cocoa production which may lead to formation of non-desirable compounds such as polycyclic aromatic hydrocarbons (PAHs). Therefore, PAH4 (sum of four different polycyclic aromatic hydrocarbons; benz[a]anthracene, chrysene, benzo[b]fluoranthene, and benzo[a]pyrene) in roasted cocoa beans was determined using a modified method (combination of QuEChERS and DLLME), and quantified by HPLC-FLD. The modified method was validated and met the performance criteria required by the EU Regulation (No. 836/2011). Results show a significant (p 
    Matched MeSH terms: Liquid Phase Microextraction/methods*
  7. LIANG SUN TAN, SAW HONG LOH
    MyJurnal
    Polycyclic aromatic hydrocarbons (PAHs) are hazardous and persistent organic pollutants that usually exist at low concentrations in the environment. In this study, dispersive liquid-liquid microextraction (DLLME) technique coupled with high performance liquid chromatography-fluorescence detection (HPLC-FD) was optimized for the analysis of selected PAHs, namely phenanthrene (PHE), fluoranthene (FLA) and benzo[a]pyrene (BaP) in apple juice. Under the optimal extraction conditions (the mixture of 200 µL of acetone and 50 µL of 1-octanol was applied to extract the selected PAHs for 1 min), the DLLME-HPLC-FD showed excellent linearity over the concentration range of 5 to 200 µg/L for both PHE and FLA, and 0.01 to 5 µg/L for BaP with correlation coefficients, r ≥ 0.9956. The method offered ultra-trace detection of selected PAHs in the range of 0.002 to 0.5 µg/L, and negligible matrix effects in determining selected PAHs with relative recovery average within the range of 92.6 to 109.6% in apple juice. The advantages of applying this method for the extraction of PAHs include rapidity, simple operation, as well as small consumption of organic extraction solvent, which is beneficial for routine analysis.
    Matched MeSH terms: Liquid Phase Microextraction
  8. Mohd Hassan FW, Muggundha Raoov, Kamaruzaman S, Sanagi MM, Yoshida N, Hirota Y, et al.
    J Sep Sci, 2018 Oct;41(19):3751-3763.
    PMID: 30125466 DOI: 10.1002/jssc.201800326
    This study describes a dispersive liquid-liquid microextraction combined with dispersive solid-phase extraction method based on phenyl-functionalized magnetic sorbent for the preconcentration of polycyclic aromatic hydrocarbons from environmental water, sugarcane juice, and tea samples prior to gas chromatography with mass spectrometry analysis. Several important parameters affecting the extraction efficiency were investigated thoroughly, including the mass of sorbent, type and volume of extraction solvent, extraction time, type of desorption solvent, desorption time, type and amount of salt-induced demulsifier, and sample volume. Under the optimized extraction and gas chromatography-mass spectrometric conditions, the method revealed good linearity (10-100000 ng/L) with coefficient of determination (R2 ) of ≥0.9951, low limits of detection (3-16 ng/L), high enrichment factors (61-239), and satisfactory analyte recoveries (86.3-109.1%) with the relative standard deviations 
    Matched MeSH terms: Liquid Phase Microextraction
  9. Chong YT, Mohd Ariffin M, Mohd Tahir N, Loh SH
    Talanta, 2018 Jan 01;176:558-564.
    PMID: 28917790 DOI: 10.1016/j.talanta.2017.08.068
    Electro-mediated microextraction (EMM) combined with micro-high performance liquid chromatography-ultraviolet detection was successfully developed for the determination of selected phenols, namely 4-chlorophenol (4CP), 2-nitrophenol (2NP) and 2,4-dichlorophenols (2,4 DCP) in water. A solvent-impregnated agarose gel disc was utilized as a solvent holder in this study. Under optimum extraction conditions, the method showed good linearity in the range of 0.1-250µgL-1, 0.3-250µgL-1and 0.2-500µgL-1for 4CP, 2NP and 2,4 DCP, respectively with correlation coefficients of ≥ 0.9975, ultra-trace LODs (0.03-0.1µgL-1) and satisfactory relative recovery average (85.0-114.1%) for the analysis of selected phenols. The proposed method was rapid and eco-friendly as the solvent holder was constructed using minute amounts of extraction solvent immobilized within the biodegradable agarose gel disc. A comparative microextraction technique termed solvent-impregnated agarose gel liquid phase microextraction (AG-LPME) was re-optimized and validated for the extraction of phenols in water. The method offered good linearity, ultra-trace LODs ranging 0.1-0.5µgL-1and satisfactory average of relative recovery (86.1-114.1%). The EMM was superior in terms of sensitivity and time-effectiveness compared to AG-LPME. Both techniques combine extraction and pre-concentration in mini-scaled approaches using an eco-friendly solvent holder that fulfil the green chemistry concept.
