Displaying publications 1 - 20 of 34 in total

Abstract:
Sort:
  1. Younis L, Taher A, Abu-Hassan MI, Tin O
    J Contemp Dent Pract, 2009;10(4):35-42.
    PMID: 19575052
    The purpose of this study was to compare bone healing and coronal bone remodeling following both immediate and delayed placement of titanium dental implants in extraction sockets.
    Matched MeSH terms: Osseointegration*
  2. Ueda M
    Med J Malaysia, 2004 May;59 Suppl B:29.
    PMID: 15468803
    Matched MeSH terms: Osseointegration/physiology
  3. Sritharan S, Kannan TP, Norazmi MN, Nurul AA
    J Craniomaxillofac Surg, 2018 Aug;46(8):1361-1367.
    PMID: 29805067 DOI: 10.1016/j.jcms.2018.05.002
    OBJECTIVE: In this study, we evaluated the potential role of IL-6 and/or IL-17A in regulating the OPG/RANKL (osteoprotegerin/receptor activator of nuclear factor kappa b ligand) system of murine osteoblast cell line (MC3T3-E1) cultured on hydroxyapatite (HA).

    METHODS: MC3T3-E1 cells were seeded on HA and treated with recombinant IL-6 or rIL-17A or combination of the two cytokines. Cell proliferation and differentiation activity were measured by MTS and alkaline phosphatase assays respectively. Observation of cell adhesion and proliferation was examined by scanning electron microscopy. Gene and protein expressions were performed on RANKL and OPG using qPCR, Western blot and ELISA.

    RESULTS: We demonstrated that treatment with recombinant IL-17A (rIL-17A) and the combination rIL-6/rIL-17A promoted better adhesion and higher proliferation of cells on HA. Cells treated with rIL-17A and the combination cytokines showed a significant increase in differentiation activity on day 7, 10 and 14 as indicated by ALP activity (p 

    Matched MeSH terms: Osseointegration/drug effects
  4. Siar CH, Toh CG, Romanos G, Swaminathan D, Ong AH, Yaacob H, et al.
    J. Periodontol., 2003 May;74(5):571-8.
    PMID: 12816287
    Today, one critical goal in implant placement is the achievement of optimal soft tissue integration. Reports thus far have demonstrated successful soft tissue preservation in delayed loaded implants placed in anterior jaws. The aim of this study was to histomorphometrically examine the soft tissues around immediately loaded implants placed in the macaque posterior mandible.
    Matched MeSH terms: Osseointegration
  5. Shan L, Kadhum AAH, Al-Furjan MSH, Weng W, Gong Y, Cheng K, et al.
    Materials (Basel), 2019 Mar 10;12(5).
    PMID: 30857349 DOI: 10.3390/ma12050815
    It is well known that three-dimensional (3D) printing is an emerging technology used to produce customized implants and surface characteristics of implants, strongly deciding their osseointegration ability. In this study, Ti alloy microspheres were printed under selected rational printing parameters in order to tailor the surface micro-characteristics of the printed implants during additive manufacturing by an in situ, controlled way. The laser path and hatching space were responsible for the appearance of the stripy structure (S), while the bulbous structure (B) and bulbous⁻stripy composite surface (BS) were determined by contour scanning. A nano-sized structure could be superposed by hydrothermal treatment. The cytocompatibility was evaluated by culturing Mouse calvaria-derived preosteoblastic cells (MC3T3-E1). The results showed that three typical microstructured surfaces, S, B, and BS, could be achieved by varying the 3D printing parameters. Moreover, the osteogenic differentiation potential of the S, B, and BS surfaces could be significantly enhanced, and the addition of nano-sized structures could be further improved. The BS surface with nano-sized structure demonstrated the optimum osteogenic differentiation potential. The present research demonstrated an in situ, controlled way to tailor and optimize the surface structures in micro-size during the 3D printing process for an implant with higher osseointegration ability.
    Matched MeSH terms: Osseointegration
  6. Shaminea S, Kannan TP, Norazmi MN, Nurul AA
    MyJurnal
    Introduction: Cytokines have been gaining great focus due to their role in enhancing osseointegration as well as their potential in bone reconstruction. Osseointegration often faces complications in its compatibility with the implant due to rejection by the recipients own immune system. Therefore, extensive studies are being carried out to enhance osteoblast development to minimize such complication. The aim of this study was to determine the effect of different concentrations of Interleukin 6 (IL-6) and Interleukin 17a (IL-17A) in the proliferation and differentiation of murine and human osteoblasts.

