METHODOLOGY: Tracheal aspirates were obtained from neonates on ventilatory support. The SM test was carried out on specimens of tracheal aspirate immediately after collection. Levels of SP-A in tracheal aspirates were determined by enzyme-linked immunosorbent assay (ELISA) method. The results of the SM test and SP-A level of the tracheal aspirates were compared against the clinical diagnosis of RDS based on clinical, radiological and bacteriological findings.
RESULTS: Both the median microbubble counts (6 microbubbles/mm2, range = 0-90) and median SP-A levels (100 micrograms/L, range = 0-67447) of infants with RDS were significantly lower than those of infants with no obvious lung pathology (P < 0.0001), and pneumonia (P < 0.0001). The SM test of tracheal aspirates had higher overall accuracy for the diagnosis of RDS than measurement of SP-A levels (94.6% vs 82.4%). When the receiver operating characteristic (ROC) curves of both tests for RDS were compared, the area under the ROC curve of the SM test was larger (0.9689) than that of the SP-A method (0.8965).
CONCLUSIONS: This study showed that the SM test of tracheal aspirate was a useful bedside diagnostic test for RDS. It could be carried out at any time after birth on infants requiring ventilatory support.
MATERIALS AND METHODS: Nine phantoms were fabricated with different bifurcation angles ranging from 55.3° to 134.5°. General X-ray and CCTA were employed to acquire 2D and 3D images of the bifurcation phantoms, respectively. Multiplanar reformation (MPR) and volume rendering technique (VRT) were used to measure the bifurcation angle between the left anterior descending (LAD) and left circumflex arteries (LCx). The measured angles were compared with the true values to determine the accuracy of each measurement technique. Inter-observer variability was evaluated. The two techniques were further applied on 50 clinical CCTA cases to verify its clinical value.
RESULTS: In the phantom setting, the mean absolute differences calculated between the true and measured angles by MPR and VRT were 2.4°±2.2° and 3.8°±2.9°, respectively. Strong correlation was found between the true and measured bifurcation angles. Furthermore, no significant differences were found between the bifurcation angles measured using either technique. In clinical settings, large difference of 12.0°±10.6° was found between the two techniques.
CONCLUSION: In the phantom setting, both techniques demonstrated a significant correlation to the true bifurcation angle. Despite the lack of agreement of the two techniques in the clinical context, our findings in phantoms suggest that MPR should be preferred to VRT for the measurement of coronary bifurcation angle by CCTA.
METHODS: A random pair of neurosurgery resident and specialist conducted consecutive virtual and physical ward rounds on neurocritical patients. A virtual ward round was first conducted remotely by a specialist who received real-time audiovisual information from a resident wearing smart glasses integrated with telemedicine. Subsequently, a physical ward round was performed together by the resident and specialist on the same patient. The management plans of both ward rounds were compared, and the intrarater reliability was measured. On study completion a qualitative survey was performed.
RESULTS: Ten paired ward rounds were performed on 103 neurocritical care patients with excellent overall intrarater reliability. Nine out of 10 showed good to excellent internal consistency, and 1 showed acceptable internal consistency. Qualitative analysis indicated wide user acceptance and high satisfaction rate with the alternative method.
CONCLUSIONS: Virtual ward rounds using telemedicine via smart glasses on neurosurgical patients in critical care were feasible, effective, and widely accepted as an alternative to physical ward rounds during the coronavirus disease 2019 pandemic.
Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis.
Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and interobserver agreement was achieved.
Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients.
OBJECTIVES: To examine the accessibility of malignant SPNs in all segments of the lungs using either the 0.6mm or 1.4 mm probe and to assess the quality and inter observer interpretation of SPN confocal imaging obtained from either miniprobes.
METHODS: Radial(r)-EBUS was used to locate and sample the SPN. In-vivo pCLE analysis of the SPN was performed using either CholangioFlex (apical and posterior segments of the upper lobes) or AlveoFlex (other segments) introduced into the guide sheath before sampling. pCLE features were compared between the two probes.
RESULTS: Fourty-eight patients with malignant SPN were included (NCT01931579). The diagnostic accuracy for lung cancer using r-EBUS coupled with pCLE imaging was 79.2%. All the SPNs were successfully explored with either one of the probes (19 and 29 subjects for CholangioFlex and AlveoFlex, respectively). A specific solid pattern in the SPN was found in 30 pCLE explorations. Comparison between the two probes found no differences in the axial fibers thickness, cell size and specific solid pattern in the nodules. Extra-alveolar microvessel size appeared larger using CholangioFlex suggesting less compression effect. The kappa test for interobserver agreement for the identification of solid pattern was 0.74 (p = 0.001).
CONCLUSION: This study demonstrates that pCLE imaging of SPNs is achievable in all segments of both lungs using either the 0.6mm or 1.4mm miniprobe.