    Matched MeSH terms: Liquid Phase Microextraction
  10. Shalash M, Makahleh A, Salhimi SM, Saad B
    Talanta, 2017 Nov 01;174:428-435.
    PMID: 28738603 DOI: 10.1016/j.talanta.2017.06.039
    A vortex-assisted liquid-liquid-liquid microextraction method followed by high performance liquid chromatography-diode array detection for the determination of fourteen phenolic acids (cinnamic, m-coumaric, chlorogenic, syringic, ferulic, o-coumaric, p-coumaric, vanillic, p-hydroxybenzoic, caffeic, 2, 4-dihydroxybenzoic, sinapic, gentisic and gallic acids) in honey, iced tea and canned coffee drink samples has been developed. The separation was achieved using a Poroshell 120-EC-C18 column under a gradient elution at a flow rate of 0.6mLmin-1 and mobile phase composed of methanol and acetic acid (1%, v/v). Under the optimum chromatographic conditions, the fourteen phenolic acids were separated in less than 32min. The extraction was performed using a small volume (400µL) of ternary organic solvents (1-pentanol, propyl acetate and 1-hexanol) dispersed into the aqueous sample (10mL) and assisted by vortex agitation (2500rpm for 45s), the analytes were next back-extracted from the organic solvent using 0.02M KOH (40µL) with vortex speed and time of 2500rpm and 60s, respectively. Under these conditions, enrichment factors of 30-193-fold were achieved. The limits of detection (LODs) were 0.05-0.68µgL-1. Recoveries in honey, iced tea and canned coffee drinks were in the range 72.2-112%. The method was successfully applied for the determination of the phenolic acids in honey, iced tea and canned coffee drinks.
    Matched MeSH terms: Liquid Phase Microextraction/methods*
  11. Alsharif AM, Tan GH, Choo YM, Lawal A
    J Chromatogr Sci, 2017 03 01;55(3):378-391.
    PMID: 27903555 DOI: 10.1093/chromsci/bmw188
    Hollow fiber liquid-phase microextraction (HF-LPME) techniques coupled to chromatographic systems have been widely used for extraction and determination of diverse compounds. HF-LPME was able to provide better results in precision, accuracy, selectivity and enrichment factor, in addition to reduction of matrix effect and carry over. It is applicable within a wide pH range and compatible with most analytical instruments which enable the utilization of HF-LPME in a wide variety of applications. This review focused on the modified HF-LPME techniques, efficiency, comparison to other LPME methods and applications.
    Matched MeSH terms: Liquid Phase Microextraction/methods*
  12. Mohamad Hanapi NS, Sanagi MM, Ismail AK, Wan Ibrahim WA, Saim N, Wan Ibrahim WN
    PMID: 28142101 DOI: 10.1016/j.jchromb.2017.01.028
    The aim of this study was to investigate and apply supported ionic liquid membrane (SILM) in two-phase micro-electrodriven membrane extraction combined with high performance liquid chromatography-ultraviolet detection (HPLC-UV) for pre-concentration and determination of three selected antidepressant drugs in water samples. A thin agarose film impregnated with 1-hexyl-3-methylimidazolium hexafluorophosphate, [C6MIM] [PF6], was prepared and used as supported ionic liquid membrane between aqueous sample solution and acceptor phase for extraction of imipramine, amitriptyline and chlorpromazine. Under the optimized extraction conditions, the method provided good linearity in the range of 1.0-1000μgL(-1), good coefficients of determination (r(2)=0.9974-0.9992) and low limits of detection (0.1-0.4μgL(-1)). The method showed high enrichment factors in the range of 110-150 and high relative recoveries in the range of 88.2-111.4% and 90.9-107.0%, for river water and tap water samples, respectively with RSDs of ≤7.6 (n=3). This method was successfully applied to the determination of the drugs in river and tap water samples. It is envisaged that the SILM improved the perm-selectivity by providing a pathway for targeted analytes which resulted in rapid extraction with high degree of selectivity and high enrichment factor.
    Matched MeSH terms: Liquid Phase Microextraction/methods*
  13. Shan TO, Mee LN, Marinah Mohd Ariffin, Saw HL
    Sains Malaysiana, 2017;46:615-621.
    Bisphenol A is an endocrine disruptor with widespread applications, especially in the production of polycarbonate and epoxy resins. Dispersive liquid-liquid microextraction based on solidification of floating organic technique has been developed for the extraction of bisphenol A from water and soft drink. The 1-undecanol has been applied as the extraction solvent because of its low density and melting point and high affinity to the analyte. The technique offered rapid and simple analysis as the 1-undecanol was homogeneously dispersed in the sample solution to speed the extraction and the collection of extraction solvent was simplified by centrifugation, cooling and melting steps.