    Methods: Various concentrations (5, 10, 25 and 50 ng/ml) of rIL-6 and rIL-17A were tested on both murine osteoblast (MC3T3-E1) and human feotal osteoblast (hFOB) cell lines using [3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium] (MTS) and alkaline phosphatise (ALP) assays. MTS was carried out at 24, 48, 72, 96 and 120 hours while ALP assay was done on day 1, 3, 7, 10 and 14.

    Results: MC3T3-E1 cells showed steadier proliferation and differentiation compared to hFOB. Both cell lines expressed responses in dose-dependent manner. The concentration of 10ng for IL-6 and IL-17A in the case of MC3T3-E1 cell line was found to be the most suitable for further studies.

    Conclusion: IL-6 and IL-17A enhance proliferation and ALP activity of both MC3T3-E1 and hFOB cell lines.
    Matched MeSH terms: Osseointegration
  7. Sghaireen MG, Alduraywish AA, Srivastava KC, Shrivastava D, Patil SR, Al Habib S, et al.
    PMID: 32708165 DOI: 10.3390/ijerph17145253
    Diabetes mellitus is known to compromise the various aspects of homeostasis, including the immune response and the composition of oral microflora. One of the oral manifestations of diabetes mellitus is tooth loss and the survival rate of dental implants chosen as a treatment modality for its rehabilitation is controversial. The current study aims to evaluate and compare the failure rate of dental implants between well-controlled diabetic and healthy patients. A retrospective study of case-control design was conceptualized with 121 well-controlled diabetic and 136 healthy individuals. Records of subjects who had undergone oral rehabilitation with dental implants between the periods of January 2013 to January 2016 were retrieved. Post-operative evaluation was carried out for all patients for about three years to assess the immediate and long-term success of the procedure. From a total of 742 dental implants, 377 were placed in well-controlled diabetic patients (case group) and 365 in healthy subjects (control group). A comparable (9.81%), but non-significant (p = 0.422) failure rate was found in the case group in comparison to the control group (9.04%). A non-significant (p = 0.392) raised number (4.98%) of failure cases were reported among females in comparison to males (4.44%). In respect to arch, the mandibular posterior region was reported as the highest failure cases (3.09%; p = 0.411), with 2.29% of cases reported in the mandibular anterior (p = 0.430) and maxillary posterior (p = 0.983) each. The maxillary anterior region was found to have the least number (1.75%; p = 0.999) of failure cases. More (4.98%; p = 0.361) cases were reported to fail during the functional loading stage in contrast to osseointegration (4.44%; p = 0.365). A well-controlled diabetic status does not impose any additional risk for individuals undergoing dental implant therapy.
    Matched MeSH terms: Osseointegration
  8. Rosdan S, Al-Salihi KA, Suzina AH, Samsudin AR
    Med J Malaysia, 2004 May;59 Suppl B:111-2.
    PMID: 15468843
    The main objective of the study was to determine the biodegradability, resorption and osteoconductivity potency of coral implant. Coral blocks (CORAGRAF) were prepared from sea coral Porites species. The blocks were implanted in the right mandible of rabbit model. Implants were harvested at 2 and 4 weeks intervals and subjected for light and scanning electron microscopy. Dense hydroxyapatite (DHA) was implanted in the left mandible as a control. The results of this study demonstrated that CORAGRAF is a good implant material that can accelerates bone healing and be resorbed in an acceptable time. The mechanisms of the resorption seemed to be the same (crumbling process), a first step where the edge of the coral become powdery then a second step which could be phagocytosis and dissolution in extracellular fluid.
    Matched MeSH terms: Osseointegration
  9. Rahman SA, Muhammad H, Haque S, Alam MK
    J Contemp Dent Pract, 2019 Feb 01;20(2):173-178.
    PMID: 31058631
    AIM: The aim of this study was to evaluate the changes in the peri-implant hard and soft tissues and implant stability and to assess the correlation of bone loss and peri-implant probing depth with implant stability.

    MATERIALS AND METHODS: Twenty-one patients with implants were included in this study and implants were assessed by resonance frequency analysis (RFA). Bone levels of the implants were assessed by measuring mesial and distal bone levels from the periapical radiograph, and soft tissue was assessed from probing depth using a periodontal probe. Implants were assessed for stability and probing depth at pre-loading, at 3 months and 6 months post-loading. RFA and probing depth were statistically compared from different time points. Correlation of probing depth and marginal bone loss with implant stability was also determined.

    RESULTS: The average change in implant stability quotient (ISQ) measurements from pre-loading to 6 months post-loading was found to be statistically significant (p <0.005). The average probing depth reduced from 1.767 mm at pre-loading to 1.671 mm at post-loading 3 months, and 1.600 mm at post-loading 6 months. At 6 months of function, radiographic examination yielded 0.786 mm mesial bone loss and 0.8 mm distal bone loss. It was found to be statistically significant (p <0.005) but within an acceptable range. No significant correlation was found between implant stability and bone loss; and implant stability and probing depth.