    Matched MeSH terms: Liquid Phase Microextraction
  14. Alshishani A, Makahleh A, Yap HF, Gubartallah EA, Salhimi SM, Saad B
    Talanta, 2016 Dec 01;161:398-404.
    PMID: 27769423 DOI: 10.1016/j.talanta.2016.08.067
    A new sample preparation method, ion-pair vortex assisted liquid-liquid microextraction (VALLME-BE), for the determination of a highly polar anti-diabetic drug (metformin) in plasma sample was developed. The VALLME-BE was performed by diluting the plasma in borate buffer and extracted to 150µL 1-octanol containing 0.2M di-(2-ethylhexyl)phosphoric acid as intermediate phase. The drug was next back-extracted into 20µL of 0.075M HCl solution. The effects of pH, ion-pair concentration, type of organic solvent, volume of extraction phases, ionic strength, vortexing and centrifugation times on the extraction efficiency were investigated. The optimum conditions were at pH 9.3, 60s vortexing and 2min centrifugation. The microextract, contained metformin and buformin (internal standard), was directly injected into a HPLC unit using C1 column (250mm×4.6mm×10µm) and detected at 235nm. The method was validated and calibration curve was linear with r2>0.99 over the range of 20-2000µgL-1. The limits of detection and quantitation were 1.4 and 4.1µgL-1, respectively. The accuracy was within 94.8-108% of the nominal concentration. The relative standard deviation for inter- and intra-day precision was less than 10.8%. The method was conveniently applied for the determination of metformin in plasma samples.
    Matched MeSH terms: Liquid Phase Microextraction/methods
  15. Lawal A, Tan GH, Alsharif AM
    J AOAC Int, 2016 Nov 01;99(6):1383-1394.
    PMID: 27667201 DOI: 10.5740/jaoacint.16-0272
    Food quality and food safety are major challenges affecting agricultural and industrial aspects of production. Many contaminants from different sources contaminate foods and drinks, leading to disastrous health problems like gene mutations and cancer. Previously, many different methods have been used for the analysis of these contaminants. Liquid-liquid extraction (LLE) has been the most well-known conventional technique used, but its limitations are its tediousness, time required, and the use of large quantities of toxic organic solvents. These limitations have led to the search for other, efficient techniques that are more environmentally friendly. Hence, this review highlights recent advances in liquid-phase (single-drop, hollow fiber, and dispersive liquid-liquid) microextraction procedures for food and drink analyses. Such modifications can be justified for solving limitations associated with the traditional LLE method. The objective of this review is to serve as a reference platform for providing effective management tools for solving problems of pollution, clean-up, and control of food quality and safety globally.
    Matched MeSH terms: Liquid Phase Microextraction*
  16. Abu-Bakar NB, Makahleh A, Saad B
    J Sep Sci, 2016 Mar;39(5):947-55.
    PMID: 26718308 DOI: 10.1002/jssc.201501109
    A novel microextraction method based on vortex- and CO2 -assisted liquid-liquid microextraction with salt addition for the isolation of furanic compounds (5-hydroxymethyl-2-furaldehyde, 5-methyl-2-furaldehyde, 2-furaldehyde, 3-furaldehyde, 2-furoic and 3-furoic acids) was developed. Purging the sample with CO2 was applied after vortexing to enhance the phase separation and mass transfer of the analytes. The optimum extraction conditions were: extraction solvent (volume), propyl acetate (125 μL); sample pH, 2.4; vortexing time, 45 s; salt concentration, 25% w/v and purging time, 5 min. The analytes were separated using an ODS Hypersil C18 column (250×4.6 mm i.d, 5 μm) under gradient flow. The proposed method showed good linearities (r(2) >0.999), low detection limits (0.08-1.9 μg/L) and good recoveries (80.7-122%). The validated method was successfully applied for the determination of the furanic compounds in concentrated juice (mango, date, orange, pomegranate, roselle, mangosteen and soursop) and dried fruit (prune, date and apricot paste) samples.
    Matched MeSH terms: Liquid Phase Microextraction
  17. Sanagi MM, Loh SH, Wan Ibrahim WN, Pourmand N, Salisu A, Wan Ibrahim WA, et al.
    J Sep Sci, 2016 Mar;39(6):1152-9.
    PMID: 27027592 DOI: 10.1002/jssc.201501207
    Recently, there has been considerable interest in the use of miniaturized sample preparation techniques before the chromatographic monitoring of the analytes in unknown complex compositions. The use of biopolymer-based sorbents in solid-phase microextraction techniques has achieved a good reputation. A great variety of polysaccharides can be extracted from marine plants or microorganisms. Seaweeds are the major sources of polysaccharides such as alginate, agar, agarose, as well as carrageenans. Agarose and alginate (green biopolymers) have been manipulated for different microextraction approaches. The present review is focused on the classification of biopolymer and their applications in multidisciplinary research. Besides, efforts have been made to discuss the state-of-the-art of the new microextraction techniques that utilize commercial biopolymer interfaces such as agarose in liquid-phase microextraction and solid-phase microextraction.
    Matched MeSH terms: Liquid Phase Microextraction
  18. Makahleh A, Yap HF, Saad B
    Talanta, 2015 Oct 01;143:394-401.
    PMID: 26078176 DOI: 10.1016/j.talanta.2015.05.011
    A new, rapid and sensitive microextraction technique named vortex-assisted liquid-liquid-liquid microextraction (VALLLME) is proposed. The complete extraction process involves two steps. First, a vortex-assisted liquid-liquid microextraction (VALLME) procedure was used to extract the analytes from a relatively large volume of sample (donor phase) to a small volume of organic solvent (intermediate phase). Next, a micro-vortex-assisted liquid-liquid extraction (µ-VALLE) was used to extract the target analytes from the intermediate phase to a smaller volume of aqueous solution (acceptor phase). The final extract (acceptor phase) can be directly injected into the high performance liquid chromatography or capillary electrophoresis units without any further treatments. The selection of the intermediate phase and the manipulation of pH are key parameters that ensure good extraction efficiency of the technique. The proposed technique has been successfully applied for the determination of carvedilol (used as model analyte) in biological fluid samples. The optimum extraction conditions were: toluene as intermediate phase (150 μL); pH of the donor phase, 9.5; vortex time of the VALLME, 45 s (maximum speed, 2500 rpm); 0.1M HCl (15 μL) as acceptor phase; vortexing time of the µ-VALLME, 75 s (maximum stirring speed, 2500 rpm) and salt concentration in the donor phase, 5% (w/v). Under these conditions, enrichment factors of 51- and 418-fold for VALLME step and VALLLME procedure, respectively, were achieved.
    Matched MeSH terms: Liquid Phase Microextraction
  19. Ben-Hander GM, Makahleh A, Saad B, Saleh MI, Cheng KW
    Talanta, 2015 Jan;131:590-6.
    PMID: 25281145 DOI: 10.1016/j.talanta.2014.08.037
    A new analytical method for the simultaneous determination of the antidiabetic drugs rosiglitazone (ROS) and metformin hydrochloride (MH) with marked differences in their affinity towards organic solvents (log P of 2.4 and -1.43, respectively) was developed. Prior to the HPLC separation, the drugs were subjected to a sequential hollow fiber liquid phase microextraction (HF-LPME) procedure. Two sequential HF-LPME approaches were considered, the preferred one involves the use of two vials containing solution mixtures for the extraction of ROS (vial 1) and MH (vial 2), respectively, but using the same fiber and acceptor phase. Important parameters that affect the extraction efficiency such as extracting solvent, donor phase conditions, HCl concentration, agitation, extraction time, addition of salt, etc. were studied. Under the optimum conditions, good enrichment factors (EF, 471 and 86.6 for ROS and MH, respectively) were achieved. Calibration curves were linear over the range 1-500 (r(2)=0.998) and 5-2500 ng mL(-1) (r(2)=0.999) for ROS and MH, respectively. The relative standard deviation values (RSD%) for six replicates were below 8.4%. Detection and quantitation limits based on S/N ratio of 3 and 10 were 0.12, 1.0 and 0.36, 3.0 ng mL(-1) for ROS and MH, respectively. The proposed method is simple, sensitive and opens up new opportunities for the microextraction of analytes with contrasting properties.
    Matched MeSH terms: Liquid Phase Microextraction/methods*
  20. Makahleh A, Ben-Hander GM, Saad B
    Bioanalysis, 2015;7(6):713-23.
    PMID: 25871588 DOI: 10.4155/bio.14.307
    BACKGROUND: A simple and sensitive hollow fiber-liquid phase microextraction with in situ derivatization method was developed for the determination of α-ketoglutaric (α-KG) and pyruvic acids (PA) in small-volume urine samples. 2,4,6-trichloro phenyl hydrazine was used as derivatization agent.
    RESULTS: Under the optimum extraction conditions, enrichment factors of 742 and 400 for α-KG and PA, respectively, were achieved. Calibration curves were linear over the range 1 to 1000 ng/ml (r(2) ≥ 0.998). Detection and quantitation limits were 0.03 and 0.02, and 0.10 and 0.05 ng/ml for α-KG and PA, respectively.
    CONCLUSION: The concentrations in diabetic II and liver cancer samples were significantly lower than those from healthy people, showing their potential as biomarkers for these diseases.
    Matched MeSH terms: Liquid Phase Microextraction
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links