    CONCLUSION: The study revealed an increasing trend in implant stability values with the time that indicates successful osseointegration. Increasing mean values for mesial and distal bone loss were also found.

    CLINICAL SIGNIFICANCE: The success of dental implants is highly dependent on the quality of bone and implant-bone interface, i.e., osseointegration. The most important factors that influence the survival rate of an implant is initial stability. The present study found the changes in the peri-implant hard and soft tissues and implant stability. This article, while being a prospective study, may show the evidence of successful osseointegration by increasing trend in implant stability (RFA) values with time which can help to the clinician in the long-term management of implants.

    Matched MeSH terms: Osseointegration
  10. Pohchi A, Suzina AH, Samsudin AR, Al-Salihi KA
    Med J Malaysia, 2004 May;59 Suppl B:151-2.
    PMID: 15468863
    This in vivo study revealed that porous hydroxyapatite (PHA) and dense hydroxyapatite (DHA) are good implant materials that can accelerate bone healing and resorbed in acceptable time. But there were differences in the mechanism of the resorption of DHA and PHA due to variability in the physical properties and osteogenicity.
    Matched MeSH terms: Osseointegration/physiology
  11. Phang MY, Ng MH, Tan KK, Aminuddin BS, Ruszymah BH, Fauziah O
    Med J Malaysia, 2004 May;59 Suppl B:198-9.
    PMID: 15468886
    Tricalcium phosphate/hydroxyapatite (TCP/HA), hydroxyapatite (HA), chitosan and calcium sulphate (CaSO4) were studied and evaluated for possible bone tissue engineered construct acting as good support for osteogenic cells to proliferate, differentiate, and eventually spread and integrate into the scaffold. Surface morphology visualized by SEM showed that scaffold materials with additional fibrin had more cell densities attached than those without, depicting that the presence of fibrin and collagen fibers were truly a favourite choice of cells to attach. In comparison of various biomaterials used incorporated with fibrin, TCP/HA had the most cluster of cells attached.
    Matched MeSH terms: Osseointegration/physiology
  12. Parithimarkalaignan S, Padmanabhan TV
    J Indian Prosthodont Soc, 2013 Mar;13(1):2-6.
    PMID: 24431699 DOI: 10.1007/s13191-013-0252-z
    Osseointegration, defined as a direct structural and functional connection between ordered, living bone and the surface of a load-carrying implant, is critical for implant stability, and is considered a prerequisite for implant loading and long-term clinical success of end osseous dental implants. The implant-tissue interface is an extremely dynamic region of interaction. This complex interaction involves not only biomaterial and biocompatibility issues but also alteration of mechanical environment. The processes of osseointegration involve an initial interlocking between alveolar bone and the implant body, and later, biological fixation through continuous bone apposition and remodeling toward the implant. The process itself is quite complex and there are many factors that influence the formation and maintenance of bone at the implant surface. The aim of this present review is to analysis the current understanding of clinical assessments and factors that determine the success & failure of osseointegrated dental implants.
    Matched MeSH terms: Osseointegration
  13. Nur Hafizah Kamar Affendi, Nor Faharina Bt Abd Hamid
    Compendium of Oral Science, 2017;4(1):40-46.
    MyJurnal
    Objective: This article discuss a clinical case of implant retained overdenture as a predictable and effective treatment for completely edentulous arch. Material and method: A patient with an edentulous maxilla and periodontically compromised teeth in the mandible was treated using a specific surgical and prosthodontic protocol. Patient was followed for 12 months postloading. Result: The implants are still osseointegrated and able to maintain healthy mucosa surrounding implants. The patient have verbally indicated that she is satisfied with the design that gives her comfort and function. Conclusions: It appears that unsplinted freestanding implants can be used as a predictable treatment for edentulous arch.
    Matched MeSH terms: Osseointegration
  14. Najafpour HD, Suzina AH, Nizam A, Samsudin AR
    Med J Malaysia, 2004 May;59 Suppl B:121-2.
    PMID: 15468848
    There was a significant increased in Absolute Contact Length measurements of endosteal bone growth along the Nickel-Titanium (NiTi) implant coated with the natural coral powder and Hydroxyapatite (HA) compared to the non-calcium coated implants. This study demonstrated that coated implants seemed to show earlier and higher osseointergration phenomena compared to non coated ones. Furthermore, there was significantly greater bone-to-implant contact at the apical 1/3rd of the coated implants.
    Matched MeSH terms: Osseointegration/physiology*
  15. Mohammadi H, Sepantafar M
    Iran Biomed J, 2016 Sep;20(4):189-200.
    PMID: 26979401
    Titanium and its alloy are known as important load-bearing biomaterials. The major drawbacks of these metals are fibrous formation and low corrosion rate after implantation. The surface modification of biomedical implants through various methods such as plasma spray improves their osseointegration and clinical lifetime. Different materials have been already used as coatings on biomedical implant, including calcium phosphates and bioglass. However, these materials have been reported to have limited clinical success. The excellent bioactivity of calcium silicate (Ca-Si) has been also regarded as coating material. However, their high degradation rate and low mechanical strength limit their further coating application. Trace element modification of (Ca-Si) bioceramics is a promising method, which improves their mechanical strength and chemical stability. In this review, the potential of trace element-modified silicate coatings on better bone formation of titanium implant is investigated.
    Matched MeSH terms: Osseointegration/physiology*
  16. Merican AM, Randle R
    J Arthroplasty, 2006 Sep;21(6):846-51.
    PMID: 16950037
    The Fitmore titanium mesh cementless acetabular component in 115 hip arthroplasties was reviewed at an average of 33 months of follow-up. None were revised nor had infection. One hip dislocated 4 years postoperatively. Two femoral components were revised. The average Harris Hip Score at the last follow-up was 90 points. In the 96 sets of radiographs available, there was no loosening or new radiolucency. One hip had nonprogressive osteolysis adjacent to a screw. This press-fit cup has its polar region flattened and is rim loading. Noncontact (gaps) at the acetabular floor is expected and is not critical for fixation. In all but 6 hips, these gaps filled. In 5 hips, a minimal gap (
    Matched MeSH terms: Osseointegration
  17. Mazita A, Fazlina WH, Abdullah A, Goh BS, Saim L
    Singapore Med J, 2009 Nov;50(11):1072-6.
    PMID: 19960162
    The purpose of this study was to review the results of our patients with congenital canal atresia after implantation of bone-anchored hearing aids (BAHA). The occurrence of complications was also reviewed.
    Matched MeSH terms: Osseointegration
  18. Kumar NS, Sowmya N, Mehta DS, Kumar PS
    Dent Res J (Isfahan), 2013 Jan;10(1):98-102.
    PMID: 23878571 DOI: 10.4103/1735-3327.111808
    The anterior maxilla presents a challenging milieu interior for ideal placement of implants because of the compromised bone quality. With the advent of intraoral bone harvesting and augmentation techniques, immediate implant placement into fresh extraction sockets have become more predictable. Immediate implant placement has numerous advantages compared to the delayed procedure including superior esthetic and functional outcomes, maintenance of soft and hard tissue integrity and increased patient compliance. This case report exhibits immediate implant placement in the maxillary esthetic zone by combining a minimal invasive autogenous block bone graft harvest technique for ensuring successful osseointegration of the implant at the extraction site.
    Matched MeSH terms: Osseointegration
  19. Kokubo T
    Med J Malaysia, 2004 May;59 Suppl B:91-2.
    PMID: 15468833
    Metallic materials implanted into bone defects are generally encapsulated by a fibrous tissue. Some metallic materials such as titanium and tantalum, however, have been revealed to bond to the living bone without forming the fibrous tissue, when they were subjected to NaOH solution and heat treatments. Thus treated metals form bone tissue around them even in muscle, when they take a porous form. This kind of osteoconductive and osteoinductive properties are attributed to sodium titanate or tantalate layer on their surfaces formed by the NaOH and heat treatments. These layers induce the deposition of bonelike apatite on the surface of the metals in the living body. This kind of bioactive metals are useful as bone substitutes even highly loaded portions, such as hip joint, spine and tooth root.
    Matched MeSH terms: Osseointegration/physiology*
  20. Khadijah K, Mashita M, Saidu MF, Fazilah F, Khalid KA
    Med J Malaysia, 2004 May;59 Suppl B:123-4.
    PMID: 15468849
    This study is to qualitatively evaluate a locally produced hydroxyapatite (HA), made by AMREC-SIRIM in an experimental animal bone defect using New Zealand White (NZW) rabbits. HA cylindrical blocks measuring 2.5 mm (D) x 1.0 mm (H) were implanted in the rabbits' left tibia. The tibias were harvested within one to three weeks post-implantation. The implantion site was cut into thin undecalcified sections of about 30 microm to 60 microm and stained with Toluidine Blue and Goldner's Masson Trichrome. Microscopic examinations using standard light microscopy of these slides were performed.
    Matched MeSH terms: Osseointegration/physiology*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links